SOLAR THERMAL CONTROL OF BUILDING INTEGRATED PHASE CHANGE MATERIALS: AN EXPERIMENTAL SURVEY

Similar documents
MICROENCAPSULATED PHASE CHANGE MATERIALS (PCM) FOR BUILDING APPLICATIONS

Use of Microencapsulated Phase Change Materials in Building Applications

Adaptive strategies for office spaces in the UK climate

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling

Studies energy efficiency of the renewable sources use considering climate in Latvia

PHASE CHANGE MATERIAL AS A THERMAL ENERGY STORAGE MATERIAL FOR COOLING OF BUILDING

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

New Thermal Architecture For Future Green Data Centres

Heat and cold storage with PCM

SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.

Outline. Thermal storage for low carbon buildings. Effect of global warming on design summer year. Environment impacts of buildings

Energy Efficiency in Buildings

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov to Mar. 15, 2004.

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Software Development for Cooling Load Estimation by CLTD Method

CONDENSATION IN REFRIDGERATED BUILDINGS

Thermal testing and numerical simulation of a prototype cell using light wallboards coupling vacuum isolation panels and phase change material

IES <Virtual Environment> Tutorial. Apache Sim (Version 6.0)

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

CFD Analysis of Application of Phase Change Material in Automotive Climate Control Systems

Passive Solar Design and Concepts

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Investigation into the energy consumption of a data center with a thermosyphon heat exchanger

18th International Congress of Mechanical Engineering

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

CHAPTER 11: PASSIVE SOLAR HOMES

Heating Load Calculation

The Influence of Insulation Styles on the Air Conditioning Load of Japanese Multi- Family Residences

EXPERIMENTAL INVESTIGATION OF A BIO-BASED PHASE-CHANGE MATERIAL TO IMPROVE BUILDING ENERGY PERFORMANCE

Calculation of Liquefied Natural Gas (LNG) Burning Rates

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls

THERMAL STORAGE WITH PCM VS. THERMAL INSULATION IN WARM AND HOT CLIMATES

ResearcH JournaL 2009 / VOL

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

THERMAL LOSSES Thermal Losses Calculations

IMPROVING CALCULATIONS OF BUILDING ENERGY CONSUMPTION BASED ON TEN YEAR MEASURED DATA

Comments on How Exterior Paints and Interior Paints Can Play Roles in Conserving Energy. For Tech Traders Inc. By H. F. Poppendiek

Experimental study of a parabolic solar concentrator

Solar Energy Utilisation in Buildings

Application of latent heat thermal energy storage in buildings: State-of-the-art and outlook

The Influence Of Window Type And Orientation On Energy-Saving In Buildings Application To A Single Family Dwelling

An Experimental Study of the Sound Insulation Performance and Sound Defect Using Sound Intensity According to the Composition of Balcony Windows

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Residential HVAC System Sizing

Introduction to Energy Performance of Brick Masonry

HVAC Calculations and Duct Sizing

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

NEW TEXTILE COMPOSITES WITH THERMO-REGULATING PROPERTIES FOR AUTOMOTIVE INTERIOR APPLICATIONS

) and air spaces (R a

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

A comparative study of the thermal performance of reflective coatings for the urban environment

Windows are one of the most important components of a

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Long-Term Hygrothermal Performance of Green Roofs

Rockwool Flexi Insulation Application Guide

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

Micronal PCM. Intelligent Temperature Management for Buildings. A broader base for your success.

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS

Experimental Study of Free Convection Heat Transfer From Array Of Vertical Tubes At Different Inclinations

MIT Manufacturing Processes and Systems. Homework 6 Solutions. Casting. October 15, Figure 1: Casting defects

Module 3.7. Thermal bridging

HEATING-COOLING WALL PANELS SYSTEM IN SLOVENE ETHNOGRAPHIC MUSEUM

Optimal Drying of Flooded Brickwork Masonry

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):

Distance Staff Cooperation in On-Line Engineering

Green House, Hungary

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

Design and Re-Use Of Shovadans In Today's Architecture "With Due Attention To Have Thermal Energy Of The Earth"

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

Heat Pipe Cooling of Concentrating Photovoltaic (CPV) Systems

EXPERMENTATIONAL DATA ANALYSIS OF CHIMNEY OPERATED SOLAR POWER PLANT

CO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Improving thermal insulation of concrete sandwich panel buildings

