Gigabit Ethernet 1000BASE-T. Whitepaper. Copyright 1997 Gigabit Ethernet Alliance



Similar documents
1000BASE-T: Gigabit Ethernet over Category 5 Copper Cabling

WHITE PAPER. 1000BASE-T: Gigabit Ethernet over Category 5 Copper Cabling Technical Fundamentals

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Twisted-pair Ethernet:

Gigabit Ethernet on Copper Cabling Infrastructures

Data Communications Competence Center

1000BASE-T: Gigabit Ethernet. over Category. 5 copper. cabling. Acronyms and abbreviations

INTRODUCTION TO 100BASE-T: FAST (AND FASTER) ETHERNET

Enhanced Category 5 Cabling System Engineering for Performance

Fast Ethernet and Gigabit Ethernet. Networks: Fast Ethernet 1

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

Fast Ethernet and Gigabit Ethernet. Computer Networks: Fast and Gigabit Ethernet

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

Introduction to Digital Subscriber s Line (DSL)

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Gigabit Ethernet: Architectural Design and Issues

Nexus Technology Review -- Exhibit A

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Network Design. Yiannos Mylonas

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

Objectives. Lecture 4. How do computers communicate? How do computers communicate? Local asynchronous communication. How do computers communicate?

EECC694 - Shaaban. Transmission Channel

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Transmission of High-Speed Serial Signals Over Common Cable Media

Advanced Signal Processing 1 Digital Subscriber Line

EoVDSL: A Cost-Effective Solution for Transmitting Ethernet Data Over Existing Copper Wiring for ITS and Traffi c Applications

2. What is the maximum value of each octet in an IP address? A. 128 B. 255 C. 256 D. None of the above

Chapter 4 Connecting to the Internet through an ISP

How to Choose the Right Cable Category

Total Solutions Verification

Analog vs. Digital Transmission

100BASE-SX Fast Ethernet:

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

Understanding the Electrical Performance of Category Cables

Implementing Fast Ethernet

Introduction to Ethernet

Broadband Video over Twisted Pair Cabling. By Paul Kish Director, IBDN Systems & Standards NORDX/CDT

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF

PCM Encoding and Decoding:

Chapter 1: roadmap. Access networks and physical media

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

How To Encode Data From A Signal To A Signal (Wired) To A Bitcode (Wired Or Coaxial)

16-Port and 24-Port 10/100 Switches

Orion2+ SHDSL.bis Solution with 11Mbit/s and 15Mbit/s per Copper Pair

A Feasibility Study of One Twisted Pair Gigabit Ethernet

SECTION 2 TECHNICAL DESCRIPTION OF BPL SYSTEMS

Ethernet Patch Cord Wiring

Page 1 of 7. Computer Networking

Broadband 101: Installation and Testing

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

WHITE PAPER. Enabling 100 Gigabit Ethernet Implementing PCS Lanes

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Gigabit Ethernet. Abstract. 1. Introduction. 2. Benefits of Gigabit Ethernet

Local Area Networks. Guest Instructor Elaine Wong. Elaine_06_I-1

Troubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE WORKING GROUP ON COMMON CONNECTION STANDARDS (CCS)

Frequently Asked Questions

Gigabit Ethernet. Today a number of technologies, such as 10BaseT, Auto-Negotiation

10 Gigabit Ethernet over copper: Unshielded, unprotected?

INTRODUCTION TO MEDIA CONVERSION

Networks. The two main network types are: Peer networks

Controlled Random Access Methods

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

2 Network Media. Copper Core Cable

Application Note: How to Connect a Wired Ethernet Port to the WiPort

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

Upon completing this chapter, you will be able to: Describe the primary types and uses of twisted-pair cables Describe the primary types and uses of

Ethernet/IEEE evolution

C Information Systems for Managers Fall 1999

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

RF Measurements Using a Modular Digitizer

Rapid Prototyping of a Frequency Hopping Ad Hoc Network System

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

Security & Surveillance Cabling Systems

How To Get A Better Signal From A Fiber To A Coax Cable

10 Gigabit Ethernet: Scaling across LAN, MAN, WAN

Next Generation of High Speed. Modems8

Telecommunications, Networks, and Wireless Computing

Local-Area Network -LAN

Tomorrow s IP-Based Access Control System on Today s Network Infrastructure using PCN IP-485 Technology

