FX2 Guide to using Front Panel controls, indicators, and CMC for system identification, configuration and troubleshooting

Similar documents
Dell Wyse Datacenter for View RDS Desktops and Remote Applications

Installing idrac Certificate Using RACADM Commands

How To Create A Web Server On A Zen Nlb (Networking) With A Web Browser On A Linux Server On An Ipad Or Ipad On A Raspberry Web 2.4 (

Dell Solutions Configurator Guide for the Dell Blueprint for Big Data & Analytics

High Performance SQL Server with Storage Center 6.4 All Flash Array

Managing Web Server Certificates on idrac

Recommended Methods for Updating Firmware on Dell Servers

Using Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2

Dell Fabric Manager Installation Guide 1.0.0

Active Fabric Manager (AFM) Plug-in for VMware vcenter Virtual Distributed Switch (VDS) CLI Guide

Dell Server Management Pack Suite Version For Microsoft System Center Operations Manager And System Center Essentials User s Guide

idrac7 Version With Lifecycle Controller 2 Version 1.1 Quick Start Guide

Accessing Remote Desktop using VNC on Dell PowerEdge Servers

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

Dell Compellent 6.5 SED Reference Architecture and Best Practices

Dell OpenManage Network Manager Version 5.3 Service Pack 2 Quick Start Guide

Dell Latitude E6320. Setup and Features Information. About Warnings. Front and Back View

Remote Installation of VMware ESX Server Software Using Dell Remote Access Controller

Dell Precision Workstation T3600/T5600/ T7600

Dell Vostro 3460/3560

Dell EqualLogic PS Series iscsi Storage Arrays With Microsoft Windows Server Failover Clusters Hardware Installation and Troubleshooting Guide

Deploying Dell OpenManage Server Administrator on VMware ESXi Using Dell Online Depot and VMware Update Manager

Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX

Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4

Dell Vostro 3350/3450/3550/3750

Dell FlexAddress for PowerEdge M-Series Blades

Open Networking: Dell s Point of View on SDN A Dell White Paper

RAID And Storage Configuration using RACADM Commands in idrac7

HUAWEI Tecal E6000 Blade Server

Integrated Dell Remote Access Controller 7 (idrac7) Version User's Guide

Manage Dell Hardware in a Virtual Environment Using OpenManage Integration for VMware vcenter

Dual-Core Processors on Dell-Supported Operating Systems

VMware ESX 2.5 Server Software Backup and Restore Guide on Dell PowerEdge Servers and PowerVault Storage

Proactively Managing Servers with Dell KACE and Open Manage Essentials

VMware vsphere 5 on Dell PowerEdge Systems Deployment Guide

Citrix XenDesktop VDI with Dell Storage SC4020 All-Flash Arrays for 1,800 Persistent Desktop Users

Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance

Microsoft Exchange 2010 on Dell Systems. Simple Distributed Configurations

Dell PowerVault MD32xx Deployment Guide for VMware ESX4.1 Server

Dell idrac7 with Lifecycle Controller

Migrating an Oracle Database to Dell Compellent Storage Center

or later or later or later or later

Dell Latitude 3440/3540

Dell Server Management Pack Suite Version 6.0 for Microsoft System Center Operations Manager User's Guide

Dell Latitude E6540. Setup and Features Information. Front and Back View. About Warnings

Role-Based Security and its Implementation

DELL Remote Access Configuration Tool

Dell PowerEdge M1000e Enclosure Owner's Manual

Agent-free Inventory and Monitoring for Storage and Network Devices in Dell PowerEdge 12 th Generation Servers

Discovery and Inventory of Dell Devices using OpenManage Essentials

CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers

Upgrade to Microsoft Windows Server 2012 R2 on Dell PowerEdge Servers Abstract

Active Fabric Manager (AFM) Installation Guide 2.0

Using Red Hat Network Satellite Server to Manage Dell PowerEdge Servers

DELL. Virtual Desktop Infrastructure Study END-TO-END COMPUTING. Dell Enterprise Solutions Engineering

Dell Latitude E5440/E5540

Cisco UCS vcenter Plug-in Quick Start Guide April, 2013

How To Connect To A Network On A Pc Or Mac (For Mac) On A Microsoft Mac 2.5 (For Ipo) On An Ipo 2.2 (For Pc) On Zephone (For Pnet) On

Configuring Dell OpenManage IT Assistant 8.0 to Monitor SNMP Traps Generated by VMware ESX Server

Service Description. Remote Consulting Service. Introduction to your service agreement. The scope of your service agreement

