Order by phone Order on-line Order by fax Website

Similar documents
Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters

4-Channel Thermometer / Datalogger

Conductivity and TDS Meters

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

ExStik TM ph Waterproof Meters

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

User Guide. Temperature and Humidity Datalogger. Model 42280

Compact ph Measuring Instruments

How To Use An Irius Pid Detector

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

USB-500/600 Series Low-Cost Data Loggers and Accessories

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Galvanic Parts Per Million Dissolved Oxygen Systems

Model 4510 Conductivity/TDS Meter Operating Manual

Conductivity measurements are used for applications such as in the production of ultrapure water or determining the salinity of sea water.

Milwaukee USER MANUAL

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Melting Point Apparatus

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Hand-held thermometer Model CTH7000

Wahl C50 Calibrator FEATURES

Incubator with mechanical convection

Temperature & Humidity SMS Alert Controller

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Wireless Data Logger Monitoring Systems

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

rigel 288 Electrical Medical Safety Analyser Key Features Applications

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Melting Point Range. with BioCote antimicrobial protection

Highly efficient flue gas analyzer

User Manual. Thermo Scientific Orion VERSA STAR

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

USB-500/600 Series Low-Cost Data Loggers and Accessories

Dual Laser InfraRed (IR) Thermometer

DISSOLVED OXYGEN METER Model : DO-5509

User's Guide. Integrating Sound Level Datalogger. Model Introduction

USB-500 Series Low-Cost Data Loggers and Accessories

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

PAT Tester Printers and Barcode Scanners

SevenGo Duo. Quick and Reliable Measurements for Results at your Fingertips. SevenGo Duo Portables SevenGo Duo SevenGo Duo pro

Ultrasonic Load Monitoring

ph 200 ph-/redox-/temperature Meter Operating instructions

Data Logging Solutions from Lascar Electronics

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Equipment for Analysis

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

TurbiDirect TurbiCheck TurbiCheck WL

Current Monitoring Kit QUICK START GUIDE

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

RS DIGITAL THERMOMETER

Ground Resistance Clamp On Tester

MIT510/2, MIT520/2 and MIT1020/2

PortaSens ll G AS DETECTOR

Distributed by TestEquity LLC

UltraBasic Benchtop ph Meter Operation Manual

Operating Instructions

Physical Specifications (Custom design available.)

New thermometers and accessories to grow your business

1.44 kw Programmable DC Power Supplies XLN Series

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

Test equipment for temperature and its reduction

HT580 User Reference Guide. Version 1.0

Fluke 3000 FC Series Test Tools Technical Data

Repeaters and Mimics Data Sheet

Ion-selective Measurements

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Multifunction HVAC and IAQ Meter

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

SMS GSM Alarm Messenger

Interface Level And Point Level Analyzers & Sensors

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Current Monitoring Kit

Compact Water Quality Meter B-700 series

OT 40L / 90L. Laboratory Steam Sterilizers

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Microwave Meter. Instruction Manual

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

Premium Server Client Software

Multi-Range Programmable DC Power Supplies 9115 Series

Operating manual. ph/cond 3400i. Tref25 nlf C TP CAL. ph/conductivity measuring instrument. ba75687e01 01/2007

HOBO U14 Data Logger User Manual

TR Series Surface Roughness Tester for workshop and laboratory

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

STERILIZERS, LABORATORY DRYING OVENS

Integrating Sound Level Meter and Datalogger

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Transcription:

Mettler Toledo, X-mate Pro, Multi-parameter, Meter The X-mate pro is a multi-parameter, portable meter. Consisting of the base unit MX300, to which you can fit a wide choice of sensors. Parameters include conductivity, ph, salinity, TDS, dissolved oxygen, redox, mv, humidity, ISE and temperature. Unique Duo and Trio sensor modules ideal for environmental monitoring are available. These include ph and conductivity, (plus dissolved oxygen on the Trio) all with built-in temperature. Data logging allows you to take automatic readings at time intervals ranging from 1 minute to 24 hours. The memory allows storage of up to 199 readings along with date, time and identification number, which can be downloaded to a PC when convenient. 223-102 10 parameters GLP Data logging Electrode condition indicator Single handed use reminder Multi-parameter modules Measuring range Conductivity, µs/cm 10.00 to 1999 Conductivity, ms/cm 2.00 to 199.9 ph 0.000 to 14.000 mv ±1999 Temperature, C 0 to 80.0 Oxygen, % 0.0 to 200.0 Oxygen, mg/l 0.0 to 20.0 Concentration, ppm 0.001 to 19999 Humidity, %rh 0 to 100 Thermocouple, C -50 to 950 Concentration calibration 3 points ph calibration 3 points Automatic temp. compensation yes Battery operating period, hrs 200 223-100 MX300 Base unit supplied without sensor modules which POA must be ordered separately 223-103 MX300 Base unit and large field case (empty). Case can take POA up to five sensors. Supplied without sensor modules which must be ordered separately 223-102 Mono-mate kit. Comprises MX300 base unit, InLab 482 ph POA sensor module, standard field case and buffer sachets 223-101 Trio-mate kit. Comprises MX300 base unit, InLab 781 POA conductivity, InLab 482 ph and InLab 681 dissolved oxygen sensor modules, large field case and buffer sachets 223-104 InLab 781 Conductivity sensor module, 4 ring cell with POA integral temperature probe 223-105 InLab 481 ph sensor module, plastic shaft POA 223-106 InLab 482 ph sensor module plastic shaft with POA integral temperature probe 223-107 InLab 489 ISFET ph sensor module with integral POA temperature probe 223-108 InLab 681 Dissolved oxygen sensor module with POA integral temperature probe 223-109 InLab 982 Duo module. Two parameter sensor module POA ph/conductivity with integral temperature probe 223-110 InLab 983 Trio module. Three parameter sensor module POA ph/conductivity/dissolved oxygen integral temperature probe 223-111 InLab 986 Humidity sensor module POA 223-112 RS232 Interface module POA 223-113 0.9m Extension cable POA 223-114 10.0m Extension cable POA Other sensor modules are available, please enquire on 01342 826836 for details. 223-109 223-108 223-100 shown with 223-106 223-104 223-101 271

