Measurement Standards for Structures



Similar documents
Applies to: All Employees within the Facilities Management Department (FMD)

NUMBER EFFECTIVE DATE. July 23, 2003

Table of Contents. I Introduction 2. II Definitions & Area Calculation 2. III Room Numbering 7. IV Appendix A 9

The Impact of Building Shape on Space Planning Efficiency By Randall Walker, AIA, Executive Vice President, Kirksey

June 7, 2010 Page 1 of 5

Professional Office Building 910 North Main Street Site Size: +/- 43,560 Square Feet

Professional Property Management TREC 4507

Building Code Clarifications - 7. Fire Resistance

Real Property Performance Results

STANDARD METHOD FOR MEASURING< FLOOR AREA IN OFFICE BUILDINGS

Excerpts from the Canadian National Building Code (NBC)

Building Measurement Services

New York City Department of Buildings

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Special Use Commercial Properties

Schedule B to By-law Part A Fees Payable for Permits

Lower Level (Level L) Exhibit Halls A, B & C

San Diego Convention Center Floor Plans

National Business Space Assignment Policy. GSA Public Buildings Service Office of Real Property Asset Management February 2013

Sec Home occupation.

Ministry of the Environment Decree. on housing design

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

Measuring Single Family Dwellings Town homes Condominium Units. P) ~ F)

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

Certification: Building Plans Examiner. Exam ID: B3

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

City of Riverside Building & Safety Division Phone: (951)

Schedule B to By-law

ENERGY STAR Data Verification Checklist

2012 CEEI Floor Area Methodology - Residential, Commercial, and Industrial Buildings

Calculating Commercial Real Estate Rent. An E-book Prepared By:

Commercial Building Valuation Report

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

DESIGN REVIEW CHECKLIST Chapter 6 Special Consideration Design Guidelines

Code Requirements for Existing Buildings

Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet

The WCO Guide to: A Glossary of Workplace Terms. The Workplace Consulting Organisation. Occasional Paper OP2 January 2013, v1.0

Residential Decks. Planning and Development Services Department

Saint Cloud Business Center

PRODUCT AND ENGINEERING MANUAL

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

MEANS OF EGRESS CHAPTER 10

560 CMR: STATE 911 DEPARTMENT 560 CMR 4.00: REGULATIONS GOVERNING ENHANCED 911 SERVICE FOR MULTI-LINE TELEPHONE SYSTEMS

BUILDING PERMIT SPECIFICATIONS

BROWNSVILLE STRUCTURES STUDY. July Prepared by. LDA ARCHITECTS 33 Terminal Way, Suite 317 Pittsburgh, Pennsylvania

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

MEANS OF EGRESS CHAPTER 10

HOMEOWNER S PERMIT GUIDE

PAGE INTENTIONALLY LEFT BLANK

PORT OF SEATTLE MEMORANDUM. COMMISSION AGENDA Item No. 6a ACTION ITEM Date of Meeting January 6, 2015

Schematic Design: Quality Management Phase Checklist Project Phase Checklist Series

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

Commercial Building Valuation Report

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R

Fire-Retardant-Treated (FRT) Plywood

How To Build A Basement House

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

TYPES OF PROPERTIES ARE INCLUDED WITHIN THE T3 TRANSECT DESIGNATION?

CITY OF CHICAGO SMALL BUSINESS IMPROVEMENT FUND (SBIF) PROGRAM RULES

Exterior Elevated Elements Inspection Guidelines

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Canada. What s Typical? CBRE Offices. For More Information

Industrial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

DEPARTMENT OF AIRPORT OPERATIONS CLEANING SCHEDULE FOR CONTRACT 2014

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

MEANS OF EGRESS CHAPTER 10

COMMERCIAL LEASING CHECKLIST

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

8/18/14. Introduction to. Framing. Terminology and Concepts

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

PLANNING DIVISION STAFF REPORT February 23, Summary. Background Information PREPARED FOR THE PLAN COMMISSION. Legistar File ID # 36810

MEANS OF EGRESS CHAPTER 10

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

STATE OF MINNESOTA. BIM GUIDELINE State of Minnesota s Facilities Administration Data Capture Plan

2010 ADA Standards for Accessible Design. Department of Justice

Residential Deck Safety, Construction, and Repair

29 Broadway- 14 th Fl Tel: New York NY Fax: Due Diligence Report. New York, New York

Site Development Information Worksheet for single family residential development

3901 Calverton Boulevard Beltsville, Maryland

Maximum Floor Area and Maximum Development Area

THE SKYSCRAPER MUSEUM DBQ DOSSIER 2. tools for teaching student guide BOOM & BUST: SKYSCRAPERS & SPECULATION s HISTORICAL CONTEXT TASK

KBC Chapter 34 : Applying the Kentucky Building Code to Existing and Historic Buildings

Single Family Residential Building Permit Questions & Answers

Office Space Standards and Guidelines

SECTION XI OPINION OF PROBABLE COST

PUBLIC RESTROOMS, DESIGN INTENT

Transcription:

