Operating Instruction for Humidity/Temperature- Measuring Instrument. Model: AFH-G

Similar documents
Operating Instructions for Plastic Flow Meter. Model: KSK

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

How To Read A Pipe From A Sensor

Instruction Manual. T3111 T3111L T3111P T3111Ex

Duct Humidity Transmitter

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ACS-30-EU-EMDR-10-MOD

Mounting Instructions. Torque Transducer. A en

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

FIRERAY 2000 Installation Guide

Cross-beam scanning system to detect slim objects. 100 mm in

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Drayton Digistat +2RF/+3RF

Incubator with mechanical convection

HERZ-Thermal Actuators

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Capteur température et humidité pour HVAC

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Instruction Manual Differential Pressure Transmitter

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Cable Plug acc. to DIN EN , Form A

Material test chamber with mechanical convection

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

PART 1 - INTRODUCTION...

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Digital inductive conductivity transmitter

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Analog signal converters CC-E I/I Current / current isolators

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

T0118 T2118 T3118. Instruction Manual

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Radiant Temperature Sensor TY7321

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

RM4TG20 three-phase network control relay RM4-T - range V

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

The Do s and Don ts of Pressure Transducers

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Mounting instructions. Force transducer. A en

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Antenna Splitter ASA 1. Instruction manual

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Actuator-Sensor-Interface

GREISINGER electronic GmbH

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

DLP-PU/E Instruction Manual

SELECTION, APPLICATION AND MAINTENANCE

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Model: DC-A2IO Advanced HVAC Controller

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Power Thyristor TS3 (SP) 3ph. Installation Guide

Adjustment functions for both span and shift have been incorporated

Proportional pressure regulators VPPE

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Residual current socket 30mA Order No.:

Electronic overload relay EF19 and EF45

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

W 36: Mastering complex tasks reliably

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Electronic overload relay EF65, EF96 and EF146

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Accurate Air Flow Measurement in Electronics Cooling

Type: DILM9 10(24VDC) Article No.:

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Color Mark Sensor with Red or Green LED E3S-VS

Inductive sensor NI10-M18-Y1X-H1141

MINI MCR-SL-R-UI(-SP)

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

How To Build A Low Voltage Capacitor Lvcp

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DLO1191 Linear smoke detector

COMBIMASS. Technical Data COMBIMASS eco-bio +

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Operating Instructions. Room temperature controller

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Type: DILM32 10(24V50HZ) Article No.:

Three-phase monitoring relay CM-PFE

PHOENIX CONTACT Features

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

MOUNTING AND OPERATING INSTRUCTIONS

Wind Sensor W-RS485 with RS485 Interface

KOBOLD VKP FLOWMETER/SWITCH. User Instructions

Transcription:

Operating Instruction for Humidity/Temperature- Measuring Instrument Model: AFH-G

1. Note Please read and take note of these operating instructions before unpacking and setting the unit for operation, and follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and with the prevailing regulation applying to procedural safety and the prevention of accidents. 2. Contents 1. Note... 2 2. Contents... 2 3. Specific Application... 3 4. Operating Principles... 3 5. Instrument Inspection... 5 6. Mechanical connection... 5 7. Electrical connection... 7 8. Technical Data... 8 9. Order Codes... 9 10. Maintence and Instruction for use... 9 11. Calibration... 10 12. Dimensions... 11 13. Declaration of Conformance... 12 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com Seite 2 AFH-G 07/02

