A Single Source for all Power System Solutions



Similar documents
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Spark-ignited generator set

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DFMB 60 Hz

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Diesel Generating Set

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Technical Specification. Generating Set with Waukesha engine burning natural gas

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Diesel Engine Driven Generators Page 1 of 6

DIESEL GENERATOR SETS

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Annex-A TECHNICAL SPECIFICATION

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

How To Control A Power Command Powerplant

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

PM734F - Technical Data Sheet Winding 28

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

BCI184E - Technical Data Sheet

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

Marine Generating Sets 3.7 to 50 kva

Diesel Generator Set Model DGDK 60 Hz

Magnum Mobile Generator MMG55 Specifications

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

GTEC transfer switch open transition

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

APS100 Rental Generator Set Specification

C18 ACERT Fire Pump Tier bkw/ rpm

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

How To Use A Cat Diesel Engine

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Diesel generator set C22D5T series

Atlas Copco Generators

Digital generator set 1302 control kit

Generators TEM. for small hydroelectric power stations. Electric Machines

Power Generation. Power Control PCL System Generator Set Control

CUKUROVA GENERATOR SYSTEMS

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

PowerCommand 1.1 control system

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

PowerCommand Paralleling System Digital MasterControl

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

C18 Diesel Oilfield Generator Set

3516 Industrial Engine

CUKUROVA GENERATOR SYSTEMS

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Process Alarm Solutions

ECOCIAT. Domestic hot water heat recovery unit

The Yachtmans Choice...

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Single-Phase AC Synchronous Generator

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Oil and Coolant Circulating Heating System. Model - OCSM

STAMFORD Product Guide

Turbo generators Best quality for thermal power plants

IGSA POWER GENERATION SYSTEMS

Power Plant Electrical Distribution Systems

SELECTION, APPLICATION AND MAINTENANCE

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

The reliability of the grid

Unified requirements for systems with voltages above 1 kv up to 15 kv

Power Meter Series 700

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

X G R E N T A L

Transcription:

Power Generation Gas Engine Powered Generating Sets 1540-1750 kwe 50 Hz 1250-1760 kwe 60 Hz QSV91G Series Engines Standard Genset Features Single Source Responsibility Design, manufacture and testing of engine, alternator, control system and complete generating set are all produced by companies within the Cummins Group International Integrity Assurance and strength of a worldwide major corporation backing the product Global Backing 24 hour spares and service availability in 72 countries Single Source Warranty Total product guaranteed by Cummins Power Generation Packaged Units Integrated unit with control panel, starting system and other accessories Cummins Engine Heavy duty 4 cycle water cooled engine MCM700/SSM558 full authority electronic management Woodward PROACT actuator to drive throttle valve CENSE engine monitoring system Ready Filled Every set comes filled with lube oil Brushless, self-exciting machine Close voltage regulation Rotor and exciter impregnated with oil and acid resisting resin 12 lead reconnectable Exceptional short circuit capability Low waveform distortion with non linear loads Ratings All kw Power ratings based on a 35 C ambient temperature reference. Refer to factory for deration for temperatures above 35 C and for operation in island mode. Control System PCS PowerCommand Supervisor Microprocessor control Integrated voltage regulation Superior alternator and genset protection system Totally reliable and proven system HMI (touch screen) PLC BSI RE GIST E R E D FIR M NATIONAL ACCREDITATION OF CERTIFICATION BODIES Quality Assurance Registered Firm Certificate Number FM509 in accordance with: BS EN ISO 9001 Quality Assurance Schedule 3420/1 Engine One Source Generating One Name Set Controls Cummins Power Generation, Cummins Engines and Newage s are all part of the same group Ratings Model 50 Hz 1500 rpm 14 bar(g) Model 60 Hz 1200 rpm 14 bar(g) kwe kva @ 0.8pf kwe kva @ 0.8pf QSV91-G 1540 1925 QSV91-G 1250 1562 50 Hz 1500 rpm 16 bar(g) 60 Hz 1800 rpm 16 bar(g) QSV91-G 1750 2187 QSV91-G 1760 2200 A Single Source for all Power System Solutions

