How To Design A Gas Dryer



Similar documents
COMMERCIAL GAS DRYER FUELLED BY TOWN GAS CODE OF PRACTICE GU13 (MODULE ONE)

DRYER VENTING SPECIFICATIONS DRYER SAFETY

SPECIAL APPLICATIONS

Safe Method: Gas Safety in Catering Establishments

Operating instructions

COMMERCIAL GAS DRYER FUELLED BY LIQUEFIED PETROLEUM GAS CODE OF PRACTICE GU13 (MODULE TWO)

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Guidance notes to the CER s recently enacted Gas Works Regulations. These Guidance Notes should be read in conjunction with:

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Portable Air Conditioner

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

IGEM/UP/16 Communication 1756

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

HEAVY DUTY STORAGE GAS

Cabinet heater. Gas fired cabinet heater with atmospheric burner for indoors installation for free blowing applications or connection to ductwork

Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales

Operating instructions

UDSA - UDSBD unit heater

PORTABLE AIR CONDITIONER

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

SL280UHV SERIES GAS FURNACE WARNING

SWIMMING POOL HEAT PUMP

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

orlando OWNER S MANUAL

HVAC Code Requirements

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Fumigation of Safety Cabinets

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Exhaust Calculation Booklet

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Technical Bulletin 005(A) Developed with Communities and Local Government

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

G670 Intermittent Pilot Ignition Controls

2014 British Columbia Building Code Changes

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Technical Bulletin 025

Energy Saving Fact Sheet Boilers

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Element D Services Plumbing

Getting the best from your urn

HEAT WAVE DUCT KIT KIT #

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

B-1 Buildings & Service Maintenance

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

Gas and Oil Fired Space Heating

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

plumbing products guide

Spray Booth Guideline

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

NORSOK STANDARD H-001 Rev. 4, Nov Heating, ventilation and air-conditioning

HeatSource HS1800 Heater

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Use and Care Manual. Model CPA12KH AIR CONDITIONER

AZB 800. Vertical Flue Gas Ducting Ø60/100mm

INFRARED QUARTZ WALL HEATER

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Cooling Capacity CFM in. w.c. (125 Pa)

Fire Protection Notice No. 9 ELECTRICAL SAFETY

GTC Technical Guidelines - Gas

RPV - RP - RA air handling units

Utilities and existing services

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Heat Pump Installation, Maintenance and Service Manual

bout your HOUSE before you start Renovating Your Basement Moisture Problems

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

User's Instructions. Alpha HE CB25/33 and HE SY25

Oil and Coolant Circulating Heating System. Model - OCSM

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Technical Bulletin 140 Developed in conjunction with the Institution of Gas Engineers and Managers (IGEM)

REPLACEMENT AIR CONDITIONING UNITS FOR BRITISH EMBASSY RESIDENCE

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

bout your house before you start Renovating Your Basement Moisture Problems

RECON WATER HEATER INSTALLATION FORM

During Various Aluminum Fabricating Operations

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Energy Efficiency HOSPITALITY.

CARING FOR YOUR WATER HEATER

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

SIZING AND CAPACITIES OF GAS PIPING

COMMERCIAL GAS AND ELECTRIC STACKED WASHER/ DRYER INSTALLATION INSTRUCTIONS

Routers and machining centres

AIR-CONDITIONER SPLIT TYPE

INSTALLATION REQUIREMENTS FOR DOMESTIC GAS WATER HEATERS ( RATED HEAT INPUT UP TO 70 kw )

Building Services Engineering Technician

The space saving solution.

Baxi Combi 80e & 105e

Transcription:

Non Domestic Laundry Gas Appliance Installation Code of Practice Introduction This code of practice has been produced with the assistance of all Companies within the OPL sector of SLEAT because of the concerns for safety within the industry. It had become quite obvious that there was not a clear understanding of how a gas appliance within the non domestic laundry sector worked and whilst the combustion requirement was considered, the drying needs weren t. This code of practice goes to explain and quantify these details and is for use by the installer, maintainer and operator alike. It must be used in conjunction with manufacturers instructions. It is very important that this document is read fully before undertaking any work so that all areas of installation are carefully considered and a suitable risk assessment undertaken so the most appropriate location is found for the appliance and compliance with all services ensured. Gas work All gas work must be carried out by a business that is CORGI registered and using gas operatives who hold competency certification in the work to be undertaken. All gas work must conform to the Gas Safety (Installation & Use) Regulations as amended. Gas Supply All gas pipework must be installed in accordance with the Institution of Gas Engineers (IGE)UP/2 and (LPGA) COP22 and tested and purged in accordance with (IGE)UP/1A or (LPGA) TM62 for LP gas. The piping must be adequately sized to supply gas to each appliance and for the total consumption of gas appliances in the premises. In the main the laundry supply pipework does not need to exceed 28mm, if it does due consideration must be given as the maintenance operatives may require additional gas competencies to work on the installation. Each appliance must have its own readily accessible isolation valve for servicing purposes. Where multiple machines are installed a readily accessible means of isolating all the gas in the room must be provided. This must not be located inside an enclosure. The final connection to the appliance should be by means of a gas hose that is manufactured to BS669 part 2 or a double armoured style of hose, sheathed or unsheathed dependant on location, suitable for the family of gas utilised. It must allow a sufficient volume of gas to flow for the safe and correct operation of the appliance. An appropriate means of fixing the appliance must be made so as to prevent the hose being subjected to unnecessary strain. 1 SLEAT issue 7ii

