New Methods for Guidance of Light-Based Treatments Using Objective Melanin Measurements



Similar documents
Laser Tattoo Removal

MTOne. Taking care of people, our masterpieces. The Next Generation Multi-Source Platform IPL - Laser Er:YAG - Laser DIODE.

Case reports: Nordlys short pulse SWT treatment of: Port Wine Stains & Rosacea. (Comparison with Pulsed Dye Laser)

Innovative Low Fluence-High Repetition Rate Technology for Hair Removal

Explaining Ellipse I 2 PL

Objective: Conclusions: Introduction

A single device, a plethora of treatments.

Patient Information and Consent for Medical/Laser/Intense Pulsed Light Treatment. VASClinic PROCEDURES

LASER HAIR REMOVAL: SCIENTIFIC PRINCIPLES AND PRACTICAL ASPECTS

GentleMax Pro. Integrated Aesthetic Treatment System. Science. Results.Trust.

GentleYAG. Superior Results Treating Multiple Indications. Science. Results.Trust.

Long-Pulsed 1064-nm Nd:YAG Laser-Assisted Hair Removal in All Skin Types

Extended Theory of Selective Photothermolysis

VariLite Treatment Guidelines

Performance. All You Need. All In One.

Comparative Report for Aesthetic Laser / IPL Platforms Copyright MedicalSpaMD.com - All Rights Reserved Read our Terms

SHR Pain Free Hair Free

There are different types of lasers that according the wavelength of their beams have different indications; the most common ones used on skin are:

Optimizing the Efficacy and Comfort of Laser Hair Removal Treatment

Thomas T. Jeneby, M.D Wurzbach Suite 801 San Antonio, TX /

Treatment Guidelines

12/7/2014. Dr.Mohammad Alshami associate professor of dermatology Sana a university Yemen

Do home-use hair removal lasers & intense light devices deliver what they promise and are they safe?

DETERMINING WHICH COLOR UV BEAD CHANGES COLORS THE FASTEST

PowerLight LED Light Therapy. The FUTURE of corrective skin

Consent for Laser/Light Based Treatment

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2011/16

NEHSNORTH EASTERN HEALTH SPECIALISTS

Science > MultiClear. How the MultiClear works?

CLASS IV THERAPY LASERS

Avalanche FRAC3 Nd:YAG Laser Hair Removal

The Layman's Guide to ANSI, CEN, and ISO Bar Code Print Quality Documents

Vascular Treatment Guidelines

Safe and Effective Long-Term Hair Reduction in Tanned Patients Using an 800 nm Diode Laser

Evaluation of the Efficacy of Tattoo-Removal Treatments with Q-Switch Laser

Advanced Aesthetic Technology. X-Lase

Revision L Candela Proprietary Sheet 1 of 5 February 2005

What are spider veins? What is the best treatment for spider veins?

TEXAS DEPARTMENT OF STATE HEALTH SERVICES. Executive Summary. Report on Regulation of Laser Hair Removal

Study of Very Long-Pulsed (100 ms) High-Powered Diode Laser for Hair Reduction on All Skin Types

Freckles Removal Using Intense Pulsed Light in Chinese People

Smoothbeam Laser Treatment of Acne Vulgaris. Emerging Applications

LASER TREATMENT OF VASCULAR LESIONS

THE IMPOSSIBLE DOSE HOW CAN SOMETHING SIMPLE BE SO COMPLEX? Lars Hode

Treatment Guidelines

Laser treatment for the removal of unwanted Hair

FDA Cleared for Onychomycosis *

Corporate Medical Policy Laser Treatment of Port Wine Stains

Treatment of Freckles and Solar Lentigines Using A Long-Pulsed Alexandrite Laser in Asian Skin : A Pilot Study

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

INTEL S SAFETY WARNING LABEL REQUIREMENTS

Use of the LightSheer Diode Laser System for the Treatment of Benign Pigmented Lesions

