NIBE F2040 AIR/WATER HEAT PUMP STRONG AS A VIKING. NIBE F2040. Optimal annual heating factor thanks to the inverter controlled compressor.



Similar documents
NIBE F2300 air/water heat pump. Strong as a viking. NIBE F2300. New efficient scroll compressor that operates at temperatures down to -25 C.

NIBE FIGHTER 2020

Technical data. Danfoss DHP-A

HP switch LP switch Discharge thermo Comp. Surface thermo

NIBE ACCESSORIES. NIBE Accessories A NEW GENERATION OF HEAT PUMPS

Aerona Air Source Heat Pumps

ECOCIAT. Domestic hot water heat recovery unit

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

INSTALLATION AND MAINTENANCE INSTRUCTIONS F F2025

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Installation and maintenance instructions. Danfoss Vent

SWIMMING POOL HEAT PUMP Owners Manual

Failure code manual. content

Meaco 30L and Meaco 40L dehumidifier instruction manual

HEAVY DUTY STORAGE GAS

Condensing unit type EPSILON-ECHOS LE Technical information manual

Portable Air Conditioner

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

york air-conditioning products Residential & VRF News 2015

Transformer oil cooler ALFA A02

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Dehumidifier D 850E. - Instruction manual version 02

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Cooling kw Heating kw

ELECTRIC CENTRAL HEATING FLOW BOILER

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

MOS GB FIGHTER INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE FIGHTER 2020 LEK

NIBE F1145 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1145

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

SWIMMING POOL HEAT PUMP

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

Test Report issued under the responsibility of:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

HERZ-Thermal Actuators

Heat Pumps for Swimming Pools

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

PANASONIC TROUBLE SHOOTING GUIDE

CRAC Precision climate control units for data centres

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Air Conditioners Technical Data

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Overheating limit control

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Topvex SX/C, Topvex TX/C. Air Handling Unit

Laddomat Charging unit

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Conlift1, Conlift2, Conlift2 ph+

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

USER S MANUAL HSC-24A

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Heat Pump Water Heater IOM Manual

Electric Flow Boiler

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

AIR-CONDITIONER SPLIT TYPE

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Appendix - Controllers 179

WINDOW ROOM AIR CONDITIONER

Glossary of Heating, Ventilation and Air Conditioning Terms

User manual. 086U6297 Rev. 9 EN

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Energy Efficiency HOSPITALITY.

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Heat Recovery based on Exhaust Air

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

Air Conditioner Water Heater Model ACWH18

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

PORTABLE AIR CONDITIONER

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Hot Water. Heat pump water heaters. Residential and Commercial R410a

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

SEMTIC ECO THERMA. Luftvärmepump Luft/Vatten

marine/bespoke split applications

Nordic Heat Pump Product Guide

Heat Pump Installation, Maintenance and Service Manual

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Volkswagen Golf > VW Rabbit GTI 2006->

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

Transcription:

NIBE F2040 AIR/WATER HEAT PUMP STRONG AS A VIKING. Optimal annual heating factor thanks to the inverter controlled compressor. Integrated active cooling function. Integrated condensation water trough that together with condensation water pipe KVR 10 prevents icing. F2040 can also be docked to one of NIBE's indoor modules VVM 310, VVM 320 or VVM 500 (accessory). VVM 310, VVM 320 and VVM 500 contains all controls and consists of a water heater and additional heater in the form of an immersion heater. F2040 together with VVM 310, VVM 320 or VVM 500 make up a complete heating installation. F2040 can be controlled from one of NIBE's specially designed controllers, SMO. These connect and disconnect the additional heat and control switching between room heating and hot water heating. The material has a long service life and is designed to withstand the Nordic outdoor conditions. Optimized operating costs. The speed of the compressor is adjusted according to the demand. NIBE F2040 NIBE F2040 is an air/water heat pump, specially designed for the Nordic climate. F2040 utilises the outside air so there is no need for bore holes or coils in the ground. F2040 is designed to be docked to water borne heating systems. Please visit www.nibe.eu for further information.

