Worldwide Experience with S-ICD: Early results from the EFFORTLESS Registry



Similar documents
Pacemaker Counter and Histogram Operation and Interpretation. Percentage of total count. Figure 2. Detailed ALTRUA Paced and Sensed Event Counters

Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken. Föråldrad version. Använd ej. Versão obsoleta. Não utilize.

Atrial Fibrillation and Cardiac Device Therapy RAKESH LATCHAMSETTY, MD DIVISION OF ELECTROPHYSIOLOGY UNIVERSITY OF MICHIGAN HOSPITAL ANN ARBOR, MI

2015 Subcutaneous Implantable Defibrillator (the S-ICD TM System) Coding Guide Rhythm Management

Basics of Pacing. Ruth Hickling, RN-BSN Tasha Conley, RN-BSN

MRI Case Study MRI Cervical Spine

Introduction. Planned surgical procedures

Automatic External Defibrillators

EMBLEM S-ICD Subcutaneous Implantable Cardioverter Defibrillator

What Are Arrhythmias?

Medical management of CHF: A New Class of Medication. Al Timothy, M.D. Cardiovascular Institute of the South

CCAD Training Manual. Cardiac Rhythm Management (CRM)

Christopher M. Wright, MD, MBA Pioneer Cardiovascular Consultants Tempe, Arizona

Remote Monitoring of Cardiac Implantable Electrical Devices (CIEDs)

IMAGEREADY MR CONDITIONAL DEFIBRILLATION SYSTEM

DEVICE RECALLS: The Era of Regulation and Outcome Metrics: Optimizing Benefits and Managing Risks

ICD leads under advisory What should be done?


MADIT-II CLINICAL SUMMARY

ATRIAL FIBRILLATION (RATE VS RHYTHM CONTROL)

on behalf of the AUGMENT-HF Investigators

REMOTE CARE ALERT MANAGEMENT REFERENCE GUIDE Managing Merlin.net

Michael Hartman, CRNA, DNP, MSN, BSN, BA

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

SW012. Installation software for the Right Ventricular Lead Integrity Alert feature. Reference Manual

The science of medicine. The compassion to heal.

MRI SureScan Pacing System

COVERAGE GUIDANCE: ABLATION FOR ATRIAL FIBRILLATION

Atrial Fibrillation Catheter Ablation versus Surgical Ablation Treatment: FAST A Two-Center Randomized Clinical Trial

What Can I Do about Atrial Fibrillation (AF)?

Adding IV Amiodarone to the EMS Algorithm for Cardiac Arrest Due to VF/Pulseless VT

LATITUDE NXT 4.0 Quick Reference Guide

Diagnosis Code Crosswalk : ICD-9-CM to ICD-10-CM Cardiac Rhythm and Heart Failure Diagnoses

INFORMED CONSENT FOR SLEEVE GASTRECTOMY

Rome, Italy December 4-7, 2012 Rome Cavalieri TIMETABLE

Telecardiology Technical Innovations and Challegenes in Clinical Practice

Introduction to Electrophysiology. Wm. W. Barrington, MD, FACC University of Pittsburgh Medical Center

Tachyarrhythmias (fast heart rhythms)

Crash Cart Drugs Drugs used in CPR. Dr. Layla Borham Professor of Clinical Pharmacology Umm Al Qura University

Addendum to the Guideline on antiarrhythmics on atrial fibrillation and atrial flutter

Guidelines for deactivating implantable cardioverter defibrillators (ICDs) in people nearing the end of their life

IMPLANTABLE CARDIOVERTER DEFIBRILLATORS (ICDs)

RATE VERSUS RHYTHM CONTROL OF ATRIAL FIBRILLATION: SPECIAL CONSIDERATION IN ELDERLY. Charles Jazra

ACLS Provider Manual Comparison Sheet Based on 2010 AHA Guidelines for CPR and ECC. BLS Changes

Dr. Sven Bode 24. Treffpunkt Medizintechnik 1. Juli Telemetrische Herzüberwachung Eine Dekade BIOTRONIK Home Monitoring

CLINICIAN MANUAL. LATITUDE Patient Management System

National CRM Database Future Directions. Francis Murgatroyd King s College Hospital, London

2014: nowadays the one shot technologies and the injectable monitor allow a wide and complete AF patient management. Why shouldn t we use them?