223-035 Hanna, HI-98311 and HI-98312 Waterproof Conductivity/ TDS/ C Meters Pocket testers with simultaneous display of EC/TDS and temperature on an LCD screen. Automatic calibration and buffer recognition combine with adjustable automatic temperature compensation for a fast and accurate performance. Ergonomically designed, the waterproof case floats if dropped in water and also has a user replaceable twist & lock probe. Other features include; auto-off switch, stability indicator, low battery indicator, and adjustable EC/TDS conversion factor. Two versions available, depending on the conductivity/tds range. Model HI-98311 HI-98312 Range 0 to 3999µS/cm 0.01 to 19.99mS/cm 0 to 1999ppm 0.00 to 10.00ppt 0 to 60 C or 32 to 140 F 0 to 60 C or 32 to 140 F Resolution 1µS/cm 0.01mS/cm 1ppm 0.01ppt 0.1 C 0.1 C ±2% Full scale, ±0.5 C ±2% Full scale, ±0.5 C Auto at single point 1413µS, Auto at single point 12880µS/cm, 1382ppm or 1500ppm 6.44ppt or 9.02ppt Temp. comp. Auto with ß variable from 0.0% to 2.4% (both models) Battery 4x1.4V, approx 100 hours life with Hanna BEPS system (both models) Dimensions, mm 163x40x26 (both models) Weight, g 85 (both models) Cat No. Description Price 223-035 HI-98311 conductivity/tds/ C meter POA 223-087 HI-98312 conductivity/tds/ C meter POA 223-041 Batteries, 1.4V, pack of 12 POA 223-005 223-006 Hanna, HI-8633 and HI-8733 Multi-range Conductivity Meters Two meters ideal for production and quality control which use a 4-ring multi-range PVC probe to measure from deionized water to brine. for the entire range of readings is assured with single point calibration. Where the temperature fluctuates, use the HI-8733 with ATC together with an adjustable coefficient (b) from 0 to 2.5% per C, to ensure accuracy. Two year warranty on both models. Model HI-8633 HI-8733 Ranges 0.0 to 199.9µS/cm 0.0 to 199.9µS/cm 0 to 1999µS/cm 0 to 1999µS/cm 0.00 to 19.99mS/cm 0.00 to 19.99mS/cm 0.0 to 199.9mS/cm 0.0 to 199.9mS/cm Resolutions 0.1µS/cm 0.1µS/cm 1µS/cm 1µS/cm 0.01mS/cm 0.01mS/cm 0.1mS/cm 0.1mS/cm ±1% Full Scale ±1% Full Scale Manual Manual Temp. comp. Manual from 10 to 40 C, Automatic with an adjustable β with β of 2% per C from 0 to 2.5% per C Probe Included with 1 m cable Included with ATC and 1 m cable Battery type/life 1 x 9 V/100 hours approx.continuous use (both models) Dimensions, mm 185x82x45 (both models) Weight, g 55 (both models) 223-005 HI-8633 conductivity meter with probe and battery POA 223-006 HI-8733 conductivity meter with probe and battery POA 472-083 Spare probe for model HI-8633 POA 472-084 Spare probe for model HI-8733 POA 472-057 Standard solution, 500 ml of 12880µS/cm for recalibration POA 272

