BL18 - Power Supply and Battery Charging Unit

Similar documents
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Operating Manual UWAPS-TINY Series

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Thyristor-controlled power supplies and battery chargers

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

PHOENIX CONTACT - 01/2007

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

MINI MCR-SL-R-UI(-SP)

APD / Outputs 19" DC/DC Converter, 50 Watt

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

ST Series POWER SUPPLIES USER INSTRUCTIONS

Three-phase monitoring relay CM-PFE

Energy Management Energy Meter Type EM23 DIN

Safety technique. Emergency stop module BO 5988 safemaster

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Redundancy Module QUINT-DIODE/40

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

EGSTON Standard E2xFxWx 12W

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

RM4TG20 three-phase network control relay RM4-T - range V

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Quick Connect. quick - simple - efficient.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Industrial Power Supplies

Technical data UNIBLOCK UBSF

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Actuator-Sensor-Interface

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

is then retained absolutely without interruption.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Product and functional description

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Power Supplies 3. SDN-P DIN Rail Series

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Pluggable interface relays CR-P Pcb relays

Type: DILM9 10(24VDC) Article No.:

R.C.C.B. s two-pole LEXIC

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

MPR-Systems. Mini Power Racks 1200 W W

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

HERZ-Thermal Actuators

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

RY2 miniature industrial relays

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

SURGE PROTECTIVE DEVICES

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Waveguide Access Point WGA631. Product Guide

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MasterINTERFACE 39 Series - Relay interface modules

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Rack mounted telephone- and leased line modem for industrial applications

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Cable Plug acc. to DIN EN , Form A

Photovoltaic Solar Energy Unit EESFB

MasterINTERFACE 39 Series - Relay interface modules

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Analog signal converters CC-E I/I Current / current isolators

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Instruction Manual for Operating Panel 301 and 302

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electronic overload relay EF19 and EF45

Type: DILM32 10(24V50HZ) Article No.:

Drayton Digistat +2RF/+3RF

40 Series - Miniature PCB/Plug-in relays A. Features

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Transcription:

BL18 - Power Supply and Battery Charging Unit

Contents 1 Application 2 Characteristics and Features 3 Functions and Adjustments 3.1 Mounting and Connecting 3.2 Application as stabilized power pack supply unit 3.3 Application as battery charger 3.3.1 Battery charging in compliance with I-V Characteristics 3.4 Reduction of the power output 4 Technical Data 5 Order form 1 Application The BL18 is a versatile direct voltage supply unit that can be applied both, as battery charger and as stabilized power pack supply unit. If applied as battery charger, the BL18 serves to either charge or to maintain closed or gas-proof 24 V leadacid batteries in full charge condition by providing the facility to simultaneously supply consumers with DC current (parallel operation). When the BL18 is operated in parallel with a battery or with another consumer and the battery has to be disconnected, e.g. for maintenance or exchange, the supply of this consumer will be backed-up to the battery charger s nominal capacity. Thanks to the unit s short-circuit capacity, it must not be switched off in case of short-circuit type occurrences, such as e.g. start of an Diesel engine or similar situations. As stabilized power pack supply unit, the BL18 supplies connected consumers with a stabilized DC voltage that can be adjusted within a range of 24V to 27.5 V and/or 12 V to 24 V. Attention! The internal over voltage protection of the BL18 is up to the standards as per EN6100-4-5 whereas particular over voltage situations (e.g. lightning effects, switching actions, converter reactions etc) that might occur in switchgear assemblies, may lead to an overload and even destruction of the unit s internal protection. For the energy coordination of an external over voltage limitation, it is therefore essential that the deviceinternal over voltage protection function of the BL18-400 will be available from a line-to-line voltage of 624 Vac_rms and up! For the voltage limitation, star connected metal-oxide varistors (MOV) of the type S14K320 are applied. In case that the coordination with external over voltage protection can not be realized or ensured, we would recommend to connect impedances in series with the mains supply inputs of the BL18-400 in order to assure the energy limitation of the device s internal over voltage protection. 2 Characteristics and Features Input voltage 3 x 530 V AC ±15% 1 x 230 V AC ±15% Safety according to VDE 0805/EN 60950 Surge voltage stability according to EN 6100-4-5 High stability of output voltage Low residual ripple High efficiency Screw type and plug-in connectors Suppression of radio interferences acc. to VDE 0875/T11/EN 55011, class B Interference immunity according to EN 50082-2 Short-circuit and no-load proof Compact housing Low weight (1.9 kg) Snap-on fastening on DIN rail Indication of working condition (via LED) 2 TD_BL18_06.06_GB

