Power Distribution Solutions for the Data Center Equipment Cabinet THE WORLD LEADER IN POWER MANAGEMENT PRODUCTS & SOLUTIONS



Similar documents
How do I... POPS Smart & Switched CDU. If you manage a datacenter, we have a solution for you.

Server Technology, Inc.

One unbelievable solution for rack-level data center power management. Sentry Power Manager. Solutions for the Data Center Equipment Cabinet

Includes customer case study. February 28, 2013

CenterMind P+ Solution for efficient power management

PN5212/PN5320/PN7212/PN7320

Eaton epdu. Intelligent and flexible power distribution

PE6108/PE6208/PE8108/PE8208

CS-24HEK4B3H2 (Master) CL-24HEK4B3H2 (Expansion) Key Features. Inputs

INFRASTRUCTURE FOR DATACENTERS

Energy Management Solutions

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

Who do the biggest names in servers, search, healthcare, cloud & financial services trust to provide power management solutions?

Server Technology, Inc.

Server Technology, Inc.

Integrated Wire-Free Solution for Monitoring Power and Environment with RF Code and Sentry Power Manager (SPM)

PE8216/PE8324. Energy Intelligence Solutions

Rack Power Distribution

Power & Environmental Monitoring

Rack Power Distribution. Worldwide

Power Commander Power Distribution Units from Wiremold/Legrand offer

How To Power A Bladecenter H Servers

Intelligent Power Distribution in the Data Center

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring

Dominion PX. General Questions. What is Dominion PX (PX)?

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

Introducing Tripp Lite s PowerAlert Network Management Software

TSM Series Serial Console Servers. RSM Series Remote Site Managers. RSM-xRy Series Remote Site Managers with Power Control.

Uninterruptible Power Supply

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

DS Series Solutions Integrated Solutions for Secure, Centralized Data Center Management

INTELLIGENT & BASIC POWER DISTRIBUTION UNITS (PDU)

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

M O N I T O R I N G S O L U T I O N S INFRASTRUCTURE MANAGEMENT SOLUTIONS. Varicontrol-P. The Integrated Rack Management System

ED1259R5 Updated April 2011 For latest specs visit

Power Management. Raritan Description.

HP UPS Management Module Overview

Network Management Card. User Manual

Panduit Infrastructure Management Software for Data Centers and Enterprises

Remote Site Management Solutions

Packet Power. Data Center Solutions. Packet Power. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution

Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning

Centralized Orchestration and Performance Monitoring

The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access

Technical Overview CM-16 Climate Monitor. Get yours direct at:

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

Cisco Nexus 7000 Series Power Supply Modules

Network Power Manager. User Manual

Power Distribution Considerations for Data Center Racks

CenterMind P+ Intelligent Power Management for your Data Center

Ahead in power distribution

Technical Overview CM-2 Climate Monitor. Get yours direct at:

For the protocol access paths listed in the following table, the Sentry firmware actively listens on server ports to provide security for the CDU.

QuickSpecs. Models. HP UPS Management Module. HP UPS Management Module. Overview

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

User s Manual Network Management Card

Rack Power Distribution For Critical IT Equipment More efficient Simpler Better

Power IQ User Guide Release 2.0.0

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Distributing Power to Blade Servers

Data Center Power Distribution at the Cabinet Level: The top 12 questions you need to ask to improve data center energy effciency

Version Filename Part Number Opcode V_ FL bin FL bin.md5 FL pkg

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

How to Set Up Your NSM4000 Appliance

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Understanding DRAC/MC Alerts

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Olson Electronics Remote Power Monitoring Meter

EO and Smart Federal Government Data Center Management

Computer Cabinet Environment Monitor

Energy Communication Unit (ECU)

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

MSNswitch: 1. Automatically Power-Cycle Unresponsive Network Devices 2. Watch-Dog for Network Devices

RuggedCom Solutions for

NMS300 Network Management System

Rack Power Distribution Unit For Critical IT Equipment

Server Remote Control External KVM over IP. StarTech ID: SV1110IPEXT

securityprobe 5E Standard

scalable data centre energy management solution

Smart-UPS On-Line 230 V

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Communication and connectivity the ideal solution for integrated system management and data integrity

Transcription:

> POWERSOLUTIONS

CDU Product Family Power Distribution Solutions for the Data Center Equipment Cabinet THE WORLD LEADER IN POWER MANAGEMENT PRODUCTS & SOLUTIONS Cabinet power distribution units and power monitoring and measurement solutions for data centers and telecommunications. Saifor distributes CDUs from Servertech that is experts produce the highest quality rack mount power distribution and monitoring solutions that help manage power capacity, reduce downtime and improve energy efficiency. Server Technology created the intelligent cabinet PDU market and holds the largest number of patents in that industry. Serving the Data Center and Carrier markets, SAIFOR includes among its solutions, the most extensive selection of Sentry CDUs to manage power usage for servers, storage and network equipment. Based on the innovative Server Tech Quality Power Architecture (QPA), Sentry CDUs and Sentry Power Manager provide the industry s most accurate information to maximize rack density, reduce overloading and monitor energy efficiency. All Sentry CDUs offered by SAIFOR are engineered and manufactured to meet the highest quality standards and are100% performance tested for reliability and accuracy. Server Tech QPA eliminates single points of failure, reducing downtime and costs. The modular architecture is flexible and enables quick delivery of solutions that meet customer-specific requirements. SAIFOR solutions gives IT and Infrastructure Professionals the control to make accurate capacity planning decisions, reduce risks, and meet energy efficiency goals. CERTIFICATIONS, COMPLIANCE & WARRANTY All products contained within this brochure carry one or more of the certifications below. Additional agency certifications are available based on specific market requirements. > European Union (TUVGS mark) to EN 60950-1:2001 > EMC EN 55022 Class A, EN 55024 > RoHS > CE > 2 Year Warranty FEATURE KEY Sentry CDU product lines feature two or more of the following assets: Flexible mounting options Zero-U button or bracket mounting for mounting vertical CDUs in the back or on the side of the cabinet to avoid consuming valuable U space. Branch circuit protection All Sentry CDUs meet the UL 60950-1 requirement for branch circuit protection and use either fuses or circuit breakers to protect each branch of outlets. Input current monitoring The CDUs exclusive True RMS Current Monitoring is critical to preventing overloads in high-density computing environments. Digital LED displays on the CDU enclosure report the input current of each phase or branch circuit. Environmental monitoring External probes, with 3-meter cable, capable of measuring temperature & humidity. Receive SNMP-based or email alerts when conditions exceed defined thresholds. Expansion module Our exclusive method for linking additional outlets, on separate CDUs, together under a single IP address, and provides support for A & B power in-feeds. IP access, security & communications Web interface, SSL, SSH, Telnet, SNMP & RS-232 access, 10/100 Base T-Ethernet, SSLv3/TLSv1, SNMPv2, TACACS+, LDAP, LDAPS, RADIUS, DHCP, SMTP/Email, & Syslog. Individual outlet control Control individual outlets or groups of outlets with ON, OFF, and Reboot functionality to remotely reboot unresponsive servers and network equipment. Pops (Per outlet power sensing) Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor and Power Factor per outlet. Pips (Per inlet power sensing) Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Reactance, Accumulated Energy (kwh), and Power Factor per inlet. Cable retention clip Ensures power cords to the connected devices are not accidently unplugged or disconnected. 2

