alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS
Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology equipment. The safe construction makes sure that persons or objects are not endangered. Do not open the unit, only permit repairs by authorised specialists! Do not use or install your unit in rooms with explosive material! Do not touch the device terminals with metallic or sharp objects! The connection cables of the unit may only be plugged into the designated sockets! In case the unit is damaged, it may not be put into operation, there is an immediate danger to life because of an electric shock. In case the power supply unit is damaged, you should first remove the fuse of the respective electric circuit in order to be able to remove the power supply unit without danger and replace it by another unit, if necessary! Protect the unit from heat sources and direct sunlight! Protect the unit from dust, humidity, aggressive liquids and steam! The unit may only be connected to approved accessories! The unit should only be passed on to a third party including complete operating instructions! When the DSL modem alpha DSL WTM HS has reached the end of its service life, it has to be disposed of in an environmentally friendly manner! Warning! This is a device of class A. These device can cause radio interferences in living area; in that case by operator can require correct things to do. 2
alpha DSL WTM HS alpha DSL WTM HS 1 2 3 LEDs: 1 DSL LED for the condition of the DSL connection 2 Pwr. LED for the power supply extern 3 PoE LED for the power supply Power over Ethernet (PoE) Version see type plate: version alpha DSL WTM HS A for ITUG.992.1 Annex A version alpha DSL WTM HS B for ITUG.992.1 Annex B (G.dmt 1TR112 (UR2)) Checking the content of the package Delivery scope: DSL modem alpha DSL WTM HS with power connector 4 rubber feets instructions for use 3
Connection Connecting the alpha DSL WTM HS In the following picture you can see how you have to cable the alpha DSL WTM HS: Splitter to PC to power supply 1. Connect LAN socket at alpha DSL WTM HS as well as LAN socket at PC (network card/ optionally switch / hub) or router with first RJ45 patch cable. 2. Connect splitter as well as alpha DSL WTM HS with second RJ45 patch cable (unshielded cable useable). 3. Connect power supply cable to power connector and then plug in to alpha DSL WTM HS. Note: The power supply also can made means PoE (Power over Ethernet) via the LAN connection. Are both power supplies active, the external power supply via Power is dominant to PoE (Power over Ethernet). If one power supply failed, the second power supply guarantee the energy supply of the unit (power supply redundance). Deviation from given voltage can lead to the destruction of the alpha DSL WTM HS. 4
Connection Connecting sockets The alpha DSL WTM HS has the following connecting sockets: alpha DSL WTM HS DSL Pwr. PoE 1 DSL 2 LAN 3 Power 10-60VDC 1,0 A 1. DSL connecting socket RJ45 for the connection to the DSL splitter Assignment of the DSL connecting socket Contact PIN Assigned with 1,2,3 not used 4 DSL signal 5 DSL signal 6,7,8 not used PIN 1 PIN 8 5
Connection 2. Ethernet connecting socket RJ45 / standard Ethernet connection for computers or network devices with 10 or 100 Mbit/s Assignment of the LAN connecting socket: Contact PIN Assigned with 1 RX+ (Receive +) 2 RX- (Receive -) 3 TX + (Transmit +) 4 not used 5 not used 6 TX (Transmit -) 7,8 not used PIN 1 PIN 8 3. Power connecting socket for power supply Contact PIN Assignment of the Power socket: Assigned with 1 + 10... 60 V 2 0 V (COM) 3 not used 4 not used Power 10-60VDC 1,0 A PIN 4 PIN 1 6
Mounting alpha DSL WTM HS Mounting By means of the DIN rail holder mounted on the alpha DSL WTM HS, it is possible to attach the alpha DSL WTM HS on a DIN rail TS 35 according to DIN EN 60715. The rubber feets that are included in delivery can sticked under the housing, so it s possible to use the alpha DSL WTM HS as desktop device (the DIN rail holder can dismount after loosing the back plate). DIN hat rail TS35 rubber feet 7
