MANY OF TODAY S SURGERIES USE MINIMALLY INVASIVE



Similar documents
LEAN MANAGEMENT PRINCIPLES EMERGED AS A RESULT OF

THE MAJOR GOAL OF THE ELECTRONIC MEDICAL RECORD (EMR)

LOW-TEMPERATURE STERILIZATION IS AN EFFECTIVE MEANS TO

SURGEONS HAVE LONG BEEN CONFRONTED WITH CHALLENGES AS

CRCST Self-Study Lesson Plan Lesson No. CRCST 144 (Technical Continuing Education - TCE)

SURGEONS HAVE LONG BEEN CONFRONTED WITH CHALLENGES AS

ON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)

Best Practices for Loaner Surgical Instruments

THE BASICS OF DECONTAMINATION

BC Children s Hospital Mistake-Proofing Equipment Reprocessing. Laurence Bayzand Janice Penner Sue Fuller Blamey

Improving the Quality of Surgical Trays. By: Stephen M. Kovach

Standard laryngoscope blade assemblies Directions for use

Christina Bradley Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Laparoscopic Instruments

1/22/2012. When is it a good time to learn about sterile processing in your facility? Continuing Education Contact Hours. Learning Objectives

Standard Operating Procedure

Infection Control in the Dental Practice through Proper Sterilization

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

Trouble Shooting. Pump

Matte Finish Paint Owner s Guide. Matte Finish Paint Owner s Guide. Matte Finish Paint Owner s Guide 3. NP150-V2013 (Rev 06/11/12) Printing xx/xx/12

ACO Cleaning principles for drainage

A guide to the decontamination of reusable surgical instruments STATUS IN WALES APPLIES

Back to Basics: Flexible Endoscope Processing LISA SPRUCE, DNP, RN, CNS-CP, CNOR, ACNS, ACNP, FAAN

Caring for a Tenckhoff Catheter

FMI Listeria Action Plan for Retail Delis

Transducer and System Care and Cleaning Koninklijke Philips N.V. All rights reserved. Published in USA.

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

Be on the Look-Out for These Top-10 risks in Sterile Processing

Rebuild Instructions for and Transmission

Care for your child s Central Venous Catheter (CVC)

Appendix J IBC Biohazard Spill Management Plan

Getting a Handle on Loaner Instrumentation

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

orlando OWNER S MANUAL

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

CLEANING AND SANITIZING

1/3 HP Submersible Sump Pump with Vertical Float Switch

Clinical Guideline for: Aseptic Technique

INFECTION CONTROL SURVEYOR WORKSHEET

Promoting safer use of injectable medicines

Are You Always Ready for The Joint Commission or CMS Survey?

Reprocessing. Critical & Semi-Critical Equipment

Care and use guide. Contents. a handy solution made easy. page

A. Work on this project shall consist of, but is not limited to, the following:

IMPORTANT SAFETY RULES TO FOLLOW

Standards of Practice for the Decontamination of Surgical Instruments

NOTCHED MARKER DISCS/HUBS BOX

Strategies for Effective Management of the Sterile Processing Department

INSTALLATION MANUAL. Glass Vessel Sink. I toll free: I Kraus USA Inc.

InfectIon PreventIon checklist for outpatient settings:

Benchtop Series Ultrasonic Cleaning Tanks Operations and Maintenance Instructions

Your Guide to Peritoneal Dialysis Module 3: Doing Peritoneal Dialysis at Home

All About Your Peripherally Inserted Central Catheter (PICC)

Thermo Scientific Rotor Care Guide. Protect your rotor investment

Chemotherapy Spill Response:

Ultrasonic cleaning technology and cleaning chemicals

Federal Wage System Job Grading Standard For Laboratory Working, Table of Contents

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

XONYX Solid Surface Owner's Manual

San josé OWNER S MANUAL

University of Kentucky / UK HealthCare Policy and Procedure. Policy # A03-030

REPROCESSING OF FLEXIBLE CYSTOSCOPES

1/9 INSTRUCTION MANUAL PLEASE READ BEFORE USE ENDOSCOPES

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.

