tough. durable. friedrich.



Similar documents
Room Air Conditioners

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

Thru-the-wall AIR CONDITIONERS COOL ONLY HEAT PUMPS ELECTRIC HEAT

ROOM AIR CONDITIONERS

I N T R O D U C I N G. COMMERCIAL GRADE DURABILITY with BUILT-IN, 7 DAY PROGRAMMABLE THERMOSTAT

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SPECIFICATIONS. Cooling Capacity BTUH 5,200. Approx. Sq. Ft. Cooling EER 9.7 Heating Capacity BTUH N/A (electric)

Two-Stage Air Conditioner with Puron Refrigerant

Two-Stage Air Conditioner with Puron Refrigerant MODEL 180B

Single Package Vertical Air Conditioners. Vert-I-Pak

ARMSTRONG AIR HEAT PUMPS

PACKAGED TERMINAL AIR CONDITIONERS

FOXAIR 60/50 ALL MODELS

Submitted to Reference Approval Construction Unit Designation Schedule #

CoastGuard Two-Stage Air Conditioner with Puron Refrigerant

Portable Air Conditioner

Series. Air Conditioners. Two-Stage, Extra-Efficient Air Conditioners with up to 21.0 SEER. Infinity

USER S MANUAL HSC-24A

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

ROOM AIR CONDITIONERS

SECTION HEAT PUMPS

Service & Parts Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

2010 Duct-Free Splits Line Card

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

WINDOW ROOM AIR CONDITIONER

Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

york air-conditioning products Residential & VRF News 2015

Evolution Extreme Heat Pump

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT. READ ONLY

Installation Instructions For Slider Casement Air Conditioners

ECO-AIR AIR CONDITIONING

Installation Instructions

FTXS. Wall Mount Heat Pump or Cooling Only

Air Conditioners. A cool, comfortable solution to take you to a higher standard of comfort. READ ONLY

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

Local Dealer:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Energy Efficiency. Energy Efficient Home Cooling:

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

MAC-120HE-01 Air-Cooled Chiller

TIPS ON ENERGY SAVING

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

The XP17 provides comfort without comparison.

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

air conditioners how to choose a cooling system

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT.

ECOCIAT. Domestic hot water heat recovery unit

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Commercial Gas Furnace Upflow

Glossary of Heating, Ventilation and Air Conditioning Terms

SiUS Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

3Aftermarket Systems. Air Conditioners and Kombos Heater/Pressurizer System Matrix Aftermarket System Requirements...

Single Zone LCD Thermostat Operating Instructions

MovinCool Office Pro Series. The Portable Spot Cooling Solution

Instruction manual for Firstline FCS12000CH

AIR CONDITIONING and HEAT PUMP PRODUCTS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Low Profile Unit Cooler

Split Type Room Air Conditioner. KSWM units

Unico Inverter. Unique and efficient.

FTQ. Daikin Inverter Ducted Heat Pump

Samsung Room Air Conditioning

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Standard Heating and Air, Inc Committed to Excellence

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

FHQ. Ceiling Suspended Heat Pump or Cooling Only

Innovation in air conditioning and heating

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Model. Roof-Top Air Conditioner CARAVAN MODEL B3200 TYPE INSTALLATION & OPERATING INSTRUCTIONS B3200

DUCTED AIR CONDITIONING SOLUTIONS

PTAC Preventive Maintenance Guide. Step-by-step instructions and information to keep your units operating in peak condition

