Undersizing Backflow Preventers



Similar documents
Cross-Connection Control. Protecting the potable water supply from contamination.

Why Does the Relief Valve Open?

FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?

A Cross-Connection is a. water system and a nonpotable CROSS-CONNECTION CONTROL BACKFLOW PREVENTION CROSS-CONNECTION CROSS-CONNECTION

Revised April (May) 2015

TCEQ Requirements. Effective Cross-Connection: Why & How. Plumbing Ordinance. Plumbing Ordinance. Plumbing Ordinance. Plumbing Ordinance

ORDINANCE NO THE CITY COUNCIL OF THE CITY OF NORTH LAS VEGAS, NEVADA, DOES HEREBY ORDAIN AS FOLLOWS:

Sample Exam Questions and Recommended References for ABC s Backflow Prevention Assembly Tester Exam

ALBUQUERQUE BERNALILLO COUNTY WATER UTILITY AUTHORITY CROSS CONNECTION PREVENTION AND CONTROL ORDINANCE

CITY OF BAY CITY ORDINANCE NO. 628

Changing a DC to an RP in the Field

Cross Connection Control and Backflow Prevention Program Guidelines

WESTFIELD WATER RESOURCES DEPARTMENT

(a) Purpose. The purpose is to safeguard potable water supplies by preventing backflow into public water systems.

ARTICLE 1141 Cross Connection Control Program

Cross Connection Control Policy

HARRIS COUNTY MUNICIPAL UTILITY DISTRICT NO SH 249, Suite 210, Houston, Texas Phone Number (281)

Metropolitan Domestic Water Improvement District. Backflow Prevention Control Ordinance. Ordinance No

The Ninth Edition of the Manual of Cross-Connection Control defines a cross-connection as follows:

77 ILLINOIS ADMINISTRATIVE CODE, PART 890 (NEW) ILLINOIS PLUMBING CODE (02/04) SUBPART I: WATER SUPPLY AND DISTRIBUTION

CROSS-CONNECTIONS AND BACKFLOW PREVENTION MANUAL

CROSS-CONNECTION CONTROL MANUAL

Installation, Maintenance, & Repair Series 4000B/LF4000B

CROSS-CONNECTION CONTROL PROGRAM MANUAL

AMOUNT New Account Deposit $50.00 Service Delinquent $10.00 Delinquency Notification $15.00 NSF Check processing $20.00

WHITE OAK BEND MUD Jones Rd, Suite 120, Houston, Texas Phone Number (281)

2010 Residential Water Heater Replacement Check List

BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL ASSEMBLIES INSTALLATION MANUAL

TUCSON BACKFLOW ORDINANCE ARTICLE V. BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL*

Title 15 - Mississippi Department of Health Part 20: Bureau of Public Water Supply Subpart 72: Public Water Supply

WATER & WASTEWATER SYSTEM DESIGN. Technical Design Manuals 1 & 2

Reference Guide for Obtaining Permits and Utility Services For New Construction

STANDARD SPECIFICATIONS AND STANDARD DRAWINGS FOR THE CONSTRUCTION OF

CHAPTER 26 PLUMBING CODE

CIPHI s 75 th Annual conference Safe Drinking Water Course Cross Connection Control and Backflow Prevention

Backflow Prevention & Cross-Connection Control Manual For the Education of Ohio Certified Backflow Prevention Technicians.

Minimum Standards for a Cross-Connection Control Program

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Lawn Sprinkler Systems Reserve Irrigation Inc. O & M. Version Roseland Drive Macedonia, Ohio

PUBLIC WORKS TECHNICAL BULLETIN July 2001 CROSS-CONNECTION CONTROL AT ARMY INSTALLATIONS

City of West Chicago Community Development Department 475 Main Street, West Chicago, IL Phone: (630) x 131 / Fax: (630)

Element D Services Plumbing

Installation, Maintenance, & Repair Series 909 and LF909 Reduced Pressure Zone Assemblies

THE JERSEY CITY MUNICIPAL UTILITIES AUTHORITY REQUIREMENTS FOR FIRE AND DOMESTIC WATER LINE AND METER INSTALLATIONS

SECTION DISINFECTION OF PIPE AND WATER STORAGE FACILITIES

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

SECTION 11 PLUMBING AND CROSS CONNECTION CONTROL DRAINS INDEX. I. Plumbing Systems II. Cross-Connections: Direct & Indirect 11-1

STATE OF CONNECTICUT CROSS CONNECTION CONTROL MANUAL

MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS

CITY OF FRISCO Irrigation Rules & Requirements. Ordinance No

SOCALGAS APROACH TO PIPELINE INTEGRITY

PLUMBING & CROSS-CONNECTION CONTROL

SCOPE OF WORK PROVISIONS FOR

Backflow Bulletin #1

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

Hancock County Combined General Health District Plumbing Regulations

WATER METER CALIBRATION, REPAIR, AND REPLACEMENT PROGRAM

Miami Dade County. Miami Dade Water & Sewer Department. Cross Connection Control Program 2/27/2015

