NEXT GENERATION GREEN DATA CENTRES



Similar documents
How To Power And Cool A Data Center

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

How To Design A Data Center

Cloud Provider Solutions

Leveraging Radware s ADC-VX to Reduce Data Center TCO An ROI Paper on Radware s Industry-First ADC Hypervisor

ICT and the Green Data Centre

INFRASTRUCTURE SOLUTIONS OVERVIEW

CHOOSING A RACKSPACE HOSTING PLATFORM

BCS Foundation Certificate in Data Centre Infrastructure Syllabus. Version 1.2 March 2015

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Data centre experts. Advanced power protection for data centres

InfraStruxure Data Centre Management Software. Holistic open standards integrated data centre management solution.

June 2009 Questions and answers on the topic Green VoIP

Huawei Data Center Facility Integration Solution

Global Green Data Center Best Practices In Action

Enabling an agile Data Centre in a (Fr)agile market

High-density modular data center making cloud easier. Frank Zheng Huawei

Juniper Networks Universal Edge: Scaling for the New Network

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

WHO ARE WE AND WHAT WE DO?

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

Building a data center. C R Srinivasan Tata Communications

A Solution Guide. Converged Infrastructure and Private Cloud

PROPRIETARY CISCO. Cisco Cloud Essentials for EngineersV1.0. LESSON 1 Cloud Architectures. TOPIC 1 Cisco Data Center Virtualization and Consolidation

Data Centre Outsourcing a Buyer s Guide

Business Case for a DDoS Consolidated Solution

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

T:

Business Case for the Brocade Carrier Ethernet IP Solution in a Metro Network

Server Room Thermal Assessment

Juniper Networks QFabric: Scaling for the Modern Data Center

Data Center Technology: Physical Infrastructure

AIRAH Presentation April 30 th 2014

Capgemini UK Infrastructure Outsourcing

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

How to build your Data Center Digitice roadshow Vaasa

VMware Cloud Environment

Opex-based data centre services: Co-location, managed services and private cloud business support

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

Next Gen Data Center. KwaiSeng Consulting Systems Engineer

INFRASTRUCTURE ARCHITECTURE BLUEPRINT

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Management and Wireless in the Data Center

SOLUTION BRIEF KEY CONSIDERATIONS FOR LONG-TERM, BULK STORAGE

Enterprise Cloud Solutions

Storage Trends Choice-Solutions Ltd.

Introducing UNSW s R1 Data Centre

Energy-efficient & scalable data center infrastructure design

RiMatrix S Make easy.

Cloud Based Document Management

Data Centers That Deliver Better Results. Bring Your Building Together

Connected College Gives Online Learning a Boost in Hertford. Europe s fastest education network takes revenue and collaboration into the cloud

HP 3PAR Takeaway Document

opdc Cut your data center OPEX upto 70%

Big Solutions for Small Business

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Universal Wideband Edge QAM Solution. A New Way to Manage the Edge and Future-Proof Your Network

Server-centric client virtualization model reduces costs while improving security and flexibility.

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

Green Data Center and Virtualization Reducing Power by Up to 50% Pages 10

Automating Infrastructure A connectivity perspective for BICSI SEA meeting, November 2011

ENERGY EFFICIENT DATA CENTRES AND STORAGE. Peter James University of Bradford

EUCLYDE.com. availability. your priority...our mission

GUIDELINE. on SERVER CONSOLIDATION and VIRTUALISATION. National Computer Board, 7th Floor Stratton Court, La Poudriere Street, Port Louis

Green Data Centre Design

Re Engineering to a "Green" Data Center, with Measurable ROI

Data Center Facility Basics

World s Greenest High Performance Data Center

Data centres that deliver

SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays

Scalability & Capacity Planning: Build vs. Buy

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Anglia Ruskin University opts for a VDI deployment

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Specialty Environment Design Mission Critical Facilities

ExaGrid Stress-free Backup Storage

Cloud Computing, Virtualization & Green IT

Automation's Modular Containerized Datacenter Solutions

Transcription:

I M T E C H J A M E S M O R G A N & F R A N K B R A N D NEXT GENERATION GREEN DATA CENTRES Friday, May 15, 2009

PROFILE IMTECH N.V Global provider of technical services in the area of: Electrical engineering Mechanical engineering Information Communication Technology Turnover 3.8 billion euro 24,000 employees 19,500 customers Publicly held at the AEX Measurable value add to our customers by: Total solutions from consultancy and design to build, integration and maintenance.