GOOD TO KNOW ABOUT NIBE F2040 Principle of operation This is a simplified version of how it works. The outdoor air is drawn into the heat pump and meets a closed system. The system contains a refrigerant with the capacity to turn into gas at a very low temperature. Under high pressure, a compressor considerably increases the temperature of the refrigerant, which is now gaseous. Using a condenser, the heat is transferred to the house s heating system, while at the same time the refrigerant reverts to liquid form, ready to turn into gas once more and collect new heat energy. Maintenance F2040 is equipped with control and monitoring equipment, however some exterior maintenance is still necessary. Make regular checks throughout the year that the grilles are not clogged by leaves, snow or anything else. Strong wind combined with heavy snowfall can block the intake and exhaust air grilles. Make sure that there is no snow on the grilles. The condensation drain pan and condensation water/drain pipe may require cleaning from leaves or similar during the year. If necessary the outer casing can be cleaned using a damp cloth. Care must be exercised so that the heat pump is not scratched when cleaning. Avoid spraying water into the grille or the sides so that water penetrates into F2040. Prevent F2040 coming into contact with alkaline cleaning agents. Keep free of snow and/or ice. Docking with hot water and a heating system The heating medium side and the hot water side must be fitted with the necessary safety equipment in accordance with the applicable regulations. -FL2 -CM1 -FL1 -RM1 -QM40 -EB15 -EB101 -EB101 -FL10 -RN10 -QM40 XL1 -HQ1-QM41 XL2 -QM1 Abbreviations EB15 Indoor module (VVM 310) EB101 Heat pump (F2040) (included) FL10 Safety valve, heat pump HQ1 Particle filter (included) QM1 Drain valve, heating medium QM40 Shut-off valve QM41 Shut-off valve RN10 Trim valve Other information CM1 Expansion vessel closed, heating medium EB1 Electric heater FL1 Safety valve, hot water FL2 Safety valve, heating medium QM40 Shut-off valve RM1 Non-return valve 2 NIBE F2040

GOOD TO KNOW ABOUT NIBE F2040 Transport and storage F2040 should be transported and stored vertically. Control F2040 is inverter controlled. Connected indoor module manages all functions that are necessary for heat pump operation. Accordingly, defrosting, stop at max/min temperature, connection of the compressor heater, enabling the heater for the drip pan, monitoring of motor protection and pressure switches are controlled by the indoor module. The inverter controller is set during installation and can be used during a service. Under normal operating conditions the home owner does not need to have access to the controller. Sound pressure levels F2040 is usually placed next to a house wall, this gives directed sound distribution which should be considered. Accordingly, you should always attempt to find a placement on the side that faces the least sound sensitive neighbouring area. The sound pressure levels are further affected by walls, bricks, differences in ground level, etc and should therefore only be seen as guide values. F2040 adjusts the fan speed depending on the ambient temperature and evaporation temperature. Type F2040-8 F2040-12 F2040-16 Sound power level, according to EN12102 at 7/45 Lw(A) 54 57 68 Fan speed Max sound pressure level at 2 m* db(a) 40 43 54 Max sound pressure level at 6 m* db(a) 30,5 33,5 44,5 Max sound pressure level at 10 m* db(a) 26 29 40 * Free field NIBE F2040 3

GOOD TO KNOW ABOUT NIBE F2040 Equipment 2040-8 Electrical components F2040-8 PWB2 PWB3 PWB1 F X1 AA23 QN2 20S AA23-S2 AA23-X4 BT12 EP1 BP1 63H1 BP2 LPT BP4 GQ1 FM01 EP2 F3 BT3 QN3 SM1 BT15 HS1 QM35 QM36 PF3 EB11 GQ10 CM QN1 SM2 EB10 CH UB3 W1 UB1 UB2 XL1 DATA DATA XL2 DH UB3 4 NIBE F2040 PF3 PF1 AA23-X1

