COMPLETE SOLUTIONS FOR MAGNETIC MEDIA MANAGEMENT V660 HDD



Similar documents
TECHNICAL MANUAL. Operating and Maintenance Instructions for. Manual Degausser

V94 BULK TAPE DEGAUSSER

Security Approved Degausser

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

How To Use A Power Supply Unit (Upu)

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SERVICE MANUAL REFRIGERATION

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

INFRARED QUARTZ WALL HEATER

Oil and Coolant Circulating Heating System. Model - OCSM

Single Channel Loop Detector

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Online UPS. PowerWalker VFI 1000R/1U

StorTrends 3400 Hardware Guide for Onsite Support

User's Instructions. Alpha HE CB25/33 and HE SY25

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ML 3320/3321. English. Read Me First SEL SEL MENU SHIFT TOF FF/LOAD EXIT GROUP ITEM SET PRINT POWER ALARM MENU TEAR PARK

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Bubble King. User Manual

Floodlight Range Installation Guide

USER S MANUAL HSC-24A

Hot Water Urns. all models. Helpline. v3.0

LUCCI AIRFUSION QUEST II CEILING FAN

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

COLOR VIDEO DOOR PHONE CDV-71BE/D

User s Manual AURORA 1.2K/2.2K

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

10000HXL31/15000HXL31/20000HXL31

Portable Air Conditioner

TMS TANK MANAGEMENT SYSTEM

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Digital Keypad Use s Manual

, User s Manual

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

WARMER or COOKER/WARMER

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

3 IN 1 BATHROOM HEATER

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Cooktop Low-Profile Ventilation Hoods

Triac Printed Circuit Board Replacement

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

MOUNTING AND OPERATING INSTRUCTIONS

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

EKOS Cart. Instructions for Use

TECHNICAL MANUAL. Operating and Maintenance Instructions for DATAGAUSS LG AND DATAGAUSS XL-LG HARD DRIVE DEGAUSSERS

SF15K SF05KSS, SF10KSS

Wall-Mounting your HP computer. User Guide

User Manual 1K/2K/3K Online UPS

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Yaesu FT-736R PSU repair

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

ATS Overhead Table Shelf System INSTRUCTION MANUAL

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

Meaco 30L and Meaco 40L dehumidifier instruction manual

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Bulb Replacement REPLACING BULBS WARNING

Fundamentals of Power

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

User Manual THR840DUK Digital Thermostat

AIR-CONDITIONER SPLIT TYPE

POWER WAVE 455M/STT & (CE)

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

GenStore Archive Cabinet

Manual for Fire Suppression & Methane Detection System

SunMaxx Solar Filling Station Operating Instructions

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Doc. No: Issue: 1 Date: Aug BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

SERVICE SERVICE MANUAL FOR ALDE ELECTRICAL HEATER

TIG INVERTER INSTRUCTION MANUAL

Operating instructions in the back. PD1020L

UV100A Ultraviolet Air Treatment System

WIRELESS HOME ALARM SYSTEM (WHA1)

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

User Manual. Video Doorphone CDV-1020AQ

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Transcription:

COMPLETE SOLUTIONS FOR MAGNETIC MEDIA MANAGEMENT V660 HDD Evo Hard Disk Drive Degausser OPERATING & MAINTENANCE MANUAL

Thank you for purchasing a Verity Systems V660 HDD Evo Degausser OPERATING & MAINTENANCE MANUAL Document Reference No. M000301 Production Standard ZZ 009 167 (60 Hz) ZZ 009 168 (50Hz) VERITY SYSTEMS LTD VERITY SYSTEMS, INC. 2 Eastern Road 5441 Merchant Circle, Unit A Aldershot Placerville Hampshire California GU12 4TD 95667 United Kingdom United States Tel: +44 (0) 1252 317000 Tel: (530) 626-9363 Fax: +44 (0) 1252 316555 Fax: (530) 626-9395 Email: sales@veritysystems.com Email: ussales@veritysystems.com www.veritysystems.com 2 of 21