IMTECH UK

WHERE WE OPERATE CONTENT- DATA CENTRES Internet information & Software apps APPLICATIONS HD TV, TVoD, VoD, Content Providers Video Source Voice/Video Telephony Gaming, DR, ERP Host applications, Consolidated Servers BUILDINGS NETWORKS Enterprise Clients Research & Education Small/Medium Business SoHo & Residential Triple-Play Mobile data/video

IMTECH EXPERTISE BMS Electrical power & UPS Cabling Infrastructure Access & Security control Monitoring & Maintenance Server SAN Dynamic Infrastructure Virtualise & Consolidate Storage Servers Security Modernise & Improve Applications Processes Network Infrastructure Ubiquitous connectivity Security Service Assurance

DATA CENTRES - KEY CHALLENGES 1. New Application Software Models 2. Explosion in Infrastructure 3. Consolidating Data Centre 4. Virtualisation 5. More Network 6. Need for Green 7. Increasing Complexity

Common Rail Cooling Imtech innovates to the core of your Data Centre: The next generation DC combines "Common Rail Cooling to deliver maximum availability and the lowest possible TCO. May 14th, 2009 F. Brand

SHARED OBJECTIVES Minimising TCO Use of scalable designs Energy optimisation CO2 reduction Faster realisation of data centres Upgrade of data centres with minimal downtime Flexible in availability-factor: mixing Tier 1-4 Green IT design Meeting the EU-code of conduct on Data centres

DESIGN PRINCIPLES Data rooms with regulated access per aisle Air handling plenum Utilities

SUSTAINABLE IS CHEAPER? Why? Energy is one of the major cost drivers in data centres Power availability is a key factor in locating DC s Optimisation of energy consumption drives down your TCO Current DC s perform mostly at 1,8 to 2,2 EnergyUsageEffiency (EUE) factor How? Designing Green DC s without rising CAPEX Energy overhead (EUE) factor far better (1,2) than the new EU code of conduct (1,3) Saving for a medium sized DC (10 MW) are ca. 3,5 Mio Euro s per year compared with current avarage!!! This solutions needs 4 Mw Power less and is therefore more flexible and cheaper to locate

DESIGN Goals: Managed services Optimizing E,M,ICT, Security combination EUE possible < 1.2 Strategy: Flexibility, modular design with off-the-shelf major components Back-up systems, major components power and cooling outside cooled zone Sectioning walls for flexible spatial optimalisation Outside or roof mounted heat exchangers N + 1 redundancy Secure logistics through seperation of disciplines E,M,ICT and customers, reducing security costs

Example Data Center Server ports 3,800 x 10/100/1000 Overview Architecture CORE: 2 Catalyst 6509E, SUP720 with total of 80 WS-X6148A-45AF 48 ports each plus Firewall Blade ACCESS: 17 Catalyst 6509E, SUP32 with total of 4 WS-X6708A-10G Xenpak ports 6509E-SUP32 Traditional 6509E- SUP720 6509E-SUP32 6509E- SUP720 Juniper CORE 20 EX4200-24 ports plus 2 ISG 2000s ACCESS 79 EX4200-48 ports plus 1 EX4200-24 port Capital Expenditure Equipment $ 2,213,895 $ 1,611,930 28% Saving Environmental Power 203,171 kwh 168,358 kwh 17% Saving Space 399 RU 107 RU 73% Saving Annualised Costs $ 164,635 $ 63,180 62% Saving Operational Annual Maintenance $72,581 $ 51,889 28% Saving

COME AND SEE US ON OUR STAND NO.1 FREE wireless energy monitor for first 20 registrations