CDU Product Family Sentry CDU Family Delivers Power Solutions for any Data Center Basic CDU The entry level Basic CDU products provide reliable power distribution and branch circuit protection for all the devices in the equipment cabinet. Metered CDU The Sentry Metered CDU products provide branch circuit protection and reliable power distribution for all devices in the equipment cabinet. Local input current monitoring allows the installation engineer to verify the aggregate load on the circuit or phase. Smart CDU The Smart CDU products provide reliable power distribution coupled with remote power and environmental monitoring. Use the network interface to view power, temperature and humidity levels via Web browser, or SNMP-based and email alerts when conditions exceed defined thresholds. Add an Expansion Module CDU to Smart and Switched CDUs. Link a master and expansion unit using a single IP address. POPS Smart CDU Adds (POPS) Per Outlet Power Sensing to the Smart CDU. POPS provides power monitoring per an individual outlet/device. Power information per individual outlet /device includes current, voltage, power (kw), apparent power, crest factor, and power factor. Using our grouping technology, power information is available per device, groups of devices (application), individual CDU or cabinet. Switched CDU The Switched CDU products provide the capability to securely monitor and control cabinet power via a network for a data center or remote branch office. The Switched CDU s combine networked configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual power server with one command. Receive SNMP-based or email alerts when power or environmental conditions exceed thresholds. Assign access rights to user groups or individuals. Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amperage and high-voltage, EN 60950-1:2001 Branch Circuit Protection, and SNMP traps and email alerts including current monitoring. POPS Switched CDU Adds Per Outlet Power Sensing (POPS) to the Switched CDU which provides power monitoring per an individual outlet/device. Power information per individual outlet /device includes current, voltage, power (kw), apparent power, crest factor, and power factor. Using our grouping technology, power information is available per device, groups of devices (application), individual CDU or cabinet. Fail-Safe Transfer Switch (FSTS) The Fail Safe Transfer Switch features two input power feeds, from separate AC circuits, to supply singlepower equipment with dual, redundant power sources. If either power in-feed becomes unavailable, the FSTS auto-switches to the remaining power feed source to reestablish power to the connected equipment. PIPS CDU + Per Inlet Power Sensing (PIPS) CDUs provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU. www.saifor.com 3

CDU Product Family Secure Remote Administration Interface and Smart Load Shedding SENTRY SMART LOAD SHEDDING Load Management based on Temperature, In-feed Load, and UPS Status Server Technology is the first to offer datacenter managers the ability to automatically manage Switched CDU power outlets based on key operating parameters, including temperature, in-feed load, and UPS power status. Each outlet may be controlled by one or more of these parameters. Should the temperature or load current exceed defined thresholds or the UPS lose power and go onto battery, all or a portion of the loads may be automatically shed to ensure longer operational life of your critical devices. FEATURES > Easy to use, integral, web based GUI configuration tool > Auto-recovery with a reboot delay time when conditions return to normal Temperature & Humidity Probes Switched CDU TCP/IP Network > UPS Polling > Remote Shutdown Agent Network Switch Router > Each CDU outlet is assigned the IP address of the connected device for shut down notification UPS Windows Server Netware Server > Remote shutdown agent for server shut down HP-UX Server > SNMP trap notifications Linux Server > Load shedding event notifications via SNMP traps or Email alerts AIX Server Solaris Server SENTRY ACCESS, SECURITY & COMMUNICATION Secure Remote Administration Interface FEATURES > Secure, web based GUI configuration tool > Temperature Support (Celsius/Fahrenheit) and Humidity (%) > Logs authentications, configuration changes and system events > SNMP and email notifications for multiple users of log, event, power, and authorization, configuration messages Web Based GUI: Individual Outlet Control Screen > SYSLOG logging protocol support > Automatic Firmware Updates via FTP > Strong Password Support and Pre-Login Banner POWER INFORMATION > Input Feed Voltage (VAC) > Input Feed Watts (W) > System Total Watts (W) Web Based GUI: System Configuration Screen > System Footprint (SqFt / SqM) > System Watts/Area (W/SqFt / W/SqM) COMMUNICATION TOOLS Web Based GUI: Environmental Monitoring Screen > Web interface, SSL, SSH, Telnet, SNMP & RS-232 access, 10/100 Base T-Ethernet, SSLv3/TLSv1, SNMPv2, TACACS+, LDAP, LDAPS, RADIUS, DHCP, SMTP/Email, and Syslog. 4

CDU Power Cords & Accessories Plug and Cord Options for Sentry CDUs Saifor provides 16A and 32A products with a variety of input cord options available. Please refer to the Power Cords and cordset options below for different configurations. Shown below are standard power cord and cordset options.1 16A PLUGS & CORDS ACCESSORY OPTIONS OUTLETS VOLTAGE (V) AMPS (A) LENGTH PTCORD-2 IEC60320 / C19 to Schuko 16A 3m DESCRIPTION FUNCTION LENGTH EMTH-1-1 Temperature & Humidity Probes Measures cabinet temperature & humidity 3m OUTLETS VOLTAGE (V) AMPS (A) LENGTH PTCORD-3 IEC60320 / C19 to IEC60320 / BS434 / CEE173-Phase 16A 3m DESCRIPTION FUNCTION LENGTH EMCU-1-1B Environmental Monitoring Control Unit Supports 2 additional EMTH-1-1, water & 4 dry contact closure door sensors - OUTLETS VOLTAGE (V) AMPS (A) LENGTH PTCORD-4 IEC60320 / C19 to BS 1363 16A 3m DESCRIPTION FUNCTION LENGTH C20 Inlet Bracket C20 Inlet Retention Bracket Securely fastens C20 cord to chassis - Saifor offers a wide range of products for global markets. For more information on global products visit our website at www.saifor.com www.saifor.com 5