(800) Cryo-Cell.com

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

Parent & Healthcare Professional Instructions for the collection of Maternal & Umbilical Cord Blood

Repair of Hyd-ro-ac Actuators

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

AORN Position Statement on Allied Health Care Providers and Support Personnel in the Perioperative Practice Setting

Infectious Waste Management Plan

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Owner s Manual & Safety Instructions

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Vaxcel PICCs Valved and Non-Valved. A Patient s Guide

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

CLEAN UP FOR VOMITING & DIARRHEAL EVENT IN RETAIL FOOD FACILITIES

Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

CAREPLUS CARE AND MAINTENANCE GUIDELINE Page 1 of 5

Section 6 Brake Drum Failure Analysis. Brake Drum Wear Conditions. What is Normal Wear? What is Deep or Excessive Wear? WARNING. Deep, Uniform Wear

Body Art Facility Infection Prevention And Control Plan Guideline

Mazda North American Operations Irvine, CA MX-5 - WATER ACCUMULATION IN FOOTWELL / PLUGGED SOFT TOP DRAINS BULLETIN NOTE

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

Mazda North American Operations Irvine, CA MX-5 - WATER ACCUMULATION IN FOOTWELL / PLUGGED SOFT TOP DRAINS BULLETIN NOTE

Community Equipment Loan Stores Guidance on Decontamination BULLETIN

Biological Safety Program

Increasing Productivity and Reducing Costs with CIP Optimization

Dual Cushion User Manual. Specialist Suppliers to the Healthcare Industry

Spicer Axles & Brakes ABIB-0302

Detergents in CSSD. Wim Renders

INSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET

Transcription:

Lesson No. CRCST 137 (Technical Continuing Education - TCE) Sponsored by: by Patti Koncur, CRCST Educational Specialist, IAHCSMM and Scott Davis, CMRP, CRCST, CHMMC Materials Manager University Medical Center of Southern Nevada, Las Vegas, NV Cleaning Complex Instruments LEARNING OBJECTIVES 1. Review steps to pre-clean complex instrumentation 2. Discuss manual preparation and cleaning processes for complex instruments 3. Describe mechanical cleaning processes for complex instruments 4. Review basic cleaning procedures for flexible endoscopes 5. Explain the importance of a quality control process to monitor the effectiveness of cleaning complex instruments MANY OF TODAY S SURGERIES USE MINIMALLY INVASIVE procedures. Instrumentation used for laparoscopic, robotic, spine and total joint, and many other surgeries is much more complex and difficult to clean than in the past. Examples of these instruments include power instrumentation and items with lumens, crevices and articulating arms. Many of these instruments have special handling requirements that make the Central Service (CS) technician s job much more challenging. The basic requirements for processing complex instruments are the same as for less complex items: thorough cleaning, meticulous inspection, use of correct packaging, and the appropriate disinfection or sterilization process. Complex instruments require multiple cleaning and decontaminating steps, and this lesson reviews these steps. OBJECTIVE 1: REVIEW STEPS TO PRE-CLEAN COMPLEX INSTRUMENTATION The primary goal of every CS department is to accurately clean and decontaminate instruments and other medical devices on a timely basis to help ensure patient safety and customer satisfaction. Surgical instrumentation that is not properly cleaned may create post-operative complications, infections for patients and instrument damage. It is always important to follow the detailed handling and cleaning instructions provided in the manufacturer s Instructions for Use (IFU) for each specific instrument; therefore, while the pre-cleaning process begins during the procedure when instruments should be kept free of gross soil, the pre-cleaning procedures may differ for each instrument. Complex instruments should be disassembled immediately after the procedure to allow moisture to penetrate deep into them and to keep gross soil from drying on their inner parts. Failure to do so can cause damage and instrument failure, and make the cleaning This series of self-study lessons on CS topics was developed by the International Association of Healthcare Central Service Materiel Management (IAHCSMM). Purdue University s Extended Campus and IAHCSMM both offer grading opportunities. Earn Continuing Education Credits Online: You can use these lessons as an in-service with your staff, or visit www.iahcsmm.org for online grading at a nominal fee. Each 20 question online quiz with a passing score of 70% or higher is worth two points (2 contact hours) toward your CRCST re-certification of 12 CEs. Mail: For written grading of individual lessons, send the completed 20-question quiz and $15 to: PEC Business Office, Purdue University, Stewart Center Room 110, 128 Memorial Mall, West Lafayette, IN 47907-2034. Each 20 question quiz with a passing score of 70% or higher is worth two points (2 contact hours) toward your CRCST re-certification of 12 CE. Subscription Series: From January 1 to June 30 each year, Purdue Extended Campus offers an annual mail-in or online self-study lesson subscription for $75 (six specific lessons worth 2 points each toward your CRCST re-certification of 12 CE). Call 800.830.0269 for details. IAHCSMM provides online grading service for any of the Lesson Plan varieties. Purdue University provides grading services solely for CRCST and CIS lesson plans. For More Information: Direct any questions about online grading to IAHCSMM at 312.440.0078, and questions about written grading to Purdue University at 800.830.0269. To print any current valid lesson for grading or review, visit www.distance.purdue.edu/training/cssp/lessons/.