WARNING! This unit emits a strong magnetic field. Remove wrist watches before use. Personnel fitted with a Cardiac Pacemaker should not stand within 0.5 metres of the unit. Operating periods in excess of specified duration will result in exterior surfaces becoming very hot. To help minimise the possibility of electrical shock hazards under no circumstances should any panels be removed CAUTION! It is recommended that magnetic storage media is kept at least 2 metres from the degausser COPYRIGHT IMPORTANT! The power on/off switch used on this equipment is not an isolating switch. it is recommended that this equipment should be operated from a separate switched isolator which should be located close to the unit and within reach of the operator. This document is the property of Verity Systems and it may not be reproduced, copied or exhibited to a third party without the written permission of Verity Systems. Verity Systems reserves the right to amend or modify the specifications and design criteria applying to these products. 3 of 21

Table of Contents Section 1 SPECIFICATION 6 Section 2 INTRODUCTION 7 Section 3 INSTALLATION 8-9 3.1 Unpacking 8 3.2 Power Requirements 8-9 Section 4 OPERATION 9-10 4.1 Erasure of Hard Disk Drives Locally 9-10 4.2 Erasure of Hard Disk Drives Remotely Section 5 INDICATORS/FEATURES 11 5.1 Indicators 11 5.2 Warning Indicators 11 5.3 IR Sensor 11 5.4 Overheat Protection 11 5.5 Cooling 11 5.6 Protection 11 Section 6 MAINTENANCE/SERVICE 11-13 6.1 Circuit Breaker 11 6.2 Bulb Replacement 12 6.3 Coolong Fan 12 6.4 Internal Components 12-13 Section 7 TECHNICAL SUPPORT 13 4 of 21

Table of Contents Cont d Appendix A Basic Fault Finding Table 14-15 Appendix B Current Monitor Test Points 16 Appendix C Parts List 17-18 Appendix D Circuit Diagrams 19-20 5 of 21

SECTION 1: SPECIFICATION Hard Drives Erased 3½" PC Hard Disk Drives Power Requirements (factory set) ZZ 009 167 ZZ 009 168 Line Voltage: 220/240v 115v Line Frequency: 50Hz 60Hz Current (typical): 10A 14A Protection Circuit 12A 16A Erasure Time: 5 seconds typical Run Time: 10 minutes typical Duty cycle : Non-continuous. Average 10 minutes. Mounting: Free standing table top Overall Dimensions: Depth:19 inches (480mm) Width: 16.5 inches (420mm) Height: 6 inches (150mm) Weight: Approximately 77lbs/35kg 6 of 21

SECTION 2: INTRODUCTION The V660 HDD Evo degausser functions like a large electro magnet, its erasing field originating as leakage flux from a large gap in the field structure, the V660 s structure is basically a U section. The field intensity decreases rapidly as the distance from the degausser surface increases. For example at a distance of approximately 2.75 inches from the degausser's surface a field strength of only 50 oersteds exists. Furthermore, the erasing field present at the front edge nearest the operator is also very low. Hard Disk Drives The vulnerability of information stored on PC hard drives is a recognised security risk. Unlike other PC data storage media the hard drive always stays with the PC. Every time a PC leaves a company s control all the data and company information will go with it. Even if the hard drive breaks down the storage platters will still contain information which could be read once repaired. In keeping with our policy of recognising user requirements we have introduced the V660 HDD Evo eraser. The V660 HDD Evo is capable of removing data from PC hard drives in less than 5 seconds. Although in most cases this will render the hard drive inoperative, the cost of a replacement hard drive cannot be compared to the cost to a company if sensitive information can be read by a third party. 7 of 21

SECTION 3: INSTALLATION 3.1 Unpacking Unpack the degausser carefully, and verify that all parts are present. If there are missing or damaged parts contact Verity Systems or an authorised partner/reseller immediately to correct any miss-packed or missing parts. You should find the following : Verity Systems V660 HDD Evo degausser Infrared remote control switch Power cable This user manual 3.2 Power Requirements Check the power supply requirements on the label attached to the back of the equipment with the available supply. The unit is supplied with a flying 3 wire cable which, when connected to a properly wired receptacle, earths the unit. It is essential that a proper earth connection is made to assure safe operation. Caution! A good electrical ground must be connected to the degausser. The unit must be connected to the correct power supply. Failure to do so may result in permanent damage. Connections Wire Colour 50 Hz 60 Hz Brown Live Hot Blue Neutral Cold Yellow/Green Earth Ground IMPORTANT INSTRUCTION The mains supply outlet socket should be close to the installed equipment and fully accessible. Note: Degausser Current Consumption The degaussing coils are powered as part of a tuned resonant circuit. This allows quite high circulating currents to be generated within the degaussing coils, with minimal current consumption from the mains voltage supply. However, this technique requires that the waveform of the supply voltage contains minimal harmonic distortion. A distorted waveform will result in an increase in current consumption. In extreme cases excessive current will trip the circuit breaker making it necessary to use a mains filter to remove the distortion and reduce the current consumption. 8 of 21