FCQ. Roundflow Cassette Heat Pump or Cooling Only

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

Transcription:

tough. durable. friedrich. ROOM AIR CONDITIONERS 2003 LINE EST. 1883

Dear Friedrich, I wanted to say thank you for producing a VERY durable room air conditioner. The other night, my daughter asked me to close the upper part of the window before turning on the air conditioner. It was dark, and yes, I did not turn on the light and lifted the wrong part of the window. YES, you guessed it, the air conditioner went out the second floor window and into the garden below. The next day I checked the unit and it did not look too bad. I removed the cover and re-attached the power cord. When I plugged it in and turned it on... It worked perfectly... cool air was flowing. My compliments to the Friedrich Company for building a sturdy and durable air conditioner. We currently have three Friedrich air conditioners and I will continue to purchase only Friedrich in the future. Sincerely, Michael Williamson Hillsdale, NJ Friedrich is durable and rugged We have to be. We have tough customers. Oil companies rely on us to cool offshore oil rigs safely and reliably year after year in the most extreme conditions. And, Friedrich products cool military bases and government offices all over the world. Most importantly, we condition over a million homes just like yours. Tough customers. Tough products. That s Friedrich. Individually crafted using only the highest quality components Friedrich air conditioners are crafted from superior components like high efficiency compressors, totally enclosed fan motors, sound-isolating extra thick rubber grommets, pure copper coils, heavy duty side curtains and durable galvanized steel. Our units also receive an automobile-quality paint job. All of these extra considerations help ensure that you f r i e d r i c h t i m e l i n e Ed Friedrich goes into business, making store fixtures, billiard tables & carved cabinetry Friedrich store expansion Fire forces plant relocation Friedrich enters food display case business 50th Anniversary Prosperity Tour in gold car George Friedrich invents Floating Air revolutionizing refrigeration Now one of the world s largest manufacturers of commercial refrigeration equipment Wright Brother's First Flight Ford mass produces automobiles Empire State Building opens *Electronic models only

are purchasing an air conditioner that will deliver years of quiet, dependable, energy efficient operation. Over 40 production line inspections ensure performance Every Friedrich air conditioner is put through a rigorous battery of tests and quality checks before leaving the factory. We are not satisfied with less than the best. You shouldn t be either. 120 years of excellence While many new names are entering the room air conditioner business, Friedrich has been making products of uncompromising quality since 1883. We introduced our first room air conditioner in 1952. From that time on, Friedrich has developed a reputation for building durable, high-quality air conditioners with exceptional energy efficiencies. Friedrich was also the first to bring easy-to-use electronic controls to room air conditioners. Friedrich is an ENERGY STAR Partner Our focus has long been on energy efficiency. We re a charter member with the U.S. Dept. of Energy and the Environmental Protection Agency in the Energy Star Program. Energy Star encourages the use of energy efficient appliances to help preserve our natural resources, while saving money on utility bills. www.energystar.gov First window air conditioner comes off assembly line New headquarters opens Friedrich begins making packaged terminal air conditioners Friedrich adds single package vertical line of air conditioners 120th Anniversary Neil Armstrong walks on the moon Microsoft incorporates 25 million websites AMERICA S BEST AIR CONDITIONER

115 VOLT E L E C T R O N I C por t able models 115 230/208 VOLT E L E C T R O N I C models ENERGY STAR ENERGY STAR XSTAR 24-hour electronic timer lets you program on/off times MoneySaver setting saves energy by cycling the fan with the compressor Three cooling speeds, plus Smart Fan auto-adjusts fan speed to maintain desired temperature Rust proof base pan Slide-out, easy-to-clean filter with antimicrobial treatment for protection against fungal and bacterial growth Auto-memory backup Heavy duty side curtains Stale air exhaust vent QUIETMASTER Electronic Programmable Cooling with the Friedrich Smart Center One-touch cooling 24-hour programmable timer MoneySaver setting saves energy by cycling fan with compressor Four-speed fan with ultraquiet Sleep Setting Filter alert signals you to check filter Smart Fan auto-adjusts fan speed to maintain desired temperature Super high energy efficiency for low operating cost Easy-to-clean filter with antimicrobial treatment for protection against fungal and bacterial growth Auto-memory backup Easy-to-use remote control Lets you control indoor comfort at the touch of a button Remote Control Remote Control Remote control on select models 5,400 to 7,800 BTU/h EERs up to 11.0 8,200 to 20,200 BTU/h EERs up to 11.4