3 Functions and Adjustments Apart from the lower plug-and-socket connector, the BL18 is equipped with a trimming potentiometer for the adjustment of the output voltage (see fig. 3.1). By means of a normal slotted screwdriver, the output voltage can be adjusted within a range of 24 v to 27.5 V and from 12 V to 14 V. Turning the screwdriver to the left reduces and turning it to the right increases the output voltage. The LED at the front plate of the unit indicates readiness for operation. Figure 3.1: Ausgang Output Adj: 24-27,5 V 12-14 V Secondary side connecting terminals and trimming potentiometer for the output voltage 3.1 Mounting and Connecting Attention! For all servicing or installation works, the locally valid safety instructions have to be observed. The secondary side plug connectors have two parallel connection terminals per pole (+/-) but the current can also be carried by one terminal only. 3.2 Application as stabilized power pack supply unit As a stabilized power pack supply unit, the BL18 provides a constant output voltage that each depending on the selected adjustment value - ranges from 24 V to 27.5 V/DC or from 12 V to 14 V/DC. The output voltage is maintained up to the rated current s load value. If this value is exceeded, the output voltage will automatically be reduced. To allow best possible cooling, the proper mounting position has to be unconditionally observed taking into account that input terminals (L1/L2/L3/PE or L1/N/PE) have to be placed on top and the output terminals (+/-) at the bottom. There must be a head space of at least 100 mm above and below and of at least 30 mm at both sides of the BL18 device. The inlet air temperature must not exceed the admissible ambient temperature specified in the technical data. Connection of the three-phase input voltage is to be made according to the scheme that is printed on the housing of the unit. For this purpose it is not necessary to observe the indicated phase sequence. The feed lines (= primary sides?) of the unit should be protected by either a three-pole L-miniature circuit breaker or via a three-pole motor protecting switch (adjusted to 2.5 A). It is not allowed to operate the unit if one of the phases had failed. The protected earth (PE) of the BL18 and protected earth of the switchboard have to be connected. Installation of the switchboard has to be carried out in compliance with the regulations VDE 0100 and VDE 0160. Figure 3.3: Current limitation Figure 3.2: Mains Connection TD_BL18_06.06_GB 3

3.3 Application as battery charger For the loading of lead acid batteries at normal temperatures up to 30 C, the trickle charge voltage recommended by battery manufacturers is 2.25 V per cell, i.e. the trickle charge voltage for a 24 V leadacid battery would be 27 V per cell. At higher ambient temperatures, charging voltages have to be reduced and must be increased accordingly in case of external voltage losses. The factory default setting for the units BL18-400-24 and BL18-230-24 is an output voltage of 27 V/DC. 3.4 Reduction of the power output At an ambient temperature of more than 60 C the load capacity of the unit will decrease proportional as shown in the diagram below. 3.3.1 Battery charging in compliance with I-V Characteristics Charging is effected according to I-V characteristics (see fig. 3.4). The initial discharge capacity / rating is high, i.e. approx. 21 23 A (I-charge). During discharging of batteries a high initial charging current of approx. 21-23 A (I-charge) flows that is limited by the BL18. As soon as the charging voltage reaches the adjusted value (trickle charge voltage) there is transition to charging at constant voltage (U-charge). In doing so the charging current will decrease until the unit supplies a lower trickle current and the current that is possibly required by connected consumers. In this case the advantage of this charging method - compared to loading at constant current - becomes quite obvious: The reduction of current upon reaching of the trickle charge voltage avoids overcharge of the battery thus preventing inadmissibly high generation of gas which would be the case if a high charging continued flowing after the battery s full charge. Figure3.5: Reduction of the power output To avoid overheating of the units, it is necessary to reduce the consumer load accordingly. Figure3.4: Charging acc. to IU-characteristic 4 TD_BL18_06.06_GB