Natural Convection. Buoyancy force

Integrated Solar Radiant Systems

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Models and Methods in Applied Sciences

A Study of the Energy-Saving Potential of Metal Roofs Incorporating Dynamic Insulation Systems

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

Transcription:

IJRET: International Journal of Research in Engineering and Technology eissn: 2319-1163 pissn: 21-738 SOLAR THERMAL CONTROL OF BUILDING INTEGRATED PHASE CHANGE MATERIALS: AN EXPERIMENTAL SURVEY A. Mourid 1, M. Faraji 2*, M. El Alami 3, M. Najam 4, F. Berroug 5 1,2,3,4 Hassan II University, Faculty of Sciences Ain Chock, Physics Department, LPMMAT Laboratory, Casablanca- Morocco 5 Cadi Ayyad University, Faculty of Sciences Semlalia, Physics Department, LAEPT Laboratory, Marrakech- Morocco (*) Corresponding author Email: farajimustapha@yahoo.fr, phone: +212 63175699 Abstract In the present paper, we study experimentally the thermal behavior of phase change material (PCM) for thermal control of indoor applications. The experimental setup consists of two full scale identical concrete cavities, situated in Faculty of Sciences Aïn Chock in Casablanca- Morocco (33 36'N, 7 36'W). The first cavity incorporates paraffinic phase change material with melting temperature of 22 C and second cavity is built with alveolar bricks. The test cells are equipped by set of thermocouples and heat flux meters connected to data logger. Thermal analysis for the two cubicles was conducted. The results show that inner temperature swings decreases remarkably in the cavity with PCM with temperature minima 3 C upper to the case without PCM. On the other hand, there is time shift between PCM cavity and the reference cavity temperature oscillations. The integration of the phase change material on the roof of the building reduces the temperature of internal walls as it has good thermal inertia. When PCM panel covered the roof, solar heat transmission is reduced. This significantly reduces the ambient temperature of the cell. This demonstrates the ability of PCM to increase the thermal comfort of buildings. Keywords: PCM, Thermal Comfort, Building, Passive Solar Heating, Heat Storage. Melting, Solidification --------------------------------------------------------------------***---------------------------------------------------------------------- 1. INTRODUCTION Energy consumption for the air conditioning inside the housing is becoming increasingly important for the modern buildings. This type of construction generally uses lightweight materials, low heat storage capacity, which usually requires the use of artificial air conditioning. To improve the thermal performance of the habitat in a passive way, different types of phase change materials are used: inorganic, organic and eutectic. These PCMs are incorporated into different components of construction: walls, slabs and floors. Phase change materials (PCM) can be used in building using solar energy for heating or night cold for cooling. During the process of melting and solidification of the PCM incorporated in building structure, a large amount of energy can be absorbed or released over a very small temperature range, enabling PCM to act as a heat reservoir nearly isothermal. Selecting PCM essentially concerns its melting temperature, its latent heat capacity and cost. Different types of PCMs and their characteristics are described in literatures. Paraffin-based PCMs are commonly used in buildings because of their appropriate melting temperature, their large capacity for latent heat, stable chemical properties, nontoxicity and low cost. One concern of using paraffin in building constructions is its flammability. The wallboards are cheap and widely used in a variety of applications, making them very suitable for PCM encapsulation. However, the principles of latent heat storage can be applied to any appropriate building materials. The idea of improving the thermal comfort of lightweight buildings by integrating PCMs into the building structure has been investigated in various research projects since before 1975 by Barkmann et al. 1, Kedl et al. 2 and Salyer et al. 3, Shapiro et al. 4,5 and by Feldman et al. 6. Most of these attempts applied PCM macrocapsules or direct PCM immersion processes. PCMs have been incorporated into gypsum wallboards to provide passive energy storage. For integration into the walls, the PCM layer may be sandwiched between the inner and outer walls, absorbed in porous concrete, or impregnated plasterboard 7,8. Faraji et al. 9 performed a numerical study of the thermal performance of a concrete/paraffin/hydrate salt composite wall used for heating management of building. The solar energy absorbed by the wall is stored in a phase change material (PCM). It was found that, when the PCM layer is set closer to the inner face of the wall, thermal comfort conditions are considerably improved compared to a concrete wall without PCM. Castell et al. 1 obtained energy consumption reductions of 15 % when PCM was implemented in building envelopes. The objective of the present work is to evaluate the thermal performance of envelope of residential buildings equipped with a phase change material. An ordinary test cavity has been used as a reference. The field trials were carried out with two identical cells. The PCM was installed on the roof and/or in vertical walls. The thermal performance of the walls was compared with those of the reference cell by measuring their conductive heat flux, internal walls temperatures and cells ambient temperatures. Volume: 5 Issue: 2 Feb-216, Available @ http://www.ijret.org 188