Jenway, Model 470, Conductivity/TDS Meter A general purpose, hand held unit with ergonomic design. The liquid crystal display simultaneously shows temperature compensated conductivity or TDS and temperature. The casework is environmentally protected to IP65 making it ideal for the field or any portable situation. It is supplied with epoxy cell (K=1), batteries and instructions. The new results memory function allows 32 readings to be stored in non-volatile memory (results are retained even with no batteries fitted). These results are easily recalled and displayed on the LCD. Backlit LCD Environmentally protected case to IP65 Results memory function 500 hours of battery life* Direct calibration on standard solutions or by direct cell constant entry Simultaneous temperature reading Start up self test (validity check of both system and operator entered values) Carrying case included 223-077SP New * Typical @ 25 C with alkaline cells Conductivity Ranges/resolution 0 19.99 µs/0.01 µs 0 199.9 µs/0.1 µs 0 1999 µs/1 µs 0-19.99mS/0.01mS 0-199.9mS/0.1mS 0-1999mS/1mS* ±0.5% ± 2 digits TDS Range/resolution 0-19.99mg/l/0.01mg/l 0-199.9mg/l/0.1mgl 0-1999mg/l/1mg/l 0-19.99g/l/0.01g/l 0-199.9g/l/0.1g/ 0-1999g/l/1g/l* ±0.5% ± 2 digits Temperature Range/resolution -10 to 105 C/0.1 C or 14 to 221 F/1 F ±0.5 C/± 1 F ATC range 0 to 100 C/32 to 212 F Manual temp. comp. range 0 to 100 C/32 to 212 F Cell constant Digitally settable 0.01 to 19.99 Reference temperature 18, 20 or 25 C settable Temperature coefficient 0.00 to 4.00%/ C linear EC ratio (TDS) 0.50 to 0.80 Auto standard recognition 10µS, 84µS, 1413µS or 12.88mS (manual override) Power 2 AA cells Dimensions (lxwxd), mm 175x75x35 Weight, g 250 * only with cell constant >5 223-077SP Model 470 Conductivity/TDS meter supplied with epoxy cell (K=1), POA batteries and instructions. Supplied with carry case 273

223-076 Jenway, Models 4150 and 4200 Waterproof Conductivity Meters Completely waterproof and portable with robust, non-glass sensor. The 4150 and 4200 models are both supplied with epoxy conductivity cell (K=1), batteries and instruction manual. An in-built sensor gives a direct read-out of temperature. Model 4150 Conductivity/TDS/ C Meter This standard sensor has a nominal cell constant of 1.00. The meter also enables the digital selection of cell constant values between 0.015 and 19.99 to facilitate the use of the wide range of cell options offered. Data logging up to 100 results Auto standard recognition Menu driven operation User selectable coefficient 223-048 Model 4200 Conductivity/Resistivity/Salinity/TDS/ C Meter The measuring range of the model 4200 conductivity meter of 0 to 199.9mS is covered by five automatically switched ranges using a single cell. The in built software is able to calculate and report results as total dissolved solids (T.D.S.) in mg/l, salinity in g/l or resistivity in MΩ. The model 4200 offers the facility to download data held in memory to a printer or computer. 1-3 point calibration Auto standard recognition Fully GLP compliant RS232 interface using optional cradle Multi-lingual Mode Conductivity TDS Resistivity Temperature Salinity (4200 only) (4200 only) Ranges/resolution 0 199.9mS/ 0 200g/L/ 0 20MΩ/ -10 to 105 C/ 0 99.9g/L/ 0.1mS 0.1g/L 0.01MΩ 0.1 C 0.1g/L 0 19.99mS/ 0 20g/L/ 14 to 220 F/ 0.01mS 0.01g/L 1 F 0 1.999mS/ 0 2000mg/L/ 0.001mS 1mg/L 0 199.9µS/ 0 200mg/L/ 0.1µS 0.1mg/L 0 19.99µS/ 0 20mg/L/ 0.01µS 0.01mg/L ±0.5% ±0.5% ±0.5% ±0.5 C/ 0 35 ±1/ ±2 digits ±2 digits ±2 digits ±1 F 35 99 ±3 Cell constant (digital) Settable 0.015 19.99 (both models) Ref. temp. 18, 20, 25 C (both models) Temp. coefficient 0.00 to 4.00%/ C linear (both models) Probes 4 plate configuration for 4200/2 plate configuration for 4150 223-076 Model 4150 conductivity meter supplied with epoxy cell with ATC (K=1), POA batteries and instruction manual 223-048 Model 4200 conductivity meter supplied with epoxy cell with ATC (K=1), POA batteries and instruction manual 223-049 Carrying case POA 223-050 0.01 M conductivity standard POA For model 4200 223-075 Conductivity cell K=1 POA 469-099 40 column printer POA 472-133 Paper roll for printer POA 472-134 Printer ribbon POA 469-100 Interface cradle POA 469-101 Interface cable kit POA 274