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

EXPANDING YOUR HORIZONS

LASERs for vascular lesions. Mashayekhi vahid MD Dermatology Department Emamreza Hospital Mashhad-Iran

1W High Power Purple LED Technical Data Sheet. Part No.: LL-HP60MUVA

Laser and Cosmetic Center

Treatment of facial telangiectasias with a diode-pumped Nd:YAG laser at 532 nm

LZC-00MC40. LedEngin, Inc. High Luminous Efficacy RGB LED Emitter. Key Features. Typical Applications. Description

Lasers that emit short pulses of UV light in

Characterization of a New Light and Vacuum Device for the Treatment of Acne

SKIN CARE menu of services

APPLICATION NOTES: Dimming InGaN LED

Use of an 800 nm High-power Diode Laser for the Treatment of Leg Vein Telangiectasia

Epidermal Protection: A Comparative Analysis of Sapphire Contact and Cryogen Spray Cooling

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Discontinued. LUXEON V Portable. power light source. Introduction

Scientific Evaluation of VSP Nd:YAG Lasers for Hair Removal

Laser Hair Removal: Comparative Study of Light Wavelength and its Effect on Laser Hair Removal

ICON PRE AND POST OP INSTRUCTIONS. MAXG or 1540 (XD/XF)

Paint it cool! Pigments for solar heat management in paints

3528 SMD LED. Applications. Signal & Symbol Indicators. Illuminations(illuminated advertising & general lighting). Amusement Machines.

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Clinical Bulletin. Rethinking Selective Photothermolysis in Hair Removal. Thomas A. Sult and Robin Sult

A Novel Approach to Make an Objective Evaluation of Photo Skin Rejuvenation with Intense Pulsed Light

SKIN CANCER AND TANNING 101. Introduction. There are more than one hundred types of cancer. All the kinds of cancer begin in our cells.

N35L-U High Power LED

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Not suitable for Afro-Caribbean or black skin complexions.

Layman's Guide to ANSI X3.182

Biological and clinical aspects in laser hair removal

The upcoming new editions of IEC and ANSI Z136.1 examples on impact for classification and exposure limits

Outline. Quantizing Intensities. Achromatic Light. Optical Illusion. Quantizing Intensities. CS 430/585 Computer Graphics I

Fiber Optics: Fiber Basics

Luckylight mm (2.4") 8 8 RGB color Dot Matrix LED Displays Technical Data Sheet. Model No.: KWM-50884XRGBB

Paint Database Guide. Paint Database Guide. Color iqc and Color imatch Paint Database Guide. Version 8.0 July July 2012 Revision 1.

Save Face Laser & IPL Fact Sheet

Electromagnetic Radiation (EMR) and Remote Sensing

C S K L A S E R A E S T H E T I C C L I NI C ~ P R I CE M E N U ~

Color Balancing Techniques

Review Vocabulary spectrum: a range of values or properties

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July Reprinted from Photonics Spectra, Laurin Publishing

Forest Stewardship Council

Long-pulsed Nd : YAG laser: does it give clinical benefit on the treatment of resistant telangiectasia?

Thermopile Support: FAQs, Troubleshooting, Care & Maintenance

Cosmetic Laser Procedures and Facial Contouring with Injectables. 2009, American Society for Aesthetic Plastic Surgery

Laser Tattoo Removal. Birmingham Regional Skin Laser Centre

Non-Fractional Broadband Infrared Light for: Acne Scarring - Preliminary Results

Transcription:

New Methods for Guidance of Light-Based Treatments Using Objective Melanin Measurements Sean Doherty, MD, 1 Richard Cohen, PhD, 2 Felicia Whitney, RN, 2 Oksana Bradley, MD, 2 (Ukraine) Brooke Seckel, MD 1 1 Boston Plastic Surgery Associates, Concord, MA; 2 Palomar Medical Technologies, Inc., Burlington, MA Background and Objective: Historically, clinicians have used visual assessment and Fitzpatrick Skin Type (FST) scale to determine appropriate treatment settings for intense pulsed-light (IPL) treatments. We investigated the potential of melanin index (MI) objective measurements to guide IPL treatment using a new melanin reader device (Skintel Melanin Reader, Palomar Medical Technologies, Inc. Burlington, MA). Conclusions: The new Skintel Melanin Reader generates reproducible measurements of melanin in the skin and was observed to provide a clearly defined correlation between MI and skin tolerance reactions. This correlation enabled the development of an MI-based treatment guide that provides starting test spot fluences for IPL treatments. MI-correlated fluences were tailored to the specific indication and objective MI measurement within the treatment site to provide more customized treatment guidance as compared to FST-based treatment guidance. Introduction Based on the principles of selective photothermolysis, light energy delivered through lasers or intense pulsed-light (IPL) should be high enough to damage target tissue but low enough to avoid injury and excessive skin reactions in surrounding non-target tissue. Currently, visual assessment of skin in comparison to the Fitzpatrick Skin Type (FST) scale is the standard method used to guide selection of parameters for laser and IPL treatments, even though FST was originally intended to estimate dosimetry and response to ultraviolet light exposure. An individual s FST is based on eye color, hair color, and skin phototype and does not account for the current state of pigmentation, or melanin, in the skin. Given that melanin, hemoglobin, and water are the chromophores targeted in IPL phototherapy, we postulate that providing an objective measurement of melanin has the potential to provide the best guidance for selection of treatment parameters for most IPL treatments. During IPL treatment, the amount of heat absorbed in the epidermis and dermal/epidermal junction is dominated by and proportional to the amount of melanin present. For example, IPL treatment of a pigmented lesion (higher melanin content) will result in increased heating of the lesion as compared to the surrounding skin (lower melanin content). With an appropriate clinical IPL setting, there is sufficient heating to induce controlled damage in targeted cells resulting in removal of the damaged tissue through the natural healing processes of sloughing and turnover. Ideally, the significantly lower energy that is absorbed in the surrounding (non-target) tissue will not result in prolonged skin reactions or injury due to the lesser amount of chromophore content of this tissue. For this reason, we investigated the upper limit of fluence that can be tolerated in uniform skin using an objective measurement of the skin s melanin density or index, (MI). In this scenario, uniform skin is defined as the skin surrounding the targeted lesions that contains significantly lower levels of melanin and is relatively free of hair and pigmented or vascular lesions or other conditions. We postulate that correlating MI values to tolerable fluence levels in uniform skin will enable better treatment and site-specific guidance for IPL applications compared to current strategies based in part upon FST. Methods Study Design: Using the Skintel Melanin Reader, MI values were collected from 65 subjects ranging in age from 18 to 82 years, with an average age of 35 and FST from I to VI. Test spots were performed on an area of the back with uniform skin tone that was free of hair, vascular and pigmented lesions and other conditions. Three MI readings were recorded from each of five locations (corners and center) of the test spot area and averaged to establish an overall MI value. Subjects received an ascending series of 6 mm diameter test spots at pulse width settings of 3 1