Electrical Services All electrical wiring must conform to BS7671 as amended and reference will need to be made to the manufacturer's instructions to ensure correct final connection to the machine and suitable for the specific location. Exhaust The exhaust ducting is intended to remove the products of combustion and the air and water vapour used in the drying process. Commonly the dilution of air to products of combustion mix is in excess of 1:40. The method and design of the ducting for the exhaust will have a major effect on the efficiency of the installed appliances. It will be noted from table 1 that this type of equipment requires a substantial amount of fresh air for correct operation and this must be removed through the exhaust duct and discharged to outside atmosphere in a safe and satisfactory position. The design of the exhaust system must therefore take account of the following: It must terminate to outside atmosphere in a safe and satisfactory position It must present a minimal resistance to airflow It must be of smooth bore metal construction, as short as possible and with the minimum of bends and changes in direction. It must be capable of withstanding the temperatures generated, commonly between 40 o and 82 o c. It must include provision for internal access for cleaning and maintenance. Appliance Connection A very short length flexible ducting as specified by the appliance manufacturer, may be utilised to make the final connection to the appliance. This must not exceed 2m in length and be capable of withstanding the maximum known output temperature. The internal bore of the flex section however, must be maintained throughout its length i.e. it must not be kinked or deformed. It must not be used to change direction. Ductwork The ideal design is a straight, short smooth bore duct pipe from the outlet of the appliance directly to outside atmosphere at the outlet level of the dryer with a down turned terminal and no grille. In all cases, the manufacturer's installation instructions must be followed. The exhaust duct must be adequately supported throughout its entire length and all joints must be sealed. Where sections are joined there must be minimal intrusions into the 2 SLEAT issue 7ii

airflow i.e. keep any self-tapping screws as short as possible so that they will not restrict airflow or act as an obstruction, gathering lint etc. There will be lint in small quantities moving with the airflow and for this reason neither filters in the flow nor grilles are recommended as they will impair airflow and lead to further problems and may pose a fire hazard. Where the design is to be a single duct for multiple dryers the minimum overall cross sectional area of the duct must not be less than the total sum of the cross sectional areas of all the dryer exhaust outlets. Suitable inspection openings for the removal of lint are required along the ductwork where appropriate. Termination The termination in outside atmosphere can have a detrimental effect on the overall efficiency of the equipment if this impairs the airflow and for this reason an open method must be adopted that prevents ingress of weather, whilst protecting the airflow from prevailing winds. DO NOT fit any grille or restrict the outlet in any way either at the termination or at any point along the ducting Diagram I A 45 or 90 o elbow (as per diagram I) may be used to achieve this. A minimum clearance of 300mm from ground level should be provided. The termination must be at least 300 mm and should ideally be 2m from any opening or fresh air inlet into the building (as per diagram II). The configuration of the exhaust termination in respect of the make up air inlet grille should not allow recirculation of the exhausted damp warm air back into the make up air vent. 3 SLEAT issue 7ii

NB. Every precaution should be taken to prevent damp, warm exhaust air from recirculating through the make up air grille Diagram II Exhaust testing Testing airflow, as indicated in the manufacturers specification must be carried out to check that the ducting is within the specified parameters. The exhaust system must be tested to ensure that all products of combustion and water vapour etc. are being removed to outside air. The airflow pressure measured must be less than 1.25mb (0.5 WG) when tested in the exhaust ducting within 500mm from the appliance with it operational and at normal running temperature. In the case where more than one appliance is connected to a common duct, the system should be tested for its exhaust capabilities, with one appliance in operation, and again with all appliances working and all non permanent openings closed ie doors, windows &c.. During the test(s) any other air extraction systems in the vicinity must be operating at maximum and where they can be operated in extract or induce modes, the tests must be carried out in both modes i.e. in worst case conditions Ventilation - Make Up Air This equipment moves large amounts of air to achieve the drying process as can seen from the table below. Careful consideration must be given to ensure that clean, cool air is introduced directly from the outside atmosphere to allow the drying process to occur whilst ensuring suitable levels of air for combustion. Air for combustion of the gas, commonly takes around 2-6% of the total air volume required. There will also be loose lint that is ejected through the exhaust system and consideration must be given to ensure that this is not allowed to build up in any ventilation system or openings so that it either blocks the incoming flow or causes a fire hazard. 4 SLEAT issue 7ii