Properly disassembled trocar Properly disassembled drill guide process in the decontamination area much more difficult. Photos 1 and 2 show, respectively, a trocar and a drill guide that have been properly disassembled at the point of use. Lumens should be flushed, and immersible complex devices should be disassembled and wiped with sterile water. Sterile water should be used to wipe blood from the outer surfaces of non-immersible items after they are disassembled. These instruments should never be soaked in a solution as fluid will cause major damage to their inner parts. Note: point-of-use instrument wiping does not replace any aspect of the cleaning process in the decontamination area. Each item must still be handled, inspected and properly cleaned in the CS department. After gross soil is removed, the instruments should be carefully packaged for transport to the decontamination area. All instruments should be placed in the proper containment device and secured for transport. Care should be taken to protect lighter and more delicate instruments from damage to keep all instrument parts safe and secured, and to prevent loss of small parts. Note: even heavier instruments can become damaged if they are piled or dumped into the containment device. Sharp items should be placed in a separate container for the safety of those who will handle the instruments when received in the decontamination area. Devices should not remain in solutions for transport unless required by the manufacturer. Instead, they should be kept moist during transport with a moist towel or a commercially-prepared product designed for this purpose. OBJECTIVE 2: DISCUSS THE MANUAL PREPARATION AND CLEANING PROCESSES FOR COMPLEX INSTRUMENTS Cleaning is the removal, usually with a detergent and water, of visible and non-visible soil from the surfaces, crevices, serrations, joints, and lumens of instruments, devices and equipment. It is the first and most important step in the sterilization process. One can clean without disinfecting or sterilizing, but one cannot disinfect or sterilize without thorough cleaning. The sterilization process cannot produce a sterile device if that device was not first properly cleaned. Once received in the decontamination area, each complex instrument must be inspected for cracks, defects, missing or broken parts, chips, holes in air hoses, exposed wires, and leakage of bearing oils, among other concerns. Damaged instruments should be properly tagged, cleaned and removed from service until they are properly repaired. Water hardness and temperature impact detergent effectiveness. Be sure to mix the chemicals as specified by the chemical manufacturer because improperly mixed solutions make them less effective. The manufacturer s IFU should be followed as immersible instruments are completely disassembled, if not done so at point-of-use. Then the instruments should be placed in the manufacturer s recommended solution to soak for the specified time. After the soil is loosened, each instrument should be carefully cleaned before mechanical cleaning. Use a soft, lint-free cloth to wipe all surfaces of the instrument. A soft-bristled brush can assist with cleaning box locks, serrations and other crevices. Lumens should be cleaned using a brush that fits the length of the lumen, and technicians should ensure the brush s diameter is large enough to clean the lumen s inner walls. A water/air pistol may be used to flush lumens, but be sure the appropriate-sized pistol tip is used so water can reach the lumen s inner walls. Water pistols are also effective in flushing small crevices and joint areas. Keep instruments under the surface of the solution while cleaning to avoid creating aerosols. Care should be taken to ensure all surfaces of the instruments are clean and all parts of the instrument are accounted for. Rinse each instrument as specified by the manufacturer, and ensure that all cleaning solution and debris are removed. Carefully inspect the instrument to ensure it is clean. Note: use of a magnifying device will help ensure all instrument areas are clean. Clean all surfaces of instruments that cannot be immersed using the type of solution recommended by the instrument s manufacturer. Do not immerse these instruments as water will enter the inner casing and damage them. Photo 3 (top of next page) shows the damage that can be caused when a non-immersible instrument is placed in a cleaning solution.