DALLAS/FT. WORTH INTERNATIONAL AIRPORT Measurement Standards for Structures November 2002 Updated: September 2003 Planning & Real Estate Department

Table of Contents Standards for Measurements of Constructed Areas Page Part I: Terms............................................................ 1 Part II: Area Limits Exterior Walls........................................................... 2 Gross Building Area...................................................... 3 Total Interior Area........................................................ 4 Rentable Area.......................................................... 5 Usable Area............................................................ 6 Tenant Lease Area....................................................... 7 Part III: Specific Conditions in Airline Terminals Concessions.......................................................... 8 Airline Ticket Counter.................................................... 9 Baggage Claim......................................................... 10 Gate Lounge.......................................................... 11 Page i

Part One - Terms DFW Airport has established the following standards for defining and measuring area in constructed facilities. Designers and engineers shall use these standards to refer to and calculate the square footage of constructed areas when producing information for airport use. Part I: Terms Common building support areas: are rooms or spaces that support the overall operations of the building including public areas shared by the tenants of the building. These areas include janitorial, maintenance functions, mechanical, electrical, fire protection, public restrooms, building lobbies, multi-tenant corridors, and building storage. These spaces are enclosed with core walls. Core walls: are the walls surrounding common building support areas. Due to their permanent nature they are typically constructed of concrete masonry block, concrete, and/or drywall. These walls may be sound-proofed or firerated, therefore future tenant leasehold improvements should not penetrate, alter, or disturb their construction assembly. The total thickness of these walls is included in the area of the support area. Tenant Lease Areas are typically calculated to the face of these walls. Demising walls: are the walls that separate one tenant lease area from another. The thickness of this wall (regardless of actual dimension) is shared between the two spaces; therefore each tenant lease is measured to the centerline of this wall. Dominant portion of exterior wall: refers to the inside surface of a building's exterior wall construction. When this surface is not constant due to windows or varying wall types, the condition that occurs most will determine the dominant portion. Gross Building Area: refers to the total "constructed area "of a building measured to the outside face of the exterior walls. Atriums openings in the floor plates are NOT included. Since this area calculation is typically used to determine occupancy capacity, exterior occupied spaces such as balconies, decks, or terraces located above the ground floor are included in the calculation as floor area. Gross building area encompasses all other space definitions and is always greater than the total sum of sub areas due to the inclusion of the exterior wall and exterior occupied areas. Lease line: the boundaries of a Tenant Lease Area are defined by the lease lines. Due to recessed entries, irregular wall configurations, furred-outs elements, and/or setback requirements the lease lines may not necessarily be the same as the constructed perimeter walls. Major vertical penetrations: are penetrations in the floor plate required to support the general building functions such as fire stairs, elevators, mechanical shafts. Minor chases or floor penetrations for plumbing, communications, electrical routing are NOT included in this definition. Rentable Area: refers to the Total Interior Area excluding any major vertical penetrations (fire stairs, elevators, shafts). No deductions shall be made for columns, or minor floor penetrations or mechanical/electrical/plumbing chases. The area of these penetrations shall include the thickness of the wall encompassing them since these are typically core walls. Tenant Lease Area: this area is a specific portion of the Usable Area assigned to a Tenant. The wall separating one Tenant Lease from another is a demising wall. The space shall be measured to the centerline of these demising walls. In some cases the Tenant's Leasehold Improvements may not cover the total available area, however, the Tenant Lease Area is NOT reduced. This may occur due to recessed entries, irregular wall configurations, furredouts elements, and/or setback requirements. Total Interior Area: refers to the total area enclosed within the building's exterior walls excluding atriums openings and is measured to the inside face of the dominant portion of the exterior building walls. When the exterior wall slopes inward or outward the measurement shall be taken at the floor surface. Usable Area: refers to the Rentable Area with common building support areas excluded. The area of these elements shall include the thickness of the wall encompassing them since these are typically core walls. Page 1

Part Two - Measuring Areas Part II: Measuring Areas Except for the Gross Building Area, all areas are measured to the inside face of the dominant portion of the exterior wall. Dominant portion of exterior wall refers to the inside surface of a building's exterior wall construction. When this surface is not constant due to windows or varying wall types, the condition that occurs most will determine the dominant portion and if the exterior wall slopes inward or outward the measurement is taken at the floor surface. Refer to Diagram 2.1 for an illustrated examples. WALLS DIAGRAM 2.1 Page 2

Part Two - Measuring Areas Gross Building Area: refers to the total "constructed area" of a building measured to the outside face of the exterior walls. Atrium openings in the floor plates are NOT included. Since this area calculation is typically used to determine occupancy capacity, exterior occupied spaces such as balconies, decks, or terraces located above the ground floor are included in the calculation as floor area. Gross building area encompasses all other space definitions and is always greater than the total sum of sub areas due to the inclusion of the exterior wall and exterior occupied areas. Refer to Diagram 2.2 for an illustrated example of Gross Building Area. GROSS BUILDING AREA DIAGRAM 2.2 Page 3