Specifications Generator Set Performance Voltage Regulation Maintains voltage output to within 1.0%. At any power factor between 0.8 lagging and unity. At any variations from No load to Full load. At any variations from Cold to Hot. At speed droop variations up to 4.5%. Frequency Regulation Isochronous under varying loads from no load to 100% full load. Random Frequency Variation Will not exceed 0.25% of its mean value for constant loads no load to full load. Waveform Total harmonic distortion open circuit voltage waveform in the order of 1.5%. Three-phase balanced load in the order of 5.0%. Telephone Influence Factor (TIF) TIF better than 50. THF to BS4999 Part 40 better than 2%. Temperature Rise Class H insulation. Temperature rise up to 125 C permitted (low voltage only). Radio Interference In compliance with BS800 and VDE levels G and N. Engine Cummins QSV91G spark ignited lean burn gas combustion engines. 18-cylinder, V form. Type Water cooled, four cycle, turbo charged and aftercooled. Construction Four valves per cylinder, forged steel crankshaft and connecting rods, cast iron block, replaceable wet liners. Fuel System Safety shutdown solenoid valve, pressure regulator valve, manual shut-off valve, dust filter. Flexible fuel line. Control Fully integrated controls and monitoring including fuel system, ignition system and governing. MCM700 provides engine protection, control and governing. SSM558 caters for fuel and ignition protection and control. CENSE provides detailed engine monitoring. Filters Dry element air filters with restriction indicator. Spin-on full flow paper element combination lube oil filters fitted. Spin-on corrosion resistor filter. Starting Pneumatic start system through single air starter motor. Ignition Individual coil on plug arrangement. Cooling Separate LT and HT cooling circuits. Coolant heater, water circulating pump and thermostat. Engine driven water pumps. Type Brushless, two bearing, revolving field, 4-pole, drip proof, screen protected. Class H insulation (LV), Class F insulation (MV & HV). Enclosed to minimum IP22 as standard. IC 01 cooling system. Fully interconnected damper winding. AC exciter and rotating rectifier unit. Epoxy coated stator winding. Rotor and exciter impregnated with tropical grade insulating oil and acid resisting polyester resin. Dynamically balanced rotor to BS5625 grade 2.5. Sealed for life bearings. Layer wound mechanically wedged rotor. Exciter Triple dipped in moisture, oil and acid resisting polyester varnish and coated with anti-tracking varnish. PMG self-exciting. Output windings with 2/3 pitch for improved harmonics and paralleling ability. Engine and alternator coupled via a flexible coupling. Chassis Fabricated and welded steel chassis Spring anti-vibration mountings supplied loose Finish Etch undercoated and finished in high gloss durable green General Complete set of operating and instruction manuals Testing Fully tested against a resistive load. Copy of test certificate provided. Compliance Standards To BS4999/5000 pt 99, VDE 0530, UTE5100, NEMA MG1-22, CEMA, IEC 34, CSA A22.2, AS1359, BSS5514, ISO 3046 and ISO 8528

Control System GCP System Configuration Fully Integrated System PC based HMI (touchscreen) PowerCommand Supervisor PLC based auxiliary control A.C. auxiliaries enclosure D.C. engine interface enclosure Stand-alone or Parallel Operation Single or multi-set isolated bus operation Single set base load utility paralleling Isolated bus paralleling control Base load utility paralleling control Plant Screens H.M.I. (Touchscreen) Micro-processor based graphic interface (touchscreen) Layered menus for ease of operation System Screen Other Screens Systems Data (restricted access) Engineers Data (restricted access) all MCM700 data Fault Management Screens reports and logs faults summary/historical data real time recording of faults Plant status Electrical data Mechanical data Test Access to other screens

