Cisco Cable Radio Frequency (RF) FAQs



Similar documents
Channel Bandwidth, MHz. Symbol Rate, Msym/sec

Configuring Load Balancing and Dynamic Channel Change (DCC) on the Cisco CMTS

Configuring Load Balancing and Dynamic Channel Change (DCC) on the Cisco CMTS

CX380X Advanced Spectrum and Burst QAM Analyzer

Configuring Basic Broadband Internet Access

Configuring Basic Broadband Internet Access

Digital Signals and Testing

Technical Training Seminar on Practical Field Testing DOCSIS 3.0 for CCTA Member Companies August 24, 25 and 26, 2010 San Juan, Puerto Rico

Task or Information to Monitor. ARP table clear cable arp on page 200 show cable arp on page 205

TC-7620 DOCSIS 3.0 High Speed Cable Modem

DS2800. Broadband. Spectrum Analyzer. Key Benefits CUSTOMER PREMISE HFC DS

USER S GUIDE CGN2 RESIDENTIAL CABLE MODEM

Channel Bonding in DOCSIS 3.0. Greg White Lead Architect Broadband Access CableLabs

Achieving New Levels of Channel Density in Downstream Cable Transmitter Systems: RF DACs Deliver Smaller Size and Lower Power Consumption

2.0 System Description

DOCSIS 3.1: WHAT IS IT, HOW DOES IT WORK, AND HOW CAN YOU PREPARE FOR IT? Daniel Howard, SCTE CTO July 16, 2013

DSAM Product Family Series Complete DSAM Meter Functionality

Cable Modems. Definition. Overview. Topics. 1. How Cable Modems Work

Deviser DS2800 Handheld Digital TV Spectrum Analyser

MATRIX TECHNICAL NOTES

AC3200 INTELLIGENT BROADBAND AMPLIFIER

E-Option Multi-taps Conditioning at the Tap

Cable 101. A Broadband Telecommunications Primer for Non-technical Personnel

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

User Guide. Cable Modem CM30XX

Technicolor ATSC-8. User s Guide Technicolor. All Rights reserved

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

TR-3 Channel Editor. Software Manual

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Cable Network Overview. Presented by: Ma1 Schmi1 (CableLabs)

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

PARADISE DATACOM APPLICATION NOTE CONTROL AND MONITOR OF DISTANT END TERMINAL USING LOCAL MODEM WEB USER INTERFACE EVO_AN_001

Link Link sys E3000 sys RE1000

DAS202Tools v1.0.0 for DAS202 Operating Manual

Ubee Interactive DOCSIS 3.0 Cable Modem Model: DDM3513

DOCSIS 3.1. High Level Overview at NANOG 59. Karthik Sundaresan, Lead Architect. Oct 09, Cable Television Laboratories, Inc.

FCC CABLE RULES Technical Standards

Next Generation of High Speed. Modems8

How To Make A Network More Interactive

Product Specifications

MoCA 1.1 Specification for Device RF Characteristics

Public Switched Telephone System

Ajay Gummalla-July 2001

Getting Started with IntelleView POS Administrator Software

Proactive Network Maintenance for EPoC

How To Define Hfc Technology

How To Use A Dnsis On A Dsis 2 (Wireless) On A Pc Or Ipad (Networking) On An Ipad Or Ipa (Netnet) On Pc Or Mac Or Ip

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

User guide. QAM module / C. TRIAX - your ultimate connection. Rev C. TRIAX - your ultimate connection

RFS-805. Digital Modulator AV to COFDM. User Manual

Model GS Port Node 1 GHz with 40/52 MHz split

Pathtrak Return Path Monitoring System

MOTOROLA SB5101 Cable Modem Overview November 2004

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

Cable Modem Load Balancing for Cisco Series ubrs

USING WIRELESS DIAGNOSTICS Application Note 31

Advanced DOCSIS Set-Top Gateway Implementation Design Guide for System Release 5.0

Wideband: Delivering the Connected Life

Broadband 101: Installation and Testing

Please enter the Network WAN page and click the Edit icon of WAN1. Figure The WAN setting of Network