GOOD TO KNOW ABOUT NIBE F2040-8, -12, -16 List of components Pipe connections QM35 Service valve, liquid side QM36 Service valve, gas side XL1 Connector, heating medium out of F2040, G3/4 (Q22 mm) XL2 Connector, heating medium in to F2040, G3/4 (Q22 mm) Sensors etc. BP1 (63H1) High pressure switch BT 3 Temperature sensor, heating medium return line BT 12 Temperature sensor, condenser supply line BT 15 Temperature sensor, fluid pipe BP2 (LPT) Low pressure sensor BP4 High pressure sensor Electrical components AA23 Communication board AA23-X1 Terminal block, incoming supply AA23-X4 Terminal block, communication EB10 (CH) Compressor heater EB11 (DH) Drip tray heater F Main fuse, compressor unit F3 Fuse for external heating cable (250 ma), max 45 W GQ1 (FM01) Fan PWB1 Control board PWB2 Inverter board PWB3 Filter board TB Terminal block, electricity and communication X1 Terminal block, incoming Cooling components QN2 (20S) 4-way valve GQ10 (CM) Compressor QN3 (EEV-C) Expansion valve, cooling QN1 (EEV-H) Expansion valve, heating EP1 Evaporator EP2 Condenser HS1 Drying filter Other information PF 1 Type plate PF 3 Serial number UB 1 Cable gland, incoming supply UB 2 Cable grommet, communication UB 3 Cable grommet, heating cable (EB14) W1 Cable, incoming supply Designations in component locations according to standard IEC 81346-1 and 81346-2. NIBE F2040 5

GOOD TO KNOW ABOUT NIBE F2040 Equipment 2040-12 PWB3 PWB1 PWB2 TB X1 EP1 GQ1 BP1 63H1 QN2 20S FM01 BT12 QN3 EEV-C BP4 BT3 BT15 PF3 EB11 DH GQ10 CM QM35 QM36 EB10 CH BP2 LPT HS1 QN1 EEV-H EP2 UB3 UB1 UB2 DATA XL1 DATA W1 XL2 PF3 PF1 UB3 6 NIBE F2040

Front el F2040-12 Rear el F2040-12 Främre el PWB3 PWB1 PWB2 AA23 AA23-X4 F F3 TB AA23-X1 X1 Bakre el Bakre el NIBE F2040 7

GOOD TO KNOW ABOUT NIBE F2040 Equipment 2040-16 EP1 GQ1 FM01 QN2 20S BP1 63H1 QM35 QM36 QN3 SM1 X1 BT12 GQ1 FM01 QN3 SM2 BP4 BT3 BT15 DH EP2 EB11 PF3 UB3 GQ10 CM EB10 CH BP2 LPT HS1 UB1 UB2 DATA XL1 DATA W1 XL2 UB3 PF3 8 NIBE F2040 PF1

Främre el Electrical components F2040-16 PWB3 PWB1 F Bakre el Främre el TB AA23 AA23-S2 AA23-X4 F3 Bakre el AA23-X1 PWB2 Bakre el NIBE F2040 9

GOOD TO KNOW ABOUT NIBE F2040 Dimensions F2040-8 F2040 Ställbar 40-50 855 100 400 670 50 365 422 15 965 1035 225 95 90 Ø40* 10 NIBE F2040

Dimensions F2040-12 Ställbar 40-50 955 110 243 512 255 50 50 395 452 14 1075 1145 265 108 85 Ø40* utrymme bakom m 600mm in. avstånd id användning v flera F2040 Minimalt fritt utrymme NIBE F2040 11

Dimensions F2040-16 Ställbar 40-50 1410 110 243 512 180 50 80 395 452 14 1075 1145 265 108 85 Ø40* 12 NIBE F2040

