FRESCO. Guide Specifications

Similar documents
Triarch Products Over Various Interior Substrates

Specifications. PermaTone, Inc. Manufacturer s Long Form Specifications Interior Finish Coatings PF-405

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Section EXTERIOR STONE VENEER Full Mortar

Tractor Painting Tips

Division 9. SignaFlor Pad and Pour Flooring System

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products

A. Work on this project shall consist of, but is not limited to, the following:

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

SECTION POLISHED CONCRETE FINISHING

[Note: This guide specification may be used for Polomyx All-Acrylic, Polomyx Waterbase and Zolatone Waterbase multicolor finishes.

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

GigaCrete Specification PlasterMax

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

SC2000 CEMENT BONDING PROCEDURES

Document Library TS Data Sheet

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Guide Specification SECTION SHEET CARPETING PART 1 - GENERAL 1.1 SUMMARY. A. This Section includes broadloom carpet. 1.

White rust on galvanized and galvanized pre-painted steel. Technical Information

Acrylic Enamel Topcoat

Product Information/Specifications

Section Polished Concrete Finishing. Vexcon

Colorado State University. Durrell Center Roof Repair

Acrylic Walls Installation Instructions

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

GUIDELINES FOR POLISHED CONCRETE FLOORS A Guide for Integrally Colored, Dyed and Stained Polished Floors

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

SECTION WATER STORAGE TANK PAINTING

Care and Maintenance for Wood Flooring

GUIDELINE SPECIFICATIONS

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

General Surface Preparation

SECTION PAINTS AND COATINGS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

Sunbrella Care and Cleaning Instructions

Newfoundland and Labrador Paint Recycling Program Guidelines

SECTION STANDING SEAM METAL ROOFING

Application of Exterior Wood Finishes

RAPTOR TRUCK BED LINER - BLACK

Armstrong Do-It-Yourself Tile Installation System

Metal Rescue Rust Remover Technical Data

Vinyl Composition Tile Installation System

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

SECTION POLISHED CONCRETE FINISHING. InovaCrete Polished Concrete Floor Finish (GUIDE SPEC)

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

UFGS (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Active and Passive Sash Replacement

Smartstrand Cleaning Guidelines

Scotch-Weld. Low-Odor Acrylic Adhesives DP810 DP810 NS. Technical Data June, 2004

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Minor Cracks in Horizontal Surfaces

AUTO COLLISION REPAIR CERTIFICATE I COURSE DESCRIPTIONS. Total: 18 Credit Hours

COATING & WRAPPING OF UNDERGROUND PIPING

FIRESTOPPING & SMOKE SEALS

BLACK JACK ALL WEATHER ROOF COATING

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

Bella Cera Engineered Hardwood Flooring Installation Instructions. Check for Proper Color Selection Prior to Installation

Low viscosity, solvent free elastic adhesive for wood flooring

Aspect Metal Peel & Stick Tile Installation Guide

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

TECHNICAL DATA SHEET HAMMERITE METAL PAINT. Smooth Hammered Satin Aerosol

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco

Table of Contents Markers...1

SECTION FIRE HYDRANTS

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

Technical Data Sheet February 2014

K2 STONE NATURAL VENEER

SECTION 1081 COATING OF STRUCTURAL STEEL

Installation System. Existing Resilient Sheet Floors

SECTION 807 PUMP STATION REHABILITATION

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Congratulations! Quality products for quality floors

Crystal Clear Sealant

SECTION RESURFACING CAST IN PLACE CONCRETE

Solvent Cementing Instructions For Plastic Pipe & Fittings

Moisture Control. System Solutions to Prevent Mold

WOOD FLOORING MAINTENANCE MANUAL

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

Training Course Catalog

How to Install Hardwood Flooring Over a Sub Floor

Product Information. D8115 Matte and D8117 Semi-Gloss Clearcoat System

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

Document Library TS Data Sheet M Windo-Weld Super Fast Urethane. Data Sheet. Public

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

Transcription:

High Performance Acrylic Coating For Interior Wall Finishes FRESCO Guide Specifications FRESCO Guide Specifications