Sentry Power Manager Power Management Architecture SENTRY POWER MANAGER Manage Multiple CDUs Across Multiple Locations Do you have multiple Sentry CDUs in one or more locations that you would like to access from one central point? Would you like one central location where all alarms can be viewed and logged for reporting, e-mail or SNMP trap notications? No problem! Our Sentry Power Manager (SPM) product is capable of monitoring and managing multiple Sentry devices in IP-based enterprise networks. SPM provides a global view of all Sentry CDUs with the ability to view devices based on their temperature, humidity, current and device status. Besides managing and monitoring all alarm conditions, this information can also be used to provide reporting and trending information for display within SPM or integrated with your existing Building Management System (BMS). Web Based GUI: Quickly drill down from a global view to the rack level. Users can setup custom network operation center (NOC) views for whatever they want to display from global dashboard views down to each CDU, cabinet or location. Event Notification > Email notification via the CDU to multiple recipients when an event occurs > SNMP traps via the CDU when an event occurs > Auto-discovers each CDU for easy configuration > Easily create a user interface that mirrors the physical deployment of the data center > Quickly drill down from a global perspective to the rack s actual physical location if there is a problem (quickly identify the alarm and the physical location of the CDU) > Create outlet clusters to group outlets within a CDU, across linked CDUs or across enterprise locations Multiple Reporting Options > Reporting capabilities to produce reports on critical management parameters such as temperature, humidity and current load > Reports on Current and Power providing the power consumption of each input, total for the rack and/or per square foot of the rack On-Demand Accessibility > Real-time view of all active system alarms > Anytime, anywhere web-based views > Manage thousands of CDUs from a single console Compatibility > Server Technology Sentry CDUs with firmware 5.3+ Web Browsers Supported > Microsoft Internet Explorer 7.0+ > Mozilla Firefox 2.0+ A-Feed (CS/CW) B-Feed (CL/CX) LINKABLE EXPANSION MODULE The Expansion Module CDU, Smart CL or Switched CX, is our exclusive method for linking together outlets on different power circuits. The Expansion Module CDU, CL or CX, increases the number of managed outlets on a single IP address. Each expansion module links to its parent Smart CS or Switched CW, which contains both network and serial interfaces. When linked to a Smart or Switched CDU, the CL s or CX s outlets are auto-discovered by the Smart or Switched CDUs firmware, and all available outlets are viewable through the firmware. On the Switched CW, outlets are individually controllable, or groups of outlets can be controlled between the Switched CW & CX with one command. Each Expansion Module CDU can be a single or dual-power feed and a Zero-U or horizontal enclosure. 6

Sentry Power Manager Power Management Architecture POWER INFORMATION & MANAGEMENT Sentry Power Manager The Sentry Smart and Switched CDUs are capable of being monitored through the SPM (Sentry Power Manager) tool. Sentry intelligent CDUs, in conjunction with SPM, provide additional power information for consumption purposes and power monitoring as well as trending and power reports. An API allows power and other information to be communicated to a Building Management System (BMS) or other systems. Sentry Power Manager (SPM) Solutions > SPM provides a global view of all Sentry CDUs with the ability to view devices based on their temperature, humidity, current and device status. Quickly drill down from global view to your facility maps to an individual CDU. reboot, power measurement information across a single CDU, a linked CDU, or across the entire network. > Manage and monitor all user-defined alarm conditions on your entire network. > Auto-discover all your CDUs connected to your IP network. > Allows measurement of power consumption and capacity planning. > View Logs for user access, discovery, user actions, and alarms. > Multiple user levels and permissions including support for LDAP. > Control individual outlets on Switched CDUs. > Group and cluster outlets for remote " Building (BMS) or othe " Web Based SPM Interface Management System CAPACITY PLANNING POWER MANAGEMENT IT ASSET PERFORMANCE Sentry Power Manager Enterprise Cabinet Power Management CDU Auto-Discovery Reports & Trends Device Monitoring Groups & Clusters Kilowatt Readings Alarms " Sentry Power ManagerAppliane " Web Based CDU Interface Smart or Switched CDU Rack Level Power Monitoring Environmental Monitoring Outlet Groups Alarms Outlet Management (Switched CDU) www.saifor.com 7

