International Beryllium Conference, Montreal, Canada March 10, 2005



Similar documents
Carboxyfluorescein succinimidyl ester-based proliferative assays for assessment of T cell function in the diagnostic laboratory

Uses of Flow Cytometry

CFSE Cell Division Assay Kit

Introduction to Flow Cytometry

TABLE OF CONTENT. Page ACKNOWLEDGEMENTS. iii ENGLISH ABSTRACT THAI ABSTRACT. vii LIST OF TABLES LIST OF FIGURES. xvi ABBREVIATIONS.

EdU Flow Cytometry Kit. User Manual

Introduction to Flow Cytometry

Assays to evaluate cell-mediated immunity. Guus Rimmelzwaan Department of Virology Erasmus Medical Center Rotterdam The Netherlands

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Introduction to flow cytometry

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

BD Pharmingen. Apoptosis, DNA Damage and Cell Proliferation Kit. Technical Data Sheet. Product Information. Description. Material Number: Size:

Flow Cytometric Analysis of Leishmania Reactive CD4 + /CD8 + Lymphocyte Proliferation in Cutaneous Leishmaniasis

APPLICATION INFORMATION

Potency Assays for an Autologous Active Immunotherapy (Sipuleucel-T) Pocheng Liu, Ph.D. Senior Scientist of Product Development Dendreon Corporation

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

STANDARD OPERATING PROCEDURE

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

CyAn : 11 Parameter Desktop Flow Cytometer

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed

BrdU Flow Kits. Instruction Manual. FITC BrdU Flow Kit. APC BrdU Flow Kit. BD Pharmingen. Cat. No (50 tests) Cat. No (4 50 tests)

Immunophenotyping peripheral blood cells

PRODUCT INFORMATION SHEET Monoclonal antibodies detecting human antigens

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

Chapter 18: Applications of Immunology

低 剂 量 辐 射 对 脐 血 T 淋 巴 细 胞 膜 分 子 表 达 的 影 响 EFFECT OF LOW DOSE IRRADIATION ON EXPRESSION OF MEMBRANE MOLECULES OF T LYMPHOCYTES IN CORD BLOOD

Expression of CD163 on Bovine Alveolar Macrophages and Peripheral Blood Mononuclear Cells

Below is a list of things you should be aware of before you schedule your sort.

COMPENSATION MIT Flow Cytometry Core Facility

Lab 2. Isolation of mononuclear cells from peripheral blood and separation into subpopulations

CONTENT. Chapter 1 Review of Literature. List of figures. List of tables

Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

FlowSight. Flow cytometry with vision

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

NCL Method ITA-14. Analysis of Nanoparticle Effects on Maturation of Monocyte Derived Dendritic Cells In Vitro

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Flow Cytometric Diagnosis of Low Grade B-cell Leukemia/Lymphoma

specific B cells Humoral immunity lymphocytes antibodies B cells bone marrow Cell-mediated immunity: T cells antibodies proteins

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection

Activation and effector functions of HMI

Principles of Flowcytometry

Cell Viability Assays: Microtitration (MTT) Viability Test Live/Dead Fluorescence Assay. Proliferation Assay: Anti-PCNA Staining

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

Chapter 6. Antigen-Antibody Properties 10/3/2012. Antigen-Antibody Interactions: Principles and Applications. Precipitin reactions

T Cell Maturation,Activation and Differentiation

Supplemental Information. McBrayer et al. Supplemental Data

Whole Blood Flow Cytometry

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Cell Viability Measurement

Basic Science in Medicine

Cell Cycle Tutorial. Contents

EZ-BrdUTM. A Complete Kit for Measuring Cell Proliferation using BrdU by Flow or Image Cytometry. Catalog No. AC1001

Standard Operating Procedure

Hoechst HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, )

LIVE/DEAD Fixable Dead Cell Stain Kits

use. 3,5 Apoptosis Viability Titration Assays

Cell Cycle Phase Determination Kit

INSIDE THE BLACK BOX

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

BERYLLIUM LYMPHOCYTE PROLIFERATION TESTING (BeLPT)

Fluorescence Compensation. Jennifer Wilshire, PhD

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

Microbiology AN INTRODUCTION EIGHTH EDITION

a Beckman Coulter Life Sciences: White Paper

Immunomodulatory Effects of Mycobacteria. Toh S.S. 1 and Seah G.T. 2

Standardization, Calibration and Quality Control

BD Trucount Tubes IVD

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences

Comparison of Trypan Blue and Fluorescence-Based Viability Detection Methods Via Morphological Observation

Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

FASTIMMUNE Assay System A Rapid and Comprehensive System for Assessing Lymphocyte Function by Flow Cytometry

Human CD4+T Cell Care Manual

RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)

CD3/TCR stimulation and surface detection Determination of specificity of intracellular detection of IL-7Rα by flow cytometry

The Journal of Experimental Medicine

Pulling the Plug on Cancer Cell Communication. Stephen M. Ansell, MD, PhD Mayo Clinic

The Costimulatory Molecule CD27 Maintains Clonally

Multiple Myeloma and Colorectal Cancer

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Notes on titering antibodies

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry

Islet Viability Assessment by Single Cell Flow Cytometry

2) Macrophages function to engulf and present antigen to other immune cells.