Control System PowerCommand Supervisor Control with AmpSentry Protection Integrated automatic voltage regulator. Speed/load bias to MCM700 AmpSentry Protection guards the electrical integrity of the alternator and power system from the effects of overcurrent, over/under voltage, under frequency and overload conditions Control components designed to withstand the vibration levels typical in generator sets Standard Control Description Analog % of current meter (amps) Analog AC frequency meter Analog AC voltage meter Analog % of load meter (kw) Digital display panel Emergency stop switch Menu switch Panel backlighting Reset switch Run-Off-Auto switch Sealed front panel, gasketed door Self diagnostics Separate customer interconnection box Voltmeter/Ammeter phase selector switch PCS PowerCommand Supervisor standard configuration Standard Performance Data AC Data Current by Phase Kilowatts Kilowatt Hours Power Factor Voltage Line to Line Voltage Line to Neutral Engine Data Battery Voltage (for electric start option) Coolant Temperature Engine Running Hours Engine Starts counter Oil Pressure RPM Oil Temperature EMC Compliance The PCS control system meets EMC Shield Regulations. Standard Protection Functions Warnings Analogue Sender Failure High DC Voltage EEPROM Failure Low DC Voltage Over Current Phase Rotation CB Fail to Close Live Bus Up to Four Customer Fault Inputs Weak Battery (electric start option) Shutdowns EEPROM Failure Loss of Excitation Reverse Power Fail to Synchronise Magnetic Pickup Failure Underfrequency Overcurrent Overspeed Short Circuit Low AC Voltage High/Low AC Voltage Voltage Regulation 0.5% with PowerCommand fitted. PLC Auxiliary Control Communication handling procedures Protocol interfaces Control of plant auxiliaries AC Auxiliaries Enclosure Incoming auxiliary a.c. supply for set Control/monitors/protects generator set a.c. systems not located in the GCP DC Engine Interface Enclosure Interfaces between GCP and genset Other Items Battery charger and batteries for GCP

Technical Data Units 50 Hz 50 Hz 60 Hz 60 Hz Generator Set Data via gearbox Model QSV91-G QSV91-G QSV91-G QSV91-G Generator electrical output kwe 1540 1750 1250 1760 voltage regulation +/-1% +/-1% +/-1% +/-1% protection class IP22 IP23 IP22 IP22 insulation/temperature rise H/H H/H H/H H/H Heat radiated to ambient kw 199 224 159 227 Starting air bottle recommended pressure bar (G) 30-40 30-40 30-40 30-40 Electric starter voltage V 24 24 24 24 Minimum battery capacity @ 20 C Ah 720 720 720 720 Engine Data Engine Model QSV91-G QSV91-G QSV91-G QSV91-G Bore mm 180 180 180 180 Stroke mm 200 200 200 200 Capacity litres 91.62 91.62 91.62 91.62 Configuration 18 V 18 V 18 V 18 V Aspiration TCA TCA TCA TCA Engine speed rpm 1500 1500 1200 1500 (1800) Compression ratio 12:1 12:1 12:1 12:1 BMEP bar (G) 14 16 14 16 Effective mechanical output with engine driven pumps kw 1600 1832 1280 1860 Energy input LHV kw 4161 4677 3317 4746 Electrical efficiency % 37.0 37.4 37.6 37.0 Mechanical efficiency % 38.4 39.1 38.5 39.1 Minimum Methane Number 70 77 70 77 Gas supply pressure range bar (G) 0.25 to 3.0 0.25 to 3.0 0.25 to 3.0 0.25 to 3.0 Total heat rejected to LT Circuit kw 366 406 310 446 Total heat rejected to HT Circuit kw 612 698 583 709 Heat rejected to exhaust to 105 C kw 1056 1167 807 1183 Aspiration air flow kg/s 2.37 TBA 1.89 TBA Exhaust gas flow rate kg/s 2.45 2.77 1.96 2.81 Exhaust gas temperature after turbine C 508 499 490 498 Maximum exhaust system back pressure mmwg 500 500 500 500 LT Circuit water flow rate cu.m/h 38 38 38 38 Maximum LT engine water inlet temperature C 50 50 50 50 LT engine water outlet temperature C 59 59 59 59 LT Circuit maximum pressure @ engine bar 4.5 4.5 4.5 4.5 HT Circuit water flow rate cu.m/h 46 60 40 60 HT engine water inlet temperature C 82 82 82 82 HT engine water outlet temperature C 95 95 95 95 HT Circuit maximum pressure @ engine bar 4.5 4.5 4.5 4.5 Minimum static head on LT & HT water cooling circuits bar (G) 0.5 0.5 0.5 0.5 Maximum pressure drop through external cooling circuit bar 1 1 1 1 Lube Oil flow rate l/m 1412 1412 1130 1412 Lube Oil engine inlet temperature C 96 96 96 96 Lube Oil engine outlet temperature C 103 103 103 103 Engine lubricating oil capacity litres 560 560 560 560 Lubricating oil consumption g/kwhm <0.5 <0.5 <0.5 <0.5 COP rating in accordance with ISO 8528 and BS5514 at a maximum aspiration air temperature of 35 C, a maximum altitude of 1000 metres above sea level and with the generator sets operating in parallel with the utility. No overload available. All data based upon engines at 100% full load, having a 12:1 compression ratio, 95 C HT water outlet temperature, 500 mg/nm NOx emissions and for low voltage alternators at 0.8 power factor lag. Energy input in accordance with ISO 3046/1 with natural gas having a LHV of 33.44MJ/Nm3. Heat rejection data subject to a tolerance of +/-5%. For detailed technical data on the various engine versions available refer to the specific data sheet.