Hanna, HI-9033 Waterproof, Conductivity Meter Rugged and robust, this waterproof hand-held conductivity meter has been designed for use in the field. Featuring single point calibration and automatic temperature compensation, the extensive measurement range is obtainable from a single probe on a 1m cable. Supplied with conductivity probe, batteries and tough carry case Four selectable ranges Automatic temperature compensation Two year warranty Four ranges 0.0 199.9µS/cm, 0 1999µS/cm, 0.00 19.99mS/cm and 0.0 199.9mS/cm Resolution 0.1µS/cm, 1µS/cm, 0.01mS/cm and 0.1mS/cm ±1% full scale Single point Temperature compensation Automatic from 10 C to 50 C Probe With ATC probe Operating temp., ºC 0 to 50 Dimensions, mm 196x80x60 Weight, g 425 223-023 HI-9033 conductivity meter with probe, battery and case POA 223-025 12,880µS/cm calibration solution, 460ml POA 472-059 1,413µS/cm calibration solution, 460ml POA 223-027 84µS/cm calibration solution, 460ml POA 223-028 80,000µS/cm calibration solution, 460ml POA 223-023 Hanna, HI-9835 Waterproof Multi-range Conductivity/ TDS/ Salinity/ C Meter An extended range waterproof conductivity meter, which also reads TDS, NaCl and temperature. yet suitable for use in the laboratory, all measurements are taken with just one probe with readings displayed on a large dual level LCD screen. With improved resolution and accuracy, the meter can read from de-ionised water to sea water, automatically switching ranges. Main features include automatic calibration with seven pre-programmed buffers, automatic temperature compensation with optional manual or nil compensation for actual conductivity readings, adjustable temperature coefficient and stability indicator. Can be run from mains supply with optional power pack. Supplied complete with probe on 1m of cable, batteries and attaché case. 223-051 Mode Conductivity TDS Salinity Temperature Ranges/Resolution 0.0 29.99µS/cm / 0.01µS/cm 0.0 14.99ppm / 0.01ppm 0.0 400.0%/0.1 0.0 60.0 C/0.1 30.0-299.9µS/cm / 0.1µS/cm 15.0-149.9ppm / 0.1ppm 300-2999µS/cm / 1µS/cm 150 1499ppm / 1ppm 3.00-29.99mS/cm / 0.01mS/cm 1.50 14.99g/L / 0.01g/L 30.0-200mS/cm / 0.1mS/cm 15.0 100.0g/L / 0.1g/L up to 500.0mS/cm actual EC up to 400.00ppt ±1% of reading (0.05µS/cm ±1% of reading (0.03 ppm ±1% of reading ±0.4 C or 1 digit whichever greater) or 1 digit whichever greater) 1 point procedure with 6 memorised buffers at; 0.0, 84.0, 1413µS/cm, 12.88, 80.0, 111.8mS/cm. NaCl at 100%. Temperature compensation Auto or manual from 0 to 60.0 C (can be disabled to measure actual conductivity). /TDS factor With adjustable coefficient from 0.00 to 6.00%/C. TDS factor adjustable from 0.40 to 0.80 Battery type/life 4x 1.5V AA/150 hours approx. continuous use, or 12vdc mains supply. Auto-off after 5 minutes (can be disabled) Dimensions, mm/ Weight, g 196x80x60/ 500 223-051 HI-9835 waterproof conductivity/tds meter with probe, batteries and carry case. POA 223-080 HI-12VDC Mains power adaptor POA 223-025 12,880µS/cm calibration solution, 460ml POA 223-027 84µS/cm calibration solution, 460ml POA 472-059 1,413µS/cm calibration solution, 460ml POA 275