DELL. Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING

Power and Cooling Innovations in Dell PowerEdge Servers

Dell Performance Analysis Collection Kit. User's Guide

Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 User s Guide

How To Manage A Data Center Remotely From A Computer Or Network Remotely

Using MLAG in Dell Networks

Dell Red Hat Cloud Solutions Reference Architecture Guide

Using Dell EqualLogic Storage with Microsoft Windows Server 2012

Dell PowerEdge R630 Owner's Manual

System. A Product Concept Introduction ORACLE WHITE PAPER JUNE 2015

Converged Networking Solution for Dell M-Series Blades. Spencer Wheelwright

SUN FIRE X4170 SERVER

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview

Dell PowerEdge R320 Systems Owner's Manual

Fujitsu PRIMERGY Servers Portfolio

How To Backup And Restore A Database With A Powervault Backup And Powervaults Backup Software On A Poweredge Powervalt Backup On A Netvault 2.5 (Powervault) Powervast Backup On An Uniden Power

Dell Reference Configuration for Hortonworks Data Platform

Lifecycle Controller Platform Update/Firmware Update in Dell PowerEdge 12th Generation Servers

FUJITSU Enterprise Product & Solution Facts

Mini server, BIG performance AC100

Network Virtualization with Dell Infrastructure and VMware NSX

Systems Management Tools And Documentation Version 8.1 Installation Guide

Dell PowerEdge T130 Owner's Manual

6Gb SAS Host Bus Adapter Product Guide

DVS Enterprise. Reference Architecture. VMware Horizon View Reference

DD670, DD860, and DD890 Hardware Overview

Enhancements to idrac7 Alert Notification

Simplifying Systems Management for Computer Associates (CA) NSM r11.1 and r11.2 for Dell Hardware A Dell Technical White Paper

Deploying Citrix MetaFrame on IBM eserver BladeCenter with FAStT Storage Planning / Implementation

Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server

DELL. Unified Server Configurator Security Overview. A Dell Technical White Paper. By Raja Tamilarasan, Wayne Liles, Marshal Savage and Weijia Zhang

An Oracle White Paper April 2012; Revised July Improving Data Center Infrastructure with Oracle s Sun x86 Systems

Oracle Database Scalability in VMware ESX VMware ESX 3.5

NEC EXPRESS5800/R320c-E4 Configuration Guide

How To Compare Two Servers For A Test On A Poweredge R710 And Poweredge G5P (Poweredge) (Power Edge) (Dell) Poweredge Poweredge And Powerpowerpoweredge (Powerpower) G5I (

Understanding DRAC/MC Alerts

McAfee Firewall Enterprise

ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK

Active Fabric Manager Deployment Guide 1.5

Transcription:

FX2 Guide to using Front Panel controls, indicators, and CMC for system identification, configuration and troubleshooting Dell Engineering and Technical Marketing January 2015 A Dell Deployment and Configuration Guide

THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. 2014 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell. PRODUCT WARRANTIES APPLICABLE TO THE DELL PRODUCTS DESCRIBED IN THIS DOCUMENT MAY BE FOUND AT: http://www.dell.com/learn/us/en/19/terms-of-sale-commercial-and-public-sector Performance of network reference architectures discussed in this document may vary with differing deployment conditions, network loads, and the like. Third party products may be included in reference architectures for the convenience of the reader. Inclusion of such third party products does not necessarily constitute Dell s recommendation of those products. Please consult your Dell representative for additional information. Trademarks used in this text: Dell, the Dell logo, Dell Boomi, Dell Precision,OptiPlex, Latitude, PowerEdge, PowerVault, PowerConnect, OpenManage, EqualLogic, Compellent, KACE, FlexAddress, Force10 and Vostro are trademarks of Dell Inc. Other Dell trademarks may be used in this document. Cisco Nexus, Cisco MDS, Cisco NX- 0S, and other Cisco Catalyst are registered trademarks of Cisco System Inc. EMC VNX, and EMC Unisphere are registered trademarks of EMC Corporation. Intel, Pentium, Xeon, Core and Celeron are registered trademarks of Intel Corporation in the U.S. and other countries. AMD is a registered trademark and AMD Opteron, AMD Phenom and AMD Sempron are trademarks of Advanced Micro Devices, Inc. Microsoft, Windows, Windows Server, Internet Explorer, MS-DOS, Windows Vista and Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell and SUSE are registered trademarks of Novell Inc. in the United States and other countries. Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Citrix, Xen, XenServer and XenMotion are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware, Virtual SMP, vmotion, vcenter and vsphere are registered trademarks or trademarks of VMware, Inc. in the United States or other countries. IBM is a registered trademark of International Business Machines Corporation. Broadcom and NetXtreme are registered trademarks of Broadcom Corporation. Qlogic is a registered trademark of QLogic Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and/or names or their products and are the property of their respective owners. Dell disclaims proprietary interest in the marks and names of others. 2 FX2 CMC Front Panel Guide