PART 1 GENERAL TRIARCH GUIDE SPECIFICATIONS SECTION 09960 FRESCO 1.01 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General Conditions, Special Provisions, and Specifications, apply to work of this section. 1.02 DESCRIPTION OF WORK A. EXTENT of wall/ceiling coating work is indicated on drawings and schedules, as herein specified. B. WORK INCLUDES (write a general description of the scope of work). The work also includes masking, protection of adjacent surfaces, priming, finishing, and cleanup of all coated areas throughout the project as designated on the drawings and finish schedules, except as otherwise specifically indicated. C. WORK SPECIFIED IN OTHER SECTIONS: Textured coatings, other specialty coatings, fire proofing, wall coverings, tile, paneling, fabrics, acoustical treatments, shop applied finishes and laminated plastics. 1.03 QUALITY ASSURANCE A. COMPATIBILITY: Provide primers and other undercoat materials which are produced or are specifically recommended by the same manufacturer as the finish materials to ensure compatibility and use only within recommended limits. B. COORDINATION OF WORK: Review other sections of these specifications in which prime paints, raw substrates, or other substances might be present to ensure compatibility of total coatings systems. Upon request from other trades, furnish information or characteristics of coating materials provided for use, to ensure compatible substrate materials and finishes are used. C. WARRANTY: Provide written 10-year Material Performance Warranty from manufacturer. 1.04 SUBMITTALS A. PRODUCT DATA: Submit manufacturer's technical information including installation instructions, product description, and product test data conforming to the test performances required herein. Rev. 3/10/09 2

B. SAMPLES: Prior to beginning work, Contractor shall provide Architect with a complete color set as furnished by the manufacturer for color selection purposes. After architect's color selection, Contractor shall provide three samples of each color of the specified coating applied to 10" x 12" hardboard for review. Apply materials in the same manner and with the same equipment as is to be used in the field. 1.05 DELIVERY AND STORAGE A. DELIVER MATERIALS to jobsite in original, new and unopened containers bearing manufacturer's name and label, and the following information: Name or title of materials, manufacturer's stock and/or batch number, date of manufacture, and contents of containers including color name and number. B. STORE MATERIALS not in active use in tightly covered containers. Maintain containers in a clean condition, free from foreign materials and residue. Protect from freezing and maintain temperatures below 100 F. Keep materials stored in an orderly and organized manner to reduce the risk of error. Do not stack materials more than three containers high. Protect from fire hazards. 1.06 JOB CONDITIONS A. APPLY materials only when surface temperature is between 60 and 95 F. Protect finishes from casual impact and rain for a period at least 24 hours after installation. Protect all surfaces and adjacent areas not intended to be coated and clean immediately any spillage, droppings, or other extraneous contact of the materials with other surfaces. B. Remove masking tape and clean all adjacent surfaces at the end of each work day. Do not leave masking tape or waste materials in place for more than eight (8) hours. PART 2 - PRODUCTS 2.01 MANUFACTURER Provide FRESCO as manufactured by TRIARCH, One Energy Way, West Warwick, RI 02893, 1-800-537-6111, www.triarchinc.com. 2.02 MATERIALS A. MATERIAL QUALITY: Finished and fully cured (28 days) Fresco materials shall have the following minimum performance characteristics: ASTM-E84 Flame Spread ASTM D2486.89 N/A for coatings less than 1/28 thick Rev. 3/10/09 3

Solvent Resistance: (1 hour soak) Water Detergent Ethanol Naphtha Ammonium Hydroxide Ethylene Glycol Bleach (household) Sodium Hypochlorite (Tile-X) Temporary softening Temporary softening Stain Resistance (10 hour soak and wash with 409 Cleaner and water) Water Blood Urine Coffee Tea Blueberry Mustard Bleach (household) Sodium Hypochlorite (Tile-X) Mark Resistance (marked 24 hour cure, wash with brush 409 cleaner and/or bleach) Pencil Ball point pen Rubber shoe heel Felt tip pen (non-permanent) B. SPECIFICATIONS: C. COLOR: Water-base pure acrylic resin Inorganic fillers 64.5% solids by volume Perm Rating: 17 perms, ASTM D1653 Film Thickness: 4 mils dry (6 mils wet) Color Pigments: All pigments shall be pure, non-fading, UV stable, and shall not contain heavy metal concentrations higher than allowed by governing regulations. Color Selection: Provide at least eighty factory colors and factory custom color service. Rev. 3/10/09 4