to 80 milliseconds (ms) for Palomar s intense pulsed light handpieces. Clinicians graded the severity of these skin reactions at 30 to 45 minutes and at 24 hours after test spot application. The results of these test spot matrices are shown in Figure 1. Figure 2: Recording MI Value of Forearm Skin with the Skintel Melanin Reader. Figure 1: Test Spot Matrix in a Subject with FST II. A) Observed skin reactions at 30-45 minutes and B) 24 hours following test spot application. Observation of skin reactions to test spots: The Maximum Tolerable Fluence was defined as the highest fluence that yielded a skin reaction no greater than moderate erythema observed 24 hours after treatment. The skin reaction must also have completely resolved by the one week post-treatment observation. Device Description: The Skintel Melanin Reader (Figure 2) is a portable instrument intended for objective measurement of melanin in human skin. It utilizes measurements of skin reflectance at multiple wavelengths that are subsequently processed to yield a value that is proportional to the average skin melanin content over the measurement area. The Skintel reader contains a threewavelength LED that emits at 640 nm, 700 nm, and 910 nm. Reflected and scattered light from the skin is collected by a waveguide which is detected by a silicon detector located adjacent to the LED. Based on the three measured signals, a MI value is calculated, which ranges from 0 (very light skin) to 99 (very dark skin). Clinical Results As anticipated, a wide range in skin pigmentation was observed for a given FST (Figure 3). For example, individuals with a MI value of 14 to 19 could be classified under FST as a Skin Type II, III or IV. Figure 4 shows examples of the skin tone appearance of individuals with different ranges of MI values from light to dark. For all subjects, MI readings were higher on the forehead and lower on the cheeks. Figure 3: Range of MI Values per Fitzpatrick Skin Type. Abbreviations. FST: Fitzpatrick Skin Type; MI: Melanin Index; std: standard deviation; Min: minimum; Max: maximum 2

Figure 4: Representative MI Values for a Range of Facial Skin Colors. Results: Relationship between MI and skin tolerance to IPL treatment The Maximum Tolerable Fluence for each individual was determined and plotted as a function of MI for each combination of handpiece and pulse width. The scatter plots shown in Figure 5 for MaxG at 10 and 20 ms represent a subset of those generated for the handpieces. In each scatter plot, an individual s Maximum Tolerable Fluence was plotted (red squares) as a function of the individual s MI. Individuals with the lowest fluence settings were selected (highlighted with blue diamonds) and used to generate a smooth curve (fitted, universal setting threshold curve depicted by black line with green triangles) such that the Maximum Tolerable Fluence settings for all subjects fit on or above the curve. Figure 5: Scatter Plots for MaxG at 5 and 20 ms Pulse Widths Showing the Following: Each individual s maximum test spot fluence with acceptable side effects (skin reaction moderate erythema at 24hr and without lingering erythema at 1 week) plotted according to their MI. Selected individuals with the lowest fluence settings (high lighted with blue diamonds with solid white fill) were used to generate fitted threshold curve. The fitted threshold curve, black line with green triangles - all individual s observed maximum test spot settings with accept able side effects fit on or above the curve. The Skintel fluence value curve (blue line) was obtained by subtracting an additional safety margin. 3