Plumbing Code in Commercial Kitchens

Service Line Warranties of America (SLWA) is the Preferred Service Line Warranty Partner of the City of San Diego

SERVICE RULES AND REGULATIONS LOUISVILLE WATER COMPANY

Questions and Answers for Local Governments

How To Get Water In Los Angelesa

Table of Contents. Definitions of Cross Connection Control... 4

Homeowner s Guide to Drainage

REQUIREMENTS FOR NEW 2 & LARGER WATER SERVICE from DES MOINES WATER WORKS

SERVICE RULES AND REGULATIONS LOUISVILLE WATER COMPANY

Facilities Maintenance Standards rev

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

WATER SUPPLY SYSTEMS FOR 150/5220-4B AAS-100 AIRCRAFT FIRE AND RESCUE PROTECTION

TEXAS STATE BOARD OF PLUMBING EXAMINERS EXAMINATION AND REGISTRATION Endorsement Training Programs

MAINTENANCE MANUAL INDEX DOUBLE CHECK ASSEMBLIES MODELS 850 & 850U 1/2" - 2"

Leak Detector Guide. Your Guide to Home Water Conservation

BACKFLOW PREVENTION Product Catalog

Irrigation System Maintenance

FERTIGATION. Lawrence J. Schwankl

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

APCO SLOW CLOSING AIR/VACUUM VALVES

C I T Y O F S E L M A F I R E D E P A R T M E N T

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

EMERGENCY RESPONSE PLAN

Maintaining Fire Protection Systems

8.1.3 General Design Guidelines. The following guidelines shall be used when designing inlets along a street section:

PREVENT FROZEN PIPES

RESIDENTIAL WATER SURVEY

RECOMMENDED PROGRAM FOR WELL AND SEPTIC SYSTEM REAL ESTATE TRANSACTION INSPECTIONS

15. Design of plumbing systems for industrial and temporary applications

Transcription:

Undersizing Backflow Preventers In the Fall 2004 issue of Cross Talk, the issue of oversized backflow preventers was discussed. It was determined that placing a backflow preventer on a water line of a size smaller than the backflow preventer would not be detrimental to the operation of the assembly. Another issue that arises periodically is the undersizing of an assembly. Undersized backflow preventer: 1-inch piping & 1/2-inch backflow preventer If the water line feeding a property were a 3-inch water line with a 3inch water meter, one would expect a 3-inch assembly to be installed. But some have desired to install a 2inch assembly instead. Perhaps this is due to the lower price of a 2-inch assembly. This is undersizing the backflow preventer assembly. A problem could occur if the assembly is undersized. The flow rate through the 2-inch assembly could exceed its rated flow. The higher velocity of water through the assembly may damage the assembly. This is not likely to occur continued on page 6 Contents Rotating Shutoff Valves p. 5 Aesthetics of Assemblies p. 3 Double Checks on Irrigation Systems p. 4

Foundation Membership The Foundation s Membership Program provides many benefits to the Members of the Foundation. These include: a twenty-five percent discount on manuals, twenty percent discount on Foundation Training Courses for any employee of the Member company/organization, the List of Approved Backflow Prevention Assemblies, printed quarterly, and access to the up-to-the-minute version of the List for those Members with Internet access. Members are encouraged to call the Foundation with technical questions. The Foundation s Engineering Staff is available to assist members with the various aspects of field testing backflow preventers, installing backflow preventers and administering their crossconnection control program. Many consider their Membership with the Foundation one of their best forms of insurance to protect the agency from liability involved when a distribution system becomes contaminated or polluted through cross-connections. Membership in the Foundation helps to provide the tools needed to effectively initiate and run a cross-connection control program. Below is a list of those who have become Members of the Foundation this past quarter: Alamo Heights, City of Albeco Inc. Apex, Town of Aylworth Fire Protection BTE CCC Advisory Comm of San Diego County EBA Engineering JPH Engineering JTS Engineering Consultants, Inc. K/C Engineering Ken Fuglee & Associates, Inc. Kentucky American Water Kevin Shaw Plumbing, Inc. Lubbock, City of McCloud C.S.D. Memphis Light, Gas and Water Miller Management Mr. Backflow Inc. Parksville, City of Parsons Slayden Plumbing & Heating Southern Nevada Backflow Services Stephanie Morgan Stuart Grittman T&S Brass and Bronze Works Tract 180 Water Company Lathrop, City of Cross Talk is published by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California for Foundation Members. Limited additional copies are available to Members upon request. 2005 University of Southern California. All rights reserved. Cross Talk SUMMER 2005 Page 2