Modelling and analysis of T-cell epitope screening data.

Chapter 43: The Immune System

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Transcription:

Alternative Lymphocyte Proliferation Tests: BrdU and Flow Cytometry Based Tests International Beryllium Conference, Montreal, Canada March 10, 2005 Tim K. Takaro Department of Environmental and Occupational Health Sciences University of Washington Seattle, WA, USA ttakaro@u.washington.edu

Introduction CBD is a delayed-type hypersensitivity reaction due to a cellmediated immune response in the lung. Lymphocyte recognition of beryllium presented in association with MHC II molecules on APCs results in the generation of beryllium-specific effector lymphocytes. Exposure of these lymphocytes to beryllium in vitro causes them to undergo cell division, as determined by incorporation of 3 H-thymidine, BrdU or 5,6 carboxyfluorescein diacetate succinimidyl ester (CFSE) into cellular DNA. This incorporation into dividing cells constitutes the basis of the lymphocyte proliferation test (LPT) used to identify Besensitized people.

Background Information provided by the traditional LPT limited to estimation of stimulation index due to 3H-thymidine incorporation only during the S phase in stimulated lymphocyte cultures, limiting number of responsive cells. Non-proliferating bystander cells may confound results. Fluorescent markers used with flow cytometry can test for beryllium sensitization, identify and quantify the specific cell types responding to beryllium, and can be linked with analyses of cell cycle and functional protein production, generating additional useful information compared with standard LPT. Flow cytometry with multiparametric analysis provides an alternative LPT method for highly heterogeneous cell populations in cell-mediated immune responses at the single cell level.

Background (2) Flow technique first reported use in CBD by LANL Biosciences in 2000*. BrdU incorparated into DNA (T --> U) as cells proliferate, then stained w/ anti-brdu FITC, and additional stains as desired for phenotyping and cell cycle analysis. 7 CBD and 120 beryllium exposed workers tested. 4 BeS detected by both standard and flow methods, as were CBDs. CBD cases exhibited strong CD4+ (T-helper) and CD8+ (T-killer) proliferation, while BeS showed mainly CD8+ proliferation. Authors recommended that this immuno-be-lpt be used to confirm results of standard clinical BeLPT. * Farris, et al (2000) Toxicology 143:125-140

BrdU Incorporation Method Andreas Thiel, et al.(2004).clinical Immunology 111: 155.

Background (3) Another flow cytometry-based method uses labeling with BrdU and BrdU-mediated stoichiometric quenching of the DNA intercalating dye Hoechst 33258. Proliferating cells with incorporated BrdU identified by decreased Hoechst fluorescence compared to nonproliferating cells, w/ each cell division producing less fluorescence intensity due to quenching. The position of the cells within the cell cycle identified by counter staining with a second DNA dye (e.g. 7-AAD, PI, EB) whose fluorescence is unaffected by BrdU. The BrdU-Hoechst assay can also be combined with immunolabeling using monoclonal antibodies to cell surface receptors and intracellular cytokines for simultaneous analysis of proliferation, cell phenotype and effector cytokine production.

BrdU-Hoechst Methods Isolate Peripheral Blood Lymphocytes (PBL) from CBD patients (Ficoll-Paque density gradient centrifugation) Culture PBL in RPMI medium + 10% Fetal Bovine Serum + 150 µmbrdu at 5 X 10 6 cells/ml Expose to either BeSO 4, PHA or Tetanus toxin Incubate cells in the dark for either 3 days (PHA), or 4-6 days (Be or TT) Harvest and fix cells (saponin + 0.25% PFA) Immunolabel cells with subtype-specific fluorescent Mab Stain nuclei with Hoechst 33258 + Ethidium Bromide (EB) or 7-AAD Multiparameter flow cytometry for simultaneous analysis of cell proliferation and immunophenotype

FACS 4-Channel Flow Cytometer

Simultaneous immunophenotyping and proliferation analysis of PBL stimulated in vitro with tetanus toxin Total Population CD4+ CD8+

BrdU/Hoechst- EB flow cytograms of PBL from a CBD patient. PHA Tetanus Toxin FBS Control EB Fluorescence G2 G2 G2 S S S G1 G1 G0/G1 0.5 um Be G1 G1 5 um Be G0/G1 G1 G1 50 um Be G0/G1 G1 G1 G0/G1 G1 G1 G0/G1 G1 G1 G0/G1 Hoechst Fluorescence