The typical current consumption figures provided in this manual are when powered from a supply with minimal distortion. Any increase in current consumption due to a distorted waveform will have minimal effect on the degausser performance, however, excessive current consumption should be avoided for obvious reasons. In the event of unexplained high currents, please consult your supplier. SECTION 4: OPERATION WARNING! STRONG MAGNETIC FIELDS ARE GENERATED. REMOVE WATCHES BEFORE USE ENSURE THAT THE FAN OPERATES CORRECTLY DURING USE. (AFTER INITIAL WARM UP PERIOD). OPERATING PERIODS IN EXCESS OF SPECIFIED DURATION WILL RESULT IN EXTERIOR SURFACES BECOMING VERY HOT. The V660 HDD Evo has been designed for simplicity of operation and erases hard disk drives in a single operation. The V660 HDD Evo can be operated locally or remotely via the infrared control Because of the different types and manufactures specifications of PC hard disk units, Verity Systems only recommends the erasure of hard disk units as a security precaution for the following. a. Erasure of data from a faulty disk pack before being sent for service/repair. b. Erasure of data from disk packs before disposal of computer equipment. Note: Verity Systems cannot guarantee that a drive will be operational after degaussing. 4.1 Erasure of Hard Drives Locally 1. With the red power switch off, lift the lid on the top of the degausser. 2. Place the hard disk drive into the foam receptacle. 3. Close the lid 4. Ensure the key switch is in the upright position indicating LOCAL operation (see image A). 5. Press the red POWER switch Note: The illuminating on/off power switch is of the latching push button type which energises the degaussing coil. 6. The yellow DEGAUSS indicator light will illuminate. 7. After 5 seconds, press the red POWER switch to stop erasure 8. Remove the erased hard disk drive Image A 9 of 21

4.2 Erasure of Hard Disk Drives Remotely 1. Ensure the key switch is turned 90 degrees clockwise indicating REMOTE operation (see image B). 2. With the unit switch on, lift the lid on the top of the degausser. 3. Place the hard disk drive into the foam receptacle. 4. Close the lid. 5. Point the remote control at remote control sensor on the degausser (see diagram C) and hold down the large button on the control. 6. The yellow DEGAUSS indicator light will illuminate. 7. After 5 seconds, release the button on the remote control to stop erasure. 8. Remove the erased hard disk drive. 9. Switch unit off Image B Image C 10 of 21

SECTION 5: INDICATORS/FEATURES 5.1 Indicator The degauss indicator (large yellow button) is provided to give an indication of degausser coil energisation. Certain circumstances can arise when, although the unit is switched on, the degauss coils may not be energised. 5.2 Warning indicator The field failure indicator is provided to give further reassurance that the degauss field is present. The indicator is considered more reliable being a red LED. 5.3 IR Transmitter The infrared transmitter LED illuminates when the remote control is in operation. 5.4 Overheat Protection The high energy field developed by the V660 HDD Evo necessitates the generation of a considerable amount of heat. The degausser coil is monitored for excessively high temperatures and should this condition occur its operation will be inhibited until the coil has cooled sufficiently. 5.5 Cooling A thermostatically controlled cooling fan is provided to extend the operating period to a maximum. 5.6 Protection The unit is protected by a thermal type circuit breaker. The current rating depends on the specified operating voltage. Infrared Sensor Degauss Indicator Lights Remote/Local Operation Key Switch Local Degauss On/Off Button IR Transmitter 11 of 21