Optional Items Generator Set Options Engine Heavy duty air cleaner Sump drain pump Oil and water drain taps Automatic sump oil make-up valve Flexible engine connections CE Compliance (guarding) Exhaust temperature monitoring Tool kit 2/3rds TA Luft 24V electric starting Dual pneumatic/electric starting Air starting module 380-440 V, 3.3 kv, 6.3-6.6 kv, 11 kv-50 Hz 380-690V, 4-16 kv, 13.8 kv-60 Hz Left or right hand cable access 105 C rise alternator (LV machines only, standard on MV and HV) Dimensions and Weights Fuel System Gas flow meter Pressure regulating valves Flexible connecting pipe Cooling 30 C ambient radiator 40 C ambient radiator Heat exchanger cooling (project specific) External electric pumps for engine cooling circuits complete with thermostats (project specific) Heat Recovery Water jacket heat exchangers Exhaust gas heat exchangers Exhaust gas boilers Separate lubricating oil cooling circuit Exhaust System Industrial type silencer Residential type silencer Length of flexible exhaust and bellows Generator Set Weather protecting ISO style containers Silenced ISO style containers, 85 db(a) at 1 metre Miscellaneous Flexible water, oil and air connections Duplex (running change) lubricating oil filters Crankcase breather filter Control Panel 3 or 4 pole circuit breaker (separate enclosures) CE Compliance Remote monitoring capabilities System control (master) panel Optional power cable access either side C O/A A B Dimensions and Weights (mm) Set Weight Set Weight A B C kg Dry kg Wet Without bed mounted radiator 5606 1721 2661 16062 17507 Dimensions and weights are for guidance only. Do not use for installation design. Ask for certified drawings on your specific application. Specifications may change without notice. Power Generation See your distributor for more information. Cummins Power Generation Limited Manston Park, Columbus Avenue Manston, Ramsgate Kent CT12 5BF, UK Telephone: +44 (0)1843 255000 Fax: +44 (0)1843 255902 Email: cpg.uk@cummins.com www.cumminspower.com Standard and custom made generating sets from 30 kva to 2500 kva Cummins is a registered trademark of Cummins Engine Company