Inspection Report Sample Property Address: XXXX N. Atolia Drive Tucson AZ 85743 House and Home Brian Pemble #45238 6909 E. Kingston Drive Tucson, AZ. 85710. 520-245-7897
Table of Contents Cover Page...1 Table of Contents...2 Intro Page...3 1 Roofing...4 2 Exterior... 10 3 Garage... 12 4 Attic... 13 5(A) Master Bathroom... 14 5(B) Guest Bathroom... 15 6 Kitchen... 16 7 Interiors... 18 8 Electrical System... 20 9 Cooling System... 22 10 Heating System... 24 11 Plumbing System... 25 12 Water Heater... 27 General Summary... 28 XXXX N. Atolia Drive Page 2 of 39
Date: 4/23/2015 Time: 4:00PM Report ID: 04232015-2BP Property: XXXX N. Atolia Drive Tucson AZ 85743 Customer: Sample Comment Key or Definitions Real Estate Professional: The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property. Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear. Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting. Not Present (NP) = This item, component or unit is not in this home or building. Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement. Type of building: Single Family (1 story) Age of Home: 17 years Status of Home: Vacant Temperature (Degrees F): 70-80 Weather: Warm and Sunny People Present: Buyer's Agent, Inspector Rain in last 3 days: No XXXX N. Atolia Drive Page 3 of 39
1. Roofing The home inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, chimneys, and roof penetrations; and Signs of' leaks or abnormal condensation on building components. The home inspector shall: Describe the type of roof covering materials; and Report the methods used to observe the roofing. The home inspector is not required to: Walk on the roofing; or Observe attached accessories including but not limited to solar systems, antennae, and lightning arrestors. Styles & Materials Roof #1: Moderate Slope Estimated Age: Estimated Original to the Home Skylight(s): None Roof #2: Low Slope Estimated Age: Estimated Original to the Home Roofing Material: Concrete Tile Design Life: 25-40 years Chimneys/Vents 1: Metal Flue Pipe Furnace Roofing Material: Built - Up, Elastomeric Coated Design Life: 20-25 years Location: Main Roof Inspection Method: Walked Roof Chimneys/Vents 2: Metal Flue Pipe Water Heater Location: Rear Porch Inspection Method: Walked Roof 1.0 Roofing #1 1.1 Roofing #2 1.2 Flashings 1.3 Skylights, Chimneys and Roof Penetrations 1.4 Fascia, Soffits and Eaves S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated XXXX N. Atolia Drive Page 4 of 39
1.0 (1) Approximately 2 cracked concrete roof tiles noted. 3 slipped concrete roof tiles noted at front of home. Some underlayment exposed. Advise a full roof evaluation and repair/replacement of all damaged tiles as recommended by a qualified roofer. 1.0 Item 1(Picture) 1.0 Item 2(Picture) 1.0 Item 3(Picture) XXXX N. Atolia Drive Page 5 of 39
1.0 (2) Water staining noted at front entry eave. These section of rake tiles are not flashed (common building practice when house was built) and can be prone to moisture intrusion. Advise further evaluation of rake tiles above and repairs as recommended by a qualified roofer. 1.0 Item 4(Picture) 1.0 Item 5(Picture) XXXX N. Atolia Drive Page 6 of 39
1.0 (3) Missing rake tiles noted at right side (outside bay window), front (above entryway) and rear (above rear patio). Advise installation of rake tiles in these areas as recommended by a qualified roofer. 1.0 Item 6(Picture) 1.0 Item 7(Picture) 1.0 Item 8(Picture) XXXX N. Atolia Drive Page 7 of 39
1.0 (4) Water staining noted at front eave above garage. No visible damage to tiles above. Advise further evaluation of tiles above this area, including underlayment, with repairs as recommended by a qualified roofer. 1.0 Item 10(Picture) 1.0 Item 9(Picture) 1.0 (5) Exposed nail heads noted at tiles connecting to ridge. Advise setting and sealing of all exposed nail heads as recommended by a qualified roofer. 1.0 Item 11(Picture) 1.0 (6) Cracked concrete roof tile mortar (mud balls). Advise re-mortaring/sealing mud balls as recommended by a qualified roofer. XXXX N. Atolia Drive Page 8 of 39