SECTION 6: MAINTENANCE/SERVICING The unit is basically maintenance free but periodic checks should be made to ensure the correct operation of the fan and the good condition of the power cable. Note: To reduce the risk of shock hazard, disconnect the degausser from the mains voltage supply before carrying out any maintenance or servicing. 6.1 Circuit Breaker To reset the circuit breaker simply 'push in' and 'release' the button. 6.2 Bulb Replacement Note: Remove Power from the unit before replacing bulbs. 6.2.1 Remove the "bulb lens" from the "switch/indicator body" by levering it forwards. Neon Voltage Model Power Switch Indicator ZZ 009 167 220-240v 220-240v ZZ 009 168 115v 220-240v 6.2.2 Remove the bulb from the rear of the "bulb housing" using a suitable extraction tool. 6.2.3 Replace the bulb noting the following: Note: The bulb will fit in only one position in a locating slot. If when fitting this does not occur, remove the bulb and rotate it through 180. 6.2.4 Refit the "bulb lens" to the "switch/indicator body" gently pushing the lens into the "switch/ indicator body" housing. 12 of 21

6.3 Cooling Fan The cooling fan is of the conventional axial type powered from the ac voltage supply. The unit is over temperature and over current protected and does not require servicing. However in the event of failure the fan may easily be replaced from the rear of the degausser. 6.4 Internal Components Most of the internal components are replaceable, i.e. the solid state relay, toroidal transformer (60Hz only) and the thermal switches mounted on the degausser coil. However the tuning capacitors and the degaussing coil are not spared items and if found to be faulty the unit should be returned to Verity Systems for repair. To access the components inside the degausser the laminate cover must be removed. This entails breaking the adhesive seal using a sharp blade. 6.4.1 Solid State Relay Replacement A thermally conductive compound should be used to ensure adequate heat dissipation from the relay to the metal case. 6.4.2 Thermal Switch Replacement Care must be exercised when replacing either of the switches on the degausser coil. The switches are fitted using an epoxy resin and it is recommended that the new switch be fitted in a new position on the coil and the old switch be left in place. The wire connections are of the 'push on' spade type and are easily transferred to the new switch. A high temperature epoxy resin part no. EA 200 001 should be used to secure the new switch. 6.4.3 Cover replacement The laminate cover should be cleaned of old adhesive before refitting, using the sealant part no. EA 100 007 and high temperature tape, Part No. HS100143 SECTION 7: TECHNICAL SUPPORT You should first attempt to get technical assistance from your dealer or authorised partner/reseller. Verity Systems support personnel can be reached at: Verity Systems Ltd. Verity Systems, Inc. 2 Eastern Road 5441 Merchant Circle, Unit A Aldershot Placerville Hampshire CA 956567 GU12 4TD United States United Kingdom Toll Free: (800) 642-5151 Tel: +44 (0) 1252 317000 Tel: (530) 626-9363 Fax: +44 (0) 1252 316555 Fax: (530) 626-9395 E-mail: uksupport@veritysystems.com E-mail: ussupport@veritysystems.com 13 of 21

APPENDIX A BASIC FAULT TABLE The table assists fault finding down to component levels. However, should the degaussing coil or tuning capacitors be found to be faulty it is recommended that the unit be returned to Verity Systems for repair. Function Symptoms Possible Fault Location Fails to erase drive and Circuit Breaker CB1 repeatedly tripped Incorrect supply voltage.frequency Faulty degauss coil L1 and /or tuning capacitors C1-C4 Power Lamp Fails to illuminate Loss of mains supply. User source Inside centre, left hand side User source Degauss lamp & Warning Lamp Fails to illuminate Tripped circuit breaker Faulty switch Faulty Neon Extensive use of degausser caused overheating. Allow unit to cool (not a fault). Faulty neon Faulty solid state relay R1 Faulty thermal switch SW2 Rear panel Front panel Front panel Front panel Inside on right hand side Inside on front end of degaussing coil Faulty transformer TX1 (115v 60 Hz only) Cooling Fan Fails to Operate Faulty thermal switch SW3 Faulty Fan M1 Inside front on left hand side Inside on front end of degaussing coil Rear Panel 14 of 21

Note: Degausser Current Consumption The degaussing coils are powered as part of a tuned resonant circuit. This allows quite high circulating currents to be generated within the degaussing coils, with minimal current consumption from the mains voltage supply. However, this technique requires that the waveform of the supply voltage contains minimal harmonic distortion. A distorted waveform will result in an increase in current consumption. The typical current consumption figures provided in this manual are when powered from a supply with minimal distortion. Any increase in current consumption due to a distorted waveform will have minimal effect on the degausser performance, however, excessive current consumption should be avoided for obvious reasons. In the event of unexplained high currents, please consult your supplier. 15 of 21