Aesthetics of Backflow Prevention Assemblies Maintaining a backflow preventer hidden from public view can be a difficult task. Protecting the assembly from being tampered with or vandalized is a concern that any administrative authority must think about when decisions are being made regarding the installation of an assembly. In addition, public Example 1 (FRONT) From across the street the backflow preventer is successfully hidden from view. safety issues can occur like obstructing pedestrian traffic or restricting access to the handicapped. It doesn t take much walking around a downtown district or neighborhood to bump into a backflow preventer. It s not only important that these assemblies be hidden for aesthetic purposes but also to prevent the assembly from being tinkered with. Cities around the country have taken different approaches to camouflaging the assemblies. For example, some cities have taken an artistic approach to hiding the assemblies from view. The city places utility boxes on top of backflow preventers and then encourages local artists to paint on them to camouflage the plain enclosures. This approach not only prevents anyone unauthorized from tinkering with the assembly, but also adds a bit of flare to the neighborhood atmosphere. In warm weather climates backflow preventers are installed close to water meters, which typically are located at the edge of the sidewalk or property line. Example 1 (BACK) Although hidden from view the backflow preventer is still accessible for testing and maintenance. Where freezing conditions exist, placement inside a building is more common. For the administrative authority, it s important to take into account any traffic whatsoever; limiting the amount of traffic can decrease the chances of the assembly being tampered with and in the long run avoid any difficult situations. Other modes of camouflaging backflow preventers involve hiding it by limited landscaping that can include small trees, brush or inside grass shacks. Other installers use artificial rocks with hollow insides to hide the assemblies from public view. What looks like an ordinary rock at times can actually be a backflow preventer enclosure. continued on page 7 Cross Talk SUMMER 2005 Page 3

Double Checks on Irrigation Systems Double check valve assemblies have a specific use in cross-connection control, as does every type of backflow prevention assembly. The type of assembly used in any situation must depend upon the hydraulic condition and the degree of hazard of the substance against which the assembly is protecting. The double check valve assembly may be used to protect against a backpressure situation. The assembly consists of two internally loaded check valves; backpressure pressing against the backside of a properly operating No. 2 check valve will be stopped. Should the No. 2 check valve leak, the No. 1 check valve will prevent backflow from occurring, not allowing any downstream pollutants into the upstream potable water supply. Check valves do, on occasion, become fouled by debris in the water. It is possible for one or both of the check valves in a double check valve assembly to become fouled. If only one of the check valves becomes fouled the other check valve will still protect the upstream potable water. If, however, both check valves become fouled, a more serious problem may occur. Polluted water from downstream of the assembly may flow to the upstream side of the assembly should either backpressure or backsiphonage occur through the leaking check valves. Although it is not common for both check valves in a double check valve assembly to become fouled, it is certainly possible. This is the reason that the double check valve assembly was never intended to be used to protect against a health hazard. The standard for check valve assemblies was written with the thought that these assemblies would only be used to protect against a pollutant. (We use the term pollutant to mean a non-health hazard; a substance, which may be aesthetically objectionable, but will not cause illness or death.) In some areas the administrative authority has accepted the installation of double check valve assemblies on irrigation systems. When one thinks of an irrigation system, one may not think of a system with fertilizer or chemical injectors. Thus the thought of using a double check valve assembly may seem appropriate; however, it should be noted that irrigation systems are to be considered a contaminant or a health hazard. Even if there is no fertilizer or chemical injection, water may pool around sprinkler heads. This would certainly be considered a health hazard because there is no control of the quality of water pooling around the sprinkler head. Fertilizer or chemicals may be hand broadcast onto a lawn or an area being irrigated. This would certainly degrade the quality of any water pooling near the sprinkler head. Additionally, there is a good chance there is residue from animal deposits on the lawn contaminating the water. The main point is that any water pooling in an open area is subject to contamination from a variety of sources, therefore an irrigation system should always be considered a health hazard. A double check valve assembly should never be used on an irrigation system. Some have allowed double check valve assemblies to be used on irrigation systems because they believe they can protect a double check valve assembly from freezing by installing it below grade, whereas this is not Cross Talk SUMMER 2005 Page 4