- Cable and DSL Technologies -

Belkin High Speed Cable Modem with USB and Ethernet. User Manual

Chapter 9 Using Telephone and Cable Networks for Data Transmission

TV & SATELLITE LEVEL METERS

Technical Training Seminar on Troubleshooting the Triple Play Services for CCTA Member Companies August 24, 25, 26, 2010 San Juan, Puerto Rico

Broadband Technology Clinic. Burlington Telecom Advisory Board

Cisco CNR and DHCP FAQs for Cable Environment

Trouble shooting Guide <<<Field and NOC Engineer Perspective>>>

USER S GUIDE. Hitron CDE VERSION 1.0 APRIL DEFAULT LOGIN DETAILS IP Address Username admin Password admin

ACRS 2.0 User Manual 1

Lab 1: The Digital Oscilloscope

MoCA Testing for triple play and Whole Home DVR. Jim Carvajal Applications Specialist, Cable MSO Caribbean & Latin America

HTT 101. HDMI/YPbPr/S-Video/AV to DVB-T. HDMI/YPbPr/S Encoder Modulator

The Recommended Testing Process for PacketCableTM Voice Service at a Customer Premises

PPM Users Manual Signature Software

DOCSIS/EuroDOCSIS 3.0 Cable Modems

MANUAL FOR RX700 LR and NR

DSAM Digital Services Activation Meter

Base Station Adjacent Time Slot Rejection Measurement with CMD and SME

RF Video Distribution System. Why Z-Band is The Right Choice for Quality Video

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Next Steps in the Evolution of the Broadband Network

CM500 High Speed Cable Modem User Manual

COPYRIGHT TRADEMARKS

HDO700 P FIBRE OPTIC TRANSMITTER

MODULATION Systems (part 1)

FWS WiTDM Series KWA-O8800-I User Manual

Increasing cable bandwidth to retain high-value customers

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

ITU-T RECOMMENDATION J.122, SECOND-GENERATION TRANSMISSION SYSTEMS FOR INTERACTIVE CABLE TELEVISION SERVICES IP CABLE MODEMS

Cisco SNMP FAQs for Cable Networks

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

CM400 High Speed Cable Modem User Manual

VePAL CATV Analyzers. Key Features. Platform Highlights CX150-D3+ CX180-D3+ DOCSIS 3.0 CATV Analyzer

RF Measurements Using a Modular Digitizer

(Refer Slide Time: 2:10)

Transcription:

Table of Contents Cable Radio Frequency (RF) FAQs...1 Questions...1...1 Related Information...8 i

Cable Radio Frequency (RF) FAQs Questions How do I measure the upstream RF signal? How do I measure the downstream power signal from the MC xx card? How do I measure the downstream power signal from the upconverter output? Why is it on GI upconverters the frequency must be set at 1.75 MHz less than the center frequency for a particular NTSC channel? What is meant by "unity gain?" What is the correlation between the minislot size and channel widths? What do the "Show Cable Modem" States mean? What does the"*" and "!" mean for the power level reading on "show cable modem" command? How do I decode the Cable Flap List? Q. How do I measure the upstream RF signal? A. Use the "Zero Span Method" For additional information on this method please see Connecting and Configuring the Cable Headend. 1. Connect the spectrum analyzer to the upstream signal from your cable network at the combiner where all the cable modems connect. 2. Set the analyzer to view the upstream with a center frequency to match the configuration on the CMTS. 3. Set the span to 0 MHz. 4. Set the bandwidth and video channel bandwidth to 3 MHz. Do extended pings. 5. Set the sweep value to 80 micro sec. Push the sweep button, manual, 80, then usec. 6. Activate the trigger line between the highest and lowest portions of the signal. Do this by pushing the trig button, video button, and turn dial down appropriately. 7. Adjust the amplitude so the upper portion of the RF signal is on the top graticule of the display grid and reset the trigger line accordingly. Q. How do I measure the downstream power signal from the MC xx card? A. When measuring the downstream power signal that comes from the cable line card to the upconverter the power measured in dbmv is different depending on which series of line cards you have. For a MCxx "B" card the output is at 32 dbmv +/ 2 db. For a MCxx "C" card the output is at 42 dbmv +/ 2dB.