1.1 Elastomeric coating is thinning/crazing at rear patio roof. Some exposed nail heads noted at drip edge. Advise a detailed evaluation of rear patio roofing and repairs as recommended by a qualified roofer. 1.1 Item 1(Picture) 1.1 Item 2(Picture) 1.1 Item 3(Picture) 1.2 See above. 1.4 See above. The roof of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Roof coverings and skylights can appear to be leak proof during inspection and weather conditions. Our inspection makes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. XXXX N. Atolia Drive Page 9 of 39
2. Exterior The home inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage door operators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector shall: Describe wall cladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility. Styles & Materials Siding #1: Frame Stucco Walkways: Concrete Crushed Rock Retaining Wall(s): No Retaining Walls Porch/Patio #1: Front Entry Concrete Driveway: Concrete Porch/Patio #2: Covered Back Porch Concrete Columns: Frame Stucco 2.0 Siding #1 2.1 Porch/Patio #1 2.2 Porch/Patio #2 2.3 Entry Doors 2.4 Columns 2.5 Foundation Surface 2.6 Windows 2.7 Walkways 2.8 Retaining Walls 2.9 Ground Slope & Site Grading 2.10 Exposed Flashings & Trim 2.11 Exhaust Vent Terminations 2.12 Electrical/GFCI 2.13 WALLS & GATES S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated 2.0 Paint is thinning on exterior. Painting of the exterior should be anticipated in the near future. 2.2 Surface chipping and concrete crack noted at rear patio. Consider sealing as needed. Cosmetic issue. 2.5 Post tension slab. Do not cut, core or drill. XXXX N. Atolia Drive Page 10 of 39
2.6 (1) Displaced inner spacer seals noted at master bedroom arched window and all 4 master bathroom windows. This may lead to early seal failure. Advise monitoring for seal failure and replacement as needed by a qualified window contractor. 2.6 Item 1(Picture) 2.6 Item 2(Picture) 2.6 (2) Scratches noted at rear patio sliding glass door. Cosmetic issue; replace as desired. 2.6 (3) Loose sill tiles noted at front entry door window. Advise securing. 2.13 Damage noted to rear patio wall. This appears to be cause by tree in area. Advise further evaluation and repairs, as needed, to wall by a qualified mason. Note : Tree is in neighbors yard and wall may, or may not, be owned by the homeowner. 2.13 Item 1(Picture) The exterior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. XXXX N. Atolia Drive Page 11 of 39
3. Garage Styles & Materials Description: Attached Two Car Roof Material: Refer to Roofing Section Concrete Tile House-Garage Separation: Covered Framing Solid Core Door Insulation: Not Determined Roof Description: Refer to Roofing Section Number 1 3.0 Garage 3.1 Roofing 3.2 Foundation 3.3 Attic Ventilation 3.4 Walls & Ceilings 3.5 Siding 3.6 Vehicle Door(s) 3.7 Door Operator(s) 3.8 Garage Door-to-House 3.9 Electric/GFCI S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated 3.1 See roofing section. 3.6 Garage door bottom seal is incomplete at western corner. Advise adding bottom seal to help prevent possible pest and/or moisture intrusion. 3.6 Item 1(Picture) 3.8 Garage door-to-house does not self-close when opened. Advise repairs/adjustments to ensure a proper self-closing of garage door-to-house. XXXX N. Atolia Drive Page 12 of 39