Putting into operation Putting into operation and LEDs If the alpha DSL WTM HS is configured as a modem, the following unit (PC or router) apply to contact by PPP to a provider. The driver required for this has to be installed and activated on the PC to which the alpha DSL WTM HS is connected. Note: The PPPoE driver for current Windows versions can be downloaded e.g. from the website www.raspppoe.com. After correct cabling of the alpha DSL WTM HS, the following status indications should be visible at the front of the alpha DSL WTM HS (see picture page 3): Status indication Pwr. DSL blinking DSL glowing permanently PoE Meaning Supply voltage available, alternativ zu PoE DSL training / dialogue between alpha DSL WTM HS and exchange / max. 10 min alpha DSL WTM HS is registered, training / synchronisation with exchange is terminated without data error Power over Ethernet active 8
Troubleshooting Troubleshooting Status indication Possible cause Measures No power LED is glowing. DSL - not blinking 40 s after correct connection. DSL blinking longer than 10 min. The alpha DSL WTM HS has no power supply. DSL connection faulty Connection cable defective or not inserted correctly 1. Check the correct cabling between alpha DSL WTM HS and one of the power supplys 2. The alpha DSL WTM HS has to be exchanged. 1. Check the cable connection at splitter and alpha DSL WTM HS / cable shall snap safely into place 2.Contact provider Check the connection cable or the patch cable between alpha DSL WTM HS and splitter 9
Conformity Conformity Herewith, the FMN communications GmbH that the alpha DSL WTM HS complies with the essential requirements and the other relevant provisions of the directive 1999/5/EG (R&TTE directive). The conformity with the above mentioned directive is confirmed by the CE symbol on the alpha DSL WTM HS. The complete declaration of conformity can be found in the Internet under http://www.fmn.de 10
Maintenance / Technical data Maintenance No maintenance is necessary at the alpha DSL WTM HS. In case the mains supply is switched off the alpha DSL WTM HS can be cleaned with an antistatic cloth or with a soft, dry cloth. The alpha DSL WTM HS may only be repaired by the manufacturer or by authorized specialists. Technical data of the alpha DSL WTM HS Dimensions (W x D x H): ca. (49 x 146 x 105) mm (with DIN rail holder) Protection class: IP 20 Operating voltage: 10... 60 VDC Maximum power consumption: 13 W bei 12 V Average power consumption: 9 W bei 12 V Operating temperature: -25 C... +55 C DSL transmission rate: max. 24 MBit/s (Downstream), 1 MBit/s (Upstream) Software (firmware) can only be updated by the manufacturer or authorized specialists Compliant to CE Connections and interfaces DSL connection according to standard ITU G.992.1 Annex B (G.dmt), T-Com 1TR112, ANSI T1.413, ITU G.994.1 (G.hs) / Annex A Network connection over RJ45 socket (standard Ethernet, 10/100 Base-T) Abbreviations ATM... Asynchronous Transfer Mode DSL... Digital Subscriber Line PPP... Point to Point Protocol PPPoE... Point to Point Protocol over Ethernet PPPoA... Point to Point Protocol over ATM Copyright All rights reserved. Duplication of these instructions for use or parts thereof by any reproduction method whatsoever is not permitted without prior permission of the manufacturer. Amendments may be published without prior notification. Notwithstanding the above declaration, the manufacturer accepts no liability for errors in these instructions or their consequences. 11
For the protection of the environment! Printed on paper bleached without chlorine, with a maximum waste paper content of 50 %. FMN communications GmbH Grimmelallee 4 99734 Nordhausen/Germany P. O. Box 10 04 65 99724 Nordhausen/Germany Phone +49 (36 31) 56-50 00 Fax +49 (36 31) 56-32 24 Email info@fmn.de Internet www.fmn.de HOTLINE +49 (36 31) 56-34 16 We are at your disposal to answer your questions. Subject to change. alpha DSL WTM HS 0116.3.0061.00 Edition: 08/09 (1111-5735)