Figure 6: Melanin Index (MI) Guidance of Palomar Icon FST Treatment Guide Max G FST MI Vascular Lesions PW (ms) I-II <20 Red facial vessels > 0.3 mm 10 20 III 20-30 Red facial vessels > 0.3 mm 10 20 IV 31-39 Red facial vessels > 0.3 mm 20 IPL handpieces using the Skintel Melanin Reader. For the clinician, practical use of MI as guidance for treatment parameters not only involves selection of the appropriate handpiece and pulse width settings for the intended indication, but also assessment of the skin within the treatment area throughout which skin tone may vary. By performing MI readings in the region of skin with the darkest uniform (homogenous) skin color, and using this area to assess settings, this will ensure that the treatment will be appropriate throughout the entire treatment area. Because the Skintel reader averages the MI value over the entire optical window (6 x 12 mm), the measurement area should be as free as possible of potential chromophores, hair, pigmented lesions and tattoos. Inclusion of any of these items results in a higher MI value which would subsequently lead to lower, less effective guidance settings. Once the MI value is obtained, the clinician should consult the Palomar Icon Treatment Guide to select the handpiece-appropriate pulse width for the indication being treated. For example, for the MaxG, per Figure 6, either a 10 or 20 ms pulse width is recommended for treatment of red facial vessels measuring 0.3 mm or more in diameter. Once MI and pulse width have been entered into the Palomar Icon, the Skintel Value (J/cm 2 ) is identified from an internal lookup table for the handpiece. This Skintel Value represents a starting fluence value for test spots. Use of test spots is essential for establishing appropriate treatment settings and should include assessment of skin reactions in both the target and non-target area. As with all recommendations, the clinician must also apply his/her best clinical judgment when selecting a starting test spot value. In addition to the recommended Skintel Value, consideration of the patient s FST, a visual assessment of the patient s skin, the patient s ethnicity, medical history, recent tanning and history of sun-exposure should also be factored in determining appropriate starting test spot fluences. Discussion Successful light-based treatment of dermatologic indications entails appropriate damage and clearance of the intended target tissue with minimal impact to surrounding tissue. Results from extensive test spot testing were used to establish a relationship between melanin content measured using the Skintel reader and Palomar Icon s IPL handpiece parameters. The established relationship for each handpiece was then used to generate a lookup table of fluence values based upon MI values for each pulse width setting. These Skintel Values are now provided to the user as a starting fluence for guidance of test spots. One of the major benefits of an MI-based treatment guide is that the MI value is specifically correlated to each IPL handpiece. Defining treatment parameters based on FST-guidance alone runs the risk of reduced efficacy or increased side effects due to the lack of consideration of the skin s melanin density. When using FST alone, treatment guidance needs to consider the darkest individual or most sensitive type of individual within that level of FST to ensure the safety of recommended settings. In reality, as our measurements have shown, the wide range of MI values highlights the challenge of finding a universally appropriate setting based on FST alone. In addition, treatment areas within the same person can vary in skin tone depending on the degree of lifelong and recent sun exposure. Using an objective MI-based form of guidance allows for the determination of starting test spot fluences that are specific to the individual and to the treatment area. Other benefits of an MI-based guide are its objective form of measurement that will provide consistent measurements over time and across different users. For clinicians with less IPL experience, this method provides a faster learning curve enabling more consistent treatment outcomes. And importantly, this method enables clinicians to track sun exposure and tanning history in individuals between treatments to more objectively evaluate appropriateness of reusing prior treatment settings. Given these benefits, we predict that it will soon be considered best practice to incorporate an accurate reading of melanin reading into the evaluation and determination of treatment strategies. There are several issues to consider regarding the use of an MI-based treatment strategy based upon skin tolerance reactions of uniform skin. One issue is that determining appropriate clinical treatment settings requires not 4

just an assessment of skin tolerance around the target, but also an assessment of skin tolerance within the target lesion; these assessments require expert evaluation of clinical endpoints specific to the type of lesion being treated. A second factor to consider is that the Skintel reader measures average MI content over the entire optical window. Use of the MI measurement of the target as a basis for guidance would not be appropriate for vascular conditions since the primary target chromophore for these indications is hemoglobin, not melanin. For hair and pigmented lesions the sparsity and variation in concentration within the lesion would limit the ability to accurately measure melanin content. Another caveat is that certain conditions in the skin surrounding the target lesion (e.g. melasma, diffuse erythema, psoriasis, etc.) may potentially compromise the ability of the skin to tolerate treatment settings; in these instances, clinicians should proceed with caution before using Skintel Values as guidance for test spot settings. In light of these exceptions, when used appropriately, the Skintel reader can provide meaningful guidance for light-based treatments by narrowing the range of test spots and providing increased confidence in the selection of settings. Summary The relationship between Skintel Melanin Reader MI values and the Palomar Icon s IPL handpiece parameters was used to establish a new MI-based treatment strategy. This represents a major advancement over FST-based guidance. Objective MI-based guidance allows for customization of recommended treatment s starting test spot fluence that are specific to the individual s current skin condition in the treatment area and indication. 2011 Palomar Medical Technologies, Inc. Palomar is a registered trademark and Skintel and MaxG are trademarks of Palomar Medical Technologies, Inc. ALL RIGHTS RESERVED. 5