223-084 Hanna, HI-991300 and HI-991301 Waterproof Conductivity/ TDS/ ph/ C Combination Meters New waterproof hand held combined meters measuring conductivity, ph and temperature all with one probe. Simply press a button to go from one parameter to the next. for ph is at two points from 5 memorised buffers. One point conductivity calibration is automatic with user selectable conversion factor. Also features a stability indicator and battery power check. Supplied with combination probe/electrode and attaché case. ph Conductivity TDS Temperature, C Ranges HI-991300 0.00 to 14.00 0-3999µS/cm 0 1999ppm 0-60 HI-991301 0.00 to 14.00 0-19.99mS/cm 0 10.00ppt 0-60 Resolution HI-991300 0.01 1µS/cm 1ppm 0.1 HI-991301 0.01 0.01mS/cm 0.01ppt 0.1 HI-991300 ±0.01 2% full scale 2% full scale ±0.5 HI-991301 ±0.01 2% full scale 2% full scale ±0.5 Dimensions (wxdxl), mm 143x80x38 (both models) Weight, g 320 (both models) 223-084 HI-991300 conductivity meter/tds/ph/ C meter with probe and attaché case POA 223-085 HI-991301 conductivity meter/tds/ph/ C meter with probe and attaché case POA 223-086 Replacement probe POA 667-103 Protective rubber boot POA 472-059 1413µS/cm, 460ml calibration solution for HI-991300 POA 223-025 12880µS/cm, 460ml calibration solution for HI-991301 POA 472-051 ph 4.01 ph buffer solution, 460ml POA 472-053 ph 7.01 ph buffer solution, 460ml POA 223-058 Hanna, HI-933000, Compact Conductivity Meter The HI-933000 is a robust, portable conductivity meter with a useful wrist strap and an optional outer protective rubber holster for field use. It uses the Hanna 4-ring technology which allows the meter to sample from de-ionised water through to brine without the need to change probes. Simply switch the meter on, dip into the sample and choose the measurement range. All readings are automatically compensated for temperature variations by 2% per ºC. is manual at a single point, choosing the buffer solution most suitable for your application. The probe is durable and has a removable plastic cover for easy cleaning. Range 0.0 to 199.9µS/cm, 0 to 1999µS/cm, 0.00 to 19.99mS/cm, 0.0 to 199.9mS/cm Resolution 0.1µS/cm, 1µS/cm, 0.01mS/cm, 0.1mS/cm, % ±1% full scale Single point via trimmer Temperature compensation Automatic from 10 to 40ºC with ß of 2% Probe 1m cable, 4-ring probe, for use across entire range Battery type/life 1x9V/100 hours use Environment 0 to 50ºC, RH 95% Dimensions, mm 143x80x38 Weight, g 360 223-058 HI-933000 compact conductivity meter with HI-76302W conductivity POA probe, cable, screwdriver, wrist-strap, 9V battery and manual 223-025 12880µS/cm, 460ml calibration solution POA 472-059 1413µS/cm, 460ml calibration solution POA 223-027 84µS/cm, 460ml calibration solution POA 223-028 80000µS/cm, 460ml calibration solution POA 667-103 Protective rubber holster POA 276

Bench Jenway, Models 4510 and 4520 Conductivity/TDS Meters Model 4510 A general purpose conductivity/tds/temperature bench meter for use in laboratory situations. The instrument includes a 32 reading memory facility. Ideal for routine laboratory applications Automatic temperature compensation Conductivity/TDS display 32 reading memory Automatic range selection RS232 serial interface on standard solutions or direct Analogue recorder output cell constant entry Wall mounting option Model 4520 A laboratory unit with more sophisticated features. Automatic range selection status and reminder Conductivity/TDS display 500 reading memory on up to 3 standard solutions or Comprehensive data logging options direct cell constant entry RS232 serial and IrDA printer interface ATC, including pure water temperature Alarm outputs compensation Analogue recorder output Security code protected user data Wall mounting option 223-004 Model 4510 4520 Conductivity Ranges 0 to 19.99µS/0 to 199.9µS/0 to 1999µS/ 0 to 19.99µS/0 to 199.9µS/0 to 1999µS/0 to 19.99mS/ 0 to 19.99mS/0to 199.9mS/0 to 1999mS* 0 to 199.9mS/0 to 1999mS/0 to 19.99S* *1999mS using X10 cell *19.99S using X10 cell Resolution 0.01µS/0.1µS/1µS/0.01mS/0.1mS/1mS* 0.01µS/0.1µS/1µS/0.01mS/0.1mS/1mS/0.01S* ±0.5% ±2 digits ±0.5% ±2 digits TDS Ranges 0 to 19.99mg/l /0 to 199.9mg/l/0 to 1999mg/l/ 0 to 19.99mg/l /0 to 199.9mg/l/0 to 1999mg/l/ 0 to 19.99g/l/0 to 199.9g/l/0 to 1999g/l* 0 to 19.99g/l/0 to 199.9g/l/0 to 1999g/l* *using X10 cell *using X10 cell Resolution 0.01mg/l to 1g/l 0.01mg/l to 1g/l ±0.5% ±2 digits ±0.5% ±2 digits Resistivity Range/Resolution 0 to 20MΩ/0.01MΩ Salinity Range/Resolution/ 0 to 99.9g/l/0.1g/l/0 to 35 ±1g/l/35 to 99.9±3g/l Temperature Range -10 to 105 C (14 to 221 F) -10 to 105 C (14 to 221 F) Resolution 0.1 C (1 F) 0.1 C (1 F) ±0.5 C (±1 F) ±0.5 C (±1 F) ATC range 0 to 100 C (32 to 212 F) 0 to 100 C (32 to 212 F) Manual TC range 0 to 100 C (32 to 212 F) 0 to 100 C (32 to 212 F) Cell constant 0.010 to 19.999 0.010 to 19.999 Temp. coeff. 0.00% to 4.00% 0.00% to 4.00% Ref. temp. 18, 20 or 25 C 18, 20 or 25 C EC ratio 0.50 to 0.80 0.50 to 0.80 1, 2 or 3 point 1, 2 or 3 point Auto std recog. 10µS, 84µS, 1413µS, 12.88mS 10µS, 84µS, 1413µS, 12.88mS Outputs Analogue/RS232 Analogue, RS232 serial & IrDA interface Clock 24 hours, hrs/min/sec or day of month/month/year, leap year corrected. GLP reminder interval (1 to 999 hours) Alarm outputs (open collector and audible). Security code protected user data Display 3 digit LCD Back lit 1/8 VGA monochrome LCD Languages English English, French, German, Italian, Portuguese and Spanish Power 9V power supply 9V power supply Dimensions, mm/weight, g 210x250x55/850 210x250x55/850 223-004 4510 Conductivity/TDS meter supplied with glass bodied conductivity cell with ATC K=1, electrode holder, power supply, condensed POA operating instructions and instruction manual. 223-008 4520 Conductivity/TDS meter supplied with glass bodied conductivity cell with ATC K=1, electrode holder, power supply, condensed POA operating instructions and instruction manual. For accessories see page 735. 277 New 223-008 New