For a complete table of all the MC cards powers, please click here This is important because not all upconverters have the "autogain" feature that can automatically adjust to the given power and therefore require padding. 1. When measuring the power output from the line card be sure to set the center frequency to 44MHz and and a span of 10 MHz. 2. Turn the Amplitude dial almost to the top so the dbmv setting will read about 10dBmV. 3. Measure the IF signal using the channel power option. 4. Set the channel spacing and channel bandwidth to 6MHz. Press meas/user, power menu, setup. From here you can set channel space and channel bandwidth. 1. Set the video average feature by going to, previous menu, setup, video ave Note: The values doing video averaging are 2.5dB below the actual channel power. For additional information please see the Measuring the Downstream RF Signal Using the Channel Power Option on a Spectrum Analyzer chapter of Connecting and Configuring the Cable Headend Q. How do I measure the downstream power signal from the upconverter output?

A. The objective of this exercise is to make sure that the power from the upconverter of a modulated digital QAM signal is between the range of +50 to +58 dbmv. 1. Connect the downstream output of the cable card to the upconverter input connector. 2. Connect the spectrum analyzer to the RF output of the upconverter. 3. Set the output of the upconverter between +50 and +58 dbmv. 4. Set the center frequency on the spectrum analyzer to match your configuration on the CMTS with a span of 20 MHz. 5. Set the channel spacing and channel bandwidth to 6 MHz. If the RF signal causes an overload or "laser clipping" you need to add attenuation. You will see a sloping of the lines at the sides of the RF signal as seen below. 6. To add attenuation, push the "amplitude" button then the "manual" button, then a value like 10 and then MHz button. 7. Change the spectrum analyzer settings to view the digital channel power. Push "previous menu," then "setup" then "channel power." Here you will be able to see if there is too much power from the upconverter if the value falls outside the range of +50 to 58 dbmv. 8. If the value is outside the required range, adjust the power setting on the upconverter. 1. On a GI upconverter you do this by pushing the down arrow key which selects the mode. Go to the mode with the vertical bars. 2. Then push the right arrow to activate the the bars to blink 3. Now to add db push and hold the up arrow key for 3 seconds. 4. To subtract db push and hold the down arrow key for 3 seconds.

After adjusting the upconverter the spectrum analyzer should read between +50 and +58dBmV. Below it reads 57.06 dbmv.. See also Connecting and Configuring the Cable Headend Q. Why is it, on GI upconverters, that the frequency must be set at 1.75 MHz less than the center frequency for a particular NTSC channel? A. The GI C6U has been set to work off the standard Video Carrier (blue signal) frequency for many years The reason that they did that is because the video carrier had the higher amplitude in the channel. With data channels (represented by the purple signal), the standard is to use the center frequency to represent that channel. The reason is that the data signals are flatter through the 6MHz channel. The difference between the center frequency and the Video Carrier is 1.75MHz. Look at both video and data signals from the spectrum analyzer represented in the pictures below.

Q. What is meant by "unity gain?" A. Unity gain is a concept in which all the amplifiers in a cascade are in balance with their power (dbmv) inputs and outputs. To achieve "unity gain" the receiver output must be adjusted either by padding or attenuation in the node to the proper level determined by the RF input. The RF section or the node is then adjusted to the output levels that give optimal noise and distortion performance for the RF plant. Usually, the outputs of all subsequent amplifiers following the node will be set to the same levels. Thus, we can say that the plant is aligned where the gain factor between a common reference point at each amplifier equals one. For the forward plant, the unity gain point is the amplifier output. Q. What is the correlation between the minislot size and channel widths? A. The minislot size and the channel width are related to certain degree but not really tightly coupled. You may already know that minislot size is in units of ticks, and each tick is defined to be 6.25 us (us = microseconds) The channel width is just another way of saying symbol rate. They are related in a sense that with modulation format (QPSK or 16 QAM) fixed, the higher the symbol rate, the more symbols can fit a chosen minislot size. For example, assuming Quadrature Phase Shift Keying (QPSK), a minislot of 8 ticks can carry 64 symbols at 1280 ksym rate, or 128 symbols at 2560 ksym rate. Thus the minislot size can also be expressed in