acceptable with a reduced pressure principle assembly, pressure vacuum breaker, spill-resistent vacuum breaker or atmospheric vacuum breaker. The Foundation would like to recommend that all backflow prevention assemblies be installed above grade. There have been instances where double check valve assemblies have been installed below grade to prevent freezing and they have ended up completely under water due to a flooded vault. In other cases they have become completely buried because of mud filling in the vault during a rainy season. Once a double check valve assembly is submerged in water in a vault, a cross-connection has actually been created between the test cocks and the water in the vault. Again, there is no control of the quality of the water in the vault. Therefore, a backflow preventer which was installed to prevent backflow from a non-health hazard from occurring, could actually become the source of a cross-connection with a contaminant because of its submerged test cocks. Foundation Notes Rotating Shutoff Valves The Foundation often receives inquiries about rotating flanged shutoff valves. Installers or inspectors may want to rotate the shutoff valve (i.e. NRS or OS&Y Gate Valves) of some assembly in order to get it to fit into a specific area or to provide better access to the shutoff valve. The general response is that assemblies need to be installed in the orientation under which they were approved. It is true, however, the Foundation has determined that it is possible to rotate flanged shutoff valves of the 2.5- inch size and larger one bolt hole. This will not affect the operation of the assembly, the shutoff valve, nor will it affect the approval of the assembly. This only affects the flanged 2.5-inch and larger assemblies and it is important that the assembly be installed in the orientation under which it was approved. The Foundation urges its members to install all backflow preventers above grade. If a double check must be installed below grade, please make sure that adequate drainage has been provided. Cross Talk SUMMER 2005 Page 5

Undersizing Backflow Preventers continued from page 1 if the size of all the piping downstream of the assembly is 2-inches or less. However, a 3-inch meter would indicate that the property owner expects to use up to 320 gallons per minute, which is the rated flow of a 3-inch water meter (i.e. AWWA Std. C702 Compound Meters) and a 3-inch backflow preventer (Table 10-1 Manual of Cross-Connection, 9th Edition). A 2-inch backflow preventer and 2-inch water meter are both rated at 160 GPM half the rating of the 3-inch size. If a 2-inch assembly was installed on a 3-inch line with a 3-inch water meter and the water usage was in excess of the rated flow of 160 GPM, damage may be caused to the backflow preventer because of the high velocity of water which would be flowing through the assembly. Although any flow rate between 160 GPM and 320 GPM would fall within the operating parameters of the meter, this flow would exceed the parameters of the backflow preventer. A good policy and one enforced in most jurisdictions, is to install a backflow preventer of the same size as the water meter. This will prevent the possibility of damage to the backflow preventer due to undersizing. The Foundation s recommendation, in general, would be to install a backflow preventer which is sized the same as the water meter. However, it is noted that oversizing a backflow preventer should not be detrimental to the operation of the backflow preventer. Foundation Research Projects Research on Transient Flow Computer simulation and experimental study has been conducted at the Foundation laboratory to model the transient flow in a pipeline system induced by sudden closure of valves. Results of computer simulation agree well with experimental data. Pressure waves are created by the sudden valve closure. The pressure waves propagate back and forth with extremely high speed and they interact with the backflow preventers creating large impact forces on the backflow preventers installed in the system. It is found that a well designed backflow prevention assembly also acts as an impact damper to hasten the damping of the pressure surges. Cross Talk SUMMER 2005 Page 6

Aesthetics of Backflow Prevention Assemblies continued from page 3 Concealing a backflow prevention assembly from view can aid both the backflow prevention assembly tester and the general public. Reducing any risk to the assembly from being bumped into by the general public and at the same time camouflaging it from view will aid in keeping an attractive neighborhood atmosphere. Example 2 (SIDE VIEW) A recently installed backflow preventer hides behind fresh landscaping. Example 2 (FRONT VIEW) Although the backflow preventer is viewable, access to it is restricted by the bike rack and the landscaping. Cross-Connection and Backflow Vulnerability In the coming years, the Foundation will be working together with American Water Works Association on a project sponsored by the EPA and AwwaRF, on establishing useful and practical monitoring approaches that might help prevent or more rapidly detect cross-connections and backflow incidents. It will assess how to identify and contain chemical and microbiological contamination using current technologies. The project will determine the most effective technologies available, as well as recommended placement, to monitor these effects. While previous studies have focused on implementing technologies to prevent backflow, this study will focus on ways to more effectively identify and monitor possible cross-connections and potential contamination. Cross Talk SUMMER 2005 Page 7

Training Courses Tester Course 3-7 October 2005 9-13 January 2006 10-14 July 2006 Specialist Course 24-28 October 2005 23-27 January 2006 24-28 July 2006 Upcoming Events Inland County Backflow Group Seminar San Bernardino, CA 14 September 2005 Western Regional Backflow Conference Las Vegas, NV 26-27 September 2005 CA-NV AWWA Annual Fall Conference Reno, NV 10-14 October 2005 Contact Information Phone: 866-545-6340 Fax: 213-740-8399 E-mail: fccchr@usc.edu Website: www.usc.edu/fccchr First Class US Postage PAID University of Southern California Foundation for Cross-Connection Control and Hydraulic Research University of Southern California Kaprielian Hall 200 Los Angeles, California 90089-2531