Data-Logging Rain Gauge PRODUCT MANUAL



Similar documents
A-Series Data Loggers PRODUCT MANUAL

1000 Series Data Loggers PRODUCT MANUAL

Global Water Instrumentation, Inc.

No Rainfall Data is Collected

Tipping Bucket Rain Gauge Models 6011-A 6011-B

USER MANUAL. Rain Collector. with Mountable Base. Product numbers 7857 and 7857M

Soil Sensor Reader PRODUCT MANUAL

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

The Fan-Aspirated ISS includes these components: Metric Rain Adapter. The hardware shown here is provided for assembly and mounting:

Auto Sentry-eXP Maintenance

Spectrum Technologies, Inc.

Wind Direction Smart Sensor (S-WDA-M003)

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Micrio WS1 Replacement Wind Speed Sensor and WC1 Replacement Wind Compass Sensor for Raymarine ST50 and ST60 Wind Instruments. Rev 4.

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Wiper Motor Marinco 2.5. Installation Instructions

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

User's Guide. Integrating Sound Level Datalogger. Model Introduction

el-720 Carbon Dioxide Gas Leak Detector User s Guide

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Retractable Screen. Replacement Screen Instructions

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Gold Century GC-1023 Metal Detector

Advantium 2 Plus Alarm

Vantage Pro2 Temperature/Humidity Sensor Replacement Kit

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

ECM-D70T / ECM-D70T1.5

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

INSTALLATION AND OPERATING INSTRUCTIONS

16/32 Channel 1U Rack Mount CCTV Power Supply

WindLog User s Guide

Global Water Instrumentation, Inc.

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Two-wire interface suitable for measuring mechanical and electrical contact closures Maximum input frequency 1 Hz (1 pulse per second)

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

Milwaukee USER MANUAL

PL-1, Pocket Logger B

Processor Cage Fans, Front and Rear Replacement Instructions

CappController Pipette Controller. Operation Manual Version:

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

MTX-D, Oil Temperature/Pressure Gauge

OPL BASIC. Dosing System for Professional Laundry machines. Contents

ROTOR LOADER OWNER S MANUAL

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Installation Operation Maintenance Troubleshooting

User's Guide Integrating Sound Level Datalogger Model

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

MIRAGE. Set-Up Instructions.

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Front Panel Board Cable Replacement Instructions

u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions

Hobo Pendant Event Logger Manual

Remote Head REMO ONE. Code Manual

u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

EasyNote TJ Series. Disassembly Manual

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

MAC FAUCETS. Owner s Manual. Models: FA444

Tracking Key II User s Guide.

Automatic Phone-Out Home Monitoring Systems

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

TROUBLESHOOTING DITTING COFFEE GRINDERS

Sip/Puff Switch User Guide

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

User manual DinaSys DTC/DTS and DTC/DTZ

FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series

Master Code 2. Troubleshooting: Installation 7. Troubleshooting: Door Jamming and Door Handing 8. Troubleshooting: Keypad 12

Quick Start Guide See Inside for Use and Safety Information

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

ExStik TM ph Waterproof Meters

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

Global Water Instrumentation, Inc.

Drop Counter Sensor Product Number: ENDRP-AD100

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part #

4.3-inch Back-Up Camera

USB Scrolling Optical Mini Mouse

About Your NetBotz 4-20mA Sensor Pod

Wireless Indoor/ Outdoor Thermometer

RAIN COLLECTOR S HELF MANUAL

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

site monitoring Kit Site Monitoring Kit User Manual we prove it.