4 Technical Data General Data Type: Permissible operating time: Connection terminals: Type of cooling: Maintenance: Short circuit: No-load: Mounting position: BL18 continuous operation max. 2.5 mm² (wire connection) convection cooling none sustained short circuit proof sustained no-load proof wall mounting, input terminals on top, output terminals at bottom Input Circuit (three-phase) Input voltage : 3 x 530 V AC ±15% at U sec = 24 V DC/18 A, +15%/-10% at U sec = 27.5 V DC/18 A Over voltage protection: star connected metal-oxide varistors (MOV) S14K320 Application (1 ma-value): 510 V (single varistor) Energy absorbtion: 84 J (2 ms) (single varistor) Input rated current: 3 x 1.5 A (24 V type)/3 x 0,8 A (12 V type) Frequency range: 47-63 Hz In-rush current: <50 A Power factor cosϕ: 0.55 capacitive Fuse: three-pole miniature c.b. or motor protection switch (setting 2.5 A) Input Circuit (single-phase) Input voltage : 1 x 230 V AC ±15% at U sec = 24 V DC/18 A, +15%/-10% at U sec = 27.5 V DC/18 A Input rated current: 4.4 A (24 V type)/2.4 A (12 V type) Output Circuit Output voltage: 27 V DC ±1% / 13,5 V DC ±1% (preset by manufacturer) Setting range: 24-27.5 V (24 V type)/12-14 V (12 V type) Max. output current: 18 A Limitation of current: typically 20 A, starting point at 18.5... 21.5 A limit point at 20.0... 26.0 A Output: 480 W Residual ripple: <100 mv Efficiency: 90% Max. power loss: 53 W Load capacity of output terminals: 20 A at T U = 0 C up to +45 C 0.2 A- reduction/ C from +45 C to 17 A at T U = +60 C Regulation Mains regulation: <0.1% of the output voltage at U mains ±15% Load regulation: <0.1% of the output voltage between 0 and 20 A Correction time: <2 ms at a load change from 10 to 90% of rated current, overshooting <2% Mains failure bridging time: >5 ms at U mains = 400 V AC and U sec = 24 V DC / 16 A TD_BL18_06.06_GB 5

Tests and regulations Radio-interference suppression: Static discharge ESD, IEC 801-2: Electromagnetic fields, IEC 801-3: Burst IEC 801-4: Surge IEC 801-5, EN 6100-4-5: VDE 0875 part 11, EN 55011 class B 8 kv contact discharge 15 kv air discharge 10 V/m 4 kv input 2 kv output, capacitive coupling 4 kv asymmetric, 4 kv symmetric Safety rules VDE 0805/11.93, EN 60950, IEC 950 Test voltage: 3 kv AC : all safety relevant components 1.5 kv DC: finished product between primary and secondary side 1.5 kv DC: finished product between primary and protection earth 0.5 kv DC: finished product between secondary and protection earth protection class: class I Degree of protection: IP20 Discharge current: <0.75 ma (47-63 Hz mains frequency and U mains, max ) Operating data Temperature range during operation: during storage: Derating of output: 0 to +70 C, with free convection -25 to +85 C 2.5 %/K above +60 C (see Fig.3.5) Housing Dimensions (Width x Height x Depth): 240 mm x 130 mm (153 mm) x 86 mm Space for convection: above and below the unit 100 mm, at the sides 30 mm Weight: approx.1.9 kg Mounting: DIN-rail mounting acc.to DIN EN 50022-35 6 TD_BL18_06.06_GB

Figure4.1: Housing dimensions All dimensions in mm! Please observe! A free space of at least 100 mm must be left above and below the BL18, and of at least 30 mm at both sides. 5 Order form Power supply and battery charging unit BL18- Output current 18 A Input voltage 230 V 1-phase 400/530 V 3-phase Output voltage 12 V (12-13.75 V DC) 24 V (24-27.5 V DC) 230 400 12 24 TD_BL18_06.06_GB 7

Woodward SEG GmbH & Co. KG Krefelder Weg 47 D 47906 Kempen (Germany) Postfach 10 07 55 (P.O.Box) D 47884 Kempen (Germany) Phone: +49 (0) 21 52 145 1 Internet Homepage http://www.woodward-seg.com Documentation http://doc.seg-pp.com Sales Phone: +49 (0) 21 52 145 635 Telefax: +49 (0) 21 52 145 354 e-mail: kemp.electronics@woodward.com Service Phone: +49 (0) 21 52 145 614 Telefax: +49 (0) 21 52 145 455 e-mail: kemp.pd@woodward.com