Benchtop Series Ultrasonic Cleaning Tanks Operations and Maintenance Instructions



Similar documents
Instruction Manual. SonicMax Ultrasonic Cleaning Systems. Graymills

Ultrasonic support removal tank

Model DH436R-A and DH536R-A Heated, Drum-Mounted Recirculating Parts Cleaner Operations and Maintenance Instructions

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Ceiling Mount Air Handler Manual

Dehumidifier Users manual. For Models: DH45S DH65S

Operators Manual. Integrated Cleaner

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

WARMER or COOKER/WARMER

Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

Instruction Manual. AWK-115S

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

IMPORTANT SAFETY RULES TO FOLLOW

Sip/Puff Switch User Guide

orlando OWNER S MANUAL

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Electric Water Kettle

Hot Water Central. Electric Hot Water Dispenser. Instruction Manual AAP-325W.

Owner s Manual & Safety Instructions

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ClearView 100. Instruction Manual

3 WATT LED SPOTLIGHT Model No. SLM

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

NFC Communication Tray Model: HHX-IT3-Z

Select Radiators Installation Guide

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Customer Support

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

100 Series Maxi Internal Filters. Instruction Manual

tire inflator with pressure gauge

Model 1756 Test Lead Kit

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

Wine Cooler with Thermo-Electric Cooling & Heating Technology

1/3 HP Submersible Sump Pump with Vertical Float Switch

Electric Egg Boiler. Instruction Manual. Model Number: AEB-917

San josé OWNER S MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

Bottom Loading Water Dispenser

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

London Farm Kitchen Sinks

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

Owner s Manual & Safety Instructions

MINI-BRUTE II HOT WATER POWER WASHER MODEL# MBII

Owner s Instruction Manual. 2500/2554 Telephones Message Waiting

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

RX-18B ORDERCODE D3314

UNITOR ULTRASONIC cleaning

Leak Detection System

SYSTEM Inverter Air Conditioners

Deluxe Bottle Warmer

Call us toll free at: GEVALIA ( )

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

Installation and Operating Instructions (for chargers shown below)

A. Work on this project shall consist of, but is not limited to, the following:

Packaged Terminal Air Conditioner Wall Sleeve Installation


Columbia flooring will resist fading from exposure to sunlight or artificial light.

15GAL STEEL OIL DRAIN WITH 110V PUMP

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

Wireless Phone Jack System

PNEUMATIC PLANISHING HAMMER

2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to

Model: Model: Description: Voltage: Amps: Ice Type: Unit Weight:

Electric Water Heater

Installation and Operating Instructions (for chargers shown below)

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

CURL. Have a Question? Call Us First!

Bubble King. User Manual

TOLL FREE: (866) VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09042K1

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Operating and Installation Instructions

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Due to continual improvement in design or otherwise, the product you purchase may differ slightly from the illustrations in this book.

Nest Learning Thermostat Installation Guide. Installation step-by-step

Mini-led spotlight with magnetic base

1 Ton Telescoping Gantry Crane

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Ride-on Car OWNER S MANUAL KT1151TG. Keep instructions for future reference

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

LACAVA. Table of Contents. Owner s Manual. Wall-mounted & Vessel Sinks PS#:

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

Cable Tester Pro ORDERCODE D1909

ROTOR LOADER OWNER S MANUAL


Transcription:

Graymills Benchtop Series Ultrasonic Cleaning Tanks Operations and Maintenance Instructions Be sure anyone operating this unit reads and understands all warnings and instructions. Keep this manual available for reference/training. SAFETY WARNINGS You will find various types of safety information on the following pages and on the labels attached to Graymills equipment. The following Safety Statements explain their meaning: This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid personal injury or death. DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION, without the safety alert symbol, is used to address practices not related to personal injury. READ BEFORE OPERATING Never work with equipment you feel may be unsafe. Contact your supervisor immediately if you feel a piece of equipment is in unsafe condition. Cleaning solutions may be irritating to skin and eyes. Always wear gloves, apron and safety glasses when using. If splashed in eyes, flush thoroughly with water and follow directions on cleaning solution. UNPACKING 1) When the equipment is received, inspect the packaging exterior for shipping damage. 2) Report any visible packaging damage to the freight carrier immediately. 3) Carefully open the packaging and remove any packing material. 4) Remove the equipment from the carton and visually inspect for concealed damage. 5) Report any concealed damage to the freight carrier immediately. Important: All claims for shipping damage must be handled directly with the freight carrier. Do NOT return damaged equipment to Graymills without first obtaining an RMA. Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 1