115 230/208 VOLT D E L U X E l S T A N D A R D models 230/208 VOLT L A R G E C A P A C I T Y models ENERGY STAR ENERGY STAR ENERGY STAR QUIETMASTER Deluxe MoneySaver setting saves energy by cycling the fan with the compressor Four cooling speeds, plus Super high energy efficiency for low operating cost Easy-to-clean filter with antimicrobial treatment for protection against fungal and bacterial growth QUIETMASTER MoneySaver setting saves energy by cycling the fan with the compressor Three cooling speeds, plus Super high energy efficiency for low operating cost Easy-to-clean filter with antimicrobial treatment for protection against fungal and bacterial growth QUIETMASTER Heavy Duty MoneySaver setting saves energy by cycling the fan with the compressor Three cooling speeds, plus Super high energy efficiency for low operating cost Easy-to-clean filter with antimicrobial treatment for protection against fungal and bacterial growth Mounts in a window, wall or transom 10,000 to 23,200 BTU/h EERs up to 11.1 10,000 to 23,200 BTU/h EERs up to 10.9 24,600 to 35,000 BTU/h EERs up to 9.7

115 VOLT 115 VOLT C A S E M E N T W I N D O W model S L I D E R / C A S E M E N T models CASEMENT Quiet operation Two-speed cooling, plus Easy-to-clean filter with antimicrobial treatment for protection against fungal and bacterial growth 6,200 BTU/h 8.7 EER SLIDER CASEMENT Quiet operation Three-speed cooling, plus two s Turbo fan provides even cooling Easy access, washable filter 8,000 to 12,000 BTU/h 9.5 EER 115 230/208 VOLT H E A T P U M P l E L E C T R I C H E A T models TwinTemp YQ, EQ TWINTEMP YQ & EQ Two cooling and heating speeds, plus Super high energy efficiency for low operating cost Slide-out, easy-to-clean filter with antimicrobial treatment for protection against fungal and bacterial growth TWINTEMP MoneySaver setting saves energy by cycling the fan with the compressor Three cooling and heating speeds, plus Super high energy efficiency for low operating cost Easy-to-clean filter with antimicrobial treatment for protection against fungal and bacterial growth YQ Heat pump Cool 6,400 BTU/h Heat 5,000 BTU/h EER 9.7 EQ Electric heat model Cool 8,250 BTU/h Heat 4,000 BTU/h EER 9.8 TWINTEMP ES, YS, EM, YM, EL & YL models Cool 9,200 to 35,000 BTU/h Heat 7,400 to 23,000 BTU/h EERs up to 11.5

