Construction. Pile Restoration Timber/Concrete Pile Repair



Similar documents
WATERPROOFING SikaFuko INJECTION HOSE SYSTEMS UNIQUE WATERPROOFING SOLUTIONS FOR CONSTRUCTION JOINTS

FX-70 Structural Repair and Protection System

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Concrete Repair. Applications and Procedures

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

GARDEN CITY SKYWAY SUBSTRUCTURE REHABILITATION

Sika FerroGard The Unique Multi-Functional Surface Applied Corrosion Inhibitor for Reinforced Concrete. Innovation & Consistency.

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

Construction Products and Systems from Roof to Floor

Preservation, Repair and Rehabilitation of Concrete Bridges, Pavements and Tunnels in Virginia

How To Repair A Steel Pier With A Watertight Frame

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

The AQUAFIN Approach to Concrete Repair

SECTION CAST-IN-PLACE CONCRETE

Construction. Technology and Concepts for the Repair and Protection of Reinforced Concrete

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

MEMORANDUM West Swann Avenue, Suite 225 Tampa, Florida Phone (813) Fax (813)

Strengthening and Repair of Reinforced Concrete Structures. Ian Wienholt Business Development Manager

Causes and Repair Method

Shear Strengthening. Sika CarboDur Composite Systems

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

CRACK and JOINT REPAIRS on INDUSTRIAL CONCRETE FLOORS, PAVEMENTS and SECONDARY CONTAINMENT AREAS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

APE T CFRP Aslan 500

Embedded Parts Introduction - Anchors

Wecryl Waterproofing System under surfacing supplied by others

PC-Concrete Injectable Concrete Anchoring and Repair System

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

TECHNICAL REQUIREMENTS AND SPECIFICATIONS

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

Concrete Repair. Solutions that Challenge Corrosion

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

The Concrete Life Cycle: Maintain to Sustain. Fred Goodwin BASF Construction Chemicals (EB-N) Beachwood OH

Fosroc Construction Grouting Solutions. constructive solutions

Condition assessment and repair of antenna towers concrete foundations

UNIVERSITY OF CHICAGO ELEVATOR PIT LEAK REPAIR

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

Failing Coastal Wood Infrastructure on the Great Lakes

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

BRIDGE REHABILITATION. Maintaining and Repairing Existing Structures

Rudder Repair and refinish

SECTION STORM DRAINAGE SYSTEM

Dowel-Bar Retrofit Using Polyester Polymer Concrete

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

CA-48 TECHNICAL SPECIFICATION

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

Rehabilitation of an Aging Concrete Reservoir Adit Tower

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

THORO. Waterproofing Systems

Waterproofing construction Joints

Epoxy Crack Injection (the basics)

Document Library TS Data Sheet

ICS: Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)

THERMOSET EPOXY POLYMER CONCRETE FOR THE FABRICATION OF CHEMICAL CONTAINMENT VESSELS.

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Tecnoepo Flooring System 185

Specification for Pipe Coating Repairs Offshore

Bonding Agents: The Good, the Bad, and What Works. Bond with Your Concrete

Concrete Waterproofing Systems. Integral Protection.

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Concrete Repair and Protection

SECTION 18 - CAST IN PLACE HIGH PERFORMANCE CONCRETE (HPC)

WATERPROOFING OF WET ROOMS

Concrete Specification for Cooling Tower and Basin

Crevice Corrosion on Stainless Steel Propeller Shafts

High Performance PSA in Sheet Membrane in Water Protection

BRIDGE REHABILITATION TECHNIQUES

MAPEI s Resfoam polyurethane products

Structural Retrofitting Process and Techniques

SikaBond Adhesive Systems for Floor Coverings. Innovation & Consistency. since 1910

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Installation (Figure 1) (Figure 4) (Figure 5) (Figure 2) (Figure 3) (Figure 6)

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Pipe Repair Strategies on I-29

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Joint Rehabilitation. Driving Forces for Concrete Pavement Joint Repairs