Chronic Vagus Nerve Stimulation: A New Treatment Modality for Congestive Heart Failure

STANDARDS FOR IMPLANTATION AND FOLLOW-UP OF CARDIAC RHYTHM MANAGEMENT DEVICES IN ADULTS January 2013

Implantable Cardioverter Defibrillator Therapy

Management of Pacing Wires After Cardiac Surgery

CRM Product Performance Report 2014 Q4 Edition

CareLink Network. Clinic Setup Guide WORKFLOWS. FAQs

INSERTABLE CARDIAC MONITORING SYSTEM. UNLOCK the ANSWER. Your heart and long-term monitoring

DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services

Adverse Events in Clinical Trials: Definitions and Documentation

Medtronic Cardiac Rhythm and Heart Failure ICD-10 Coding for Physicians

CLINICIAN MANUAL. LATITUDE NXT Patient Management System

Novartis Gilenya FDO Program Clinical Protocol and Highlights from Prescribing Information (PI)

Atrial Fibrillation An update on diagnosis and management

Billing and Coding Guide

BCCA Protocol Summary for Palliative Therapy for Metastatic Breast Cancer using Trastuzumab Emtansine (KADCYLA)

VIVA QUAD XT CRT-D DTBA1QQ

Assessment, diagnosis and specialist referral of adults (>16 years) with an episode of transient loss of consciousness (TLoC) or a blackout.

Treatments to Restore Normal Rhythm

Implantable Cardioverter Defibrillator Treatment: Benefits and Pitfalls in the Currently Indicated Population. Carel Jan Willem Borleffs

Recurrent AF: Choosing the Right Medication.

Establishing a Remote Monitoring Program. Martha Ferrara, FNP

WATCHMAN Left Atrial Appendage Closure Device

FREEDOM INGUINAL Hernia Repair System TECHNIQUE GUIDE

Steven J. Yakubov, MD FACC For the CoreValve US Clinical Investigators

CLINICIAN MANUAL. LATITUDE TM Patient Management System

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

PACEMAKERS AND ANTITACHYCARDIA DEVICES WILLIAM BATSFORD, M.D.

BRYAN. Cervical Disc System. Patient Information

ANNE ARUNDEL MEDICAL CENTER CRITICAL CARE MEDICATION MANUAL DEPARTMENT OF NURSING AND PHARMACY. Guidelines for Use of Intravenous Isoproterenol

Potential Causes of Sudden Cardiac Arrest in Children

UCSF Anesthesia Resident Pearls: Cardiac Implantable Electronic Devices: Pacemakers and ICDs Table of Contents

Hemodialysis catheter infection

Ngaire has Palpitations

James F. Kravec, M.D., F.A.C.P

Electrophysiology Heart Study - EPS -

PHENYLEPHRINE HYDROCHLORIDE INJECTION USP

Il loop recorder esterno. Roberto Maggi

Leveraging Social Networks to Conduct Observational Research: A Paradigm Shift in Methodology. Presented by: Elisa Cascade, MediGuard/Quintiles

Electrodiagnostic Testing

Clinical Study Synopsis

Transcription:

Worldwide Experience with S-ICD: Early results from the EFFORTLESS Registry Results published in European Heart Journal (March 2014) Pier D. Lambiase, Craig Barr, Dominic A.M.J. Theuns, Reinoud Knops, Petr Neuzil, Jens Brock Johansen, Susanne Pedersen, Stefan Kääb, Francis Murgatroyd, Helen L. Reeve, Nathan Carter & Lucas Boersma, on behalf of the EFFORTLESS Investigators. CRM 235403 AA MAR14 1 PD Lambiase, C Barr, DAMJ Theuns, et. al., European Heart 2014 Boston Scientific Corporation or its affiliates. All rights reserved. CRM Journal 235403 AA Mar APR14 2014