Room Air Conditioner Specifications ENERGY STAR Qualified Electrical Characteristics (60 Hertz) Energy Cooling Heating Efficiency Moisture Room Side Net Capacity Capacity Volts Cooling Cooling Heating Heating Ratio Removal Air Circulation Weight Model BTU/h BTU/h Rated Amps Watts Amps Watts EER Pints/Hr. CFM Sleeve* Lbs. XSTAR XQ05J10 5400 115 4.6 507 10.7 1.5 160 Q 70 XQ06J10 6200 115 5.1 564 11.0 2.0 160 Q 77 XQ08J10A 7800 115 6.6 729 10.7 1.9 175 Q 80 QUIETMASTER Electronic SS08J10R 8200 115 6.7 745 11.0 2.0 310 S 108 SS09J10C 9000 115 7.4 837 10.8 1.7 300 S 113 SS10J10AR 10200 115 7.5 892 11.4 2.5 260 S 115 SS12J10AR 11750 115 9.8 1068 11.0 3.5 325 S 114 SS14J10R 14000 115 12.0 1308 10.7 4.3 290 S 128 SS12J30D 12000/11800 230/208 5.0/5.2 1091/1026 11.0/11.5 2.8 300 S 114 SS16J30A 16300/16000 230/208 7.5/8.0 1663/1634 9.8/9.8 5.0 330 S 119 SM18J30BR 18300/17800 230/208 8.6/9.2 1892/1828 9.7/9.7 5.7 500 M 163 SM20J30 20200/20000 230/208 9.5/9.9 2082/2000 9.7/10.0 6.1 490 M 154 QUIETMASTER Deluxe RS10J10 10000 115 8.3 909 11.0 2.6 300 S 115 RS12J10A 11750 115 9.8 1068 11.0 3.5 325 S 114 RS15J10 14500 115 12.0 1306 11.1 4.3 290 S 128 RS16J30A 16300/16000 230/208 7.5/8.0 1663/1634 9.8/9.8 5.0 330 S 119 RM18J30A 18300/17800 230/208 8.6/9.2 1892/1828 9.7/9.7 5.7 500 M 163 RM24J30 23200/23000 230/208 11.1/12.2 2468/2447 9.4/9.4 7.0 590 M 192 QUIETMASTER KS10J10 10000 115 9.1 971 10.3 2.8 325 S 108 KS12J10B 11500 115 9.4 1065 10.8 2.5 360 S 111 KS15J10 14500 115 12.0 1330 10.9 4.3 290 S 128 KS12J30B 12000/12000 230/208 5.4/5.9 1200/1176 10.0/10.2 3.5 325 S 106 KM18J30C 18000/17700 230/208 8.3/9.2 1865/1827 9.7/9.7 5.6 500 M 161 KM20J30 20200/20000 230/208 9.5/9.9 2082/2000 9.7/10.0 6.1 490 M 154 KM24J30 23200/23000 230/208 11.1/12.2 2468/2447 9.4/9.4 7.0 590 M 192 QUIETMASTER Heavy Duty SL25J30 24600/24400 230/208 11.5/12.6 2536/2515 9.7/9.7 6.9 625 L 192 SL28J30B 28000/27700 230/208 13.0/14.2 2947/2916 9.5/9.5 8.7 650 L 201 SL35J30 35000/34800 230/208 18.0/20.0 4070/4047 8.6/8.6 11.0 775 L 220 TWINTEMP Heat Pump YQ06J10B** 6400 5000 115 5.9 658 5.8 641 9.7 1.8 135 Q 78 YS09J10B** 9200 7400 115 7.3 800 6.6 718 11.5 1.7 300 S 113 YS12J33 12400/12200 11300/11000 230/208 5.2/5.6 1181/1140 5.2/5.5 1177/1122 10.5/10.7 3.5 325 S 117 YM18J34B 18000/18000 17600/17600 230/208 9.1/10.0 2000/2000 8.9/9.8 1958/1958 9.0/9.0 5.2 495 M 166 YL24J35C 24000/24000 23000/23000 230/208 10.9/12.0 2400/2400 11.0/12.1 2421/2421 10.0/10.0 6.0 600 L 198 TWINTEMP Electric Heat EQ08J11 8250 4000 115 7.5 842 11.2 1290 9.8 2.1 160 Q 76 ES12J33B 12000/11800 10700/8900 230/208 5.0/5.2 1091/1026 16.0/14.7 3500/2900 11.0/11.5 2.8 300 S 111 ES16J33A 16300/16000 10700/8900 230/208 7.5/8.0 1663/1634 16.0/14.7 3500/2900 9.8/9.8 5.0 330 S 116 EM18J34B 18300/17800 13000/10600 230/208 8.6/9.2 1892/1828 19.5/17.0 4200/3500 9.7/9.7 5.3 500 M 160 EL25J35 24600/24400 17300/14300 230/208 11.5/12.6 2536/2515 24.0/22.4 5500/4650 9.7/9.7 6.9 650 L 191 EL35J35 35000/34800 17300/14300 230/208 18.0/20.0 4070/4047 24.0/22.4 5500/4650 8.6/8.6 11.0 775 L 220 SLIDER CASEMENT SV08A10 8000 115 7.7 840 9.5 2.3 247 SV 66 SV10A10 10000 115 9.6 1050 9.5 3.2 282 SV 77 SV12A10 12000 115 11.5 1260 9.5 3.4 282 SV 79 CASEMENT SC06H10D 6200 115 6.7 715 8.7 2.0 140 SC 70 *Sleeve dimensions listed on following page. **The YQ06 and YS09 models operate on 115 volts and are not equipped with supplemental heat. Both models will not provide heat at temperatures below 40 F. Friedrich room air conditioners are designed to operate in outdoor temperatures from 50 F to 115 F. As an ENERGY STAR partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR ( ) models meet the ENERGY STAR guidelines for energy efficiency.