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

orizontal BarrierS PATENTED SYSTEM

SPRAY FOAM INSULATION AND COASTAL FLOODING

Construction. Structural Strengthening with SikaWrap Fabric Systems

CAUSES, EVALUATION AND REPAIR OF CRACKS IN CONCRETE

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Fire Damage Evaluation. Concrete Garage. Vehicular fires in parking garages are not an

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

Mold Preventing I nterior System

Underwater Bridge Repair, Rehabilitation, and Countermeasures

Transcription:

Construction Pile Restoration Timber/Concrete Pile Repair

s Methods/ Products that Comprise Sika Pile Restoration Systems Scenario 1 Dry (Over Land) Symptoms Decayed Core, Fungal Attack (Outer Layer Intact) Preparation of Timber Substrate Base Material Drill holes (3 diam.) through outer layer to penetrate damaged core. Mechanical removal of loose core material by way of vacuuming, flushing, sawing or other approved means. Allow sound timber to drain and dry. Treat core with anti-fungal solution and/or rods (e.g. Borate). Depending on size of cavities and voids in core, place appropriate sized aggregate as filler material. Plug holes with treated timber dowels. Mechanical removal of all surface contamination such as grease, oil, tar, etc. by way of sand blasting, hydro-blasting, wire brushing or other approved means until a clean sound substrate is achieved. REPAIR PRODUCTS Sikadur 35, Hi-Mod LV Injectable, high modulus, low viscosity, epoxy resin to fill finer cracks. Sikadur Injection Gel (optional) Injectable, high modulus, epoxy resin paste to seal and repair surface, mount injection ports, pump or tool into larger cavities and voids. Sikadur 300 High modulus, high strength, impregnating epoxy resin for wet lay-up fiberglass wrap application. SikaWrap 100G Heavy duty, fiberglass wrap fabric for structural strengthening. [Other fiberglass and carbon fiber fabric options to choose from depending on performance requirements.] Sikagard 670W Acrylic, UV resistant protective anti-carbonation coating for repaired pile exterior. Advantages Restore structural integrity of severely decayed timber piles. Epoxy injected into aggregate-filled core develops high compressive strengths to bear loads. Compressive strengths effectively increased by 85% after transverse fiberglass reinforcement applied to provide material confinement. Average compressive strengths of repaired piles exceed published values of common wood species typically used for timber piles. Sikagard 670W Protective Acrylic Coating (Pigmented) SikaWrap 100G Structural Strengthening Fabric Sikadur 300 Drilled Hole For Filler Aggregate Placement (Later Plugged with Timber Dowel) Drilled Hole For Filler Aggregate Placement (Later Plugged with Timber Dowel) Sikadur 300 SikaWrap 100G Structural Strengthening Fabric Sikagard 670W Protective Acrylic Coating (Pigmented) Injection Port Sikadur Injection Gel (Optional for Pile Surface Repair) Sikadur Injection Gel (Optional for Pile Surface Repair) Sikadur 35, HI-MOD LV Injected Into Filler Aggregate Removed Port (After Epoxy Injection) Drilled Hole (For Epoxy Injection) Sikadur 35, HI-MOD LV Injected Into Filler Aggregate DRY (OVER LAND)