7 High-Resolution Digital Photo Frame

TV Ears 5.0 Digital & Dual Digital Quick Start Guide

VOYAGER 570G. 744A Sprayer Control

Installation, Operation & Service Manual

TABLE OF CONTENTS 11.0 WARRANTY

Transcription:

Data-Logging Rain Gauge PRODUCT MANUAL Item # 3554WD1

Thank you for purchasing a Spectrum Datalogging Rain Gauge. With proper installation and care, it will give you years of accurate and reliable measurements. This instruction manual takes you through the procedures required to set up and use the Datalogging Rain Gauge. Read it thoroughly to insure proper and effective use of the sensor. The datalogger records rain activity over time when connected to a tipping-bucket type rain collector. The logger records accumulated rainfall during each interval (maximum of 2.55 per interval). Specifications: Type: Self-emptying tipping bucket Resolution: 1/100 inch (0.254mm) Accuracy: ±2% with rainfall at < 2 in (5 cm) per hour Event type: Tip (relay contact opening) Event intervals: 1, 5, 10, 15, 30, 60 Capacity: 10584 intervals; with a maximum of 10.23 (260mm) per interval Battery: CR2450 (replace every year) 2 Verifying the Rain Collector is Recording Data Requires Specware 9 Basic or Pro (Build 247 or later) 1. Remove the rain funnel from the base of the unit (see page 3 on how to remove the rain funnel). The funnel MUST be removed in order to test the rain collector. 2. Connect the gray cable into the logger 3. Open Specware 4. Click on the Launch/Set Properties for Watch- Dog 1000 or 2000 Series 5. Verify port A in the properties screen is Enabled, Sensor/Unit is Rainfall, and click on the Update button. 6. Manually move the tipping spoon back and forth five (5) times 7. Click on Update button a second time. 8. Verify the Reading for Rainfall has incremented accordingly.

Assembly The aluminum mounting bracket needs to be attached to the rain collector. Turn the collector upside down. Note the four holes (circled at right) that will be used for screws to attach the bracket. Set the bracket on the collector, lines up the holes in the bracket with those in the collector. If only two of the four holes line up, rotate the bracket 1/4 turn. Attach the bracket to the collector using the four machine screws included. The datalogger is enclosed in a storage cavity under the collector cone (see below). To access the logger, loosen the four screws which secure the cone to the base. Rotate the cone from the base until the screws are free from the latches and separate the cone from the base. Remove the colored cap from the cylindrical cavity and remove the datalogger (it may be disconnected from the right-angle connector at any time). Use SpecWare software to program the WatchDog to log rainfall. Connect the logger to your PC using the interface cable provided with the software. Measurements can be recorded in metric or US units. Refer to the SpecWare User s Guide for detailed launch and/or readout instructions. 3

When choosing a location for your rain collector, keep the following in mind: Verify data is being recorded prior to installing refer to page 2. Mount the collector on a 1-1.25 (25-32mm) mast (pipe) using the provided u-bolts, or a wooden post using the screws. Make sure the collector is level when positioning the mast mount. Use a bubble level to check that the collector s base is level. The post or mast MUST be rigid. If the collector moves easily, the wind can create oscillations that may record extra tips, resulting in higher-than-actual rain measurements. The gauge contains a magnet-operated switch which may not operate correctly if you mount the rain collector on or near any object which attracts a magnet. To ease normal cleaning, choose an easily accessible location that is far from trees and other sources of pollen or debris. The rain gauge must be located in an open area. Installation 4

Maintenance Inspect the collector frequently to make certain it is still level and clear of obstructions. For greatest accuracy, you should thoroughly clean and calibrate the rain collector at least once or twice a year. Remove the collector cone to clean the tipping bucket using a mild detergent and respraying with Elmer s Slide-All. This teflon spray can be obtained at your local hardware store. Note: Disconnect the logger from the rain collector to avoid any inadvertent counts on the logger when cleaning. Troubleshooting Unable to contact the logger in SpecWare 1. The most likely cause is a low battery in the logger. Replace the battery with a fresh one using the instructions in the Battery Replacement section. 2. See the SpecWare Quick Start Guide or User Guide for instructions concerning assigning communications ports. The logger is reading low, or not at all 1. Check the inside of the rain bucket for debris such as leaves that may be blocking the grid at the bottom of the bucket. Remove the rain bucket from the base and check for any obstacles (spider webs, debris, etc.) that may be preventing the tipping spoon from moving freely. If the hole beneath the grid gets clogged with dirt, the cotter key can be removed to allow it to be cleared. 2. Check that the rain sensor is connected to port A (see pg. 7) 3. Launch the logger, setting it to one minute intervals, so it can count the rain measurements. 4. Manually move the tipping bucket back and forth several times (counting the tips). After a minute, download the logger 5

