Masimo Patient Safetynet HL7 Interface Specifications



Similar documents
JiveX Enterprise PACS Solutions. JiveX HL7 Gateway Conformance Statement - HL7. Version: As of

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

HL7 Conformance Statement

RelayClinical Service Feature Guide RelayClinical Notify

HL7 Interconnection Guide v1.1

D* SEE SAP DIR DIGITAL SIGNATURE LOG FOR APPROVER NAME AND DATE OF APPROVAL

HL7 Conformance Statement

HL7 Conformance Statement RadCentre. Release

Patient SafetyNet System

Generic EHR HL7 Interface Specification Abraxas v. 4

HL7 Interface Specification Merge LabAccess v. 3.6

HL7 Interface Specifications

Philips Innovation Campus Bangalore India. Issued by:

Early Evaluation Center

Connect care for early intervention

Optimizing Masimo SET SpO2 Alarm Settings on Select GE Monitors

IHE Patient Care Device Technical Framework Supplement. Medical Equipment Management Device Management Communication (MEMDMC) Trial Implementation

X Series Extensive Capabilities

HL7 Interface Specification Merge Eye Station v. 11.3

Connecting Cardiac Device Data and the EHR

Connecting Cardiac Device Data and the EHR

MOSAIQ External Systems Interfaces (ESI) Product Offerings

HL7 Onboarding Guide for. May 2015 v3

20/20 Integration Guide

HL7 Fundamentals. Presented by: Dana McDonough, Carolina Velasquez, & Bing Chen. August 2014

AIDA compact NEO HL7 Interface Description

Meaningful Use Business Process Mapping Questionnaire. Meaningful Use Business Process Mapping Questionnaire. Contact Information

80BPM 36.5 C 35/ / 80. Panorama CENTRAL MONITORING SYSTEM. efficient flexible versatile (18) (94) Adult A SMITH, ERICA (92) 5RPM.

A method for handling multi-institutional HL7 data on Hadoop in the cloud

Michigan Pulse Oximetry Screening for Critical Congenital Heart Disease

Oracle SOA Suite 11g Oracle SOA Suite 11g HL7 Inbound Example Functional ACK Addendum

Concept. Monitoring Unit. Patient Box. Defibrillator/Pacer Unit.

ELR Clarification Document for EHR Technology Certification

Design of Internet Protocols:

IHS Pharmacy-Automated Dispensing Interface System (BOP)

Message Specifications Guide

Medical Records Training Manual for EMR

Policy Name: Patient Monitoring via the Patient SafetyNet (PSN) Monitoring System

Project Initiation Report HealthInsight HIE

Interfacing Boot Camp

EMR Technology Checklist

MHS EMR Program. EMR HIE Integration Toolkit

Masimo Adaptive Threshold Alarm : Intelligent and Personalised Notification to Reduce Nuisance Alarms

DIAGNOSTIC TEXT AND OTHER TRANSCRIBED REPORTS MESSAGE SPECIFICATION

ImagePilot. HL7 Conformance Statement. Manufacturer: 1 Sakura-machi, Hino-shi Tokyo , Japan

RamSoft PACS 3.0 HL7 Conformance Statement

HL7 Format and Electronic Sharing

Overview. LATITUDE Patient Management. EMR Integration Testing Scenarios

HL7 Customization Guide

GE Healthcare. B40 Patient Monitor Connecting intelligence and care.

Registration Hold Capabilities in EMR-Link

HL7 Interface Specification. HL7 Interface 1.2

IDAHO STATE UNIVERSITY POLICIES AND PROCEDURES (ISUPP) HIPAA Privacy - Minimum Necessary Standard for Use and Disclosure of PHI 10190

Ruchika D. Husa, MD, MS Assistant t Professor of Medicine in the Division of Cardiology The Ohio State University Wexner Medical Center

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Advanced Monitoring Parameters 2015 Quick Guide to Hospital Coding, Coverage and Payment

Heath Shield Heath Care Management System

Sue Carol Verrillo, RN, MSN, CRRN The Johns Hopkins Hospital November 14, 2014

Sunrise Acute Care (SAC) Module 1 New Provider Basic Course

Text Integration Utilities (TIU) Generic HL7 Interface Handbook

Connex Device Integration Suite (CDIS) Network Connectivity Engine (NCE) software -

DICOM Conformance Statement FORUM

IHE Standards: Integrating Surgery and Anesthesia to the Enterprise

Deployment Planner. inexx Novo Grid Practice Agent HW Requirements.pdf

Policy Based Encryption E. Administrator Guide

Policy Based Encryption E. Administrator Guide

ZAN HL7 Interface. Installation and Specifications Manual Part Number : *************ENG Version / Revision : A

Launch and View External Exams from Epic

Designed with you in mind.

