Pressure Sensors. for liquid and gaseous media

Similar documents
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Relative pressure transmitter type 520

Digital input modules

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Relative and absolute pressure switch type 529

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Product Catalogue. AP Automatyka ISO ISO OHSAS ISO 9001.

Proportional pressure regulators VPPE

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

RRV934. Multi-controller. Synco living

PRODUCT PROFILE FEATURES

Air damper actuators

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

How To Use A Flowmeter

Pressure transmitter For general industrial applications Model A-10

Conductive Level Switch FK 2 Technical Data:

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Digital inductive conductivity transmitter

TX OPEN RS232/485 module

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Flush-mount room temperature sensor AQR2531ANW.

Features. Picture. Specifications

Flush-mounted room thermostats

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Thermostatic Actuators

Typical Aluminum GFM Mass Flow Meter

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 300

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Compact pressure switch Flameproof enclosure Ex d Model PCA

VSO MAX HP High Flow Proportional Valve

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Butterfly Valves PN 6/10/16 for flanged connection

Data Sheet PS1B Pressure Switch

T0118 T2118 T3118. Instruction Manual

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Technical Information RIA14

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

DS 600. A contact free flux gate based current measurement sensor 600A rms

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Duct Humidity Transmitter

Inductive sensor NI10-M18-Y1X-H1141

Self-operated Temperature Regulators Temperature Regulator Type 1u

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Operating Instructions for Plastic Flow Meter. Model: KSK

Input module, input/output module

J TB/TW Temperature limiter, temperature monitor

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Technical Data. Dimensions

Room Temperature Sensors

How To Read A Pipe From A Sensor

Assisted lift operated 2/2-way solenoid valves Type EV250B

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

2- and 3-port valves with flanged connections, PN 10

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Cross-beam scanning system to detect slim objects. 100 mm in

Product and functional description

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Digital display DA 48

Instruction Manual Differential Pressure Transmitter

VAV compact controller KNX / PL-Link

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

3/2-way Solenoid Valve, direct-acting, NC or NO

Electronic Control Devices The European Product Catalogue 2007

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

HCR3.2/.. Chipcard reader HOTEL SOLUTION

TEIP11 I/P signal converter for standard signals. Measurement made easy

Power Supplies 3. SDN-P DIN Rail Series

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

OZS Web server. For LPB/BSB plants

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Electronic Pressure Monitoring New Products

How To Make An Ultrasonic Sensor

Electric Rotary Actuator - On/Off or programmable control actuator

ThermoSorb Desiccant Dryers

is then retained absolutely without interruption.

Thermal Flow Sensor Die

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Transcription:

1 909 1909P01 Pressure Sensors for liquid and gaseous media QBE2002-P QBE2102-P Piezo-resistive measuring system DC 0...10 V or DC 4 20 ma output signal Measurement unaffected by changes in temperature High temperature stability No mechanical aging or creepage External thread G½" Excellent EMC characteristics Use The pressure sensors are suitable for the measurement of static and dynamic positive pressure in HVAC plant, particularly in hydraulic and pneumatic systems using liquid or gaseous media (steam applications). Technical design The pressure sensors operate on the piezo-resistive measuring principle. The ceramics diaphragm (thick-film hybrid technology) acquires the pressure through direct contact with the medium. The measurement is converted electronically into a linear output signal of DC 0...10 V or DC 4 20 ma. CE1N1909en 2014-07-30 Building Technologies

Type summary Type reference Pressure range Output signal QBE2002-P1 0...1 bar 0...100 kpa 0...14.5 psi 0 10 V QBE2002-P2 0...2 bar 0...200 kpa 0...29.0 psi 0 10 V QBE2002-P4 0...4 bar 0...400 kpa 0...58.0 psi 0 10 V QBE2002-P5 0...5 bar 0...500 kpa 0...72.5 psi 0 10 V QBE2002-P10 0...10 bar 0...1.0 MPa 0...145.0 psi 0 10 V QBE2002-P16 0...16 bar 0...1.6 MPa 0...232.0 psi 0 10 V QBE2002-P20 0...20 bar 0...2.0 MPa 0...290.0 psi 0 10 V QBE2002-P25 0...25 bar 0...2.5 MPa 0...362.6 psi 0 10 V QBE2002-P40 0...40 bar 0...4.0 MPa 0...580.0 psi 0 10 V QBE2002-P60 0...60 bar 0...6.0 MPa 0...870.0 psi 0 10 V QBE2102-P4 0...4 bar 0...400 kpa 0...58.0 psi 4 20 ma QBE2102-P5 0...5 bar 0...500 kpa 0...72.5 psi 4 20 ma QBE2102-P10 0...10 bar 0...1.0 MPa 0...145.0 psi 4 20 ma QBE2102-P16 0...16 bar 0...1.6 MPa 0...232.0 psi 4 20 ma QBE2102-P20 0...20 bar 0...2.0 MPa 0...290.0 psi 4 20 ma Ordering When ordering, please give name and type reference, e.g.: Pressure sensor QBE2002-P1 Any accessories required must be ordered separately. Equipment combinations The pressure sensors can be combined with all devices or systems capable of processing the DC 0...10 V or DC 4 20 ma output signal from the pressure sensor. Mechanical design The pressure sensors are compact units and cannot be dismantled. No changes or adjustments are possible. Accessories AQB22.1 Fixing bracket for sensor (for remote mounting). For dimensions, refer to "Dimensions" AQB2001 Mounting kit for remote mounting with 1 m copper capillary line, both ends prefabricated ready for connection. Thread adapters and terminal nuts made of brass. Pressure connection with G1/8 or G1/2 outer threading. 2/6