OPERATION INSTALLATION AND SETUP 1) Choose a well-lit, well-ventilated work area with clear access to the cleaning tank. 2) Place the unit on a level bench or platform capable of supporting the weight of the cleaning tank when filled with fluid and the parts to be cleaned. 3) The bench surface should be resistant to the cleaning fluid used in the cleaner. 4) Be sure that the airflow openings at the bottom of the tank are not blocked. 5) A grounded 115VAC electrical outlet should be located near the cleaning tank. Do NOT use an electrical extension cord to connect the cleaning tank to the power source. It is strongly recommended that the electrical supply outlet be protected by a Ground Fault Circuit Interrupter (GFCI). 6) Provide an area near the cleaning tank for storage of the cleaning fluid used in your application. Refer to the APPLICATIONS section for recommendations on the proper cleaning fluid for your application. This ultrasonic cleaner is intended for use only with non-flammable cleaning fluids compatible with the stainless steel cleaning tank. NEVER use a flammable or combustible fluid in this parts cleaner. Using a flammable or combustible fluid in this equipment may produce a hazardous condition that can result in property damage or injury to personnel. This warning also applies to non-flammable fluids that have become contaminated with flammable or combustible materials. Refer to the APPLICATIONS section for recommendations on the proper cleaning fluid to use for your application. If in doubt, contact the Graymills customer service department at (773) 248-6825 for cleaning fluid recommendations. STARTUP 1) Be sure the ULTRASONIC GENERATOR and HEATER switches are in the OFF position. Check that the drain valve is closed. 2) Fill the tank with the desired non-flammable, non-combustible cleaning fluid. DO NOT OVERFILL. Be sure to leave room above the liquid level to immerse the workload without spilling over the top of the tank. A good policy is to leave a 1½ minimum freeboard between the top of the fluid and the top of the tank with the workload fully immersed. This will reduce the possibility of spillage. 3) Add the required cleaning chemicals to the water in the tank. Consult the cleaning fluid manufacturer s literature and the APPLICATIONS section of this manual to determine the proper amount of detergent to add. The detergent may be pre-mixed with the water before filling the tank if desired. The amount of contaminants on the parts and the quality of the water in your area will affect the amount of detergent concentrate to add. After cleaning a few typical parts, the detergent concentration may be adjusted for best results. 4) Connect the power cord to the power outlet. Never operate the tank heaters or the ultrasonics without at least 6 of liquid in the tank. Operating the ultrasonic cleaner with a dry tank or with insufficient liquid will cause permanent damage to the heaters and/or the ultrasonic transducers. 5) Set the temperature control dial to the desired operating temperature. Consult the cleaning fluid manufacturer s literature and the APPLICATIONS section of this manual for guidance in setting the proper temperature. The optimum cleaning fluid temperature will be between 120º F. and 140º F. 6) Turn on the HEATER switch and allow the cleaning fluid to reach the set temperature. 7) Turn on the ULTRASONIC GENERATOR switch and allow the cleaning fluid to degas for several minutes. Refer to the APPLICATIONS section of this manual for an explanation of the degassing process. PARTS CLEANING 1) Place the contaminated parts in a free-draining basket and lower the workload into the ultrasonic tank. Parts may be suspended in the tank by a hook or cable if that is more convenient. Avoid placing parts directly on the tank bottom. Damage to the parts or the tank bottom may occur. Retrieval of parts after cleaning is simplified if the parts are suspended in the cleaning fluid loaded in baskets or by using a hook. Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 2