CareAware Capacity Management - Patient Flow Patient List Gadget

HL7 ADT, ORM and ORU & DICOM tag agreement with RIS, PACS and VNA

AHIC / NeHC Use Case. Common methods of Device Connectivity (CmDC)

Oracle SOA Suite 11g Oracle SOA Suite 11g HL7 Inbound Example

A new innovation to protect, share, and distribute healthcare data

DLP Quick Start

March 31, Etiometry, Inc. Richard Galgon Independent Consulting Associate Quintiles 5846 Cobblestone Lane Waunakee, Wisconsin 53597

Insight Student for Chromebooks - Auto Configuration

SECURE COMMUNICATIONS PLAN Updated August 25, 2011

Event Notification Service Overview for the Florida HIE

VA SAN DIEGO HEALTHCARE SYSTEM MEMORANDUM SAN DIEGO, CA

empowersystemstm empowerhis Advanced Core Hospital Information System Technology Comprehensive Solutions for Facilities of Any Size

Volume 2 Compliance Process

OMNI TOUCH SCREEN PATIENT MONITOR

Solution Title: Predicting Care Using Informatics/MEWS (Modified Early Warning System)

,11 DSA Cable, transducer and VS3, VS4 electrode, patient connector

it s about connectivity

Welch Allyn Connex Vital Signs Monitor 6000 Series and Accessory Cable Management Stand. Advanced accessory management that stands on its own.

Transactions Module. 70 Royal Little Drive. Providence, RI Copyright Optum. All rights reserved. Updated: 3/1/14

Ensuring Patient Safety in Your Connected Hospital

IHE IT Infrastructure Technical Framework. Volume 2b (ITI TF-2b) Transactions Part B Sections

IHE Radiology Technical Framework Volume 3 (IHE RAD TF-3)

HIE Ready 2.0 SPECIFICATIONS MATRIX. Product Name: Version Number: Preferred Message and Trigger

Outlook Synchronisation guide

EMR AND BIG DATA. September 2014 EMR

Health Home Performance Enhancement through Novel Reuse of Syndromic Surveillance Data

Transcription:

TECHNICAL BULLETIN Masimo Patient Safetynet HL7 Interface Specifications Version 1.0 August 2013 CAUTION: Federal law restricts this device to sale by or on the order of a physician. For professional use. See Patient SafetyNet instructions for use for full prescribing information, including indications, contraindications, warnings, precautions, and adverse events. 2013 by Masimo Corporation. SafetyNet is a trademark of Masimo Corporation. All rights reserved.

PATIENT SAFETYNET HL7 INTERFACE SPECIFICATIONS TABLE OF CONTENTS INTRODUCTION...3 CONNECTIVITY...3 SUPPORTED INTERFACE PROFILES...3 ADT ADMIT, DISCHARGE AND TRANSFER (INBOUND)...3 Supported ADT messages...4 Device Observation Reporting (Outbound)...4 Sample Outbound Message...5 Message Acknowledgement (Outbound)...5 Time Synchronisation (Inbound)...5 MESSAGE FORMATTING...6 Character Encodings...6 INTERFACE DEPLOYMENT...6 Interface Deployment Process...6 Interface Testing...7 Inbound/Outbound Message Configuration...7 Initial Patient Index Synchronisation...8 DATA PRIVACY AND PHI...8 PATIENT SAFETYNET ADMISSION...9 INTERFACE MANAGEMENT AND TECHNICAL SUPPORT...11