Evolution from Voiceband to Broadband Internet Access

Media Conversion in Video Security and Surveillance Systems

Transcription:

Gigabit Ethernet Whitepaper 1000ASE- Copyright 1997 Gigabit Ethernet Alliance

ALE OF CONENS ntroduction..................................... 3 he Case for a Copper Gigabit Ethernet Solution......... 4 1000ASE- Overview............................ 5 Standards evelopment Process...................... 6 nteroperability................................ 7 ow oes t Work?............................... 7 he Cabling ssue............................. 7 he esign Approach........................... 9 2

GGA EENE OVE 4-PA 100 OM CAEGO 5 CALNG NOUCON With the dramatic increases in desktop computing power driven by ntranet-based operations and the increasing demands for time-sensitive delivery between networked users, a new generation, high-bandwidth Ethernet LAN is evolving. he rapid adoption of 100Mb/s or Fast Ethernet, due to low cost and compatibility with existing LANs, underscores the popularity of Ethernet technology. With 1000 Mb/s Ethernet following close behind, Ethernet technology is poised as the network solution for the next century. Gigabit Ethernet has been demonstrated to be a viable solution for increased bandwidth requirements for growing networks [reference to GEA white paper]. Early implementation of the technology will be in high-speed backbones and specialized workgroups. As desktop speeds increase and LAN application patterns change, Gigabit Ethernet will begin to migrate to the desktop for general applications. o be most effective, Gigabit Ethernet must be capable of operating over widely-installed cable plants. Worldwide, the most widely deployed cable plant is copper UP (Unshielded wisted Pair) wiring. n fact, four-pair, 100 ohm, Category 5 cabling is the most widely deployed cabling system for high-speed LANs. Ethernet standards are created and maintained by the 802.3 working group of the EEE LAN-MAN Standards Committee. For the last two years, a task force known as 802.3z has been working on fiberoptic and a shielded jumper cable assembly ( short-haul copper ) solutions for Gigabit Ethernet. n the spring of 1997, a new task force was formed to work on a long-haul copper solution based on four pairs of Category 5 cabling wiring. his 802.3ab task force is working to standardize a Gigabit Ethernet link of 100 meters maximum length on four pairs of Category 5 UP cabling. he Gigabit Ethernet standards define an interface (called the GM) to the Ethernet Media Access Control (MAC) layer, management, repeater operations, topology rules, and four physical layer signaling systems: 1000ASE-SX (short wavelength fiber), 1000ASE-LX (long wavelength fiber), 1000ASE-CX (short run copper) and 1000ASE- (100-meter, four-pair Category 5 UP). Figure 1 below shows the relationship of the various members of the Gigabit Ethernet technology family. 3

Media Access Control (MAC) Full uplex / alf uplex Gigabit Media ndependent nterface (GM) MAC P 1000ASE-X 8b/10b Encoder / ecoder 1000ASE- Encoder / ecoder 1000ASE-CX ransceiver 1000ASE-LX ransceiver 1000ASE-SX ransceiver 1000ASE- ransceiver 802.3z 802.3ab Fibre Channel ased echnology Figure 1: he Gigabit Ethernet technology family asic information about Gigabit Ethernet is provided in he Gigabit Ethernet Alliance White Paper. his document focuses specifically on 1000ASE-. E CASE FO A COPPE GGA EENE SOLUON 1000ASE- extends the envelope of Gigabit Ethernet by enabling operation over the extensive installed base of legacy Category 5 cabling systems and, by default, the Category 5 cabling systems currently being installed. he distribution of four-pair Category 5 cabling extends from the work area to the equipment room and between equipment in the equipment room, thus enabling connectivity to switched and shared gigabit services for both high-bandwidth work area computing and server farms. (See Figure 2.) Work Area elecom Closet ransition Point Connector Patch Cord Outlet Cross Connect Patch Cord Channel Figure 2: Category 5 UP cabling systems as per ANS/A/EA-568-A 4