4. Attic The home inspector shall observe: Insulation and vapor retarders in unfinished spaces; Ventilation of attics and foundation areas; Kitchen, bathroom, and laundry venting systems; and the operation of any readily accessible attic ventilation fan, and, when temperature permits, the operation of any readily accessible thermostatic control. The home inspector shall describe: Insulation in unfinished spaces; and Absence of insulation in unfinished space at conditioned surfaces. The home inspector shall: Move insulation where readily visible evidence indicates the need to do so; and Move insulation where chimneys penetrate roofs, where plumbing drain/waste pipes penetrate floors, adjacent to earth filled stoops or porches, and at exterior doors. The home inspector is not required to report on: Concealed insulation and vapor retarders; or Venting equipment that is integral with household appliances. Styles & Materials Attic Description & Access: Exposed Framing Walk-up and in Sheathing: OSB Structural Panels Attic Insulation: Blown Fiberglass 8 + average inches Ventilation: Soffit Vents Framing: Wood Frame Trusses 4.0 Attic Access 4.1 Roof Framing 4.2 Roof Deck / Sheathing 4.3 Ventilation Provisions 4.4 Insulation 4.5 Electric S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated The insulation and ventilation of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Venting of exhaust fans or clothes dryer cannot be fully inspected and bends or obstructions can occur without being accessible or visible (behind wall and ceiling coverings). Only insulation that is visible was inspected. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. XXXX N. Atolia Drive Page 13 of 39
5(A). Master Bathroom Styles & Materials Bathroom: Master Bath 3/4 Bath Location: Master Bedroom Ventilator: Exhuast Fan 5.0.A Sink(s) 5.1.A Toilet 5.2.A Stall Shower 5.3.A Functional Flow & Drainage 5.4.A Surroundings / Enclosures 5.5.A Flooring 5.6.A Walls / Ceilings 5.7.A Ventilation 5.8.A GFCI 5.9.A Electrical 5.10.A Cabinets/Countertops S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated 5.0.A (1) Master bathroom sink stopper is detached. Advise re-attaching sink stopper apparatus. 5.0.A (2) Low flow noted at master bathroom sink. Advise cleaning aerator. 5.1.A Toilet bowl is loose at floor. No moisture detected. Advise carefully securing toilet. 5.6.A Water damage noted at master bathroom floor molding at shower corners and at toilet area, and at cabinetry. No moisture was detected at time of inspection and these appear to be older leaks. Advise monitoring area for a worsening in condition and repairs to water damaged areas as needed. 5.6.A Item 1(Picture) 5.6.A Item 2(Picture) 5.10.A See above regarding water damage. XXXX N. Atolia Drive Page 14 of 39
5(B). Guest Bathroom Styles & Materials Bathroom: Guest Bath Full Bath Location: Hallway Ventilator: Exhuast Fan 5.0.B Sink(s) 5.1.B Toilet 5.2.B Bathtub 5.3.B Functional Flow & Drainage 5.4.B Surroundings / Enclosures 5.5.B Flooring 5.6.B Walls / Ceilings 5.7.B Ventilation 5.8.B GFCI 5.9.B Electrical 5.10.B Cabinets/Countertops S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated 5.1.B Toilet bowl is loose at floor. No moisture detected. Advise carefully securing toilet. XXXX N. Atolia Drive Page 15 of 39
6. Kitchen The home inspector shall observe and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable. Styles & Materials Location: Single Kitchen Free Standing Range/Oven: Electric Ventilator: Exhaust Fan Dishwasher: Yes - Age Not Determined Built-In Microwave: No Built-in Microwave Disposal: Yes - Age Not Determined 6.0 Sink/Plumbing 6.1 Functional Flow & Drainage 6.2 Flooring 6.3 Walls/Ceiling 6.4 Cooking Unit #1 - Range 6.5 Cooking Unit #2 - Built-In Microwave 6.6 Cooking Unit #3 - Oven(s) 6.7 Garbage Disposal 6.8 Dishwasher 6.9 Electric 6.10 GFCI 6.11 Ventilator 6.12 Cabinetry 6.13 Countertop 6.14 Refrigerator S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated XXXX N. Atolia Drive Page 16 of 39
6.0 Kitchen sink is punctures and leaking. Advise sealing or replacement of sink. 6.0 Item 1(Picture) 6.6 Self-cleaning feature not tested, if present. 6.14 May or may not convey with sale. The built-in appliances of the home were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. XXXX N. Atolia Drive Page 17 of 39