Background International, standard of care registry to document short, mid and long-term operational and clinical outcome data on the S-ICD system 1000 patients followed for 5 years post implant Includes both retrospective and prospective patients implanted since CE mark in 2009 Centers to be included from all current commercial countries 2 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Eligibility Inclusion Criteria 18yrs at time of consent* Eligible for implantation of an S-ICD System per local clinical guidelines or currently implanted with a S-ICD System Exclusion Criteria Participation in any other investigational study that may interfere with interpretation of the study results Class I indications for permanent pacing Pace-terminable VT Previously implanted unipolar pacemakers *A subset of countries implemented a protocol that allows patients under the age of 18 3 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Interim Results Published in European Heart Journal in early 2014 472 patients enrolled between Feb 2011 and April 2013 at 29 sites from seven different countries 232 included in QOL sub-study (not yet reported) 4 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Patient Enrollment 5 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Baseline Characteristics Demographic Value Category Age (years) 49 ± 18 (range 9 88) Male, % 72% EFFORTLESS Registry n= 472 patients Represents a younger population than typical TV-ICD studies and registries NCDR ICD Registry n=486,025 patients Primary and Secondary Prevention mix is typical of the current EU TV-ICD implants 6 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Baseline Characteristics Broad Spectrum of Clinical Indications * * * Significant proportions of historically more difficult to treat indications (non-ischemic, congenital and inherited channelopathies) representing >50% of total population 7 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Baseline Characteristics Attribute Statistic/Category N % Congestive Heart Failure 128 29 Comorbidities Class I Class II Class III 24 52 34 History Hypertension 106 24 Diabetes 53 12 Atrial Fibrillation 76 17 Kidney disease 39 9 Cardiac Surgical History Concomitant pacemaker Previous TV-ICD 13 67 LVEF, % 42 ± 19 QRS interval, ms 107 ± 28 3 15 TV-ICD Explant patients were also studied in the registry Co-morbidities present typical of the current TV-ICD patient population 8 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Implant Procedure and Follow-up Attribute Statistic/Category N % Implant Procedure Follow-up data Patients implanted 456 95 General anesthesia 63 Medical imaging 13 Skin-to-skin time, min* 69 ± 27 Min max, days 13-1342 Median, days 498 Mean, days 558 Patients with 1-yr FU 294 61 Patients with 2-yr FU 143 30 Patients with 3-yr FU 52 10 Longest patient follow-up is >3.5 years * No distinction was made between procedure times that were solely for implant of the S-ICD versus those that included additional procedures 9 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Patient Status Attribute Statistic/Category N % Mortality Explants Total Deaths 9 2 Peri-procedural deaths 0 0 Pump/Renal Failure 7 1.4 Lack of Documentation 1 0.2 Arrhythmic* 1 0.2 Total 17 3.7 Infection-related 8 1.8 Inappropriate sensing & shocks** 2 0.4 Elective TV-ICD update (recurrent VT) 2 0.4 Failure to convert 2 0.4 Comfort 1 0.2 Erosion 1 0.2 Heart Transplant 1 0.2 * Patient (not a candidate for TV-ICD) with Loeffler s syndrome required steroid therapy which may have led to elevated DFT None of the deaths (n = 9) have been reported to be related to the S-ICD system or implant procedure 10 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Complication-Free Rate 94% Complication Free at 360 days 97% Peri-procedural complication free rate 94% 1yr complication free rate 11 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Infections All Suspected & Confirmed Infections 18 patients (3.9%) Confirmed Infection* 11 patients (2.4%) Explants 10 patients (2.2%) No systemic blood infections or endocarditis No reports of infection in patients with previous TV-ICDs (explanted due to infection) Permanent Explants 8 patients (1.8%) S-ICD Re-Implantation 2 patients (0.4%) * 2 infections were due to concomitant TV leads 12 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Implant Conversion Testing Successful conversion efficacy at implant defined as at least one successful conversion of an induced ventricular arrhythmia at 80J Patient data N % Complete data for evaluation 393 Successful Conversion 392 99.7 Repositioning required for initial failure 7 1.8 Successful at 65J 373 95 Implant Conversion Efficacy was 99.7% 13 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Spontaneous Conversion Efficacy VT/VF episodes (Pts) Classification N (Pts) Storm 40 (4) Sustained VT/VF 91 (33) Discrete 51 (29) Classification Total (Pts) TERMINATION (%) Discrete VT/VF Episodes Storm Episodes 1 st S-ICD Shock Conversion) Conversion by Shocks 1-5 Conversion prior to end of episode 51 (29) 45 (88%) 49 (96%) 51 (100%) 40 (4) (6 Storm Events) 5 (83%)* * Patient with Loeffler s syndrome requiring steroid therapy which may have lead to elevated DFT All discrete episodes were successfully converted with 80J shock or spontaneously terminated (100% clinical efficacy) 14 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Inappropriate Therapy: Incidence 32 patients received 73 inappropriate shocks on average FU of 18 months, resulting in an inappropriate therapy rate of 7% at 360 days. IAS & Programming Reasons for IAS P = 0.09 82% of patients were programmed to dual-zone which reduced the inappropriate therapy rate to 6.4% Only one inappropriate therapy has been recorded for AF/SVT within the programmed conditional zone in all S-ICD System clinical evaluations 72% of patients were inappropriate therapy-free after initial interventions (reprogramming, exercise tests, medication changes) 15 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Time to therapy Induced Spontaneous 15.1 ± 3.7 sec with range of 7 to 37 seconds TTT generally shorter with induction due to only 65 J charge and removal of one counter to allow faster therapy delivery 17.5 ± 4.4 sec with range of 6 to 29 seconds Therapy withheld in 13% of patients and 46% of stored episodes due to longer time to therapy No clinical events (i.e. syncope) were reported for any of the spontaneous episodes 16 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