Smart & Switched CDU with Per Inlet Power Sensing CDUs PIPS SMART & SWITCHED CDU Introducing the best infeed power measurement technology on the market for data center rack-level power monitoring. PIPS technology replaces power monitoring at the RPP (Remote Power Panel) in data centers with higher accuracy and lower cost monitoring of each power circuit attached to a CDU. This new product feature also replaces the already accurate Digital True RMS feature currently available on intelligent Smart, Switched and POPS CDUs by bringing more types of power measurements from the power infeed to the built in graphic user interface (GUI). Expect the same quality and functionality on current intelligent CDUs, but with an increased level of information to help you make the critical decisions regarding your facility. PIPS Features Sentry PIPS works in conjunction with all of the features of a Smart, Switched or POPS CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy. The PIPS CDU is capable of being accessed through either a secure network or serial connection. The secure integral web interface provides a simple and easy way to monitor the CDU. Configuration choices include: SNMP traps, email alerts, grouping, and all security and communication settings. Research shows that measuring at the infeed level is the most accurate place to measure power and is recommended by the Green Grid. Communication Tools > Web Interface > RS-232 access > 10/100 Base-T Ethernet > SMTP/Email > Telnet > SSH > SSLv3/TLSv1 > SNMPv2 > TACACS+ > LDAP > LDAPS > RADIUS > DHCP > Syslog POWER INFORMATION & MANAGEMENT Internal Web Interface System Configuration Intelligent CDUs enable network access to remotely configure access, outlets, alarms, thresholds, and more. Easy to Read Summary Screen The new summary screen allows users to quickly confirm the status of the rack power & environmental conditions. Sentry PIPS (Per Inlet/Infeed Power Information) > Current (Amps) > Power (Watts) > Power Factor > Neutral Current: Measures neutral current > Voltage (Volts) > Apparent Power (VA) > Accumulated Energy (kwh) Environmental Monitoring No additional IP address needed to obtain temperature and humidity readings. A pair of probes (EMTH-1-1) can be added to any intelligent master CDU (Smart or Switched). Additional probes can be added using an EMCU-1-1B (page 5). 8

Switched CDU Per Outlet Power Sensing CDUs POPS SWITCHED CDU Integral Web Interface Blade servers and high density computing power requirements continue to increase and POPS is the right CDU for that environment. With device-level output control, you can monitor, track and manage servers, IT equipment and the equipment cabinet infrastructure. With the ability to measure, monitor, and report power down to the rack or outlet level, this solution follows the Green Grid s recommendations for acquiring the most accurate power monitoring data. POPS Features Communication Tools > Simple, secure, integral web interface GUI configuration tool > Temperature and Humidity Support > Authentication logging, configuration changes and system events > Secure Syslog protocol support > Email notifications of log, event, authorization, power and configuration messages > Automatic Firmware Updates via FTP server > Strong Password Support and Pre-Login Banner > Ability to Ping an IP address to see if the device is responding > Grouping of outlets across Master & Expansion CDUs > SNMP: Traps based on Status, Changes, Load, Temperature and Humidity > Supports 104 user accounts and 18 simultaneous logins with a dedicated SNMP connection > Web Interface > SNMP & RS-232 access > 10/100 Base T-Ethernet > SMTP/Email > Telnet > SSL > SSH > SSLv3/TLSv1 > SNMPv2 > TACACS+ > LDAP > LDAPS > RADIUS > DHCP > Syslog POWER INFORMATION & MANAGEMENT Internal Web Interface Outlet Control Power Monitoring > Individual Outlet Control > Current Load Monitoring > Power Monitoring > Additional Details Per CDU Power Information > Current Load > System Total Watts (W) > Infeed Voltage (VAC) > System Footprint (SqFt / SqM) > Input Feed Watts (W) > System Watts (W/SqFt / W/SqM) Grouped Power Information > Cabinet (single IP address using master/expansion configuration for two CDUs) > Device (Multiple ) > Group of Devices (Application) > Individual CDU Sentry POPS (Per Outlet Power Sensing) > Current Load (A) > Apparent Power (VA) > Voltage (V) > Crest Factor > Power (W) > Power Factor www.saifor.com 9