and check if the tips have been recorded. Do this several times. 5. If the tips are being counted correctly, but the logger is reading low, go to the Calibration section. 6. If the logger is not registering any or all of the manual tips of the bucket, it may be that the magnet on the tipping bucket (the black bulb) is too far from the reed switch (located on the small green circuit board). There are 2 cams on the base of the rain collector that hold the tipping bucket axle in place. These can be rotated to move the tipping bucket closer to or further away from the reed switch. Loosen the screws slightly, and rotate the two plastic disks clockwise to bring the magnet closer to the reed switch, or counterclockwise to move the magnet and switch further apart. Repeat the test in steps 2 and 3. If the logger can now detect the correct number of manual tips of the bucket, then proceed to the Calibration section, if required. 7. After performing step 5 the logger is still not registering any or all of the manual tips of the bucket, then it is likely that either the reed switch or the sensor cable is not functioning. Please contact Spectrum Technologies for service or replacement parts. The logger is not reporting the same results as another rain gauge There may be nothing wrong. Rainfall is extremely variable, over even short distances. Iowa State University Extension agronomist Mike White measured rainfall in 17 locations within a 40 acre field for two growing seasons. Total seasonal rainfall varied within the field from 9.65 to 11.48 in 1997 and from 11.84 to 13.43 in 1998. These numbers were for an entire season so individual storm differences could begin to cancel each other out. So one can expect noticeable differences between two rain gauges even a short difference apart. 6

Calibration If the rain gauges are differing over a very short distance, then cal Calibrate the tipping bucket rain gauge only after performing the steps in the maintenance section of this manual. 1. Launch the logger, setting it to one minute intervals, so it can count the rain measurements. 2. Measure 84 ml of water into a Zip-Lock bag. 3. Puncture the bag with a pin and place it in the bucket so the water will slowly enter the bucket. 4. When the water is gone, remove the logger and download the data. 84 ml of water should register 0.10 inches of water (2.5 mm). This is equivalent to 10 tips of the tipping spoon. 5. If greater measurement accuracy is required, use 840 ml of water, which should register 1.00 inches (25.4 mm), and is the equivalent of 100 tips of the tipping bucket. Battery Replacement The datalogger is powered by a 3 Volt CR2450 battery. It is user replaceable and can be purchased locally. We recommend changing the battery every year. To replace the battery: 1. Remove the logger from the storage cavity and unplug the 2.5 mm sensor cable. 2. Slide the plastic cover gently upward to expose the battery holder 3. Slide the battery out of the battery holder. 4. Insert a new CR2450 battery positive side up. 5. Slide the plastic cover back over the electronic board. Insert a flat-edged screwdriver completely underneath old battery. Gently lift edge of battery over casing lip and slide battery out. Slide new battery into battery casing. Port A 7

Warranty This product is warranted to be free from defects in material or workmanship for one year from the date of purchase. During the warranty period Spectrum will, at its option, either repair or replace products that prove to be defective. This warranty does not cover damage due to improper installation or use, lightning, negligence, accident, or unauthorized modifications, or to incidental or consequential damages beyond the Spectrum product. Before returning a failed unit, you must obtain a Returned Materials Authorization (RMA) from Spectrum. Spectrum is not responsible for any package that is returned without a valid RMA number or for the loss of the package by any shipping company. DECLARATION OF CONFORMITY Spectrum Technologies Inc. Model Numbers: 3554WD Description: Datalogging Rain Gauge Type: Electrical equipment for measurement, control, and laboratory use Directive: 2004/108/EC Standards: EN 61326-1:2006 EN 61000-4-2:1995, including A1:1998 and A2:2001 EN 61000-4-3:2002 EN 55011:2007 Spectrum Technologies in Europe ESTEDE Business Solutions bv 7121 BE Aalten, the Netherlands Telephone +31 (0)543 472334 Email: info@specmeters.eu WWW.SPECMETERS.EU Rev. 06/13 8