Used in conjunction with Full uplex epeaters, 1000ASE- can provide highly cost-effective shared gigabit service. Full uplex epeaters (Fs), also called buffered distributors, offer the traditional low-cost shared media operation of repeaters, but with support for full-duplex operation. When coupled with 1000ASE-, Fs will offer an easy-to-manage, high-burst rate, shared-media solution capable of supporting both end users and server farms. When used with a server farm, this technology offers the most cost-effective way to aggregate one gigabit of server support. Many potential Gigabit Ethernet technology adopters are already calling for a gigabit UP copper solution because it will allow them to use their existing copper cable plant and because the cost-of-entry for copper solutions has traditionally been lower than fiber-based solutions. 1000ASE- OVEVEW 1000ASE- provides half-duplex (CSMA/C) and full-duplex 1000Mb/s Ethernet service over Category 5links as defined by ANS/A/EA-568-A. opology rules for 1000ASE- are the same as those used for 100ASE-. Category 5 link lengths are limited to 100 meters by the ANS/A/EA-568-A cabling standard. Only one CSMA/C repeater will be allowed in a collision domain 1000ASE- uses the same Auto-Negotiation system employed by 100ASE-X, simplifying the task of gradually integrating it into legacy Ethernet networks. n addition, many of the companies working on 1000ASE- have indicated they will produce dual-speed Ps capable of both 100 Mb/s and 1000 Mb/s operation. his ensures that 1000ASE- devices can fall back to 100ASE-X operation, thus providing a flexible method for upgrading systems. Cable plants conforming to current A/EA-568-A (1995) requirements should support 1000ASE- operation. ndividual links should be tested per ANS/A/EA-S-67- ransmission Performance Specifications for Field esting of wisted Pair Cabling System with the additional test parameters for FEX (ELFEX) loss and return loss that will be included as an addendum to ANS/A/EA-568-A. Cabling test tool manufacturers should have these capabilities added to their products before the 1000ASE- standard is released. Category 5 cabling which does not pass S-67 testing (including addendum parameters) may not have been installed correctly. For example, the amount of untwisting in a pair as a result of termination to connecting hardware cannot exceed 13 mm (0.5 in), or the connecting hardware may not meet current ANS/A/EA-568-A requirements and may need upgrading. All Category 5 links should be tested before using either 1000ASE- or 100ASE-. 5

Some companies plan to have sample quantities of their initial 1000ASE- components (P chips) by mid 1998, with prototype products following shortly thereafter. he first customer shipments of 1000ASE- products should occur in late 1998. Members of the 1000ASE- development team are working to ensure that conformance test suites for 1000ASE- are developed in parallel with the standards effort, so the test suites will be in place when the first products arrive. his will enable testing of components and products before they are released to market. SANAS EVELOPMEN POCESS Ethernet standards are created and maintained by the 802.3 working group of the EEE LAN-MAN Standards Committee. For the last two years, a task force known as 802.3z has been working on fiberoptic and shielded copper jumper solutions for Gigabit Ethernet. n the spring of 1997, a new task force with special expertise in igital Signal Processing (SP) technology was formed to work on a longhaul copper solution based on UP wiring. his 802.3ab task force is working to standardize a Gigabit Ethernet link of 100 meters maximum length on four pairs of Category 5 UP cabling. he 802.3z task force is responsible for 1000ASE-X, which defines MAC changes, a Gigabit Media ndependent nterface, management, and general requirements for 1000 Mb/s operation, as well as a set of physical layer interfaces based on physical layer technology originally developed for Fibre Channel. he 802.3ab task force is developing the 1000ASE- standard, which adds an additional physical layer signaling system to the basic technology defined by 1000ASE-X. 1000ASE-X is now essentially complete and undergoing the formal ballot processes required for EEE 802 approval. he target date for approval of the 1000ASE-X standard is March 1998. 1000ASE- is operating with a longer schedule to accommodate the complex signaling issues involved with running 1000 Mb/s over standard Category 5 wiring. he first draft of what will become the 1000ASE- standard is expected in November 1997; approval of the standard should come in the second half of 1998. (See able 1 below.) able 1: 802.3z and 802.3ab project milestones Milestone 802.3z 802.3ab* Work starts November 1995 November 1995 Project Authorization received March 1996 March 1997 1 st draft January 1997 November 1997 Start Working Group ballot July 1997 March 1998** Start Sponsor ballot November 1997** July 1998** eady to become standard March 1998** November 1998** able notes: * 1000ASE- was initially part of the 802.3z project but formally split off into a separate Working Group in March 1997. ** anticipated 6