APPENDIX B: CURRENT MONITOR TEST POINTS The following table contains typical current values to be measured at specific points in the equipment. The values given are in amperes and may differ slightly from those actually measured due to component tolerance plus effects due to operating temperature. Model Voltage/Frequency Current Monitor Test Points 1 2 3 4 5 6 ZZ 009 167 ZZ 009 168 220v-240v 50 Hz 115v 60 Hz 10 N/A 71 30 37 0.09 14 8 72 39 29 0.19 16 of 21

APPENDIX C: PARTS LIST ZZ 009 168 (115V 60Hz) Designation Part No. Quantity Description CA 100 005 1 Cable gland 16mm TB2 CG 200 001 4 Terminal Block TB2 CG 200 002 1 End Cover TB2 CG 200 003 0.4 Jump Bar TB1 CM 100 023 0.25 Terminal Block FM 100 033 1 Guard 120mm metal M1 FM 100 042 1 Fan 120mm HS 100 101 4 Feet Ind 1 OI 100 031 1 Neon SW1 OI 100 030 1 Neon RL1 RS 100 010 1 Relay SW3 SW 100 061 1 Temperature Sensor SW2 SW 100 060 2 Thermal Switch CB1 SW 100 0143 1 Circuit Breaker 16A SW1 SW 100 123 1 Red lens SW1 SW 100 125 1 Switch Body SW1 SW 100 126 1 Switch Contacts IND1 SW 100 121 1 Yellow Lens IND1 SW 100 124 1 Indicator Body IND1 SW 100 127 1 Dummy Socket TX1 TX 100 030 1 Auto Toroid Transformer XX 003 065 1 Fan Plate SW2 SW 100 070 1 Mode Key Switch Ind2 OI 100 064 1 Led Indicator R1 RP 200 035 1 390 ohm Resistor RL2 XX 005 219 1 IR Sensor D1 SD 100 025 1 Rectifier Diode TX1 TX 100 069 1 Transformer C6 CC 100 071 1 100 µf Capacitor XX 005 274 1 Fixed top XX 005 276 1 Hinged lid XX 005 218 1 IR Transmitter V660 HDD Evo Degausser 17 of 21

PARTS LIST ZZ 009 167 (220-240V 50Hz) Designation Part No. Quantity Description CA 100 005 1 Cable gland 16mm TB2 CG 200 001 4 Terminal Block TB2 CG 200 002 1 End Cover TB2 CG 200 003 0.4 Jump Bar TB1 CM 100 023 0.25 Terminal Block FM 100 033 1 Guard 120mm metal M1 FM 100 027 1 Fan 120mm HS 100 101 4 Feet SW1 & Ind 1 OI 100 031 2 Neon RL1 RS 100 010 1 Relay SW3 SW 100 061 1 Temperature Sensor SW2 SW 100 060 2 Thermal Switch CB1 SW 100 066 1 Circuit Breaker 12A SW1 SW 100 123 1 Red lens SW1 SW 100 125 1 Switch Body SW1 SW 100 126 1 Switch Contacts IND1 SW 100 121 1 Yellow Lens IND1 SW 100 124 1 Indicator Body IND1 SW 100 127 1 Dummy Socket XX 003 065 1 Fan Plate SW4 SW 100 070 1 Mode Key Switch Ind2 OI 100 064 1 Led Indicator R1 RP 200 035 1 390 ohm Resistor RL2 Xx 005 219 1 IR Sensor D1 SD 100 025 1 Rectifier Diode TX1 TX 100 069 1 Transformer C6 CC 100 071 1 100 µf Capacitor L1 MP 002 325 Filter XX 005 274 1 Fixed Top XX 005 276 1 Hinged Lid XX 005 218 1 IR Transmitter 18 of 21

19 of 21

20 of 21

Supplied by: Verity Systems Ltd. Verity Systems, Inc. 2 Eastern Road 5441 Merchant Circle, Unit A Aldershot Placerville Hampshire CA 95567 GU12 4TD United States United Kingdom Toll Free: (800) 642-5151 Tel: +44 (0) 1252 317000 Tel: (530) 626-9363 Fax: +44 (0) 1252 316555 Fax: (530) 626-9395 E-mail: sales@veritysystems.com E-mail: ussales@veritysystems.com