Fail-Safe Transfer Switch (FSTS) Horizontal Rack Mounted Enclosures 1 No Input Current Monitoring 2 Internal Branch Circuit Protection CS-2HF 2 (2) C19 32A 7.3kW CS-2HF 2 1U 178mm depth 1 No Input Current Monitoring 2 Internal Branch Circuit Protection PTTS-H008 12 (8) C13 16A 3.6kW PTTS-H008 12 1U 178mm Depth 1 No Input Current Monitoring 2 Internal Branch Circuit Protection CW-16HFE 2 (16) C13 CW-16HFE 2 2U 178mm Depth 10

Basic CDU Zero-U Vertical Enclosures CB-12H2 CB-24V2 CB-24VE (12) C13 (24) C13 (24) C13 16A 16A 3.6kW 3.6kW 10U 432mm 18U 800mm 20U 862mm CB-12H2 CB-24V2 CB-24VE www.saifor.com 11

Metered CDU Zero-U Vertical Enclosures C-12VE (12) C13 3.6kW or 7.3kw 18U 794mm C-24VE (24) C13 3.6kW or 7.3kw 31U 1372mm C-24VDE (24) C13 7.3kW or 14.7kW 18U 794mm C-48V4 (48) C13 11kW or 22kW 43U 1880mm C-12VE C-24VE C-24VDE C-48V4 12

Metered CDU Horizontal Rack Mounted Enclosures C-4HE (4) C19 1U 178mm Depth C-4HE C-12HE (12) C13 1U 127mm Depth C-12HE C-24HE (24) C13 32A 7.3kW 1U 127mm Depth C-24HE C-4HDE (Dual Input) (4) C19 2U 180mm Depth C-4HDE (Dual Input) C-12HDE (12) C19 7.3kW or 14.7kW 2U 254mm Depth C-12HDE www.saifor.com 13

Smart CDU Zero-U Vertical Enclosures CS-16VE-MX CS-16VE CS-18V4 CS-24VE (16) C13 (16) C13 (18) C19 (24) C13 16A 3.6kW 11kW or 22kW 23U 1003mm 29U 1257mm CS-24VE (Busway) CS-24V4 CS-24VE-MA (18) C13 + (6) C19 (24) C13 (18) C13 + (6) C19 11kW or 22kW 37U 1620mm CS-16VE-MX CS-16VE CS-18V4 CS-24VE CS-24VE (Busway) CS-24V4 CS-24VE-MA 14

Smart CDU Zero-U Vertical Enclosures CS-24V4-A CS-24V4-A9 CS-24V4-A3 (18) C13 + (6) C19 (12) C13 + (12) C19 (24) C19 3-Phase 230/400 V 3-Phase 230/400 V 63A 11kW or 22kW 11kW or 22kW 43.4kW 43U 1905mm CS-36V4 CS-36V4-A4C CS-48VDE (36) C13 (24) C13 + (12) C19 (48) C13 3-Phase 230/400 V 32A 22kW 11kW or 22kW 7.3kW or 14.7kW 39U 1727mm 42U 1867mm 31U 1372mm CS-24V4-A CS-24V4-A9 CS-24V4-A3 CS-36V4 CS-36V4-A4C CS-48VDE www.saifor.com 15

Smart CDU Smart Modular 3-Phase CDU SAMPLE INSTALLATION Sample Installation Smart Modular 3-Phase Master (CS-3VD / VY) CDU with (3) Basic Satellite CDUs (CB-8V2-A) connected CS-3V4 CL-3V4 CS-3V4 CS-3V4 Master Expansion 32A 32A 22kW 22kW 8U 347mm 8U 347mm CB-4V2 CB-8V2-A CB-8V2-B CB-10V2 (4) C19 (6) C13 + (2) C19 (4) C13 + (4) C19 (10) C13 32A 32A 32A 32A 7.3kW 7.3kW 7.3kW 7.3kW 8U 347mm 8U 347mm 8U 347mm 8U 347mm CB-4V2 CB-8V2-A CB-8V2-B CB-10V2 16

