Pressure and Differential Pressure Transducer

Similar documents
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Combi switchbox with integrated 3/2 way pilot valve

How To Use A Flowmeter

Digital inductive conductivity transmitter

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

PRODUCT PROFILE FEATURES

Datalogger DL/N 70 Version:

Electronic Pressure Switch EDS 3000

Features. Picture. Specifications

Digital display DA 48

Conductive Level Switch FK 2 Technical Data:

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Relative and absolute pressure switch type 529

Pressure transmitter For general industrial applications Model A-10

Rosemount 333 HART Tri-Loop

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

GREISINGER electronic GmbH

Plastic tube flowmeters Series PT/PS

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Product Catalogue. AP Automatyka ISO ISO OHSAS ISO 9001.

Rosemount 333 HART Tri-Loop

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Electric Rotary Actuator - On/Off or programmable control actuator

How To Make An Ultrasonic Sensor

Duct Humidity Transmitter

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Operating Instructions for Plastic Flow Meter. Model: KSK

4 Posiflow Proportional Solenoid Valves

ATL Fuel Level Sender Probes

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Safety at a high level!

Analog signal converters CC-E I/I Current / current isolators

SITRANS F flowmeters SITRANS F M

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Models SFP33 & SFP32 Pressure Transmitters

J TB/TW Temperature limiter, temperature monitor

Data Sheet PS1B Pressure Switch

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Control Devices Catalogue. Control Devices. Preferred and Standard Products

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Mass Flow Meters & Controllers

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Typical Aluminum GFM Mass Flow Meter

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Electronic Pressure Switch EDS 300

FIREDEX Conventional Fire Panels

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Inductive sensor NI10-M18-Y1X-H1141

Hand-held thermometer Model CTH7000

Series 7500 Torque Sensor

PIEZOMETER AIRFLOW MEASURING RING

Self-operated Temperature Regulators Temperature Regulator Type 1u

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Series 6000 Torque measured metal bellow coupling

Instruction Manual Differential Pressure Transmitter

Gas Turbine Fuel Control Valve

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Relative pressure transmitter type 520

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

FREJA 300 Relay Testing System

Stainless steel process fittings

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Incubator with mechanical convection

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Heating oven with mechanical convection

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RM4TG20 three-phase network control relay RM4-T - range V

API Marine. BMS Presentation. Ballast Measurement Systems

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Current and voltage measuring relays

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Contact expansion modules

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

crm+25/d/tc/e Extract from our online catalogue: Current to:

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

TX OPEN RS232/485 module

Material test chamber with mechanical convection

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Transcription:

Pressure and Differential Pressure Transducer Construction The EMÜ 30 pressure and differential pressure transducer has an all plastic housing and is suitable for relative pressure / differential pressure measurements from 0- bar to 0-0 bar. The pick-up is temperature compensated and is available in various designs. The process connection is configured as standard with male threads to DIN 385 or DIN 688. The electrical connection is via a plug complying with DIN EN 7530-803 Form A. The transducer is calibrated at the factory and provides industrial standard measuring signals. Features The pressure transducer converts the physical variable pressure proportionally into an electrical signal. The differential pressure transducer measures the physical variable pressure at measuring points and converts the differential into an electrical signal. Plus and minus differentials are evaluated. EMÜ 30 is available as a wire transducer (4-0 ma) and as a pressure measurement device with either current (0/4-0 ma) or relay output (adjustable MIN and MAX switch points). Advantages All plastic design Ceramic sensor with PTFE foil Linear output signal Simple mounting Fast response time Optional mounting position Minimum temperature influence Transducer dimensions code 600 [mm] /4 9 88 7 / 7 9 67 63 50 30

Technical data Input parameters Measuring span 0-0 bar (see order key) limit see table (page 3) Materials Materials of medium wetted parts Connecting element PVDF Sensor - Stainl. steel (code A0) Stainl. steel.440/.430 - PTFE (code A3) PTFE foil 0.5 mm on ceramic sensor Seal Output parameters wire transducer Output span 4-0 ma Load impedance see characteristic Measurement device with current output Output span 0/4-0 ma Load impedance 750 Ω Voltage output 0-0 V upon request Measurement device with relay output Switching output 5 V AC / 0.6 A 0 V DC / 0.6 A 30 V DC /.0 A Switch points Min relay adjustable from 0-00% Max relay adjustable from 0-00% ysteresis ±% of measuring span Optical display Type LC display 3 / digit Units bar, psi Functions (selection by switch) Display of measured value Switch point MIN relay Switch point MAX relay Accuracy ±0.5% of measuring span ± digit Temperature coefficient of zero output typ 0.%/0K of measuring span Temperature coefficient of output span typ 0.%/0K of measuring span influence 0.% of measuring span Characteristic deviation at limiting value adjustment - Sensor material (code A0) (incl. repeatability) ±0.5% of measuring span ysteresis ±0.% of measuring span - Sensor material (code A3) ± % of measuring span (incl. hysteresis and repeatability) Warming up time 5 min Response time 0 ms Auxiliary power wire transducer 5-35V DC Measurement device Maximum ripple Ambient conditions Ambient temperature Medium temperature 4V DC (+0%, -5%) / 50mA V -0 C... +50 C -0 C... +60 C wire transducer: Storage temperature -0 C... +60 C Directives: EMC directive 89/336/EEC Low voltage directive 73/3/EEC Protection class IP 65 Materials of parts in contact with the ambience Connecting element PVDF ousing PP ousing cover of measurement device PSU Mechanical data Pressure connection Connecting element /4A to DIN 688 /A to DIN 688 /4A to DIN 385 /A to DIN 385 3/4A to DIN 385 Torque max. 0 Nm Electrical connection Plug according to DIN EN 7530-803 Form A Mounting position optional Weight wire transducer appr. 70 g Measurement device appr. 300 g Differential pressure measurement device appr. 500 g Pressure / temperature correlation for PN 0 Temperature [ C] -0-0 ±0 5 0 0 5 30 40 50 60 70 80 Material permissible operating pressure [bar] PVDF 0-0,0 0,0 0,0 0,0 0,0 0,0 9,0 8,0 7, 6,3 - - 30