WHITEPAPER INTRODUCTION Masimo Patient SafetyNet * is a supplemental remote monitoring and clinician notification system. It provides a secondary display of physiologic monitoring devices, especially Masimo SET and rainbow pulse oximetry and acoustic respiration rate monitors. SafetyNet enables clinicians to view and monitor patient physiological conditions when used in hospitals or hospital-type environments. The user should refer to the Operator Manual for the Patient SafetyNet System for complete instructions for use, warnings, and precautions. The Masimo Adaptive Connectivity Engine (ACE) component of Patient SafetyNet interfaces to patient demographics providers, electronic medical records systems using HL7 version 2.x messages, receiving inbound Admit, Discharge, and Transfer (ADT) information, and reporting patient vital signs. Patient SafetyNet (instance #n) Sensor Monitor #1 ADT Server Patient Monitor #n Network **Patient SafetyNet (instance #1) *ACE HL7 2.x Hospital IT Network EMR Server Clinician Notification Device Network Notification Gateway *ACE: Adaptive Connectivity Engine **SafetyNet: Monitor up to 80 bed side monitors CONNECTIVITY Patient SafetyNet is field-configured by Masimo to interface with new systems that can generate and receive HL7 version 2.x messages. Patient SafetyNet s HL7 interface can be configured to comply with the IHE Patient Care Device Technical Framework, 1 including the Pulse Oximetry Integration supplement. SUPPORTED INTERFACE PROFILES ADT Admit, Discharge, and Transfer (Inbound) The Patient SafetyNet HL7 Interface supports communication of patient ADT, using HL7 messaging on a configured socket. The HL7 ADT message allows Patient SafetyNet to receive patient ADT information and make the information available to clinicians in order to admit a patient to the Patient SafetyNet system. The Patient SafetyNet admission process is an internal process to associate a connected instrument to a patient. Deploying Patient SafetyNet HL7 ADT interface will facilitate the following: > > Facilitate Patient Admission: Clinicians can use the patient information provided by the interface to admit patient to Patient SafetyNet system (more detail in section 7 Patient SafetyNet Admission). > > Facilitate Vital Signs Reporting: Using patient information provided by the interface will facilitate vital signs reporting (outbound messages) to the Electronic Medical Record (EMR), Patient SafetyNet system will use patient information (e.g. Master Record Number) to report patient vital signs to the EMR. * The use of the trademarks PATIENT SAFETYNET and PSN is under license from University Health System Consortium.

PATIENT SAFETYNET HL7 INTERFACE SPECIFICATIONS Supported ADT messages The Patient SafetyNet HL7 Interface supports the following HL7 version 2.x ADT messages: Message Code A01 A02 A03 A04 A06 A07 A08 A11 A12 A13 A17 A18 A23 A34 A35 A36 A40 A46 A47 Description Admit/Visit Notification Transfer a Patient Discharge/End Visit Register a Patient Change an Outpatient to an Inpatient Change an Inpatient to an Outpatient Update Patient Information Cancel Admit/Visit Notification Cancel Transfer Cancel Discharge/End Visit Swap Patients Merge Patient Information Delete a Patient Record Merge Patient Information Patient ID Only Merge Patient Information Account Number Only Merge Patient Information Patient ID and Account Number Merge Patient Patient Identifier List Change Patient ID Change Patient Identifier List Other message types do not affect Patient SafetyNet s patient roster, and are processed by sending an acknowledgement only. Device Observation Reporting (Outbound) The Patient SafetyNet HL7 interface supports and acts as an IHE PCD Device Observation Reporter (DOR) where the Patient SafetyNet HL7 interface periodically sends patients' vital signs to systems, which act as Device Observation Consumers (DOC) (e.g., an EMR). The IHE support message for vital signs is the PCD-01 message. Patient SafetyNet sends parameters monitored by Masimo Instruments connected to the SafetyNet system. Below are the outbound vital signs parameters, unit of measure, and HL7 tags. Identifier (OBX-3) Vital Sign Units (OBX-6) Unit of Measure SpO2 Oxygen Saturation (SpO2) %^Percent^UCUM % BPM Pulse Rate (PR) {beats}/min^beats per minute^ucum BPM (1/min) PI Perfusion Index (PI) %^Percent^UCUM % SpCO Carbon Monoxide (SpCO) %^Percent^UCUM % SpMet Methaemoglobin (SpMet) %^Percent^UCUM % SpHb Noninvasive Haemoglobin (SpHb) g/dl^g/dl^ucum g/dl CAO2 Oxygen Content (SpOC) ml/dl^ml/dl^ucum ml O2/dL blood PVI Pleth Variability Index (PVI) %^Percent^UCUM % RR Acoustic Respiration Rate (RRa) {breaths}/min^breaths per minute^ucum Breaths/min PORR Pleth Respiration Rate (RRp) {breaths}/min^breaths per minute^ucum Breaths/min PSIF Patient State Index (PSI) {PSI}^PSI^UCUM (dimensionless index)