7. Interiors The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments. Styles & Materials Ceiling Material(s): Conventional Wood Framing Drywall Window Types: Dual Pane Detector(s): 120V Hard Wire with Battery Back-up Wall Material(s): Conventional Wood Framing Drywall Slab Construction: Post Tension Slab Floor(s): Ceramic Tile Carpet Fireplace(s): No Fireplace 7.0 Ceilings 7.1 Walls 7.2 Floors 7.3 Steps, Stairways, Balconies and Railings 7.4 Interior Doors 7.5 Windows 7.6 Fireplace(s) 7.7 Detector(s) 7.8 Ceiling Fan(s) S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated 7.0 Water staining noted at master bathroom closet ceiling. Advise referring to roofing section for roofing recommendations and repairs to water stained areas as needed. 7.0 Item 1(Picture) 7.1 See master bathroom. XXXX N. Atolia Drive Page 18 of 39
7.5 See comments in exterior windows section. 7.7 Some smoke detectors are detached. Advise replacement of all batteries, securing smoke detectors and checking for proper operation prior to occupation. The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. XXXX N. Atolia Drive Page 19 of 39
8. Electrical System The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment. Styles & Materials Electrical Service Conductors: Below ground Branch Wire 120Volt Circuits: Copper Service Disconnect(s): Single Main Location : Exterior Estimated Amps: 200 Major Appliance 240Volt Circuits: Copper Aluminum Panel Type: Circuit breakers GFCI: At receptacles 8.0 Service Entrance Conductors 8.1 Service Grounding Provisions 8.2 Main Disconnect(s) 8.3 Distribution Panel 8.4 Sub-Panel(s) 8.5 Devices - Receptacles & Switches 8.6 Wiring / Conductors 8.7 GFCI (Ground Fault Circuit Interrupters) 8.8 AFCI (Arc Fault Circuit Interrupters) 8.9 Dryer & Other 220V Receptacles Present S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated XXXX N. Atolia Drive Page 20 of 39
8.5 Living room double-switch is wired improperly. Switches do not work in all positions. Advise repairs by a qualified electrician. 8.5 Item 1(Picture) The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. XXXX N. Atolia Drive Page 21 of 39
9. Cooling System Styles & Materials Cooling System: Central Air Conditioning Estimated Capacity: 3 tons Estimated Age: About 5 years Make: Carrier Design Life: 10-15 years Location: Right Hand Side General Distribution: Ducted Registers 9.0 System Operation 9.1 Outdoor Unit 9.2 Blower 9.3 Evaporator Section 9.4 Filter 9.5 Condensate Provisions 9.6 Ductwork 9.7 Cooling Distribution to Each Room 9.8 Thermostat Controls S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated 9.0 Temperature differential between supply and return air is 20 degrees. A temperature between 18-26 degrees is considered satisfactory. 9.1 (1) Insulation damaged or missing on cold return refrigerant line. Advise installing insulation for improved efficiency. 9.1 Item 1(Picture) XXXX N. Atolia Drive Page 22 of 39
9.1 (2) Condensate line is missing its downward elbow and does not sufficiently clear house. Advise adding PVC elbow to allow for condensate to sufficiently clear house. 9.1 Item 2(Picture) 9.3 Evaporator section is not accessible in this type of unit. 9.5 See 9.1 above. XXXX N. Atolia Drive Page 23 of 39
10. Heating System Styles & Materials Heating Unit: Forced Air Furnace Fuel : Natural Gas Estimated Age: About 5 years Make: Carrier Design Life: 10-15 years Location: Attic General Distribution: Ducted Registers 10.0 Heating Unit Operation 10.1 Burners/Coil Section 10.2 Automatic Safety Controls 10.3 Gas Fuel Lines at Unit 10.4 Combustion Air Provisions 10.5 Vent Connector 10.6 Blower 10.7 Filter 10.8 Thermostat Controls 10.9 Heating Distribution to Each Room S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated XXXX N. Atolia Drive Page 24 of 39