Table of contents 1 FX2 Front Panel Overview... 4 2 Workflows... 9 2.1 Chassis Power Button... 9 2.2 KVM Selection... 9 2.3 Identify Server... 10 2.4 Chassis Health Indicators... 10 A Additional resources... 12 3 FX2 CMC Front Panel Guide

1 FX2 Front Panel Overview The Dell PowerEdge FX2 or FX2s is a new 2U rack-based hybrid computing platform that provides a greater dimension of functional flexibility, along with a higher density of processing power. The FX2 Front panel design enables optimal use of the space available on either side of the platform. The Control Panel has the following components: Three buttons with LED indicators for power, system identification, and KVM selection. Four diagnostic LED indicators for temperature, I/O Module, electrical, and health. The IO Panel has a VGA connector and a USB connector. You can map the connectors to a server, using the KVM button, RACADM, or GUI. Figure 1 Dell PowerEdge FX2 Front Panel Features and Indicators Table 1 Dell PowerEdge FX2 or FX2s Front Panel Features and Indicators 1 Allows you to switch the KVM connectivity between sleds in the KVM select button chassis. The KVM button LED glows steadily when video (6) is connected and it blinks when mapped to a server. 2 The system identification buttons on the front and back panels enable you to locate a particular server and associated PCIe cards. The system identification buttons and chassis LEDs work as follows: System identification button and Chassis LED 3 Diagnostic indicators 4 Enclosure poweron indicator, power button Press the system identification button to turn on or turn off the fornt and rear Chassis LEDs, the selected server LED and associated PCIe card LEDs. The LEDs will continue to blink until you press one of the identification buttons again or change the state from a management interface. Each time you cycle the system identification on and off the system status indicator LED moves to the next system. The diagnostic LED indicators turn on to indicate the error status (temperature, I/O, electrical, and health). The enclosure power-on indicator turns on when the enclosure turns on. The power button controls the power supply output to the system. To gracefully shutdown all servers, press and hold the power 4 FX2 CMC Front Panel Guide

button for five seconds.. To force shutdown all servers, press and hold the power button for ten seconds. 5 Sleds PowerEdge FX2 enclosure supports up to eight quarter-width sleds or four half-width sleds. 6 Video connector Enables you to connect a monitor to the system. 7 USB connector Enables you to connect a keyboard or mouse to the system. Figure 2 Dell PowerEdge FX2s Back Panel Features and Indicators (FC430 and FC630) Table 2 1 Dell PowerEdge FX2 or FX2s Back Panel Features System identification button and Chassis Controller LED The system identification buttons on the front and back panels enables you to locate a particular server and associated PCIe cards. If you press one of these system identification buttons, the system status indicator LEDs on the front and back panels blink continuously until you press one of the buttons again. Press the system identification button to turn on or turn off the system ID. Each time you press the button twice (on & off), the system status indicator LED moves to the next server. 5 FX2 CMC Front Panel Guide

Figure 3 Figure 5 Front Panel Status on GUI The Front Panel Status Page provides the following information: Enabled/disabled state of the chassis power button KVM I/O Panel Health - (if this is not healthy check the chassis overview or chassis log for a detailed explanation) KVM server mapping Chassis Health Indicators status Indicate the values 6 FX2 CMC Front Panel Guide

Figure 4 GUI Front Panel Configuration The Front Panel Configuration Page can configure: enabled/disabled state of the chassis power button enabled/disabled status of the I/O panel KVM KVM server mapping 7 FX2 CMC Front Panel Guide

Figure 5 GUI Identify The Identify page is both a status and configuration page for the component LEDs in the system. To change the blinking state of one or more components, select the check boxes corresponding to the components and press Unblink or Blink. The ID buttons at the front and rear of the FX2 will blink/unblink chassis, chassis controller, one server, and the PCIe. The component identification LEDs can be set to blinking with the ID buttons, then turned off by the GUI and vice versa. For eexample, server 3c (3 rd server in the configuration above) could be set to blinking though the GUI then turned off by pressing one of the ID buttons six times (to blink then unblink 1 st, 2 nd, and 3 rd server). 8 FX2 CMC Front Panel Guide