2) Refer to the APPLICATIONS section of this manual for guidance as to the required cleaning time for your application. The cleaning time will be determined after cleaning a few trial loads and evaluating the resulting cleanliness level. Typical cleaning times will range from 3 to 6 minutes. Severely contaminated parts may require longer cleaning times. When starting out, NEVER leave parts in the ultrasonic tank unattended longer than 4 or 5 minutes. Painted or polished part surfaces may become damaged by excessive exposure to the ultrasonics. 3) Placing the lid on the tank will reduce any objectionable noise while cleaning parts. This will also reduce heat losses and the discharge of odors and vapors into the work environment. 4) Parts in the basket should be arranged so that the cleaning fluid can flow freely around all surfaces of the work and drain thoroughly after the cleaning process. Avoid over-filling the basket with too many layers of parts. 5) Concave or hollow parts should be placed so that they fill completely while submerged and drain completely after cleaning. Gentle tumbling while submerged or draining can often facilitate this process. RINSING AND DRYING 1) The workload may require rinsing to flush away any contaminants that may re-deposit on the parts as they are withdrawn from the cleaning tank. Also, check cleaning solution instructions to see if they recommend rinsing. The parts may be immersed in a tank of clean water or held under a running water flow to rinse away any loosened debris. A heated rinse may be required to completely remove any remaining detergent residues. 2) If dry parts are required after cleaning, the workload may be blown dry or placed in a heated drying chamber to remove any remaining water. If compressed air is used to blow off the parts, it should be clean, oil-free and filtered to avoid recontaminating the cleaned parts. Follow Safety Instructions for use of compressed air blowing. MAINTENANCE This machine utilizes dangerous high voltage to operate the ultrasonic transducers. Only qualified trained personnel should attempt any repairs or servicing of the ultrasonic components. Disconnect all power before servicing the ultrasonic generators or tank heaters. If in doubt about any servicing procedures, contact Graymills customer service department at (773) 248-6825. Be sure to unplug the power cord and allow the tank to cool for 15 minutes before draining the fluid. Operating the heaters or the ultrasonics with a dry tank or with insufficient fluid level will permanently damage the heaters and/or the ultrasonic transducers. CLEANING TANK The cleaning tank should be cleaned periodically to remove accumulated debris from the sides and bottom. This should be done at least weekly, or more often if soil accumulation is high. 1) Place the HEATER and ULTRASONIC GENERATOR switches in the OFF position. 2) Unplug the power cord from the electrical outlet. 3) Open the drain valve and allow the tank to empty. 4) Using a stiff brush or sponge, wash out the tank interior using a mild detergent solution. Rinse thoroughly and repeat as needed. Avoid the use of abrasive materials such as scouring pads, scouring powder, scraping tools, etc. on the tank interior. Damaging the finish on the tank walls or bottom will shorten the life of the ultrasonic tank and may lead to the development of pinhole leaks over time. 5) Close the drain valve and re-fill the tank with fresh water and cleaning solution. 6) Re-connect the power cord and resume parts cleaning operations. Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 3

ULTRASONIC GENERATORS 795-91322 This machine utilizes dangerous high voltage to operate the ultrasonic transducers. Only qualified trained personnel should attempt any repairs or servicing of the ultrasonic components. Disconnect all power before servicing the ultrasonic generators or tank heaters. If in doubt about any servicing procedures, contact Graymills customer service department at (773) 248-6825. The ultrasonic cleaner has a fan to cool the electronic components. The fans may become blocked with lint or debris that will inhibit the free flow of air. Periodically (every 2-3 months) under normal conditions, the fan should be inspected (for debris build-up), cleaned and placed back into service. Disconnect all power before starting cleaning. GENERAL DAILY MAINTENANCE 1) Inspect the power cord and connector for deterioration or damage. Repair or replace a damaged power cord or connector immediately. 2) Do not allow the ultrasonic cleaner to sit on a wet surface. Wipe up any water or cleaning solution from the tank mounting surface. 3) Remove any parts that may drop into the tank. Turn off the ultrasonic generators and heaters, and allow the cleaning solution to cool to room temperature before immersing your hands into the cleaning fluid. Use rubber gloves to protect your hands. WEEKLY MAINTENANCE 1) Wash the cleaning tank interior as described on page 4. 2) Inspect the drain valve and fitting for leaks. Repair any leaks immediately. Replace the drain valve if necessary. 3) Wipe the tank cabinet with a damp (NOT WET) cloth to remove accumulated detergent residues and soils. If left on the cabinet, the detergent residues may produce a permanent stain on the metal surfaces. Never under any circumstances immerse this equipment in water. Permanent damage, personnel injury and/or other property damage will result if this equipment is immersed. APPLICATIONS PRINCIPLES OF ULTRASONIC CLEANING Ultrasonics is defined as a mechanical vibration above the range of human hearing (i.e., above 18,000 Hz.). Ultrasonic cleaning refers to the use of ultrasonic energy to assist in the cleaning of soiled objects while they are immersed in a cleaning fluid. Typical frequencies used in ultrasonic cleaning are: 20 khz, 25 khz, 40 khz and 80 khz. Every ultrasonic cleaning system consists of three basic components: 1) An Ultrasonic Generator that converts 50 or 60 Hz. electric power from the electric utility supply to a high frequency electric signal in the ultrasonic range. 2) Ultrasonic Transducers to convert the ultrasonic electrical signal into mechanical vibrations. 3) A tank with the ultrasonic transducers bonded to its exterior and that contains the cleaning fluid and workpieces. The tank is filled with a fluid suitable for the cleaning application. When the ultrasonic generator is activated, the transducers begin to vibrate at their natural frequency and couple the ultrasonic energy into the cleaning fluid. If sufficient energy is produced, the fluid molecules are pulled apart, creating microscopic voids or bubbles. This phenomenon is called cavitation. These cavitation bubbles increase and shrink in size in step with the ultrasonic frequency. Above a certain energy threshold, the bubbles will grow to an unstable size and then suddenly collapse, releasing a tremendous amount of energy into the fluid. If a soiled workpiece is immersed in the fluid, the cavitation bubbles will tend to collapse on the surfaces of the parts. This creates a scrubbing action that literally blasts away the contaminants from the parts. Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 4