Bench 223-002 Jenway, Model 3540 Conductivity and ph Meter The Model 3540 is ideal for use in water testing applications and in all laboratories where ph and conductivity analysis is required. The bright back lit LCD has five separate tabbed screens, each accessed with the simple navigation keys. The set-up menu gives quick and easy access to the wide range of instrument, ph and conductivity measurement options. of both the ph and conductivity channels is automatic, with the option to select 1, 2 or 3 calibration points for each. Automatically recognised ph buffers conforming to the NIST, DIN and JIS standards can be overridden by manually entered values, as can the 4 automatically recognised conductivity standards. An option to calibrate the conductivity channel to a cell constant is also included. The conductivity channel has a special ultra-pure water function which enables the ideal temperature compensation algorithm for this exacting application. Other modes of operation enable resistivity, salinity and TDS measurement. The ph channel can also display mv values to 0.1mV resolution, enabling ORP/Redox measurements to be made. The in-built data logger can store up to 250 ph and conductivity readings based on manual or automatically timed triggers, as well as from stability and alarm status. Logged results can either be sent to the internal memory or via the RS232 serial port to the optional printer. The comprehensive GLP functions include calibration reminders and status tracking, operator and sample ID management and a supervisor security code for all set-up options. Simultaneous display of ph and conductivity Two independent channels (e.g; ph and/or conductivity) Menu driven operation Datalogging with variable triggers Resistivity, TDS and Salinity modes Comprehensive GLP support Conductivity Range Auto ranging from 0.01µS to 1.999S (19.99S using X10 cell) Resolution 0.01µS to 1mS (0.01S using X10 cell) ±0.5% ±2 digits 1, 2 or 3 points Auto std recog. 10µS, 84µS, 1413µS, 12.88mS Manual std recog. Any value entered within the range or by cell constant value Reference temperature 18, 20, 25 C Temperature coefficient 0 (off) to 4%/ C ph Ranges -2.000 to 20.000 Resolution/ 0.001, 0.01, 0.1 selectable/±0.003 mv (Absolute or Relative) Range -1999.9 to +1999.9 Resolution 0.1 ±0.2 Input Impedance >10 12 ohms 1, 2 or 3 points Auto buffer recog. Jenway, NIST, DIN, JIS Manual buffer recog. Any value entered within the range Temperature (for each channel) Range -10 to 105 C (14 to 221 F) Resolution/ 0.1 C (1 F)/±0.5 C (±1 F) ATC range 0 to 100 C (32 to 212 F) Manual TC range 0 to 100 C (32 to 212 F) Outputs Analogue, RS232 serial and alarms Memory 250 reading (ph with conductivity) Clock 24 hours, hrs/min/sec or day of month/month/year, leap year corrected. GLP reminder interval (1 to 999 hours) Alarm outputs (open collector and audible) Security code protected - user and batch ID Display Back lit 1/8 VGA monochrome LCD Power 9V power supply (230V-110V mains adaptor) Dimensions, mm 210x250x55 Weight, g 850 223-002 3540 conductivity/ph meter supplied with glass bodied combination POA ph electrode, glass conductivity cell with ATC K=1, electrode holder, ATC probe, BNC shorting plug, 4, 7 and 10 ph buffer sachets, power supply, condensed operating instructions and instruction manual. 278