Part Two - Measuring Areas Total Interior Area: refers to the total area enclosed within the building's exterior walls excluding atrium openings and is measured to the inside face of the dominant portion of the exterior building walls (refer Diagram 2.1 for illustrated examples). When the exterior wall slopes inward or outward the measurement shall be taken at the floor surface. Refer to Diagram 2.3 for an illustrated example of Total Interior Area. TOTAL INTERIOR AREA DIAGRAM 2.3 Page 4

Part Two - Measuring Areas Rentable Area: refers to the Total Interior Area excluding any major vertical penetrations (fire stairs, elevators, shafts). No deductions shall be made for columns, or minor floor penetrations or mechanical/electrical/plumbing chases. The area of these penetrations shall include the thickness of the wall encompassing them since these are typically core walls. Refer to Diagram 2.4 for an illustrated example of Rentable Area. RENTABLE AREA DIAGRAM 2.4 Page 5

Part Two - Measuring Areas Usable Area: refers to the Rentable Area with common building support areas excluded. The area of these elements shall include the thickness of the wall encompassing them since these are typically core walls. Common building support areas are rooms or spaces that support the overall operations of the building including public areas shared by the tenants of the building. These areas include janitorial, maintenance functions, mechanical, electrical, fire protection, public restrooms, building lobbies, multi-tenant corridors, and building storage. Refer to Diagram 2.5 for an illustrated example of Usable Area. USABLE AREA DIAGRAM 2.5 Page 6

Part Two - Measuring Areas Tenant Lease Area: this area is a specific portion of the Usable Area assigned to a Tenant. The wall separating one Tenant Lease from another is a demising wall. The space shall be measured to the centerline of these demising walls. In some cases the Tenant's Leasehold Improvements may not cover the total available area; however, the Tenant Lease Area is NOT reduced. This may occur due to recessed entries, irregular wall configurations, furred-outs elements, and/or setback requirements. The boundaries of the Tenant Lease Area are defined by lease lines. Refer to Diagram 2.6 for an illustrated example of a Tenant Lease Area. TENANT LEASE AREA DIAGRAM 2.6 Page 7

Part Three - Specific Conditions in Terminals Part III: Specific Conditions in the Airline Terminals Within the Airline Terminal buildings there are a number of unique areas that shall be addressed as follows: Refer to the Concession Program's Tenant Design Handbook for references regarding Kiosks, wall huggers, and Neighborhood areas. Concessions: The area leased as a concession space shall be Tenant Lease Area (as defined within this document) or as established by the Concessions Program. Area leased for freestanding kiosks, wall huggers, carts, etc. shall be defined by the Concessions Program. The following rules have been established to locate the "Front" of the lease line that faces the concourse area. Refer to the Concession Program's Tenant Design Handbook, Section 1.6 for detailed information and diagrams. Terminal A: The front lease line shall be located 4" back from the face of the column positioned on column line "C". Terminal B: The front lease line shall be located 4" back from the face of the column positioned on column line "C". The front lease line for concessions located on the opposite side of the concourse shall be located 4" back from the face of the column positioned on column line "D". Terminal C: The front lease line shall be located 4" back from the face of the column positioned on column line "C". Terminal E: The front lease line shall be located 4"back from the face of the column positioned on column line "C". The front lease line for concession on the opposite side of the concourse shall be located 4" back from the face of the column positioned on column line "D". Special conditions that exist in the above terminals, Satellite A-1, Terminal B expansion, and the Terminal E Satellite shall be defined by the Concessions Program. Page 8

Part Three - Specific Conditions in Terminals Airline Ticket Counter: The Tenant Lease Area associated with this function shall extend from the centerline of the backwall to 15 feet in front of the counter to accommodate queue lines. On the sides, the area shall extend to physical construction or features which create the limits of the function. Refer to Diagram 3.1 for an illustrated example. AIRLINE TICKET COUNTER DIAGRAM 3.1 Page 9

Part Three - Specific Conditions in Terminals Baggage Claim: The Tenant Lease Area associated with this function shall include the designated carousel devices and extend beyond to the physical features which create the limits of the waiting area or the "baggage hall", including any baggage service office/counter functions. Where there is more that one carousel the lease line shall be located at the centerline between two devices. Refer to Diagram 3.2 for an illustrated example. BAGGAGE CLAIM DIAGRAM 3.2 Page 10

Part Three - Specific Conditions in Terminals Gate Lounge: The Tenant Lease Area associated with this function shall extend from the inside face of the exterior building wall to the outside face of the column line separating the gate lounge from the concourse. On the sides the area shall extend to physical construction or features which create the limits of the function. It shall include the gate podium, backwall, mini-ops, and any other functions associated with the gate boarding process. Refer to Diagram 3.3 for an illustrated example. GATE LOUNGE DIAGRAM 3.3 Page 11