Installation Information / Sleeve Dimensions Depth Depth Minimum Minimum Thru-the-wall with Hood to Extension Extension Window Width Finished Hole Sleeve Height Width Front Louvers Into Room Outside Minimum Maximum Height Width Q 14" 19 3/4" 21 3/8" 8 1/2" 5 1/2" 10 3/4" 26" 42" 14 3/4" 20" S 15 15/16" 25 15/16" 27 3/8" 8 3/4" 3 1/16" 16 15/16" 27 7/8" 42" 16 3/16" 26 3/16" M 17 15/16" 25 15/16" 27 3/8" 8 3/4" 3 1/16" 16 15/16" 27 7/8" 42" 18 3/16" 26 3/16" L 20 3/16" 28" 33 5/8" 16 1/2" 3 3/16" 18 15/16" 29 7/8" 42" 20 3/8" 28 1/4" SC 10 13/16" 14 11/16" 27" 9 7/8" 2 1/2" 15 1/2" 14 3/4" 17 7/8" 11 1/8" 14 15/16" SV 20 1/2" 14 1/2" 23" 11" 5 1/4" 17 3/4" 15 1/2" * *SV fits windows a minimum of 21" H and a maximum of 40 1/2" H Circuit Rating Plug Face Appearance Model Breaker or T-D Fuse (NEMA#) (Facing Blades) ALL SV and XQ MODELS, KS10J10, KS12J10B, KS15J10, RS10J10, RS12J10A, RS15J10, SS08J10R, SS09J10C, SS10J10AR, SS12J10AR, SS14J10R, SC06H10D, EQ08J11, YQ06J10B, YS09J10B 125V - 15A 5-15P KS12J30B, KM18J30C, RS16J30A, RM18J30A, SS12J30D, SS16J30A, SM18J30BR 250V - 15A 6-15P KM20J30, KM24J30, SM20J30, SL25J30, SL28J30B*, ES12J33B, 250V - 20A 6-20P ES16J33A, YS12J33 SL35J30, EM18J34B, EL25J35, EL35J35, YM18J34B, YL24J35C 250V - 30A 6-30P * Optional 30 Amp Kit (618-869-00) is recommended in 208 Volt power supply areas that fall below 208 Volts. For more information, call the Friedrich Service Department. Due to a program of continuing improvement, specifications are subject to change without notice. Installation Notes: Supply Cord - All with right angle plug 6' on 115V; 5' on 230/208V. Room air conditioners include accessories for window or thru-the-wall installation. TWINTEMP models include accessories for thru-the-wall installation only. Window mounting requires use of optional accessory kit as listed below: MODEL EQ08J11, YQ06J10B ES12J33B, ES16J33A, YS09J10B, YS12J33 EM18J34B, YM18J34B EL25J35, EL35J35, YL24J35C KIT NO. WIKQ WIKS WIKM WIKL The consumer- through the AHAM Room Air Conditioner Certification Program- can be certain that the AHAM Certification Seal accurately states the unit s cooling and heating capacity rating, the amperes and the energy efficiency ratio. Friedrich Air Conditioning Co. friedrich.com P.O. Box 1540 San Antonio, TX 78295-1540 tel (210) 357-4400 fax (210) 357-4480 RAC-03 (01-03) Printed in U.S.A.