Conclusions The largest cohort of real-world S-ICD System data demonstrates comparable performance to TV-ICDs. 17 2014 Boston Scientific Corporation or its affiliates. All rights reserved.

S-ICD System from Boston Scientific CRM Indications for Use The S-ICD System is intended to provide defibrillation therapy for the treatment of life-threatening ventricular tachyarrhythmias in patients who do not have symptomatic bradycardia, incessant ventricular tachycardia, or spontaneous, frequently recurring ventricular tachycardia that is reliably terminated with anti-tachycardia pacing. Contraindications Unipolar pacemakers are contraindicated for use with the S-ICD System. Warnings and Cautions The S-ICD System contains sterile products for single use only. Do not resterilize. Handle the components of the SICD System with care at all times and maintain proper sterile technique. All Cameron Health implantable components are designed for use with the Cameron Health S-ICD System only. Connection of any S-ICD System components to any other ICD system will result in failure to deliver lifesaving defibrillation therapy. General External defibrillation equipment should be available for immediate use during the implantation procedure and follow-up. Placing a magnet over the SQ-RX Pulse Generator suspends arrhythmia detection and therapy response. Removing the magnet resumes arrhythmia detection and therapy response. Battery depletion will eventually cause the SQ-RX Pulse Generator to stop functioning. Defibrillation and excessive numbers of charging cycles shorten the battery longevity. The S-ICD System has not been evaluated for pediatric use. The S-ICD System does not provide long-term bradycardia pacing, Cardiac Resynchronization Therapy (CRT) or Anti-Tachycardia Pacing (ATP). Potential Adverse Events related to implantation of the S-ICD System may include, but are not limited to, the following: Acceleration/induction of atrial or ventricular arrhythmia; Adverse reaction to induction testing; Allergic/adverse reaction to system or medication; Bleeding; Conductor fracture; Cyst formation; Death; Delayed therapy delivery; Discomfort or prolonged healing of incision; Electrode deformation and/or breakage; Electrode insulation failure; Erosion/extrusion; Failure to deliver therapy; Fever; Hematoma; Hemothorax; Improper electrode connection to the device; Inability to communicate with the device; Inability to defibrillate or pace; Inappropriate post-shock pacing; Inappropriate shock delivery; Infection; Keloid formation; Migration or dislodgement; Muscle stimulation; Nerve damage; Pneumothorax; Post-shock/post-pace discomfort; Premature battery depletion; Random component failures; Stroke; Subcutaneous emphysema; Surgical revision or replacement of the system; Syncope; Tissue redness, irritation, numbness or necrosis. S-ICD, SQ-RX and Q-TRAK are registered trademarks of Cameron Health, Inc. Q-TECH, Q-GUIDE and INSIGHT are trademarks of Cameron Health, Inc. Refer to the product labeling for specific indications, contraindications, warnings/precautions and adverse events. Rx only. (Rev. C Information for the use in countries with applicable Health Authority product registrations 18 2014 Boston Scientific Corporation or its affiliates. All rights reserved.