terms of symbols or bytes. But changing of symbol rate does not always imply changing of minislot size, unless a certain minislot size is not valid after the symbol rate change. The minislot sizes are lower bounded by the DOCSIS, that is to say 32 symbols, and upper bounded by Broadcom CMTS PHY chip (BCM3137), that is to say 256 symbols. So all the possible minislot sizes are as follows: QPSK 16 QAM 2560 1280 640 320 160 2560 1280 640 320 160 (ksym/s) (us) (ticks) (bytes) (bytes) 12.5 2 8 16 25 4 16 8 32 16 50 8 32 16 8 64 32 16 100 16 64 32 16 8 128 64 32 16 200 32 64 32 16 8 128 64 32 1 400 64 64 32 16 128 64 32 800 128 64 32 128 64 So, if your CMTS is at QPSK, 1280 ksym rate and 8 ticks minislot size, and then you change the sym rate to 640 ksym, the minislot size is still valid. But if you change the sym rate to 320 ksym, the minislot size becomes invalid; if this occurs, the CMTS will change the minislot size accordingly. Q. What do the "Show Cable Modem" States mean? The following list provides all the possible states of a cable modem and what they mean. offline modem considered offline init(r1) modem sent initial ranging init(r2) modem is ranging init(rc) ranging complete init(d) dhcp request received init(i) dhcp reply received; IP address assigned init(o) option file transfer started init(t) TOD exchange started

online modem registered, enabled for data online(d) modem registered, but network access for the CM is disabled online(pk) modem registered, BPI enabled and KEK assigned online(pt) modem registered, BPI enabled and TEK assigned reject(m) modem attempted to register but was refused due to bad mic reject(c) modem did attempt to register; registration was refused due to bad COS reject(pk) KEK modem key assignment rejected reject(pt) TEK modem key assignment rejected If cable modems are not online, you can read Troubleshooting ubr Cable Modems Not Coming Online Q. What does the "*" and "!" mean for the power level reading on the "show cable modem" command? A. The "show cable flap list" and the "show cable modem" can indicate when the Cisco ubr7200 has detected an unstable return path for a particular modem and has compensated with a power adjustment. An asterisk (*) appears in the power adjustment field for a modem when a power adjustment has been made. An exclamation point (!) indicates that a cable modem increased its power level to the maximum level. For Cisco cable modems that equals 61 dbmv. Q. How do I decode the Cable Flap List? A. Here is a simple explanation of how to decode the "show cable flap" output on Cisco's CMTS. One thing to keep in mind is that the flap list is simply a "event detector" and there are three situations that can cause an event to be counted. They are: Reinsertions Hits/Misses Power Adjustments 1. Reinsertions First, we might see flaps along with insertions if a modem has a registration problem and keeps trying to quickly reregister over and over. The P Adj column may be low. When the time between two initial maintenance reregistrations by the cable modem is less than 180

seconds, you'll get "flaps" along with "insertions." Therefore, the flap detector will count it. This default value of 180 seconds can be changed if desired: router(config)#cable flap list insertion time? <60 86400> Insertion time interval in seconds 2. Hits/Misses Secondly, the flap detector will count a flap when we see a "miss" followed by a "hit". Event detection is counted in the "Flap" column only. These polls are hello packets that are sent every 30 seconds. If we get a "miss" followed by a "miss" the polls will be sent every second for 16 seconds attempting vigorously to get a response. If we get a "hit" before the 16 seconds are up, you'll get a flap but if you don't get a "hit" for 16 polls, the modem will go off line in order to begin initial maintenance all over again. If the modem finally comes back online, you'll get an "insertion" because the cable modem inserted itself back into an active state. The flap count is incremented if there are 6 consecutive misses. This default value can be changed if desired: router(config)#cable flap miss threshold? <1 12> missing consecutive polling messages 3.Power Adjustments Finally, the flap detector will show a "flap in the list when we see power adjustment activity. Event detection is counted in the P Adj columns and the "Flap" column. The station maintenance poll constantly adjusts the cable modem transmit power, frequency, and timing. Whenever the power adjustment exceeds 2 db then the "Flap" and the P Adj" counter is incremented. This suggests upstream plant problems. The threshold default value of 2 db can be changed if desired as follows: outer(config)#cable flap power adjust threshold? <1 10> Power adjust threshold in db Related Information Technical Support Cisco Systems All contents are Copyright 1992 2003 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.