INSTALLATION F2040 can be connected in several ways. The necessary safety equipment must be installed in accordance with current regulations for all docking options. Inspection of the installation Current regulations require the heating installation to be inspected before it is commissioned. The inspection must be carried out by a suitably qualified person and should be documented. The above applies to closed heating systems. If the heat pump is replaced, the installation must be inspected again. NIBE F2300 + NIBE SMO 20 system SMO 20 is an intelligent control module that, together with, F2040 and existing heating and hot water equipment, creates a complete unit. SMO 20 manages compressor operation in F2040 and, if necessary, the additional power from any type of existing equipment that may be required. SMO 20 also manages circulation pumps, reversing valves and sensors. NIBE F2300 + NIBE VVM 310/VVM320*/VVM500 F2040, together with VVM 310, VVM 320* or VVM 500, creates a complete heating and hot water installation. VVM 310, VVM 320 and VVM 500 are equipped with a control box that currently makes them the most economical operators, both for the integrated immersion heaters (max 12/9 kw) and compressor operation in F2040. VVM 310, VVM 320 and VVM 500 come complete with automatic heating, reversing valve, circulation pump, speed controlled charge pump and safety equipment. With VVM 310, VMM 320 or VVM 500, pool heating is possible as well as extra shunt groups, i.e. two heating systems with different supply temperatures. VVM 310, VVM 320 and VVM 500 are designed for simple connection to F2040. NIBE F2300 + NIBE SMO 40 system SMO 40 is an intelligent control module that, together with, F2040 and existing heating and hot water equipment, creates a complete unit. SMO 40 manages compressor operation in F2040 and, if necessary, the additional power from any type of existing equipment that may be required. SMO 40 also manages automatic by-passes, load guards, circulation pumps, reversing valves and sensors. With SMO 40, pool heating is possible as well as up to three extra shunt groups, i.e. four heating systems with different supply temperatures. Electrical addition Gas boiler Buffer Buffel vessel External addition Controller SMO 20 05 F2040 Room unit F20XX VVM 500 VVM 500 F2040 NIBE F2015-6, -8, -11 NIBE VPB 200N *F2040-8 and F2040-12 (not F2040-16) can be connected to VVM 320. NIBE F2040 13

Ställba 452 14 1075 1145 265 INSTALLATION 85 Installation area The distance between F2040 and the house wall must be at least 150 mm. Leave a space of about 600 mm to the right of the heat pump for servicing. Clearance above F2040 must be at least one metre. A clear space of 3 m is needed in front of the heat pump. Do not place F2040 directly on the lawn or other non solid surface. If there is a risk of roof slides a protective roof or similar should be installed over the heat pump, pipes and wiring. Ø40* 150 mm Free Fritt space behind utrymme bakom 400 mm 400 mm 600 mm 600mm Min free space Minimalt fritt utrymme Free space in front Fritt utrymme framför 3000 mm mm Min free space Minimalt fritt utrymme Installation and positioning Position F2040 outdoors on a firm and level surface that can take the weight, preferably a concrete foundation. If concrete slabs are used these should lie on tarmac or gravel. The concrete foundation or slabs must be positioned so that the lower edge of the evaporator is at the level of the average local snow depth, although a minimum of 300 mm. F2040 should not be positioned next to sensitive walls, for example, next to a bedroom. Also ensure that the placement does not inconvenience the neighbours. F2040 must not be placed so that recirculation of outdoor air can occur. This causes lower output and impaired efficiency. The evaporator should be sheltered from direct wind. Place F2040 so that the evaporator is protected from wind. Condensation water as well as melt water from defrosting can be produced in large amounts. Condensation water must be led off to a drain or similar. Care must be exercised so that the heat pump is not scratched during installation. 14 NIBE F2040

INSTALLATION Pipe installation Pipe installation must be carried out in accordance with current norms and directives. F2040 can only operate up to a return temperature of about 55 C and an outgoing temperature of about 58 C from the heat pump. Because F2040 is not equipped with shut off valves these must be installed outside the heat pump to facilitate any future servicing. Pipe connection (heating medium) F2040 can be connected to the heating system see the section "Docking" or according to one of the system solutions that can be downloaded from NIBE s website www.nibe.se/docking. The heat pump must be vented by the upper connection (QM20) using the venting nipple on the enclosed flexible hose. The supplied particle filter must be installed before the inlet, i.e. the lower connection (XL2, HM in) on F2040. All outdoor pipes must be thermally insulated with at least 19 mm thick pipe insulation. The charge pump must be operational, even if F2040 is not running, to prevent damage due to freezing. Shutoff and drain valves are fitted so that F2040 can be emptied in the event of prolonged power failures. Condensation water collection The integrated condensation water trough is used to collect and lead away most of the condensation water from the heat pump. The condensation water (up to 50 litres/24 hrs) collected in the trough should be routed via a pipe (KVR 10 F2040) to an appropriate drain, it is recommended that the shortest outdoor stretch possible is used. The KVR 10 F2040 accessory should be used to guarantee function. The part of the pipe (KVR 10 F2040) that is not frost protected must be heated by the heating cable to prevent freezing. Route the pipe (KVR 10 F2040) downward from F2040. The drain of the condensation water pipe must be positioned at frost free depth or indoors (subject to local rules and regulations). The installation must be equipped with a water seal where air circulation can occur in the condensation water pipe. Recommended alternatives Condensation water pipe KVR 10 (accessory) Stone caisson If the house has a cellar the stone caisson must be positioned so that condensation water does not affect the house. Otherwise the stone caisson can be positioned directly under the heat pump. The outlet of the condensation water pipe must be at frost free depth. Tryckfall (kpa) 30 25 Pressure drop F2040 F2040 F2040-8/F2040-12 F2040-16 F2040-8, F2040-12 20 F2040-16 15 Frost Frostfritt free djup depth 10 5 Flow 0 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 Flöde l/s NIBE F2040 15