nteroperability: Although not a formal part of the standards development process, conformance and interoperability testing are an essential part of bringing a new networking technology to market. he standard defines what to test, but an enabling organization is required to translate standards requirements into test suites and provide a mechanism for applying them uniformly to products. A Gigabit Ethernet Consortium (GEC) was founded in July 1997 to conduct conformance and interoperability testing for all Gigabit Ethernet technologies. he GEC is housed at the University of New ampshire s nteroperability Laboratory (OL), which also houses similar consortia for testing 10ASE-, 100ASE-, AM, Fiber Channel, and oken ing. GEA teams have been working since the summer of 1997 to define test suites for 1000ASE-X technologies. he GEA is encouraging member companies to participate in 1000ASE- test suite development activities with the goal of having initial suites defined by mid- 1998. OW OES WOK? his section provides a brief overview of the technical foundations to 1000ASE-. t covers cabling issues, the proposed technical approach, and a discussion of how the 1000ASE- standard builds upon techniques pioneered in Fast Ethernet and advanced igital Signal Processing. he Cabling ssue Category 5 cabling as defined by ANS/A/EA-568-A is currently the most commonly used data grade cabling in the US. A recent Sage study indicated that more than 72 percent of their sample of network installations reported having Category 5 cabling installed. 1000ASE- is intended to provide a Gigabit Ethernet solution for these legacy networks. Accordingly, the Project Authorization equest (PA) for the 1000ASE- project specifically requires operation on four pair, 100 ohm Category 5 balanced copper cabling as defined by ANS/A/EA-568-A, or its equivalent as built from material specified by SO/EC 11801:1995 that meets the channel performance parameters specified in ANS/A/EA-568-A ANNEX E. (here is currently a proposal to add a Category 5 channel specification to SO/EC 11801 that would provide the same channel performance parameters specified in ANS/A/EA-568-A.) ransmitting a 1000 Mb/s data stream over four pairs of Category 5 twisted pair cables presents several design challenges to the transmission system designer (and standards developer). he challenges are 7

due to signal attenuation, echo, return loss, and crosstalk characteristics of cables, as well as electromagnetic emissions and susceptibility. (See Figure 3 below.) nsertion_loss(f) echo Pair 1 FEX_21 NEX_21NEX_31 FEX_31 Pair 2 NEX_41 FEX_41 Pair 3 Pair 4 Figure 3: he cabling challenge. Attenuation is the signal loss of the cabling from the transmitter to the receiver. Attenuation increases with frequency, so designers are challenged to use the lowest possible frequency range that is consistent with the required data rate. Echo is a by-product of dual-duplex operation, where both the transmit and receive signal occupy the same wire pair. he residual transmit signal due to the trans-hybrid loss and the cabling return loss combine to produce an unwanted signal referred to here as echo. eturn loss is a measure of the amount of power reflected due to cabling impedance mismatches. Crosstalk is unwanted signals coupled between adjacent wire pairs. Since 1000ASE- will use all four wire pairs, each pair is affected by crosstalk from the adjacent three pairs. Crosstalk is characterized in reference to the transmitter. Near-end crosstalk (NEX) is crosstalk that appears at the output of a wire pair at the transmitter end of the cable and far-end crosstalk (FEX) is crosstalk that appears at the output of a wire pair at the far end of the cable from the transmitter. Equal level far-end crosstalk (ELFEX) is FEX with the cable attenuation removed to provide equal-level comparisons, i.e., crosstalk and receive signals voltages are compared at the end of 8