11. Plumbing System The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; Onsite water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials. Styles & Materials Water Source: Public Dryer Connection: Gas & Electric Water Piping: Polyethylene (PEX) Drain/Waste Lines: ABS 11.0 Water Piping 11.1 Drain/Waste Piping 11.2 Fixture Functional Flow & Drainage 11.3 Exterior Faucets 11.4 Anti-Siphon Device(s) 11.5 Laundry Exhaust Vent 11.6 Water Pressure 11.7 Gas Piping and Supports 11.8 Washer & Dryer S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated XXXX N. Atolia Drive Page 25 of 39
11.3 Front hose bib valve is not functioning (no water). Advise repair/replacement of valve by a qualified person or plumber. 11.3 Item 1(Picture) 11.6 Water pressure is 80 PSI. This is within the recommended range of 40-80 PSI. The plumbing in the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waiting for closing) rust or deposits within the pipes can further clog the piping system. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. XXXX N. Atolia Drive Page 26 of 39
12. Water Heater Styles & Materials Water Heater: Direct Heated Tank Fuel: Natural Gas Estimated Age: About 17 years Location: Garage Make: Bradford White Estimated Capacity: 40 gallons Design Life: 10-15 years 12.0 Water Heater 12.1 Vent Connector 12.2 Gas Lines at Unit 12.3 Safety Valve Provisions 12.4 Electric Supply 12.5 Circulator Pump S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected, NO= Not Operated, NR= Not Rated 12.0 Functional at time of inspection but is rated fair due to age. XXXX N. Atolia Drive Page 27 of 39
General Summary House and Home 6909 E. Kingston Drive Tucson, AZ. 85710. 520-245-7897 Customer Sample Address XXXX N. Atolia Drive Tucson AZ 85743 The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. 1. Roofing 1.0 Roofing #1 Fair (1) Approximately 2 cracked concrete roof tiles noted. 3 slipped concrete roof tiles noted at front of home. Some underlayment exposed. Advise a full roof evaluation and repair/replacement of all damaged tiles as recommended by a qualified roofer. XXXX N. Atolia Drive Page 28 of 39
1. Roofing 1.0 Item 1(Picture) 1.0 Item 2(Picture) 1.0 Item 3(Picture) (2) Water staining noted at front entry eave. These section of rake tiles are not flashed (common building practice when house was built) and can be prone to moisture intrusion. Advise further evaluation of rake tiles above and repairs as recommended by a qualified roofer. XXXX N. Atolia Drive Page 29 of 39
1. Roofing 1.0 Item 4(Picture) 1.0 Item 5(Picture) (3) Missing rake tiles noted at right side (outside bay window), front (above entryway) and rear (above rear patio). Advise installation of rake tiles in these areas as recommended by a qualified roofer. XXXX N. Atolia Drive Page 30 of 39
1. Roofing 1.0 Item 6(Picture) 1.0 Item 7(Picture) 1.0 Item 8(Picture) (4) Water staining noted at front eave above garage. No visible damage to tiles above. Advise further evaluation of tiles above this area, including underlayment, with repairs as recommended by a qualified roofer. XXXX N. Atolia Drive Page 31 of 39
1. Roofing 1.0 Item 10(Picture) 1.0 Item 9(Picture) (5) Exposed nail heads noted at tiles connecting to ridge. Advise setting and sealing of all exposed nail heads as recommended by a qualified roofer. 1.0 Item 11(Picture) (6) Cracked concrete roof tile mortar (mud balls). Advise re-mortaring/sealing mud balls as recommended by a qualified roofer. 1.1 Roofing #2 Fair Elastomeric coating is thinning/crazing at rear patio roof. Some exposed nail heads noted at drip edge. Advise a detailed evaluation of rear patio roofing and repairs as recommended by a qualified roofer. XXXX N. Atolia Drive Page 32 of 39
1. Roofing 1.1 Item 1(Picture) 1.1 Item 2(Picture) 1.1 Item 3(Picture) 2. Exterior 2.6 Windows Fair (1) Displaced inner spacer seals noted at master bedroom arched window and all 4 master bathroom windows. This may lead to early seal failure. Advise monitoring for seal failure and replacement as needed by a qualified window contractor. XXXX N. Atolia Drive Page 33 of 39