Technical data Sensor material Measure range min. Table : Measuring ranges / Sensor material Stainless steel (code A0) PTFE (code A3) max. [bar] Bursting pressure Max. medium temperature min. max. [bar] Bursting pressure Max. medium temperature [bar] rel.* abs. rel.*/abs. rel.*/abs. [ C] rel.* abs. rel.*/abs. rel.*/abs. [ C] 0 -,0-0,6 n.v. 4,0 7 60 - - - - - 0 -,6-0,6 n.v. 6,4 60 - - - - - 0 -,5-0,6 n.v. 0,0 6 60-0,7 n.v. 6 60 0-4,0-0,6 n.v. 6,0 6 60-0,7 n.v. 6 60 0-6,0-0,6 n.v. 6,0 5 60-0,7 n.v. 6 5 60 0-0,0-0,6 n.v. 6,0 5 5-0,7 n.v. 6 5 5 * the differential pressure measurement device operates with relative pressure sensors / n.v. = not available, can be used up to 0mbar/abs / Two different pressure sensors are used in the relative and absolute pressure versions. Load impedance wire transducer Connection diagram Measurement device with relay output 35 = Actual value = MIN value 3 = MAX value 3 4 Display changeover (in housing) Supply voltage [VDC] 30 5 0 5 Supply voltage = ND = 4 V DC 3 0 500 000 Load impedance [Ohm] Signal output = MIN MIN-Relais relay = Uv 3= MAX MAX-Relais relay Connection diagram wire transmitter Connection diagram Measurement device with current output Supply voltage = ND = 4 V DC 3 4 V Signal output = ND = 0/4-0 ma 3 30

Order data Connection size Differential pressure measurement device /4 (differential pressure) D / (differential pressure) D Relative pressure measurement device /4 (relative pressure) / (relative pressure) 3/4 (relative pressure) 3 Absolute pressure measurement device /4 (absolute pressure) A / (absolute pressure) A 3/4 (absolute pressure) A3 Connection type At rear of housing Connection standard DIN 688 (not for connection code A3/3) DIN 385 Sensor material Stainless steel.440,.430 Ceramic sensor, PTFE coated R 9A 9B Material PVDF 0 A0 A3 Accuracy class 0,5% (sensor material A0) C % (sensor material A3) D Transducer -wire transducer without display, Connection size code A-A3/D-D3 600 0-0 ma, with display 60 0-0 ma, without display 6 4-0 ma, with display 60 4-0 ma,without display 6 Measurement device with relay output, with display 630 Measuring range 0- bar (only sensor material code A0) 00 0-.6 bar (only sensor material code A0) 00 0-,5 bar 003 0-4 bar 004 0-6 bar 005 0-0 bar 006 0-4 psi (only sensor material code A0) 0 0-3 psi (only sensor material code A0) 0 0-36 psi 03 0-58 psi 04 0-87 psi 05 0-45 psi 06 0-0.5 MPa 03 0-0.4 MPa 04 0-0.6 MPa 05 0- MPa 06 Order example 30 R 9A 0 A3 D 600 006 Type 30 Connection size (code) Connection type (code) R Connection standard (code) 9A Connecting element material (code) 0 Sensor material (code) A3 Accuracy class (code) D Transducer (code) 600 Measuring range (code) 006 30 4

Transducer dimensions code 600 [mm] /4 9 88 7 / 7 9 67 Transducer dimensions code 600 [mm] Connection standard code 9B /4 9 8 7 / 7 67 3/4 3 83 69 63 63 50 50 5 Ceramics KERAMIK Stainl. steel.430 Edelstahl.430 Stainl. Edelstahl steel.440 PVDF PTFE-Folie foil PVDF Sensor construction example, sensor material code A0 Sensor construction example, sensor material code A3 Transducer dimensions [mm] 60 / 6 / 60 / 6 / 630 / 63 /4 9 0 85 / 7 05 80 Transducer dimensions [mm] 60 / 6 / 60 / 6 / 630 Connection standard code 9B /4 9 95 85 / 7 9 80 3/4 3 96 8 5 5 30

Dimensions Differential pressure measurement device 60 / 6 / 60 / 6 / 630 [mm] /4 9 5 08 / 7 9 03 Connection standard code 9B /4 9 8 08 4 For further transducers, accessories and other products please see our Product Range catalogue and Price List. Contact EMÜ. Should there be any doubts or misunderstandings, the erman Subject to alteration 0/06 88058 version of this data sheet is the authoritative document! Technical data sheet VALVES, MEASUREMENT AND CONTROL SYSTEMS EMÜ ebr. Müller Apparatebau mb & Co. K Fritz-Müller-Str. 6-8 D-74653 Ingelfingen-Criesbach Tel. +49(0) 40/3-0 Telefax +49(0) 40/3-4 info@gemue.de www.gemu-group.com