the cabling opposite the transmitter. esigners must incorporate technology to keep crosstalk from interfering with symbol recovery operations in the receiver. Additional specifications for FEX (ELFEX) loss and return loss, which are not currently specified by A/EA-568-A ANNEX E, have been developed to characterize the vast majority of the installed base of Category 5 cabling built to ANS/A/EA-568-A and/or SO/EC 11801 clauses 6, 8 & 9. A currently proposed addendum to ANS/ANS/A/EA-568-A will include the additional transmission performance specifications and field test parameters for FEX (ELFEX) loss and return loss. A verification of the installed cabling performance per the field test specification of ANS/A/EA-S- 67- ransmission Performance Specifications for Field esting of wisted Pair Cabling System with the additional test parameters for FEX (ELFEX) loss and return loss (to be released as an addendum to ANS/A/EA-568-A) will be recommended. A transmission system operating over unshielded cable must be capable of withstanding radiated energy from other sources, including AM, C, short wave radio, and other external transmitters. Standards such as EN50082-1 and EC 1000-4-3 (EC 801-3 Level 2) also specify a required tolerance to a 3 V/m continuous wave source above 27 Mz. A further design objective is to maximize the tolerance to background and impulse noise. mpulse noise can be generated by power line transients, electrical fast transients, electro-static discharge (ES), and other sources. Although there is no precise specification from existing standards concerning the minimum tolerance to impulse noise that could be acceptable for 1000ASE-, a general goal is to strive for as much tolerance as possible. he esign Approach he characteristics of Category 5 cabling and the regulatory constraints identified above create a significant challenge in defining the 1000 Mb/s physical layer. Fortunately, digital communications techniques developed in recent years can be used to design robust transceivers that are capable of achieving reliable operations in a Category 5 cabling environment. 1000ASE- takes advantage of several of these techniques to transform the desired bit rate into an acceptable baud rate (signaling events per second) for operation over 4-pair Category 5 cabling. Use existing 4-pair Category 5 cable. o ensure proper operation at full link lengths, the cable must conform to the requirements of ANS/A/EA-568-A (1995). Use all four pairs in the cable to keep symbol rate at or below 125 Mbaud. 9

Use PAM-5 coding to increase the amount of information sent with each symbol. Use 4 8-state rellis Forward Error Correction coding to offset the impact of noise and crosstalk. Use pulse shaping techniques to condition the transmitted spectrum. Use state-of-the-art SP signal equalization techniques to manage the problems of noise, echo and crosstalk interferences, and to ensure a bit error rate of 10-10. echnical descriptions of these techniques are described in the remainder of this subsection. he block diagram of a 1000ASE- transceiver (shown in Figure 4) shows the relationships among the various components. x Magnetics Auto Negotiation/ GM PCS ransmit Pulse Shaping Synch AC A/ esistive ybrid uning Control PLL NC NC NC NC elay Adj. Σ FFE PCS eceive Viterbi ecoder/ FE Figure 4: lock diagram of the 1000ASE- transceiver. ual-duplex transmission consists of transmitting and receiving data simultaneously in both directions (full-duplex transmission) on each of the four wire pairs, minimizing the symbol rate (and thus, the occupied signal bandwidth) on each wire pair by one half, as compared to unidirectional transmission and reception. ybrid circuits are used to enable bi-directional transmission over single wire pairs by filtering out the transmit signal at the receiver. (See Figure 5 below.) 10

ybrid networks with good trans-hybrid loss minimize the amount of transmitter signal that is coupled into the receiver but still cannot remove all of the transmit signal. he residual transmit signal from the hybrid and the return loss of the cable require that cancellers are added to each wire pair to remove the transmit echo signal. Figure 5: ual-duplex transmission uses hybrids to separate transmit and receive signals on each wire pair. 5-level PAM provides better bandwidth utilization than binary signaling, where each transmitted symbol represents just one bit (0 or 1.). n 5-level PAM, each transmitted symbol represents one of five different levels (-2, -1, 0, + 1, +2). Since each symbol can represent two bits of information (four levels used to represent two bits, plus an extra fifth level used in the Forward Error Correction coding), the symbol rate, and therefore also the signal bandwidth, are reduced by a factor of two. he costs of multilevel signaling include the need for a higher signal-to-noise ratio for a given error rate, the use of multi-bit /A and A/ converters and the need for better receiver equalization. 11