PART 3 - EXECUTION 3.01 INSPECTION Applicator shall examine areas and conditions under which coating work is to be applied and notify Contractor in writing of conditions detrimental to proper and timely completion of the work. Do not proceed with work until unsatisfactory conditions have been corrected in a manner acceptable to the applicator. 3.02 GENERAL A. Perform preparation and cleaning procedures in accordance with manufacturer's recommendations and as herein specified, for each particular substrate condition. B. Remove hardware, hardware accessories, machined surfaces, plates, lighting fixtures, and similar items in place and not to be finish coated, or provide masking or other protection prior to surface coating operations. Following completion of coating of each space or area, reinstall removed items. 3.03 SURFACE PREPARATION A. GENERAL: Provide masking or other protection prior to surface coating operations. Remove protection immediately following completion of each area. Clean surfaces to be coated before applying any materials. Remove dust, latency, form release agents, grime, dirt, oil and grease prior to application of any coating. Program cleaning and coating so that contaminants from cleaning process will not fall into wet or newly coated surfaces. Moisture content of the substrate may be up to 30% provided substrate can be reasonably expected to completely dry within forty-eight hours of application. Coating will remain uncured until full drying has been achieved. B. CEMENTITIOUS MATERIALS: Prepare cementitious surfaces such as unpainted/uncoated concrete, concrete block, cement plaster by cleaning as noted above and removing form release agents that might interfere with bond. Major holes, honeycombs, etc. to be filled with cement grout as specified under concrete elsewhere in these specifications. Grind, fill and float smooth all minor holes, joints, seams and other imperfections using SKIMM as manufactured by Triarch Industries. Allow SKIMM to dry 24 hours. Dampen dry plaster and concrete surfaces prior to installation of materials but wipe away any active condensation or water sufficient to cause a wet glaze. C. FERROUS METALS: Clean free of oil and surface contaminants with nonpetroleum based solvent. Prime all bare metal surfaces with a good quality rust inhibiting primer prior to application of any acrylic coating materials. Test adequacy of adhesion of primer to substrate prior to application of Fresco. Document test results. Rev. 3/10/09 5

D. WOOD, PLYWOOD, and PARTICLE BOARD: Remove dust, wax, oil and other surface contaminants that might interfere with bond. Seal all wood with a good stain-blocker/sealer. Use only oil based sealer on wood which has been treated with fire retardant salts. Test adequacy of adhesion of primer to substrate prior to application of Fresco. Document test results. E. GALVANIZED SURFACES: Clean free of oil and surface contaminants with nonpetroleum based solvent. Apply one coat of primer specifically designed for bonding to galvanized metal. Test adequacy of adhesion of primer to substrate prior to application of Fresco. Document test results. F. NEW DRYWALL: Prepare new drywall as required to meet industry standards for substrates to receive latex wall paint. Do not seal or prime the wall board in any manner except with materials recommended or supplied by the finish-coating manufacturer. G. EXISTING DRYWALL: Prepare to meet industry standards for a substrate that is to receive latex paint. If any areas of previously-painted existing wall have been repaired with fresh board and/or joint compound, then coat the repaired areas with one coat of Fresco and allow to dry before painting entire wall area. H. EXISTING DUROPLEX : Patch and repair the Duroplex wall surface in accord with Triarch s recommendations. Clean all other wall surfaces with light soap and water. Rinse soap from the surface with a light mist. Spot clean any remaining areas and rinse off cleaning agents. Fresco may be applied on the damp surface. 3.04 MATERIALS PREPARATION A. STIR MATERIALS before application with a power drill and paint paddle. Stir at approximately 350 RPM for three minutes while removing material from all sides and bottom of the container. Stir only as much material as will be used in a four hour period or re-stir material left sitting in excess of four hours. RETAIN lid on containers until the material is in actual use. Do not leave containers opened for more than one hour. If hardened material accumulates on the sides of the container, remove the material to clean container before use. B. THINNING: Should storage or shipping expose materials to excessively high or low temperatures, viscosity may be affected. See manufacturer's written instructions for thinning information. 3.05 APPLICATION A. GENERAL: Apply Fresco materials in accordance with the manufacturer's instructions and recommendations as required to achieve the appearance of the approved samples and performance as specified herein. Rev. 3/10/09 6

B. FINISH SCHEDULES: Surface treatments, and finishes, are indicated in "schedules" of the contract documents. Final finishes shall conform to the approved samples. C. MINIMUM FILM THICKNESS: Final dry film thickness shall be a minimum average of 4 mils (6 mils wet). Coat surfaces behind movable equipment and furniture same as similar exposed surfaces. D. COMPLETED WORK shall be uniform in appearance and coverage. It shall be free of holidays, spotting, laps, runs, sags, or other surface imperfections. E. COMPLETED WORK shall be uniform in appearance and coverage. It shall be free of holidays, spotting, laps, tool marks, runs, sags, or other surface imperfections. 3.06 CLEAN-UP AND PROTECTION A. CLEAN-UP: During progress of work, remove from site discarded coating materials, rubbish, cans, and rags at the end of each work day in compliance with all local, state, and federal requirements. B. PROTECTION: Protect work of other trades, whether to be coated or not, against damage by coating work. Provide signs, barricades, etc., as required to protect new work from damage by others (see General section of this division for curing times). Triarch P.O. Box 1014 One Energy Way West Warwick, RI 02893 800-537-6111 www.triarchinc.com Information contained in these application instructions conforms to standard detail and product recommendations for the installation of Fresco as of the date of publication of this document and is presented in good faith. Triarch assumes no liability, expressed or implied, as to the architecture, engineering or workmanship of any project. To insure that you are using the latest, most complete information, contact Triarch A Division of Dryvit Systems, Inc. Rev. 3/10/09 7