3. Specific Application The AFH-G is to be installed only in the specified applications. Every usage which exceeds the specifications is considered to be non-specified. Any damages resulting thereform are not the responsibility of the manufacturer. The user assumes all risk for such usage. The application specifications include the installation, start-up and service requirements specified by the manufacturer. 4. Operating Principles The type AFH-G measuring instrument serves to measure relative humidity indoors and in air ducts. Auxiliary temperature measurement is available as an option. The moisture sensing element in the sensor comprises several strips of plastic fabric each with 90 fibres of 3 µm diameter. These plastic fibres undergo a special process to acquire hygroscopic properties, this means that they absorb and release moisture. The molecular structure of the fibres changes when they absorb water, giving rise to a measurable change in length. The length of the plastic fibres is thus a measure of the relative humidity. The swelling effect, acting primarily in the longitudinal direction, is sensed by an electronic pick-off system and transferred to an integrated signal preprocessing system. The output signal of the passive sensors is 100-138.5, and 4-20 ma for the active sensors. The special treatment of the measuring element ensures that its hygroscopic properties remain stable, that is sensitivity is maintained until destroyed by external influence. Regeneration found in conventional instruments is not required here, but is also not damaging. The measuring element is protected by a perforated tube and is open to the housing. Measuring instruments with an integrated temperature sensor provide temperature measurement. The temperatures are also converted to the standardized signals 0-20 ma, 0-10 V, and 4-20 ma. 4.1. Design of the sensor The expanding action (predominantly lengthways) of the fibres is picked up by means of an electronic sensing system and converted by integrated signal preprocessing into standardised signals 0..20mA or 4..20mA or 0...10V. AFH-G 07/02 Seite 3

The fan-shaped measuring element, which faces outward from the housing, is protected by a perforated sensor tube. The sensors are designed for pressureless systems. The unit should be installed in a location where condensation cannot enter into the housing. A preferred position would be sensor vertically down or sensor horizontal. In these positions, a cover plate with a 0.8 mm diameter hole will prevent water from entering. The AFH-G range of sensors have built-in temperature sensors (mainly Pt100) for simultaneous measurement of temperature. Temperature readings are converted likewise into standardised signals 0..20mA or 4..20mA or 0..10V. 4.2. Ageing In order to maintain their long-term stability, it is important that the measuring elements undergo a special ageing process, details of which cannot be given here. 4.3. Reaction of the sensor Due to the law of diffusion, there is a time delay before the fibres are saturated during water absorption. This is a decisive factor when determining the reaction time. Thus, for one individual fibre with a diameter of 3 µm, a short saturation time (several seconds) can be measured. Empirical investigations show that bundled or woven fibres, as are used here in the Kobold sensor, give rise to a longer period prior to saturation. This is because the individual fibres impede each other during water absorption and/or water loss, and the ensuing humidity does not register until later. Measurements have shown that, at a wind speed of 2m / sec. the half-life period is 1.2 mins. This represents an effective period of approx. 30-40 mins. Seite 4 AFH-G 07/02

80º C is given as the maximum temperature value. Higher temperatures can only be tolerated for a short period of time. The eventual result is a change in the molecular structure which causes a constant error. The maximum temperature of 80º C only applies, however, if no harmful substances (acids, solvents etc.) are present in the medium. 4.4. Humidity and tolerance diagram 5. Instrument Inspection These devices are checked before dispatch and sent away in perfect condition. Should the damage to a device be visible, we recommend a thorough inspection of the delivery packing. In case of damage, please inform your parcel service/ forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: Measuring Unit Model AFH-G Operating Instructions 6. Mechanical connection Unavoidable sources of interference should be kept at a good distance from the control systems. Data and signalling lines should not be used in parallel with control, networking and power lines. AFH-G 07/02 Seite 5

For data and signalling lines, shielded cable should be used, and the shielding must be applied to the earth terminal. Ensure that earth circuits and fault currents do not arise as a result of a second earth connection. For equipment with a network connection, it is recommended that a separate network circuit be used. During the switch process, electrical power consumers such as switch contactors, magnetic valves etc. produce induction voltages that can cause interference. In the trade there is an abundance of protective and suppressor component parts that are most effective when applied directly to the source of the trouble. A suitable suppressor has the added advantage that components such as relays, microswitches etc. have a longer service life. Further difficulties during installation can arise if signalling lines are joined together with common lines. It is essential to check whether this is permissible. Interference is particularly likely when installing using equipment of different makes. Here, too, the trade offers isolating amplifiers that overcome the problem. Installation: The installation position should be chosen so as to prevent condensed water from entering the housing. The preferred installation position is "sensor vertically pointing downwards" or "sensor horizontal". A grommet in the probe prevents penetration of water in the installation positions described above. Wall mounting set Seite 6 AFH-G 07/02