2 Workflows 2.1 Chassis Power Button Initially the Dell PowerEdge FX2 or FX2s Chassis is turned off. Press the chassis power button on the Control Panel to turn on the chassis. This action turns on the chassis and other subsystems (idrac on the servers, IOMs, main board, and PCIe Adapters), but the servers are not turned on. The indicator in the power button glows when the chassis is turned on. Press and hold the chassis power button on the Control Panel for five seconds to turn off the chassis and associated components (servers, IOMs, main board, PCIe Adapters, and power supplies). However, the CMC remains turned on. In this state, one of the power supply unit remains functional, and the fans are on to provide cooling to the CMC. The power is supplied to the fans that are running at low speed. Press and hold the chassis power button on the Control Panel for ten seconds to force a non-graceful turn off of the entire chassis (chassis, servers, IOMs, main board, PCIe Adapters, and power supplies). Using this method, you cannot perform a proper shutdown of the server operating system before turning them off. To disable the chassis power button actions from the GUI, go to Front Panel > Setup, select the Disable Chassis Power Button check box, and then click Apply. After power loss and recovery, the chassis returns to the state before the power loss. If the servers are turned on, power is supplied to the servers when it becomes available. 2.2 KVM Selection The FX2 chassis provides KVM functionality through a VGA connector and single USB port on the IO Panel. When you connect an external monitor to the VGA connector, the KVM button LED on the Control Panel glows. To switch through all servers (including multi-node sled like FM120x4) one after the other, press the KVM select button on the Control Panel. When a server is selected, the KVM button on the Control Panel and the System status indicator LED on the server blink continuously (two blinks per second). To disable the KVM function from the GUI, go to the Front Panel > Setup page, select the Enable KVM Mapping check box, and click Apply. The fact that the KVM button glows only when the VGA is connected is useful when it is connected to an external KVM switch. Use the KVM button LED as an indicator of which FX2 chassis is selected by the external KVM. Based on the following conditions, the KVM button LED glows or blinks: Blinks while the KVM is enabled, a monitor is connected, and a server is selected. Glows continuously when the KVM is enabled and monitor is present, but no server is selected (unmapped.) 9 FX2 CMC Front Panel Guide

Note: The KVM Button LED blink pattern (two per second) is faster than the system identification buttons blink pattern (one per second). 2.3 Identify Server The Dell PowerEdge FX2 or FX2s chassis has system identification buttons on the Front Control Panel and Back Control Panel (on the CMC). Press either of the buttons to turn identification on or off for the chassis, chassis controller, one server (which increments), and the PCIe modules associated that server. Each cycle (two presses) of identification increments which present server is identified (empty slots are skipped). The first time either ID button is pressed the first present server will identify along with the chassis, the chassis controller and all PCIe modules associated with that server. The second time either ID button is pressed identification on all these components will be turned off and the ID LEDs will stop blinking. The third time either ID button is presses the second present server will identify along with the chassis, the chassis controller and all PCIe modules associated with that server. To view the system identification LED status and enable or disable system identification from the GUI, go to Chassis Controller > Troubleshooting > Identify. This page displays the system identification LED blinking state based on the chassis and associated chassis components. To change the blinking state, select the corresponding components check boxes, and click Blink or Unblink. The component identifications LEDs can be set to blinking with the ID buttons then turned off by the GUI and vice versa. Note: When a FM120x4 server is identified, the LED on the associated hard drives also blinks. 2.4 Chassis Health Indicators The FX2 has four health indicators: Chassis Health: LED glows, solid blue: Indicates when no faults exist. Blinks amber when a a fault exists that is not associated with the other three fault indicators, thermal, electrical or IO. Thermal Fault: LED blinks amber: Indicates when a thermal fault exists, which includes fan failures and excessive ambient conditions. 10 FX2 CMC Front Panel Guide

Electrical Fault: LED blinks amber: Indicates when an electrical fault exists, which includes PSU faults and PSB VR faults. IO Fault: LED blinks amber: Indicates when an I/O module fault exists, which includes IOM faults and PCIe Card Module faults. 11 FX2 CMC Front Panel Guide

A Additional resources FX2 Chassis Owner s Manual FX2 CMC User s Guide Getting Started Guide and Rack Installation Guide available on the White Glove FTP site. Dell Server Administrator User s Guide on the OMSA Manuals page FX2 CMC RACADM Guide idrac with Lifecycle Controller Quick Start Guide idrac7 User Guide 12 FX2 CMC Front Panel Guide