IJRET: International Journal of Research in Engineering and Technology eissn: 2319-1163 pissn: 21-738 full scale cubicles with the same internal dimensions (2.8x2.8x2.8 m), equipped with glazed window (1x1 m) and a door (2x1 m), in the north wall. The constructive systems of these rooms are: - Reference cubicle: built with alveolar bricks system based on two layers of bricks as follows: 2 cm mortar, 7 cm red bricks, 14 cm air gape, 7 cm red bricks and 1 cm mortar, successively. The roof was built by full paving stone concrete. - PCM cubicle: built as the previous cubicle adding a PCM panels in the inner faces of the vertical walls and on the roof. PCM consist of Energain paraffin panels, Figure 1-c. Fig 1. (a) Fig 1. (b) 2.2. Phase Change Material (PCM) The phase change material used is Rubitherm-Energain, product manufactured by Dupont de Nemours Company (Luxembourg). This PCM is a rectangular panel with dimensions of 1x1.2 m and embedded in a thin aluminum cover. The shape of the PCM material is flexible aluminum sheet of 5. mm, Figure 1 (c). The panel contains 4 % of solid compound (copolymer ethylene) and 6 % of paraffin. It is characterized by a melting temperature of 21.7 C and an enthalpy of 7 kj/kg. The thermal conductivity is.18 Wm - 1.K -1 in solid phase and.14 Wm -1.K -1 in liquid phase. Rubitherm-Energain PCM was selected to be used in the cubicle because it store and release large quantities of thermal energy at nearly constant temperature, The use of one Energain panel of 5 mm thickness is equivalent to 3 mm of concrete. It is chemically inert, long life product and stable performances during phase change cycles also, the melting temperature is close to human comfort. Table 2 summarizes the main thermal properties of the PCM. Table 1 summarizes the geometrical dimensions of the cubicle walls. Fig 1. (c) Figure 1: Experimental setup full scale size: cubicles construction stages (a) under building, (b) finish. (c) PCM panels. Table 1: Envelop materials (from interior to exterior) (a), Vertical walls thermal properties (b), Roof structure and materials properties (c) Wall Material Thickness(mm) Roof Mortar 2 Concrete 12 Mortar 2 Vertical wall PCM 5. Air layer 14 Mortar 1 Brick 7 Air layer 14 Brick 7 Mortar 1 Floor Mortar 1 Plaster 5 Concrete 1 2. EXPERIMENTAL FACILITY Calc 3 2.1. Experimental setup Glazed Glass 3 façade Figure 1-a,b shows the experimental setup located in (a) Casablanca, Morocco (33 36'N, 7 36'W). It consists of two Volume: 5 Issue: 2 Feb-216, Available @ http://www.ijret.org 189