7. Electrical connection 7.1. Passive sensors 7.2. Active sensors AFH-G 07/02 Seite 7

8. Technical Data 8.1. Humidity Measuring range: Measuring accuracy: Recommended operating range: 0-100% RH > 40% RH: ±2.5% RH < 40% RH: ±3.5% RH 30-100% RH 8.2. Temperature Measuring range: Measuring accuracy: Measured medium: Allowed ambient temperature: Average temperature coefficient: Allowed air speed: Half-life at V=2 m/s: Sensor length: Sensor material: Mounting: Installation position: Connection terminals: passive sensors: +5 to +80 C active sensors: -30 to +60 C ±0.5 C air, pressureless, non-aggressive at housing: -20 to +60 C at sensor: -40 to +80 C -0.1% RH/K (at 20 C and 50% RH) 8 m/s with gauze protection (optional) 15 m/s 1.2 min 220 mm stainless steel holes in housing base for duct mounting Bracket for surface mounting (optional) sensor vertical pointing down, or horizontal for conductor cross-sections 0.5 mm Cable connection: Cable gland PG 13.5 Electromagnetic compatibility: Noise immunity: EN 50 082-2 emitted interference: EN 50 081-2 Housing: ABS Protection: IP 64 Weight: approximately 0.4 kg Seite 8 AFH-G 07/02

9. Order Codes 10. Maintence and Instruction for use The measuring element is maintenance free when the surrounding air is clean. Agents that are corrosive and contain solvents, depending upon the type and concentration of the agent, can result in faulty measurements and cause the measuring element to break down. Direct sunlight should be avoided. Substances deposited on the sensor are damaging as they eventually form a waterrepellent film (this applies to all humidity sensors with hygroscopic measuring elements). Such substances are resin aerosols, lacquer aerosols, smoke deposits etc. The water-resistant property of the Kobold sensors allows for cleaning using water. Solvents cannot be used for this purpose. A light-duty detergent is recommended. Any detergent residue should, however, always be thoroughly washed out. A special process ensures that Kobold sensors have good long-term stability. Regeneration is not necessary, but is also not harmful. The temperature coefficient as well as the self-heating may vary according to the location and the application (especially with sensors where electronic and measuring system are integrated in one housing). The guarantee is no longer valid if the interior of the measuring element has been accessed. AFH-G 07/02 Seite 9

11. Calibration Kobold sensors are adjusted correctly at a room temperature of 23ºC and 50%rh at a mean air pressure corresponding to 430m NN. If, however, a further adjustment is necessary, the following procedure should be adhered to : Ensure that the ambient humidity as well as the ambient temperature are constant. If possible, use a psychrometer for testing, (do not use testing equipment with capacitive sensors). Leave the equipment to be tested for a minimum of 1 hour under constant test conditions. All Kobold sensors are equipped with an adjustment facility. In most cases this involves an adjuster screw fixed with screw securing lacquer. When the lacquer is removed the screw can be adjusted. After calibration, the adjuster screw should again be secured. Important: The air s capacity to absorb water is influenced among other factors by the temperature. This is a physical law (identified in the hx diagram of Mollier). The higher the air temperature, the larger the amount of steam that can be absorbed up to saturation point (100%rh). If a sensor is calibrated under varying air temperature conditions, the result is an irregular, unhomogenous measuring medium which automatically gives calibration errors. The table below shows the influence of the air temperature on air humidity. If, for example, calibration occurs at an air temperature of 20ºC and 50%rh and a varying temperature range of only +/-1 ºK, this results in a variation in humidity of the measuring medium (air) of +/- 3.2%rh. Seite 10 AFH-G 07/02

12. Dimensions AFH-G 07/02 Seite 11

13. Declaration of Conformance We, KOBOLD-Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Humidity/Temperature- Measuring Instrument Model: AFH-G to which this declaration relates is in conformity with the standards noted below: DIN EN 60730-2-1 1993 VDE 0631 2 1989 IEC 730-2-1 Also the following EWG guidlines are fulfilled: 73/23/EWG 89/336/EWG Unterschrift: Datum: 22.06.01 Seite 12 AFH-G 07/02