Mounting notes Mounting Instructions are enclosed with the sensor. The sensors are designed for direct connection to screwed fittings with G½" threads. Appropriate measures must be taken to ensure a leak-proof fitting. To provide for test measurements without leakage of the medium, it is strongly recommended that an appropriate test adapter and shutoff device be fitted. Pressure measurement with liquids The tapping point should be at the side, near the bottom of the pipe. Do not measure the pressure from the top of the pipe (where it may be affected by airlocks) or the bottom (where it may be affected by dirt). Always evacuate the system. 1909Z03 Pressure measurement with condensing gases The tapping point should be at the top so that no condensate reaches the sensor. 1909Z04 Remote mounting If the temperature of medium is lower than 40 C or higher than 80 C, the sensor should be fitted remotely, taking care that no condensate can reach the sensor. For remote mounting, a fixing bracket AQB22.1 and mounting kit AQB2001 can be delivered (refer to "Accessories"). For remote mounting, the sensor can be operated together with the AQB pressure mounting kit in ambient temperatures of up to 70 C for medium temperatures of up to Condensate or liquid 180 C. Care must be taken in this case to ensure that the cooling efficiency of the copper pipe is not reduced by additional heat sources or by restrictions to the air circulation. The admissible pressure is limited to 93 bar for temperatures >120 C. 3/6

Disposal The devices are considered electronics devices for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic waste. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Technical data Electrical interface Power supply Supply voltage (QBE2002 )Current consumption Supply voltage (QBE2102 ) Current consumption External supply line protection Output signal QBE2002 Output signal QBE2102 with extra-low voltage only (SELV) AC 24 V ±15%, 50...60 Hz or DC 18...33 V< 6 ma DC 11 33 V <20 ma Fuse slow max. 10 A or Circuit breaker max. 13 A Characteristic B, C, D according to EN 60898 or Power source with current limitation of max. 10 A DC 0...10 V, RLoad >10 k (not galvanically separated, 3-wire connection, short-circuit proof and protected against polarity reversal) Operating voltage 11 V DC 4 20 ma, RLoad Ohm 0.02 A (not galvanically separated, 2-wire connection, short-circuit proof and protected against polarity reversal) Functional data Application range refer to "Type summary" Accuracy: Total of linearity, hysteresis and reproducibility Zero point, Full scale Temperature drift: TC zero point TC sensitivity (FS = Full Scale) <± 0.4 % FS <± 0.6 % FS balancing in bar <± 0.04 % FS/K <± 0.015 % FS/K Response time Nominal pressure Max. admissible pressure Rupture pressure Media Admissible temperature of medium Maintenance Mounting position <5 ms relative pressure as in "Type summary" (measurement of difference from ambient pressure) 2 x scale end value of measuring range (FS) 3 x scale end value of measuring range (FS) neutral and slightly corrosive liquids and gases (suited for use with oil-contacting media) 40... 80 C maintenance-free Optional 4/6

Degree of protection Protection degree of housing IP65 according to EN 60529 Protection class III according to EN 60730 Connections Connecting cable PVC, length 1.5 m, 3 x 0.25 mm 2 stranded wires Environmental conditions Screwed fitting Operation to Climatic conditions Temperature Humidity Storage/ transport Climatic conditions Temperature Humidity Directives and Standards Product standard EN 61326-1 Environmental compatibility external thread G½", inside thread M5 IEC 60 721-3-3 class 3K7 40... 80 C insensitive to condensation IEC 60 721-3-2 class 2K4 40... 8 0 C insensitive to condensation Electrical equipment for measurement, control and laboratory use. EMC requirements. General requirements EU Conformity (CE) CE1T1909xx *) RCM Conformity 8000078879 The product environmental declaration CE1E1909 *) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Materials Base stainless steel (1.4305) Measuring element ceramics diaphragm Cover stainless steel (1.4305) Sealant Fixing bracket AQB22.1 Mounting kit AQB2001 Weight Including packaging 0.265 kg FPM fluor-caoutchouc spec. die-cast aluminium see "Accessories" *) The documents can be downloaded from http://siemens.com/bt/download. 5/6

Internal diagram QBE2002 (+) ( ) (0) G U M 1909G01 BT terminal marking Color of core Meaning G (+) Brown Supply voltage AC 24 V or DC 18...33 V U ( ) Green Output signal DC 0...10 V (signal ground GND) M (0) White GND QBE2102 (+) ( ) G 1907G 02 BT terminal marking Color of core Meaning G (+) Brown Supply voltage DC 11...33 V I ( ) Green Output signal DC 4...20 ma Dimensions QBE2002-P QBE2102-P 20 10 G1/2 1909M01 ø 34,5 SW 27 ca. 87 ca. 108 AQB22.1 37,5 M4 37 57 20 5 21 4,5 20 SW 27 10 ø 4,5 1909M02 Dimensions in mm 6/6 2005-2014 Siemens Switzerland Ltd. Subject to change