CRCST SELF-STUDY LESSON PLAN Damage caused by the immersion of a non-immersible instrument in a solution The use of the proper-sized brushes and water pistols (if allowed by the manufacturer) with the correct-sized tip will help clean hard-to-reach areas of non-immersible instruments. Completely rinse all cleaning solutions and debris following the manufacturer s IFU. Carefully inspect the instrument for cleanliness, paying close attention to dark cords (where soil is difficult to see), all moving parts, and crevices. Note: IFU for some handwash items specify that they be disinfected before they are sent to the assembly area. OBJECTIVE 3: DESCRIBE MECHAN- ICAL CLEANING PROCESSES FOR COMPLEX INSTRUMENTS Cleaning complex instruments is very time-consuming and requires meticulous attention to detail. The manufacturer s IFU must be carefully read and followed. Many complex instruments have specific cleaning instructions requiring more steps and time than general instrumentation. Many complex instruments should be processed in an ultrasonic cleaner, which uses the cavitation process to clean small hard-to-reach areas. Fill the ultrasonic cleaner with the recommended solution and degas (if required) before adding the instruments to be processed. All instruments should be disassembled and pre-cleaned before processing, hinged instruments should be opened, and all surfaces of each instrument should be exposed. Irrigating ultrasonic cleaners are highly effective for cleaning lumened items, such as laparoscopic and robotic instruments. When connecting items to an irrigating ultrasonic instrument, be sure the proper connections are used, and that they are connected to the proper instrument port. Run the ultrasonic cycle per the instrument manufacturer s IFU. Note: some instruments require an extended cleaning cycle. When the cleaning process is complete, ensure the instruments are completely rinsed so no chemical residues or debris remain on them. Carefully check instruments for cleanliness before further processing. Robotic instruments attached to an irrigating ultrasonic cleaner tray Photo 4 shows a technician connecting robotic instrumentation to an irrigating ultrasonic cleaner. Automated washer-decontaminators are also an effective way to clean many types of immersible instrumentation. They clean using the impingement process: a spray force of pressurized water against the instruments. All chemicals used in this equipment should be approved for the instruments being cleaned. They should be disassembled and pre-cleaned before placing them in a washer-decontaminator. Instruments should be placed in the instrument basket so as to allow water contact with all surfaces. Heavy instruments should be placed on the bottom in a manner that protects other more delicate instruments. Many complex instruments are found in orthopedic and spine loaner sets, and these may be in multi-level trays. Do not process multi-level trays in automated washer decontaminators unless each tray is removed from the case and placed in the machine separate from the other trays. Note: processing these trays with all levels together does not allow for proper instrument cleaning, and cleaning chemicals may not be completely rinsed from the inner levels. Be sure trays are placed on the washer s manifolds so they do not interfere with the spray arms, which should be checked to ensure they are not clogged and that they move freely. Consult the instrument manufacturer s IFU for the proper cycle to use in an automated washer-decontaminator because some instruments must be processed on a gentle cycle. OBJECTIVE 4: REVIEW BASIC CLEANING PROCEDURES FOR FLEXIBLE ENDOSCOPES Flexible endoscopes are exceptionally difficult-to-clean devices that require meticulous attention to detail and careful handling. Each type of flexible scope usually has different cleaning requirements, and it is important to have the manufacturer s IFU available in the decontamination area for each model of scope. As with other instrumentation, the cleaning process for flexible scopes starts at the point of use. The outer shaft should be wiped to remove all gross soil. It is usually recommended that an enzymatic solution be drawn into the scope at the point of use to help facilitate cleaning. Once received in the decontamination area, scopes should be checked for damage before processing. Damaged scopes may have special cleaning instructions