Bench Mettler Toledo, S30K and S70K Conductivity Meters S30K SevenEasy conductivity meter kit This new conductivity meter has four measurement modes: conductivity, resistivity, TDS and salinity. A cost effective solution for the workplace with built-in flexibility enabling it to be used as a portable or bench conductivity meter. Easy access keys and clear LCD displays the conductivity, temperature and standards used. Features include editable cell constant, automatic temperature compensation that can be switched on or off and self diagnostics for ease of use. RS232 interface for connection to PC or printer. Electrode arm that can be attached to the Selectable reference temperature 20 or 25 C meter or stand-alone Manual and auto read Auto buffer recognition Reading stable/ready indicator Linear and non-linear correction Editable cell constant S70K SevenMulti conductivity meter kit The S70 provides reliable conductivity measurement from routine analyses through to the most demanding applications. A new user-friendly instrument featuring an on-line user help screen for quick reference and hot keys for easy operation. Optional expansion units make it possible to measure ph, conductivity, ISE and ISFET using one meter. Comprehensive GLP support with features including: password protection; graphical display of calibration curve; last 10 calibrations with date and time and calibration reminder. In addition to the features listed for S30K model the S70K also features: Display of last 25 readings Memory for 10 methods and 1000 measured values Alphanumeric input of meter ID, user name, sample ID, serial no. User defined high/low limits Timed interval reading, output of readings to printer/memory at defined intervals USP mode, compliance with latest standards for ultra pure water, USP <645> stages 2 and 3 223-098 279 New 223-099 New Model S30K S70K Conductivity measurement Range 0.1µs/cm 500mS/cm (auto-ranging) 0.01µs/cm 1000mS/cm (auto-ranging) Resolution/ 2 decimal places/±0.5% 2 decimal places/±0.5% Total Dissolved Solids measurement Range 0.1mg/l 2000g/l 0.1mg/l 2000g/l Resolution/ 2 decimal places/±0.5% Adjustable solids factor 2 decimal places/±0.5% Adjustable solids factor Temperature measurement, C Range/Resolution/ -5.0 to 105/0.1/±0.1-5.0 to 130/0.1/±0.1 Salinity 0.00 80.00 ppt (parts per thousand) 0.00 80.00 ppt (parts per thousand) Resistivity 0.00 20 Mega Ω cm 0.00 20 Mega Ωcm points 1 of 3 (84µS/cm, 1413µS/cm, 12.88mS/cm) 1 of 4 (84µS/cm, 1413µS/cm, 12.88mS/cm, sat NaCl) & user defined Cell constant Editable Input, edit and recall Inputs Mini-DIN, power, RS232 Mini-DIN, titrator output, power, RS232, analogue output Power Mains (9V DC) or 4 x AA batteries Mains (9V DC) Dimensions (wxdxh), mm 180x180x65 190x240x65 Weight, g 610 850 (+135g for one expansion unit - supplied)* * Plus 135g for each expansion unit 223-098 S30K SevenEasy conductivity meter with Inlab 730 conductivity electrode, electrode arm, conductivity standards (2x 1413µS/cm POA and 2x 12.88mS/cm), guide to conductivity measurement booklet, protective cover and meter test certificate 223-099 S70K SevenMulti benchtop conductivity meter. Supplied as above POA For S70K SevenMulti conductivity meter 474-276 ph expansion unit POA 474-279 ISFET expansion unit POA 474-278 ISE expansion unit POA 474-283 Replacement protective cover POA For S30K and S70K conductivity meters 474-268 InLab 710 conductivity probe (4 plate glass for 0.01 500mS/cm) POA 474-284 Electrode arm assembly POA 474-267 InLab 720 conductivity probe (2 plate glass for 0.1 500µS/cm) POA 130-150 RS-P42 Printer (requires RS232 cable) POA 474-281 InLab 730 conductivity probe (0.01 1000mS/cm) POA 474-108 RS232 cable for PC/RS-P42 printer POA 474-280 Flow cell for use with Inlab 740 and Inlab 720 (reduces CO2 absorption) POA 474-265 Balance link software (requires RS232) POA 474-282 InLab 740 conductivity electrode pure water applications POA (SevenEasy only) USP (steel, 0.001 500µS/cm)* 474-240 Temperature probe (NTC30K) POA * For USP, ultra pure water applications order Inlab 740 conductivity electrode, supplied with a certificate that states the cell constant of each individual probe.