Quantitation of cells exiting G0/G1 Treatment % Proliferating Cells Day 3 Day4 Day6 FBS Control 0.2±0.2 0.2±0.2 0.5±0.3 PHA 52±1.5 Tetanus 3.9±1.4 BeSO 4 0.5 um 2.6±0.4 3.4±0.8 5.0 um 4.4±0.7 5.7±0.7 50 um 6.1±1.0 7.3±0.9

Be Stimulation Index (ratio of Be stimulated proliferation to FBS control) 15 Day 4 12.5 Day 6 CBD1 Stimulation Index 10 5 10 7.5 5 2.5 CBD2 CBD3 CBD4 0 0.5 5 50 0 0.5 5 50 BeSO 4 (µm)

Kinetic analysis of the proliferative response to beryllium DAY 4 DAY 6 DAY 4 DAY 6 % CELLS ENTERING 1 ST CYCLE % CELLS COMPLETED 1 ST CYCLE BrdU 0.4±0.1 0.5±0.3 0.3±0.2 0.8±0.3 0.5 µm BeSO 4 0.6±0.2 0.3±0.2 1.2±0.1 3±0.2 5 µm BeSO 4 0.9±0.5 0.5±0.3 3.3±0.4 5.3±0.5 50 µm BeSO 4 1.9±0.2 0.7±0.2 4.3±0.9 7.4±0.6

Immunophenoptyping of lymphocytes from CBD patient 100 Resting cells 100 Proliferating cells Untreated 80 60 75 Be (20 µm) Be (2 µm) 50 40 20 25 0 0 CD4 CD3 CD19 CD4 CD3 CD19 Surface Marker

Rossman Lab Methods * Isolate Peripheral Blood Lymphocytes (PBL) from BeS patients (Ficoll-Paque density gradient centrifugation) Culture PBL in RPMI medium + Heat inactivated human serum Following 10 min. staining with CFCE Expose to either BeSO 4 (10 or 100 um), PHA or Candida Incubate cells 37º C for 7 days One set pulsed with 3 H thymidine in standard fashion One set harvested and fixed (saponin + 2% formaldehyde) Immunolabel cells with subtype-specific fluorescent monoclonal antibody CD3-Tri-color (TC) CD4- Phycoerythrin (PE) CD8- allophycocyanin (AC) FACS 4-color flow cytometer (CFSE FL1, CD4 FL2, CD3 FL3, CD8, FL4) 50,000 events collected and analyzed using CellQuest software *Milovanova et al, Clinical Cytometry (2004) 60B:23-30

5,6 Carboxyfluoroscein Diacetate Succinimidyl Ester (CSFE) Andreas Thiel, et al.(2004).clinical Immunology 111: 155.

Rossman Lab Methods (2) Proliferative ratio calculated on Day 7: % divided cells/ % undivided cells 9 normal unexposed controls 24 BeS (two pos BeLPTs) 4 CBDs, 7 Be alveolitis, 13 non-diseased

GATING: R1 light scatter to determine lymphocyte population R2 live CD3+ cells R3 CD3+,CD4+ cells

Milovanova, et al. 2004 BeS individual, with CFSE labeled CD3+, CD4+ T-cells cultured for 7 days.

Milovanova, et al. 2004 p < 0.05 BeS vs. controls

Milovanova, et al. 2004

Limitations Nucleotide analogue incorporation not always correlated well with increased DNA content and cell proliferation due to incomplete incorporation. These flow cytometric techniques performed only under research conditions to date. Full validation studies need to be done before questions of improved performance over traditional LPT can be answered.

Conclusions These non-radioactive assays of beryllium sensitization can measures cell proliferation in response to beryllium using continuous BrdU or CFSE labeling of cultured cells with standard clinical laboratory cytometers. Results suggest that continuous labeling could be more sensitive than the standard LPT assay since all cells that incorporate BrdU throughout the culture period are measured rather than those that just happen to be in S phase at the time of 3 H-thymidine pulse-labeling. Dead cells are not counted, and multiple cell divisions can be measured. Knowing specific proliferating cell-types can add specificity to the test. In addition, the flow cytometry method incorporates additional mechanistic and kinetic information. Discrimination of the responding population can be simultaneously determined using cell surface or cytokine immunophenotyping. Flow cytometry can be successfully performed using about 1/3 number of cells than traditional BeLPT

Acknowledgements Abdullah Jabbour, PhD, Terry Kavanagh, PhD, University of Washington Lee Newman, MD, MA, Lisa Maier, NJMRC UW Department of Pathology Flow Cytometry Facility: Peter Rabinovitch,M.D. Ph.D., Juliane Hill, M.S. NJMRC Laboratory and support staff. Beryllium exposed workers who contribute to the quest for more knowledge Funding by: DOE Cooperative Agreement DE-FCO1-95EW55084 NIEHS UW Superfund Basic Research Program

Effects of exogenous IL-2 on beryllium-induced PBL proliferation Day 4 Day 6 16 -IL2 16 % Proliferating Cells 12 8 4 +IL2 12 8 4 0 0 0 52 50 20 0 52 50 20 BeSO4 (µm)