s Scenario 2 Wet (Submerged Marine Environment) Symptoms Marine Borer Infestation, Rot Decay in Tidal Zones, Hour-Glass Deterioration Preparation of Timber Substrate Base Material Mechanical removal of loose material and all surface contamination such as grease, oil, tar, marine organisms, etc. by way of hydro-blasting, sawing, wire brushing and other approved means until a clean, sound timber substrate is achieved. REPAIR PRODUCTS Fiberglass Reinforced Plastic (FRP) Pile Repair Sleeves One-piece sleeve used to contain pumped epoxy mortar around damaged timber pile. Easy to install, typical tongue and groove repair sleeves help divers quickly assemble around pile prior to grouting. Sikadur 35, Hi-Mod LV LPL Mix with specified aggregate to make a high modulus, high strength, low viscosity epoxy mortar with extended pot life for effective pumping to repair location. [Contact Sika Technical Service Department for more information: 1-800-933-SIKA] Sikadur Pump-Aid (optional) Additive to aid equipment s ability to pump when job site conditions prevent proper conditioning (65 75 F) of Sikadur 35, Hi-Mod LV LPL before mixing epoxy mortar. [Contact Sika for Technical Data Sheet.] Sikadur AnchorFix-3/Sikadur AnchorFix-4 (optional) Fast setting / regular setting versions of Sikadur Injection Gel packaged in convenient, easy to dispense, cartridges. Three cartridge sizes to choose from (8.5, 22 and 55 fl. oz.). Adhesive components mix when dispensed through static mixing nozzles. Sika CarboDur Rods (optional) Supplement pile repair with increased flexural strength (as much as 50 to 100%) by encapsulating carbon fiber reinforcing rods within the epoxy mortar or embedding into the timber pile. Available in 1/4" and 3/8 diameters and custom lengths. Advantages Provides a hard shell barrier protecting wood against intrusion of marine organisms. Provides a nearly no-maintenance method to prevent future deterioration. Significant cost savings in lieu of conventional timber replacement. Lightweight, space and labor saving option to concrete repair methods. Typical 9,000 psi compressive strength of Sikadur 35, Hi-Mod LV LPL epoxy mortar. Use of optional Sika CarboDur rods effectively increases typical flexural strength of repair by 53%. Decayed Repaired Pile with Epoxy Mortar Sikadur 35, HI-Mod LV LPL Epoxy Mortar FRP Pile Repair Sleeve Adjustable Stand-off To Provide Annulus Sika CarboDur Rod (Optional - within Epoxy Mortar) Sika CarboDur Rod (Optional - Slotted into Pile Surface) Sikadur 35, HI-Mod LV LPL Epoxy Mortar FRP Pile Repair Sleeve Injection Port Hour-Glass Effect Epoxy Mortar Flows Into Damaged Portion. Removed Port (After Epoxy Injection) CarboDur Rod (Optional - Slotted into Pile Surface) CarboDur Rod (Optional - Within Epoxy Mortar) WET (SUBMERGED MARINE ENVIRONMENT)

Concrete Piles Methods/ Products that Comprise Sika Pile Restoration Systems Scenario 3 Wet (Marine Environment) Symptoms Spalling, Corrosion of Reinforcement Preparation of Concrete Substrate Base Material Mechanical removal of loose material and all surface contamination such as laitance, grease, oil, tar, etc. by way of shot blasting, scarifying, sand blasting, hydro-blasting, grinding, wire brushing or other approved means until a clean, sound concrete substrate is achieved. REPAIR PRODUCTS Fiberglass Reinforced Plastic (FRP) Pile Repair Sleeves One-piece sleeve used to contain pumped or poured epoxy mortar or cementitious grout around damaged concrete pile. Easy to install, typical tongue and groove repair sleeves assemble quickly around pile prior to grouting. Sika MonoTop 611 High, early strength, single component, polymer-modified, silica fume enhanced cementitious mortar for effective pumping to repair location. Sikament 100 SC For underwater placement, anti-washout admixture for Sika MonoTop 611 to produce grout that is fluid and highly resistant to dilution and segregation. [Contact Sika Technical Service Department for more information: 1-800-933-SIKA] Sika FerroGard 901 A liquid concrete admixture formulated to protect embedded reinforcing steel from corrosion and to provide means for extending the service life of concrete structures. Sika Galvashield Anodes (optional) Innovative, long-lasting, sacrificial, zinc anodes activated by the surrounding Sika MonoTop 611 cementitious mortar. Quickly and easily fastened to exposed steel reinforcement, used to control ongoing corrosion and prevent the initiation of new corrosion activity. Sikadur Injection Gel High modulus, high strength epoxy resin paste used to seal foam gaskets and seams of FRP Pile Repair Sleeves. Also use to seal and repair concrete surfaces, pump or tool into larger cavities and voids. Advantages Pump Sika MonoTop 611+ Sikament 100 SC through smaller diameter hoses than standard concrete pumping procedures allow. Increases versatility of mortar placement allowing greater access to smaller voids. Sika MonoTop 611+ Sikament 100 SC drives out water and bonds well to prepared concrete substrate. Cost effective alternative to conventional concrete removal and replacement methods. Optional corrosion protection and prevention methods significantly extend expected service life of repair. Repair Mortar with Anti-Wash-Out Admixture Hardened repair material, underwater. Cross Section of Repaired Pile. Repair Material Thickness = 1.5-2 FRP Pile Repair Sleeve Concrete Pile Affinity of Corrosion Inhibitors Protects steel Sika Monotop 611 and Sikament 100 SC to Prevent Washout During Submerged Placement Steel Reinforcing Bar Adjustable Stand-off To Provide Annulus FRP Mesh (Optional) Concrete Pile Sika MonoTop 611 and Sikament 100 SC FRP Pile Repair Sleeve Sika Galvashield Optional - Custom Anode Strips Wired to Steel Reinforcement Steel Reinforcement With Corrosion Attack Sika FerroGard 901 (Optional) Sika MonoTop 611 and Sikament 100 SC Flows Into Damaged Portion & Around Steel Reinforcement Bars Injection Port Steel Reinforcing Bar FRP Mesh (Optional - Line inside of FRP Pile Repair Sleeve) Sika Galvashield Custom Anode (Optional - Attach to Steel Reinforcement prior to grout) WET (MARINE ENVIRONMENT)