from the manufacturer to avoid causing more damage to the scope before its repair. Flexible scopes should be leak-tested using the appropriate tester and following the manufacturer s IFU for wet or dry testing. The most common areas for leaks are in the bending rubber at the distal tip of the insertion tube or at the control knobs. Leak testing verifies that the scope s inner channel(s) and seals are intact. If the scope does not pass the leak test, the processing instructions for damaged scopes should be followed. Never process a damaged scope following routine cleaning instructions, as more damage can occur. Damaged scopes should be removed from service and sent for repair. If the scope passes the leak test, remove all removable parts and immerse the scope and its parts in an approved solution. Note: if the scope has a water cap be sure it is in place before immersion. Inner channels of the scope should be cleaned by drawing an approved solution into the channel(s) with a syringe and the appropriate irrigation tubes. Use specially-designed brushes that fit the channel s diameter and that extend through the entire scope and out its distal tip. The scope s external surfaces should be cleaned with the recommended solution and a soft lint-free cloth. Follow the IFU for the correct immersion time. When the scope is cleaned, rinse all channels and exterior surfaces with copious amounts of pure water. Repeat the rinse process for a total of three complete rinses. If recommended by the manufacturer, flush the instrument channel with 70% alcohol. Dry the scope s exterior with a soft, lint-free cloth. Flush the scope s inner channels with compressed air (if approved by the manufacturer) to help facilitate the drying process. If an automated endoscope reprocessing (AER) unit with a scope cleaning cycle is used, the scope should still be manually cleaned and completely rinsed before placing it in the AER. OBJECTIVE 5: DISCUSS THE IMPORTANCE OF A QUALITY CONTROL PROCESS TO MONITOR THE EFFECTIVENESS OF CLEANING COMPLEX INSTRUMENTATION Every facility should develop a quality control process to verify the effectiveness of the cleaning protocols used for complex instruments. While visual inspection is the most common way to verify cleanliness, it is not necessarily the most effective method. Several different types of commerciallyprepared systems are available to check cleaning effectiveness. The products used should be appropriate for the instrument being inspected. Failure to perform quality checks or to monitor the cleaning process may lead to disinfection and sterilization failures. IN CONCLUSION Cleaning complex instrumentation is a time-consuming and meticulous process in which careful attention to details is required. CS technicians should never attempt to clean instruments unless they have been properly trained. They must also carefully follow the instrument manufacturer s IFU to consistently provide clean and undamaged instruments for patient use. REFERENCES Central Service Technical Manual. Seventh Edition. Chapters 9 and 12 International Association of Healthcare Central Service Material Management. 2007. Chicago, IL. ST 79: 2010 & A1:2010 & A2: 2011 & A3: 2013 & A4:2013. A comprehensive guide to steam sterilization and sterility assurance in health care facilities. Association for the Advancement of Medical Instrumentation, Arlington, VA. IAHCSMM acknowledges the assistance of the following two CS professionals who reviewed this quiz: LISA HUBER, BA, CRCST, ACE, FCS; Sterile Processing Manager, Anderson Hospital, Maryville, IL PAULA VANDIVER, CRCST, CIS; Orthopedic Specialist, Anderson Hospital, Maryville, IL ADVISORY COMMITTEE FOR SELF-STUDY LESSONS SCOTT DAVIS, CMRP, CRCST, CHMMC Materials Manager, Surgical Services Las Vegas, NV SUSAN KLACIK, ACE, CHL, CRCST, FCS CSS Manager, St. Elizabeth Health Center, Youngstown, OH PATTI KONCUR, CRCST, CHMMC, ACE Educational Specialist, IAHCSMM NATALIE LIND, FCS, CRCST, CHL Educational Director, IAHCSMM CAROL PETRO, RN, BSN, CNOR, CRCST, CIS OR Educator and Sterile Processing Educator, Indiana University Health North Hospital, Carmel, IN TECHNICAL EDITOR CARLA MCDERMOTT, RN, CRCST Clinical Nurse III, South Florida Baptist Hospital, Plant City, FL SERIES WRITER/EDITOR JACK D. NINEMEIER, PH.D. Michigan State University East Lansing, MI