WHITEPAPER Identifier (OBX-3) Vital Sign Units (OBX-6) Unit of Measure SUPB Suppression Ratio %^Percent^UCUM % EMGB Electromyography %^Percent^UCUM % ARTB Artifact %^Percent^UCUM % EMG_SEFL Spectral Edge Frequency Left Hz^Hz^UCUM Hz EMG_SEFR Spectral Edge Frequency Right Hz^Hz^UCUM Hz EtCO2 End-tidal CO2 %^Percent^UCUM % FiCO2 Fractional Concentration of Inspired CO2 %^Percent^UCUM % EtCO2RR Capnography Respiratory Rate {breaths}/min^breaths per minute^ucum Breaths/min Sample Outbound Message A full sample SafetyNet Message is found below, including outbound results: MSH ^~\& PSN PSN 20111021175130.7370-0700 ORU^R01 92176046-e469-4d34-9e56-711ab3adeb04 P 2.4 NE NE PID 27^3^M10 LASTNAME^FIRSTNAME^MIDDLE^^^^ 19650404 M ^^^^^^P~^^^^^^VACAE~^^^^^^VACAA~^^^^^^VACAC~^^^ ^^^VACAM~^^^^^^VACAO PV1 I MED/SURG^201^2 OBR 1 8224e161-89a1-4fe8-aad2-a4c5578ab635^^000180ffff7f0b15^EUI-64 0609c6eb-d8ce-4180-b73d- 343c922f2776^^000180ffff7f0b15^EUI-64 44616-1^Pulse oximetry panel^ln 20130328160302.2739-0500 252465000^Pulse oximetry^sct 255238004^Continuous^SCT OBX 1 NM SpO2 1.0.1.1 99 %^Percent^UCUM F 20130328160302.2739-0500 OBX 2 NM BPM 1.0.1.2 82 {beats}/min^beats per minute^ucum F 20130328160302.2739-0500 OBX 3 NM PI 1.0.1.9 19.60 %^Percent^UCUM F 20130328160302.2739-0500 OBX 4 NM SpCO 1.0.1.5 1 %^Percent^UCUM F 20130328160302.2739-0500 OBX 5 NM SpMet 1.0.1.4 1.0 %^Percent^UCUM F 20130328160302.2739-0500 OBX 6 NM SpHb 1.0.1.3 8.9 g/dl^g/dl^ucum F 20130328160302.2739-0500 OBX 7 NM CAO2 1.0.1.6 0.1 ml/dl^ml/dl^ucum F 20130328160302.2739-0500 OBX 8 NM PVI 1.0.1.8 37 %^Percent^UCUM F 20130328160302.2739-0500 OBX 9 NM RR 1.0.2.1 21 {breaths}/min^breaths per minute^ucum F 20130328160302.2739-0500 OBX 10 NM PORR 1.0.1.7 0.0 {breaths}/min^breaths per minute^ucum F 20130328160302.2739-0500 Note: SafetyNet supports integration with third-party patient monitors, which generate additional vital signs measurements, with their own HL7 parameter definitions. These messages are configurable and are not included in this document. Message Acknowledgement (Outbound) The Patient SafetyNet HL7 interface sends an acknowledgement message for each received message to the sending system. Time Synchronisation (Inbound) The Patient SafetyNet appliance can be configured to synchronise its clocks with other systems in the institution using Network Time Protocol (NTP). 2

PATIENT SAFETYNET HL7 INTERFACE SPECIFICATIONS MESSAGE FORMATTING Character Encodings The SafetyNet HL7 interface currently supports the following message character encodings: > > ASCII > > UTF-8 Unicode > > ISO 8859-1 INTERFACE DEPLOYMENT Interface Deployment Process The standard deployment process for the Patient SafetyNet HL7 interface is as follows: > > The Masimo Project Implementation Team sets up a formal project with the customers. > > The customer provides sample ADT messages and identifies key data fields. > > Masimo installs the SafetyNet Appliance and provides the customer with an HL7 interface IP address and port number. > > When outgoing result reporting is required, the customer identifies the desired parameters and reporting frequency of the vital signs data. > > The customer sends sample ADT message to the interface when possible. > > Interface testing: Masimo and customer develop interface test plan. > > Interface sign off and turn the interface to production. Below is the interface deployment workflow: Add HL7 Deployment plan to the overall project implementation plan setup with the customer Customer provides sample HL7 ADT sample messages Masimo install HL7 test appliance Agree on desired vitals to be reported and frequency (when vital outbound is required) Customer sends test HL7 ADT message to the interface when possible Interface testing: Masimo and customer develop interface test plan Interface sign off and turn the interface to production Interface Deployment Workflow