Bench New 223-083 Hanna, HI-2300 Extended Range Bench Conductivity/TDS/Salinity/ C Meter An extended range microprocessor conductivity meter, which also reads TDS, NaCl and temperature. All measurements are taken with just one probe with readings displayed on a large LCD screen. With improved resolution and accuracy the meter can read from de-ionised water to seawater, automatically switching ranges to the scale with the best resolution. Other features include: Automatic calibration with six pre-programmed buffers Automatic temperature compensation with optional manual or nil compensation for actual conductivity readings Adjustable temperature coefficient Adjustable EC and TDS factor GLP features RS232 interface Two year meter guarantee Supplied complete with probe on 1m of cable, probe stand and power adaptor. Model Range Resolution Conductivity 00.0 to 29.99/30.0 to 299.9/300 to 2999 µs/cm 0.01/0.1 ms/cm 3.00 to 29.99/30.0 to 200.0 ms/cm 0.01/0.1/1 µs/cm Actual conductivity Up to 500.0 ms/cm actual conductivity* TDS 0.00 to 14.99/15.0 to 149.9 /150 to 1499 mg/l (ppm) 0.01/0.1/1 ppm 1.50 to 14.99/15.0 to 100.0 g/l (ppt) 0.01/0.1 g/l Actual TDS Up to 400.0 g/l (ppt) actual TDS* (with 0.80 factor) NaCl 0.0 to 400.0 % 0.1 % Temperature 0.0 to 60.0 C 0.1 C EC ±1% of reading ±(0.05 µs/cm or 1 digit, whichever greater) TDS 1% of reading ±(0.03 ppm or 1 digit, whichever greater) NaCl ±1% of reading Temperature ±0.4 C EC 1 point with 6 memorized buffers: 84, 1413, 5000, 12880, 80000 or 111800 µs/cm NaCl 1 point with optional buffer (223-090) Temperature 2 points at 0 and 50 C (plus ±1 C adjustment) Temp. compensation Automatic or Manual from 0 to 60 C (can be disabled to measure actual conductivity) Temp. coefficient 0.00 to 6.00 %/ C (for EC and TDS only) Default value is 1.90%/ C TDS factor 0.40 to 0.80 (default value is 0.50) Probe HI-76310 Platinum 4-ring probe, K=1 nominal and built-in temperature sensor (included) GLP Storing of last calibration data Serial interface RS232 - downloading of last calibration data Power supply 12 VDC adaptor (included) Auto off After 5 minutes (can be disabled) Environment 32 to 122 F (0 to 50 C); 95% RH non-condensing Dimensions (lxwxd), mm 230x170x70 Weight, kg 1.2 * Actual conductivity (or TDS) is the non-temperature compensated conductivity (or TDS) value of a solution. 223-083 HI-2300 Extended range bench conductivity/tds/salinity/ C meter with probe, POA probe stand and mains power adaptor. 223-027 84µS/cm, 460ml calibration solution POA 472-059 1413µS/cm, 460ml calibration solution POA 223-025 12880µS/cm, 460ml calibration solution POA 223-090 100% NaCl sea water solution, 230ml POA 472-145 Windows software POA 472-146 RS232 connection cable POA 280

Bench Hanna, EC-214 and EC-215 Bench Conductivity Meters Two easy to use bench conductivity meters with temperature compensation. The EC-214 compensates manually and the EC-215 automatically and both can be calibrated with a wide range of calibration solutions. Both meters cover four measurement ranges reading from de-ionised water to brine using just one probe. Supplied with EC probe and mains power transformer. Model EC-214 EC-215 Ranges 0.0 to 199.9µS/cm, 0 to 1999µS/cm, 0.00 to 19.99mS/cm, 0.0 to 199.9mS/cm (both models) Resolution 0.1µS/cm, 1µS/cm, 0.01mS/cm, 0.1mS/cm (both models) ±1% full scale (both models) Manual 1 point (both models) Temperature compensation Manual from 0 to 50 C Automatic from 0 to 50 C Dimensions (lxwxd), mm 240x182x74 (both models) Weight, kg 1.0 (both models) 223-081 EC-214 Bench conductivity meter with probe and mains power transformer POA 223-082 EC-215 Bench conductivity meter with probe and mains power transformer POA for EC-214 and EC-215 472-148 Electrode holder POA 472-059 1413µS/cm, 460ml calibration solution POA 223-027 84µS/cm, 460ml calibration solution POA 223-025 12880µS/cm, 460ml calibration solution POA Laboratory Conductivity Cells Supplied with 1 metre of cable. Models K20, K21, K22 and K25 are glass free. Type K25 is 4 ring. The temperature range of all cells is 0ºC to 50ºC. When ordering conductivity cells please specify make and model of conductivity meter. These cells do not have an internal ATC, although this is available as an option. Please specify when ordering. 223-082 Cat. No. Model Range Body Plate Dims. Cell Application Price Type Material mm Constant 223-059 K10 0 to 150mS Glass Pt 120x12 K=1 General POA 223-060 K20 0 to 10mS Epoxy Carbon 100x12 K=1 Paints, inks, POA dyes, foodstuffs 223-061 K21 0 to 500µS Epoxy Carbon 120x12 K=0.1 Pure water POA 223-062 K22 0 to 0.5S Epoxy Carbon 120x12 K=10 Solutions with POA high conduct. 223-063 K25 0 to 1S Epoxy Carbon 120x12 K=0.55 Aqueous/ POA non aqueous 223-064 K30 0 to 150mS Glass Pt 120x12 K=1 Flow through POA 223-065 K40 0 to 500µS Glass Pt 120x12 K=0.1 Pure water POA Note: When ordering conductivity cells please specify make and model of conductivity meter. 281