Quiz - Cleaning Complex Instruments OBJECTIVE 1 1. The goal of CS is to clean and decontaminate instruments and other medical devices a. On a timely basis b. Accurately c. In accordance with APIC standards d. A and B above e. All the above 2. The instrument cleaning process starts a. In the CS decontamination area b. At the point of use c. When sterile packaging is opened d. When instruments are inspected 3. Which is true about the disassembly and removal of gross soil on complex instruments? a. They should be disassembled and gross soil should be wiped off as soon as they arrive in the decontamination area b. They should be disassembled during the procedure and gross soil should be wiped off after the procedure c. They should be disassembled in the CS area and gross soil should be wiped off in the decontamination area d. They should be disassembled and gross soil should be wiped off at the end of the procedure at the point of use 4. The process to pre-clean instruments at the point of use is the same for all instruments. 5. Complex instruments should be transported from the point of use to the decontamination area in a containment system that allows the instruments to remain in sterile water. 6. When done properly, point of use precleaning replaces the need for manual cleaning in the decontamination area. OBJECTIVE 2 7. When should complex instruments be checked for damage? a. As soon as they are received in the decontamination area b. After the instruments are properly cleaned c. While they are being packaged for transport to the decontamination area d. Immediately after the procedure at the point of use Lesson No. CRCST 137 (Technical Continuing 8. How should complex instruments be soaked before cleaning? a. In a neutral ph detergent b. In a highly acid solution, according to manufacturer s IFU c. According to manufacturer s IFU d. All the above 9. Water/air pistols must always be used to clean all lumened instruments. 10. Which is true about rinsing complex instruments? a. Immersible instruments should always be rinsed three separate times b. Non-immersible instruments should be quickly rinsed under running water c. A and B are true d. None of the above are true OBJECTIVE 3 11. Which is true about the use of ultrasonic cleaners for complex instruments? a. They use the process of impingement to clean instruments b. They should never be used to clean complex instruments c. They use the process of cavitation to clean instruments d. They are used before manual cleaning 12. When using a washer-decontaminator to clean complex instruments a. Instruments can be assembled after manual cleaning, before placing them in the washer-decontaminator b. Instruments should be disassembled and disinfected before using the washer-decontaminator c. Instruments should be disassembled and pre-cleaned before using a washerdecontaminator d. Instruments do not need to be manually cleaned when using a washerdecontaminator 13. Which is true when cleaning multiplelayered instrument sets in a washerdecontaminator? a. Remove each tray from the case and place each tray in the machine, separate from the other trays b. They can effectively be cleaned in a washer as long as the lid is removed c. They should not be processed in a washer d. They should be processed in an ultrasonic cleaner before using the washer Sponsored by: 14. Which is true when cleaning complex instruments? a. The process is time-consuming b. Meticulous attention to detail is required c. Technicians must carefully follow the manufacturer s IFU d. All the above are true OBJECTIVE 4 15. All flexible endoscopes have the same basic cleaning requirements. 16. What should occur if a damaged flexible endoscope is received in the decontamination area? a. It should be cleaned following the damaged scope cleaning process b. Damaged instruments should be cleaned the same way as undamaged instruments are cleaned c. The using department should be held responsible for the damage d. It should be cleaned with the leak tester attached 17. Flexible endoscopes only need leak testing when the scope appears damaged. 18. Flexible endoscopes should a. Be leak tested three times during the cleaning process b. Be rinsed three times after cleaning c. Be leak tested using both wet and dry leak test protocols before use d. All the above are true 19. When using an AER with a cleaning cycle a. Scopes must still be cleaned before using the AER b. Scopes do not need to be cleaned before using the AER c. The solution in the AER should be changed after each use d. The scopes must be cleaned, but not rinsed before placing them in an AER OBJECTIVE 5 20. Monitoring the cleaning process for complex instruments a. Should be undertaken daily b. May be performed using only a magnification device c. Should be performed with products appropriate for the instruments being monitored d. All the above REQUEST FOR ONLINE SCORING (payment and scoring made directly online at www.iahcsmm.org) REQUEST FOR PAPER/PENCIL SCORING (please print or type information below) I have enclosed the scoring fee of $15. (please make checks payable to Purdue University. We regret that no refunds can Name be given) Check here if you have a change of address Mailing Address (be sure to include apartment numbers or post office boxes) Check here if you wish to have your results emailed to you DETACH QUIZ, FOLD, AND RETURN TO: Purdue University PEC Business Office Stewart Center, Room 110 128 Memorial Mall West Lafayette, IN 47907-2034 800.830.0269 City State Zip Code ( ) Daytime telephone IAHCSMM Membership Number Email Address If your name has changed in the last 12 months, please provide your former name Purdue University is an equal access/equal opportunity institution