INSTALLATION Recommended alternatives Drain indoors Condensation water is routed to an indoor drain (subject to local rules and regulations). Route the pipe downward from F2040. The condensation water pipe must have a water seal to prevent air circulation in the pipe. Gutter drainage The outlet of the condensation water pipe must be at frost free depth. Route the pipe downward from F2040. The condensation water pipe must have a water seal to prevent air circulation in the pipe. Joint Water seal Frost Frostfritt free djup depth Water seal 16 NIBE F2040

INSTALLATION Electrical installation Incoming feed cable (W1) is supplied and factory connected to terminal block (X1). Approx.1.8 m cable is accessible outside the heat pump. Connect communication cable (W2) (provided by installer) to terminal block (AA23-X4). For connection of accessory KVR 10, heating cable (EB14) is connected via cable grommet (UB3). F2040 does not include a circuit breaker on the incoming power supply. The heat pump s supply cable must be connected to a circuit-breaker with at least a 3 mm breaking gap. When the building is equipped with an earth-fault breaker the heat pump should be equipped with a separate one. Incoming supply must be 230 V 50Hz via distribution boards with fuses. NOTE! The electrical installation and service must be carried out under the supervision of a qualified electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. Incoming supply W1 NIBE F2040 17

TECHNICAL SPECIFICATIONS IP 24 Air-water heat pump F2040-8 F2040-12 F2040-16 Heating Outd. temp: / Supply temp. Output data according to EN14511 ΔT5K Rated output / Supplied output / COP (kw/kw/-) Nominal Nominal Nominal 7/35 C (floor) 3,85/0,84/4,60 5,12/1,08/4,74 7,22/1,55/4,66 2/35 C (floor) 6,03/1,59/3,79 6,77/1,74/3,89 9,58/2,53/3,78-7/35 C (floor) 5,91/2,08/2,84 7,95/2,69/2,96 10,79/3,76/2,87 2/55 C 4,35/2,03/2,14 5,88/2,69/2,19 7,35/3,73/1,97 7/45 C 3,58/1,03/3,47 4,99/1,36/3,66 6,64/1,85/3,59 2/45 C 5,11/1,81/2,82 6,47/2,20/2,94 9,02/3,17/2,84-7/45 C 5,61/2,27/2,47 7,78/3,14/2,48 10,98/4,52/2,43-15/45 C 4,99/2,56/1,95 7,83/4,03/1,94 9,25/4,89/1,89 7/55 C 3,46/1,11/3,11 4,71/1,52/3,10 5,97/2,05/2,91-7/55 C 4,58/2,36/1,94 6,02/2,98/2,02 8,06/4,05/1,99 Cooling Outd. temp: / Supply temp. Output data according to EN14511 ΔT5K Specified/supplied power/eer Max Max Max 27/7 C 7,52/2,37/3,17 9,87/3,16/3,13 13,30/3,99/3,33 27/18 C 11,20/3,20/3,50 11,70/3,32/3,52 17,70/4,52/3,91 35/7 C 7,10/2,65/2,68 9,45/3,41/2,77 13,04/4,53/2,88 35/18 C 9,19/2,98/3,08 11,20/3,58/3,12 15,70/5,04/3,12 Electrical data Rated voltage 230V 50 Hz, 230V 2AC 50Hz Max operating current, heat pump A rms 16 23 25 Max operating current, compressor A rms 15 22 24 Start current A rms 5 5 5 Max permitted impedance at connection point 1) Ohm - - - Nominal output, fan (low/high) W 86 86 2 x 86 Fuse 2) A rms 16 25 25 Refrigerant circuit Type of refrigerant R410A Type of compressor Twin Rotary Compressor oil M-MA68 Volume kg 2,55 2,9 4,0 Cut-out value pressostat HP MPa (bar) 4,15 (41,5) Cut-out value pressostat LP MPa (bar) 0,079 (0,79) Brine Airflow m 3 /h 3000 4380 6000 Max/Min air temp C -20/43 Defrosting system reverse cycle