Smart CDU Smart Power Monitor & Horizontal Rack Mounted Enclosures CS-12HDE (12) C19 7.3kW or 14.7kW 2U 254mm Depth CS-12HDE CS-2HDE (2) C19 16A 3.6kW 43U 1880mm CS-2HDE CS-2HDE Smart Power Monitor (2) 60309 32A 14.7kW 1U (254mm) Depth CS-2HDE Smart Power Monitor CS-2HD4 Smart Power Monitor (2) 60309 22kW or 44kW 1U (254mm) Depth CS-2HD4 Smart Power Monitor www.saifor.com 17

Switched CDU Zero-U Vertical Enclosures CW-16VE-MX CW-16VE CW-24VE CW-24VE-A1 (16) C13 (16) C13 (24) C13 (18) C13 + (6) C19 16A 3.6kW 23U 1003mm 29U 1257mm CW-24V4 CW-24V4-A1 CW-32VDE (24) C13 (18) C13 + (6) C19 (32) C13 11kW or 22kW 11kW or 22kW 7.3kW or 14.7kW 29U 1270mm CW-16VE-MX CW-16VE CW-24VE CW-24VE-A1 CW-24V4 CW-24V4-A1 CW-32VDE 18

Switched CDU Horizontal Rack Mounted Enclosures CW-2H2 (2) C13 16A 3.6kW 1U 140mm Depth CW-2H2 CW-8HE (8) C13 1U 178mm Depth CW-8HE CW-16HE (16) C13 2U 178mm Depth CW-16HE CW-16HDE (16) C13 2U 178mm Depth CW-16HDE www.saifor.com 19

POPS Smart CDU Zero-U Vertical Enclosures CSG-24VE (18) C13 + (6) C19 35U 1550mm CSG-24V4 (12) C13 + (12) C19 11kW or 22kW 41U 1794mm CWG-16VE-A1 (12) C13 + (4) C19 29U 1256mm CWG-24VE-A1 (18) C13 + (6) C19 CSG-24VE CSG-24V4 CWG-16VE-A1 CWG-24VE-A1 20

POPS Switched CDU Zero-U Vertical Enclosures CWG-VE-C1 (18) C13 + (6) C19 37U 1625mm CWG-24V4-A1 (18) C13 + (6) C19 11kW or 22kW CWG-24V4x458-A1 (18) C13 + (6) C19 11kW or 22kW CWG-24V4-A9 (12) C13 + (12) C19 11kW or 22kW CWG-VE-C1 CWG-24V4-A1 CWG-24V4x458-A1 CWG-24V4-A9 www.saifor.com 21

POPS Switched CDU Horizontal Rack Mounted Enclosures CWG-8HE (8) C13 1U 178mm Depth CWG-8HE CWG-16HE (8) C13 2U 178mm Depth CWG-16HE 22

www.saifor.com SAIFOR S.L. Global Headquarters International Sales Poligono Industrial La Plana, nave 4 08785 VALLBONA D'ANOIA (Barcelona) SPAIN Tel. +34 93 771 83 38 Fax +34 93 771 84 47 Email: saifor@saifor.com www.saifor.com SAIFOR France S.A.R.L. Sales Office FRANCE Zone Industrielle des Glaises 9, Rue Salvador Allende 91120 PALAISEAU France Tel. +33 01 69191290 Fax +33 01 69191291 Email : saifor@saifor.fr www.saifor.fr SAIFOR Benelux bvba Sales Office BELGIUM, NETHERLANDS & LUXEMBOURG Prins Boudewijnlaan 17, unit 4 2550 Kontich Belgium Tel. +32 3 444 05 00 Fax +32 3 444 05 09 Email: info@saifor.be www.saifor.be SAITEK, S.L. Sales Office SPAIN, PORTUGAL & ANDORRA Generalitat Valenciana 45 Urbanizacion las Lomas de Fresnos (Valdecañas) 28660 Boadilla del monte Madrid - SPAIN Tel. +34 916 402 090 Fax +34 916 402 067 saitekmadrid@saitek.es www.saitek.es

www.saifor.com Spain France Benelux Middle East