2. Exterior 2.6 Item 1(Picture) 2.6 Item 2(Picture) (2) Scratches noted at rear patio sliding glass door. Cosmetic issue; replace as desired. (3) Loose sill tiles noted at front entry door window. Advise securing. 2.13 WALLS & GATES Fair Damage noted to rear patio wall. This appears to be cause by tree in area. Advise further evaluation and repairs, as needed, to wall by a qualified mason. Note : Tree is in neighbors yard and wall may, or may not, be owned by the homeowner. 2.13 Item 1(Picture) 3. Garage 3.6 Vehicle Door(s) Fair Garage door bottom seal is incomplete at western corner. Advise adding bottom seal to help prevent possible pest and/or moisture intrusion. XXXX N. Atolia Drive Page 34 of 39
3. Garage 3.6 Item 1(Picture) 3.8 Garage Door-to-House Fair Garage door-to-house does not self-close when opened. Advise repairs/adjustments to ensure a proper self-closing of garage door-to-house. 5(A). Master Bathroom 5.0.A 5.1.A 5.6.A Sink(s) Fair (1) Master bathroom sink stopper is detached. Advise re-attaching sink stopper apparatus. (2) Low flow noted at master bathroom sink. Advise cleaning aerator. Toilet Fair Toilet bowl is loose at floor. No moisture detected. Advise carefully securing toilet. Walls / Ceilings Fair Water damage noted at master bathroom floor molding at shower corners and at toilet area, and at cabinetry. No moisture was detected at time of inspection and these appear to be older leaks. Advise monitoring area for a worsening in condition and repairs to water damaged areas as needed. XXXX N. Atolia Drive Page 35 of 39
5(A). Master Bathroom 5.6.A Item 1(Picture) 5.6.A Item 2(Picture) 5(B). Guest Bathroom 5.1.B Toilet Fair Toilet bowl is loose at floor. No moisture detected. Advise carefully securing toilet. 6. Kitchen 6.0 Sink/Plumbing Fair Kitchen sink is punctures and leaking. Advise sealing or replacement of sink. 6.0 Item 1(Picture) 7. Interiors 7.0 Ceilings XXXX N. Atolia Drive Page 36 of 39
7. Interiors Fair Water staining noted at master bathroom closet ceiling. Advise referring to roofing section for roofing recommendations and repairs to water stained areas as needed. 7.0 Item 1(Picture) 7.7 Detector(s) Fair Some smoke detectors are detached. Advise replacement of all batteries, securing smoke detectors and checking for proper operation prior to occupation. 8. Electrical System 8.5 Devices - Receptacles & Switches Fair Living room double-switch is wired improperly. Switches do not work in all positions. Advise repairs by a qualified electrician. 8.5 Item 1(Picture) XXXX N. Atolia Drive Page 37 of 39
9. Cooling System 9.0 System Operation Satisfactory Temperature differential between supply and return air is 20 degrees. A temperature between 18-26 degrees is considered satisfactory. 9.1 Outdoor Unit Fair (1) Insulation damaged or missing on cold return refrigerant line. Advise installing insulation for improved efficiency. 9.1 Item 1(Picture) (2) Condensate line is missing its downward elbow and does not sufficiently clear house. Advise adding PVC elbow to allow for condensate to sufficiently clear house. 9.1 Item 2(Picture) XXXX N. Atolia Drive Page 38 of 39
11. Plumbing System 11.3 Exterior Faucets Fair Front hose bib valve is not functioning (no water). Advise repair/replacement of valve by a qualified person or plumber. 11.3 Item 1(Picture) 11.6 Water Pressure Satisfactory Water pressure is 80 PSI. This is within the recommended range of 40-80 PSI. 12. Water Heater 12.0 Water Heater Fair Functional at time of inspection but is rated fair due to age. Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property. Prepared Using HomeGauge http://www.homegauge.com : Licensed To Brian Pemble XXXX N. Atolia Drive Page 39 of 39