Heating medium Min/Max system pressure heating medium MPa (bar) 0,05/0,25 (0,5/2,5) Min volume, climate system, heating/cooling l 50 80 150 Min volume, climate system, under floor cooling l 80 100 150 Max flow, climate system l/s 0,38 0,57 0,79 Min flow, climate system, at 100% circulation pump l/s 0,19 0,29 0,39 speed (defrosting flow) Min flow, heating l/s 0,12 0,15 0,25 Min flow, cooling l/s 0,15 0,20 0,32 Max/Min heating medium temp continuous operation C 58/25 Connection heating medium male thread G1 Air-water heat pump F2040-8 F2040-12 F2040-16 Dimensions and weight Width mm 1035 1145 1145 Depth mm 422 452 452 Height with stand mm 895 (+50/-0) 995 (+50/-0) 1450 (+50/-0) Weight (excl. packaging) kg 90 105 135 Other information Enclosure class IP 24 Colour dark grey We reserve the right to make changes in design and dimensions without prior notice. 1) Max. permitted impedance in the mains connected point in accordance with EN 61000-3-11. Start currents can cause short voltage dips that could affect other equipment in unfavourable conditions. If the impedance in the mains connection point is higher than that stated it is possible that interference will occur. If the impedance in the mains connection point is higher than that stated check with the power supplier before purchasing the equipment. 2) Specified output is limited with lower fusing. We reserve the right to make changes in design and dimensions without prior notice. NIBE F2040 19

Vattentemperatur ( C) TECHNICAL SPECIFICATIONS 65 Working range, compressor operation - heating Vattentemperatur Water temperature ( C) 60 58 55 65 50 60 45 55 40 50 35 45 30 40 25 35 20 30 15 25-30 -20-10 0 10 20 30 40 50 58 20 Flow temperature Return temperature 25 43 Utomhustemperatur ( C) 15-30 -20-10 0 10 20 30 40 50 25 43 Utomhustemperatur ( C) Outdoor air temperature C Working range, compressor operation - cooling Vattentemperatur Water temperature ( C) 35 Vattentemperatur ( C) 30 35 25 30 20 25 15 12 20 10 7 15 5 12 10 0 10 15 20 25 30 35 40 43 45 50 5 7 Flow temperature Return temperature Utomhustemperatur ( C) Outdoor air temperature C 0 10 15 20 25 30 35 40 43 45 50 Utomhustemperatur ( C)

APH APH ACCESSORIES VVM 310 Flexible indoor module with system for F2030, F2040 and F2300 VVM 320 Flexible indoor module with system for F2030-7/F2030-9 F2040-8/F2040-12 VVM 500 Flexible indoor module with system for F2030, F2040 and F2300 VPA Double-jacketed hot water cylinder VPA 300/200 VPA 450/300 VPAS 300/450 VPB Water heater with charge coil VPB 500 VPB 750-2 VPB 1000 VPB 200 VPB 300 VPBS 300 Water heater with charge coil KVR 10 F2040 Condensation water pipe, different lengths. Earth circuit breaker 1-phase. KVR 10-10 F2040, 1 m KVR 10-30 F2040, 2.5 m KVR 10-60 F2040, 5 m Ground stand F2040 F2040-8 F2040-12/-16 Wall mounting F2040 F2040-8/-12 SMO20 Control module SMO40 Control module NIBE F2040 21

MILJÖMÄRKT 307 005 NIBE is ISO-certified: SS-EN ISO 9001:2000 SS-EN ISO 14001:2004 This brochure is a publication from NIBE. All product illustrations, facts and specifications are based on current information at the time of the publication s approval. NIBE makes reservations for any factual or printing errors in this brochure. Photos: www.benfoto.se. NIBE 2014. NIBE Energy Systems AB Box 14 285 21 Markaryd SWEDEN Tel. +46 433-73 000 www.nibe.eu 639582 Technical PBD GB NIBE F2040 1409-1