Temperature( C) Solar radiations W/m2 IJRET: International Journal of Research in Engineering and Technology eissn: 2319-1163 pissn: 21-738 Mortar Alveolar Air Alveolar Mortar e (cm) 1 7 14 7 1 c p (kj/kg.k).84.79 1.23.79.84 λ (W/m.k) 1.15.47.9.47 1.15 (b) Mortar Full paving concrete(roof) e (cm) 2 15 c p (kj/kg.k).84.92 λ (W/m.k) 1.15 1.75 (c) 2.3. Instrumentation and Measurements The cells are instrumented with 75 thermocouples K-type (2/1 mm) with an accuracy of ±2%. They are carefully welded, ensuring that the weld is of the same diameter that the two wires. Then, they are calibrated and the assembly is connected to a data acquisition device, Figure 2-a. Note that the thermocouples are distributed in order to access to the average temperatures of all the walls and the indoor temperature of the cells. We have also conducted heat flux density measurements through the walls of the room with heat flux captors, Figure 2-b, having an accuracy of ±3 % and a.3 s response time. The considered case is a room with one person and personal computer, corresponding to 3 W internal gains 11. Are registered with 1 minutes frequency: - Internal walls temperatures and also external temperature. - Internal ambient temperature (at a height of 1.5 m). - Heat fluxes at the cubicles faces. 2.4. Meteorological Data The experiments were carried out for free external radiations and temperature conditions during March and August 214. Meteorological station, fixed on the roof of the test cells, was used to register the outdoor ambient temperature, solar radiation, wind velocity and wind direction and relative humidity. All data are stored in a desk computer using data logger. 3. RESULTS AND DISCUSSION The results from the experimental test in the cubicles with and without PCM were obtained from 214 during the periods of Mars, 9 to 13: heating period, and August, to 31: air refreshing period. 3.1. Heating Period: PCM in Vertical Walls Figure 3 analysis shows that minimum outdoor temperatures are obtained during the night. On average, temperatures minima and maxima range between 1 C and 23 C, respectively, and the ambient temperature swings between these extremes. During the first 7 hours every day, solar radiations rises and the ambient outdoor temperature increases. Solar radiation reaches a maximum value, 72 W/m 2 and falls to zero at the sunset. Casablanca city climate is characterized by significant temperature fluctuations with lower nocturnal values of temperature. None controlled building will demand more energy for heating purpose. 34 3 Solar radiations 8 7 24 22 2 18 16 14 6 5 4 3 2 (a) Figure 3: Time wise variations of the external ambient temperature and solar radiations, (Casablanca, Morocco 33 36'N, 7 36'W) Table 2: Thermal properties of the Energain PCM 12 Parameter Value Melting point 21.7C Combined Heat storage capacity (latent and >17 sensible heat in a temperature range of 14 to kj/kg 29 C) Specific heat capacity >7 Conductivity - solid phase Conductivity - liquid phase kj/kg K.18 W/m K.14 W/m K (b) Figure 2: Thermocouples and Data Acquisition System (a). Heat flux sensor (b) Volume: 5 Issue: 2 Feb-216, Available @ http://www.ijret.org 19 12 1 1

Temperature( C) Heat flux (W/m2) Temperature( C) IJRET: International Journal of Research in Engineering and Technology eissn: 2319-1163 pissn: 21-738 34 With PCM 3 24 22 2 18 16 14 12 1 8 6 4 2 Figure 4: Time wise variations of the external ambient temperature and south walls temperature for cubicles with and without PCM, (Casablanca, Morocco 33 36'N, 7 36'W) Figure 4 shows the time variations of the temperature of south wall of both cubicles. Data analysis shows that the thermal reduction is slower in the PCM cubicle case, since it has stored more heat (latent) during a day. Remember that ambient temperature vary between 1 C to 23 C, but the building walls receive also solar irradiative heat flux absorbed by the concrete having solar absorption coefficient of.8, combined with internal loads and convective heat flux. A thermal gain leads to the increase of the PCM temperature to its melting point. During the night, when the PCM undergoes phase change, the slop of PCM wall temperature curve weakens because the solidification of PCM occurs at a nearly constant temperature. Sensible heat dissipation is disabled and the decrease of the PCM cubicle nocturnal temperature is shifted. Composite PCM-Concrete walls can be considered as an important heat storage device. The stored heat during a day is naturally released for heating needs in the following cold night with less temperature fluctuations. 33 With PCM 31 3 29 27 Figure 5: Outdoor and indoor ambient temperatures for cubicles with and without PCM on the roof 3.2. Refreshing Period: PCM on the Roof In order to minimize heat gain in the summer, PCM panels were placed on the roof of the test cell. The flow to be transmitted by conduction to the inside will be converted by the PCM as latent heat of fusion. To demonstrate this process, we will compare the internal ambient temperature of the PCM room to those of the reference room. The results were obtained from to 31 August 214. Figure 5 sketches the experimental result according to the indoor ambient temperatures for cubicles with and without PCM on the roof. It was emerged that, the inner ambient temperature of the cell without PCM is practically identical with the outside temperature because of low thermal inertia of local. For the case of cubicle with PCM roof, the room has good thermal inertia and PCM contributes to refresh the air and an inner temperature is decreased about 2 C, because that, during the melting of the PCM, sensible heat gain is disabled and the increase of the PCM cubicle diurnal temperature is shifted. During the night, the cancelation of solar radiations and the fall of the external temperature promote the freezing of PCM. Also, sensible heat accumulated during the hot day is released to the exterior and to the PCM at nocturnal phase. An important amount of cold is stored in the crystallized PCM at night and will be used passively to refreshing the room during the following day. -1 Figure 6: Evolution of conductive thermal gradients via the cubicles south wall Figure 6 represents the conductive thermal gradients via the south walls. It is found that the heat flux exchanged by conduction through this wall is very important in the PCM cell. Indeed, there are very significant reductions in solar energy gain through the ceiling with PCM. This significantly reduces the ambient temperature of the cell as shown in Figure 5, which causes an increase in heat flow through the vertical walls. The heat flux flow reaches 2.5 W/m 2 in the reference and cell exceeds 4 W/m 2 in the PCM cell. In the case of roof with PCM thermal gradient can be negative at night because the indoor air remains warmer than the outdoor. 4. CONCLUSION Experimental investigation of the thermal performance of composite concrete/pcm cubicles constructed within the Faculty of Science Ain Chock in Casablanca city, Morocco, equipped with a phase change material, in vertical walls and on the roof, was performed. The results showed a significant Volume: 5 Issue: 2 Feb-216, Available @ http://www.ijret.org 191 4.5 4 3.5 3 2.5 2 1.5 1.5 -.5 With PCM