WHITEPAPER Interface Testing Masimo and the customer may develop an interface test plan that includes test cases for verification. Example test cases are shown: Registration Function Expected Trigger Comments Admit a patient to Location A Update demographic data Transfer patient to Location B A01 A08 A02 Discharge patient A03 Register ED patient A04 Admit ED patient to Location C A06 Transfer patient to Location A A02 Register ED patient A04 Admit ED patient to Location B A06 Swap patient beds A17 Discharge patient A03 Admit a patient to Location A A01 Update demographic data A08 Cancel admit A11 Register ED patient A04 Admit ED patient to Location A A06 Transfer inpatient to outpatient A07 Admit patient to Location A A01 Move patient account A35 Transfer patient to Location B A02 Update patient demographic A08 Discharge patient A03 Inbound/Outbound Message Configuration Masimo can configure SafetyNet HL7 interface for any inbound messages to smooth and facilitate the interface deployment process. Providing sample ADT messages early in the interface deployment process stages helps to identify any configuration needed in the interface before starting interface testing.

PATIENT SAFETYNET HL7 INTERFACE SPECIFICATIONS Initial Patient Index Synchronisation Before going live with the system, Patient SafetyNet needs to synchronise its patient roster with the current set of admitted patients for the nursing units where the system is deployed. There are two approaches to accomplish this: > > Enable the ADT message feed with enough time (e.g., two weeks) prior to the Patient SafetyNet system going live, or > > Populate a comma delimited file with the currently admitted patients. Masimo uploads the patient information to the SafetyNet HL7 patient roster before the customer enables the HL7 ADT message feed when the SafetyNet system goes live. Below is a sample suggested format for the file: Unit Description Unit^Room^Bed MRN Account Name DOB Age Sex Admit Dt A SURGERY ICU A A^112^A XXX-XXX-XX 999999 First Name, Last Name 3/2/1987 26 M 3/23/2012 B SURGERY ICU B B^114^B XXX-XXX-XX 999999 First Name, Last Name 4/6/1954 59 M 5/15/2012 C SURGERY ICU C C^118^C XXX-XXX-XX 999999 First Name, Last Name 2/9/1990 23 M 9/9/2012 DATA PRIVACY AND PHI Patient SafetyNet has been designed in compliance with the requirements of the HIPPA regulations. Patient SafetyNet stores a minimal set of patient Protected Health Information (PHI) and maintains it in an access controlled environment made available for clinicians to use during the admission process in SafetyNet (see Patient SafetyNet Admission section 7). The SafetyNet HL7 interface uses the patient information to identify vital signs to patients in outbound messages. SafetyNet does not use any of the PHI data except for sending patient vital sign outbound messages. The patient information fields are as follows: Field Name Given Name (PID-5-2) Family Name (PID-5-1) Middle Name (PID-5-3) Patient ID (MRN) (PID-2 and/or PID-3) Patient Account Number (PID-18) Room Number/Point of Care/Bed (PV1-3) Admit Status SSN (PID-19) Religion (PID-17) Marital Status (PID-16) Sex (PID-8) Date of Birth (PID-7) Patient Class (PV1-2)

WHITEPAPER PATIENT SAFETYNET ADMISSION To provide more insight into the SafetyNet admission process and how Patient ADT information will be used, a step-bystep outline of the SafetyNet admission process is shown below. The admission starts with the user selecting a device from the SafetyNet user interface: Next, the user presses the Patient Admit Button to access the admission interface as shown below: The user can access the list of patients in the appropriate units as received from the HL7 ADT message feed by pressing the Import button.

PATIENT SAFETYNET HL7 INTERFACE SPECIFICATIONS The user selects a patient and presses Apply. Patient information is automatically populated. INTERFACE MANAGEMENT AND TECHNICAL SUPPORT > > Masimo provides 24/7 technical support for all products via phone number 800-326-4890. Customers need to choose option #2 for technical support. Contact information can be found on Masimo's website, http://www.masimo. com/contact.htm. > > Masimo has three levels of technical support within the company and 99% of issues are directly resolved within level 1 and level 2 technical support. Other problems can be escalated to level 3 technical support within Masimo s Engineering group. > > Masimo s Service Level Agreement for technical support specifies a response within 30 minutes during normal working hours. Normal working hours are from 6:00am to 5:00pm PST, Monday through Friday. After hours, Masimo will provide a technical support response within two hours.

WHITEPAPER REFERENCES 1 http://ihe.net/technical_framework/index.cfm#pcd 2 This functionality is intended to conform to the Consistent Time (CT) profile of the IHE IT Infrastructure Technical Framework; see http://ihe.net/technical_framework/upload/ IHE_ITI_TF_Vol2a-2.pdf for details.