Pile Restoration Sika Repair Solutions Pile supported structures are commonplace throughout the world. Whether supported by timber, concrete or steel piles, structures incorporating these methods of elevation and support define thousands of miles of the world s coastlines and are major components of bridges over both land and sea. Structures supported by piles built along waterfronts, providing modes of transportation and trade, play a vital role in the world s economy. Historically, the lack of monitoring and regular maintenance are the primary reasons for structural piles falling into a state of disrepair. Traditional methods of repair vary for piers where deterioration of aging pile supports has occurred. Complete removal and replacement methods, heavy encapsulation with new concrete and supplementation of existing piles with additional piles typically prove to be a costly repair no matter what the structure type or prevailing environmental conditions may be. In cases of timber pile applications over land, significant damage due to dry rot, termite infestation and / or fungal decay of the wood are the primary concerns. Wood preservative treatments tend to penetrate into only the outer layer of large timbers. Over time as large timbers dry, the wood tends to shrink. Internal shrinkage causes voids, which provide a pathway for fungi to enter the untreated portion of the timber and cause decay within the core, creating a virtual hollow shell. Timber piles that support piers over water suffer damage for different reasons. Floating debris, freeze-thaw cycles, adverse effects of pollution, saltwater, fuels, chemicals and collisions with sea-faring vessels contribute to the need for improvement. Rot decay in tidal zones is common. Environmental efforts to improve the quality of waterways have resulted in a proliferation of living organisms known as marine borers (i.e. limnoria, teredo), which thrive on the wood and have a detrimental effect on the piles load capacities. Concrete piles present challenges typical of where Sika s expertise in repair and protection lies. Deterioration due to moisture, chemical and chloride intrusion causing the corrosion of reinforcing steel are documented problems of the industry. Changes in the end use of the supported piers may require the supporting concrete piles to be strengthened. Sika, in cooperation with other suppliers, now offers systems and solutions for the repair of damaged piles. Fiberglass Reinforced Plastic (FRP) Pile Repair Sleeves wrap around the pile and contain various grouting material options manufactured and supplied by Sika. In situations where corrosion of steel reinforcement in concrete piles needs to be addressed, Sika offers Total Corrosion Management Solutions, including consultation, services, and products. Extensive testing, field experience and high quality control in the manufacturing of products fully support all components of the Pile Repair concept. Ultimately, the long-term solutions to your Pile Restoration projects are now available through Sika!

1-800-933-SIKA Nationwide www.sikaconstruction.com Sika. One Name. One Source. Worldwide. Sika Corporation (USA) 201 Polito Avenue Lyndhurst, NJ 07071 Phone: 201-933-8800 Fax: 201-933-6225 Sika Mexicana S.A. de C. V. Carretera Libre Celaya Km. 8.5 Corregidora, Queretaro C.P 76920 A.P. 136 Phone: 52 42 25 0122 Fax: 52 42 25 0537 Sika Canada, Inc. 601 Delmar Avenue Point Claire, Quebec H9R4A9 Phone: 514-697-2610 Fax: 514-694-2792