IJRET: International Journal of Research in Engineering and Technology eissn: 2319-1163 pissn: 21-738 reduction of indoor temperature fluctuations due to absorption and release of solar gains in the composite wall in conjunction with melting of the PCM. The results showed that thermal load of the cubicle containing PCM was reduced compared to the case without PCM with more constant conditions during the heating period. This study showed also that the integration of PCM in the roof lowers the temperature of inner side walls and reduces the amplitude of the oscillations of the temperature of about 2 C during the air refreshing period. It was emerged that the cubicle with PCM/concrete walls is able to provide good performance. The thermal conditions of the indoor environment achieved with the presence of PCM panels were considerably improved compared to cubicle without PCM. solutions for passive cooling. Energ Buildings 21;42:534-54. ASHRAE. (29). 29 [11] ASHRAE Handbook - Fundamental(SI), http://www.techstreet.com/ashrae /products/1858361?ashrae_auth_token=. [12] Rubitherm Technologies GmbH, Internet: www.rubitherm.com, Data sheet, Date: 23.7.213. ACKNOWLEDGEMENT The present work was financially supported by the Innotherm R&D project IRESEN-Morocco. REFERENCES [1] H.G. Barkmann, F.C. Wessling, Use of building structure components for thermal storage, Processing of the Workshop on Solar Energy Storage Subsystems for Heating and Cooling of Building, Charlottesville, VA, USA, 1975. [2] Kedl RJ, Stovall TK, Activities in support of the waximpregnated wallboard concept. Thermal energy storage researches activity review. New Orleans, Louisiana, USA: US Department of Energy; 1989. [3] Salyer IO, Sircar AK. Phase change material for heating and cooling of residential buildings and other applications. In: Proceedings of 25 th intersociety energy conservation engineering conference; 199. p. 236 243. [4] Shapiro MM, Feldman D, Hawes D, Banu D. PCM thermal storage in wallboard. In: Proceedings 12th passive solar conference, Portland; 1987. p. 48 58. [5] Shapiro M. Development of the enthalpy storage materials, mixture of methyl stearate and methyl palmitate. Subcontract report to Florida Solar Energy Center; 1989. [6] Feldman D, Khan MA, Banu D. Energy storage composite with an organic phase change material. Solar Energy Mater 1989;18:333 41. [7] Li. B. Z, Zhang C.L, Deng A. Study on improving indoor thermal environment in light weight building combining PCM wall and nighttime ventilation. Journal of Civil Architectural & environmental Engineering 31(3) 29. [8] J.Paris, Villain, J.-F Houle. Incorporation of PCM in wallboards: a review of recent developments. In: Proceedings of the First World Renewable Energy Congress, September, Reading, UK, pp. 2397 241, 199. [9] M. Faraji, Numerical computation of solar heat storage in phase change material/concrete wall. International Journal of Energy and Environment, vol 5, (3).353-36,214. [1] Castell A, Martorell I, Medrano M, Pérez G, Cabeza LF. Experimental study of using PCM in brick constructive Volume: 5 Issue: 2 Feb-216, Available @ http://www.ijret.org 192