The Make Up Air inlet vent must be at least 300mm and ideally should be 2m away from any exhaust point to prevent wet, warm air being re-introduced into the system. Where extract fans or similar are installed the effect on exhaust and make up airflow must be considered. It must not adversely affect the operation of the equipment or alter the safety of other equipment either in that room or adjacent rooms in a detrimental way. Where the Make Up Air supply utilises input fans or similar, these devices must be positively interlocked with a manual reset in the gas supply so as to prevent combustion taking place in the dryer in the event of a failure Generic model Air flow Minimum Free Air Ventilation Size 13kg (30lb) 9.9 19.8 m 3 /min (350 700 ft 3 /min) 1000 cm 2 (155 in 2 ) 23kg(50lb) 19.8 22.7 m 3 /min (700 800 ft 3 /min) 1500 cm 2 (233 in 2 ) 34kg(75lb) 22.7 32.6 m 3 /min (800 1150 ft 3 /min) 2250 cm 2 (349 in 2 ) Table I The 'minimum free air' refers to a permanent non-closable supply of air, available directly or via ducting from outside atmosphere. Any obstructions such as louvres or grilles must be deducted from the overall size of a vent and the vent increased in physical size until the minimum size is achieved. It is acceptable to oversize the make up air. It is also worth noting that there is a model of dryer marketed called a stacker, stack dryer or similar. This refers to a piece of equipment where two dryers are mounted in one case on top of each other. Sometimes to highlight the matter the individual units are called 'pockets'. In any event, for installation purposes, each 'pocket' must be considered as an individual dryer, and the make up air must be allowed for each 'pocket. Commissioning The appliance(s) must be commissioned in accordance with the manufacturers instructions and statutory regulations. Testing and purging of the appliance, downstream of the appliance isolation valve must be carried out using an appropriate method. This may be using leak detection fluid if the pipework has not been dismantled and you have no reason to believe that there is an unsafe situation nor can you smell gas. The exhaust system must be tested to ensure that it is effectively removing the products of combustion safely to outside atmosphere. Throughout this process due care must be given to any unsafe situations and full inspection during commissioning is appropriate to ensure no dangers exist or could exist. Necessary action must be taken if an immediately dangerous or at risk situations are encountered and further details can be found in the Gas Industry Unsafe Situations procedure available from CORGI publications. Appropriate documentation, duly signed must be completed before leaving site. 5 SLEAT issue 7ii

Normative Documents 1. The Gas Safety (Installation & Use) Regulations 2. The Building Regulations Approved Document. 3. BS 669 part 2 4. Manufacturer's Installation Specifications 5. BS 7671 (16 th edition IEE regulations) 6. Institute of Gas Engineers UP/1A and UP/2 7. LPGA code of practice (COP) 22 8. TM62 technical detail on soundness testing for LP gas installations 9. The Gas Industry Unsafe Situations procedure 10. Local bye - laws 6 SLEAT issue 7ii

GLOSSARY BSI British Standards Institute Commissioning Putting appliance into operation as per manufacturers specification CORGI The Council for Registered Installers Dilution Mixture of products Duct The pipe used to transmit products of combustion together with the supersaturated warm drying air to atmosphere Exhaust Duct Single walled pipe the means of removing the moist air to atmosphere Free air The area of unrestricted ventilation opening IGE Institute of Gas Engineers LPGA Liquefied Petroleum Gas Association Make Up Air Air required to replace that which is used in the combustion and drying process Permanent Unable to reduce or restrict commonly referred to as fixed without a tool Products of Combustion Mixture of waste gases as a result of combustion commonly referred to as POC SLEAT Society of Laundry Engineers and Allied Trades 7 SLEAT issue 7ii

Acknowledgements To all those who helped and proof read this document and offered input, not forgetting those outside bodies who offered words of wisdom, our grateful thanks. Current details can be obtained from the SLEAT website www.sleat.co.uk or by contacting the Secretary directly You do not have to be a SLEAT member to take advantage of the ACS courses arranged through SLEAT. The Society of Laundry Engineers And Allied Trades Limited Suite 7 Southernhay 207 Hook Road Chessington Surrey KT9 1HJ Tel: 020-8391 2266 Fax: 020-8391 4466 Email: admin@sleat.co.uk 8 SLEAT issue 7ii