0 1 FEC bit 0 0 1 1 inary signaling 1000ASE- 5-level PAM Figure 6: inary vs 5-level PAM coding Forward Error Correction (FEC) provides a second level of coding that helps to recover the transmitted symbols in the presence of high noise and crosstalk. he 4-imensional 8-State rellis Forward Error Correction encoding facilitates recovering the transmitted symbols in the presence of high noise and crosstalk. his technique improves the signal-to-noise ratio at the slicer -the decision element in the Analog-to-igital (A/) converter in the receiver. Pulse shaping matches the spectral characteristics of the transmitted signals to those of the channel in order to maximize the signal-tonoise ratio. his is achieved with a combination of analog and digital filtering elements used at the transmitter, at the receiver, or both. Pulse shaping is used to minimize the transmitted signal energy at frequencies where distortion and disturbances are significant, to reduce both low- and high frequency signal components, and to reject highfrequency external noise components. he pulse shaping techniques used by 1000ASE- transmitters improve the potential for meeting class emission specifications. hrough pulse shaping the 1000ASE- transmitted signal spectrum will be essentially identical to the 100ASE-X spectrum. aseband Pulse Shaping 125 Mz GM Symbol Encoder 125 Mz 125 Mz, 5 levels Figure 7: Pulse shaping produces a 1000ASE- signal spectrum that matches the 100ASE-X spectrum. 12

Signal equalization is used to compensate for signal distortion introduced by the communication channel. Linear digital equalization is usually provided by a finite impulse response (F) filter. owever, linear equalizers color the noise in the receiver. his is especially true as frequency increases and noise coupling becomes worse. he higher the bandwidth of the coding scheme, the more aggressive the equalization and, hence, the greater the high frequency noise boost. Nonlinear equalization is usually provided by a decision-feedback equalizer (FE) and often provides better signal equalization than linear equalization, especially when the transmission medium introduces strong signal attenuation within specific frequency regions. Unlike a linear equalizer, a FE does not modify the noise. herefore, using a FE does not enhance high-frequency noise. owever, using a FE to equalize the channel is prone to error propagation, where a single error causes mis-equalization and further errors. One solution to this problem is to use multiple FEs. Scrambling is used to randomize the sequence of transmitted symbols and avoid the presence of spectral lines in the transmitted signal spectrum. Scrambling also creates essentially uncorrelated data symbols, which improves operation of the adaptive receiver functions. Many of the principles and techniques proposed for the 1000ASE- design approach have already been employed in three 100ASE- (Fast Ethernet) copper physical layer solutions: 100ASE-X, which runs on 2 pairs of Category 5 cabling with a 125 Mbaud symbol rate and binary encoding, 100ASE-4, which runs on 4 pairs of Category 3 or better cabling with a 25 Mbaud symbol rate and ternary encoding, and 100ASE-2, which runs on 2 pairs of Category 3 or better cabling with a 25 Mbaud symbol rate with quinary encoding and SP processing to handle the potential problems of alien signals in adjacent wire pairs (alien crosstalk.) 100ASE-X demonstrates that it is possible to send a symbol stream over Category 5 cable at 125 Mbaud. 100ASE-4 demonstrates techniques for sending multi-level coded symbols over four pairs. 100ASE-2 demonstrates the use of digital signal processing (SP), five-level coding, and simultaneous two-way data streams while dealing with alien signals in adjacent pairs. Participants in the 1000ASE- development effort are making aggressive use of simulation tools to evaluate alternative technical approaches, following on earlier simulation efforts used to develop 100ASE-2. While exploring alternative approaches to line coding and forward error correction techniques, the engineers simulated their own proposals as well as those of the other participants. hese simulations have been done both in Matlab and in C. he C simulations 13

have established the necessary confidence that the it Error ate (E) requirements can be met in the presence of ECO, NEX, and FEX. he simulations also have established that significant levels of external noise (>80mv p-p) can be tolerated. he large amounts of simulation work that have been done significantly increase the conviction that reliable Gigabit Ethernet over copper is both feasible and practical. 14

Gigabit Ethernet Alliance 20111 Stevens Creek oulevard, Suite 280 Cupertino, California 95014 Phone: (408) 241-8904 Fax: (408) 241-8918 http://www.gigabit-ethernet.org