TIPS AND GUIDELINES FOR EFFECTIVE CLEANING 1) Choose a workbasket with the largest openings possible without allowing the parts to fall through. 2) For extremely small parts, a solid bottom basket with weep holes is preferred. 3) If the parts tend to nest or stick together, gentle agitation or tumbling will insure that the cleaning fluid reaches all the surfaces. 4) Hollow or concave parts should be positioned so that they fill and drain completely during the cleaning cycle. Remember that the ultrasonics can only reach where the cleaning fluid reaches. 5) Choose a detergent or cleaning fluid that is effective against contamination on the parts without damaging the parts or part surfaces. Always test a cleaning fluid with a sample part before cleaning a large workload. 6) Use the mildest cleaning fluid that will be effective in your application. Start with the weakest dilution ratio recommended by the detergent manufacturer and gradually add more concentrate until satisfactory cleaning is obtained. 7) Gentle heating usually improves the cleaning performance. The optimum cleaning range is between 120 F and 140 F. Higher temperatures may be required in some applications. SPECIFICATIONS Tank Dimensions (Inches) Model Tank Capacity Ultrasonic Power Heater Power L W D Power Required BTU-4 4.15 Gal. 250 W. 500 W. 12 8 10 120 V BTU-7 7.33 Gal. 500 W. 500 W. 14 11 11 120 V BTU-17 17 Gal. 750 W. 1,000 W. 20 14 14 120 V Materials of Construction: Standard Accessories: Optional Accessories: Tank: 14 ga. T316L stainless steel Cabinet: 16 ga. T304 stainless steel Adjustable, thermostatically-controlled tank heater Stainless steel mesh parts basket ¾ N.P.T. brass drain valve ¼ thick polypropylene tank cover with handle Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 5

WARRANTY Graymills Corporation warrants that the equipment manufactured and delivered, when properly installed and maintained, shall be free from defects in workmanship and will function as quoted in the published specification. Graymills does not warrant process performance, nor assume any liability for equipment selection, adaptation, or installation. Warranty does not apply to damages or defects caused by shipping, operator carelessness, misuse, improper application or installation, abnormal use, use of add-on-parts or equipment which damages or impairs the proper function of the unit, and modifications made to the unit. Warranty does not apply to expendable parts needing replacement periodically due to normal wear and tear. A new Warranty period shall not be established for repaired or replaced materials or products. Such items shall remain under Warranty for only the remainder of the Warranty period of the original material or product. THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, WHETHER ORAL, WRITTEN, EXPRESSED, IMPLIED OR STATUTORY. GRAYMILLS CORPORATION MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESTATED OBLIGATION ARE HEREBY DISCLAIMED BY GRAYMILLS CORPORATION AND EXCLUDED FROM THIS SALE. Graymills warranty obligations and Buyer remedies (except to title), are solely and exclusively stated herein. In no case will Graymills be liable for consequential damages, loss of production, or any other loss incurred due to interruption of service. Graymills' obligation under this Warranty shall be limited to: 1. Repairing or replacing (at Graymills sole discretion) any non-conforming or defective component within one year from the date of shipment from Graymills. 2. ULTRASONIC EQUIPMENT On parts cleaners equipped with ultrasonics, the ultrasonic transducers are guaranteed against cracking, depolarizing or becoming detached from the radiating surface for a period of ten (10) years from the date of shipment from Graymills. This warranty does not cover transducer failure that results from operating the equipment with insufficient liquid in the tank as evidenced by inspection by Graymills. 3. Repairing or replacing (at Graymills sole discretion), components supplied by, but not manufactured by Graymills, to the extent of the warranty given by the original manufacturer. 4. This warranty does not cover rusting of a mild-steel parts cleaner used with aqueous (water-based) materials. On ultrasonic equipment, the finish of the stainless steel tank interior or the immersible transducer radiating surface is excluded from this warranty as erosion of these surfaces occurs normally during the course of operation. Buyer must give Graymills prompt notice of any defect or failure. If you believe you have a Warranty claim, contact Graymills at (773) 248-6825. Any return material must have an RMA number on the outside of the package and shipping prepaid or shipment will be refused. Graymills will promptly examine the material and determine if it is defective and within the Warranty period. Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 6