BD PhaSeal System. Product Catalogue

Similar documents
Helping to protect you from exposure to hazardous drugs

I.V. Administration Extension Sets / Gravity Administration Sets

SIGMA Spectrum Infusion System Compatible Baxter IV Sets

Cyto-Set. Safer cytostatic preparation and application. IV Administration

Product Catalog. WalkMed Infusion, LLC 6555 S. Kenton Street Ste. 304, Centennial, CO walkmed.net. Order Toll Free:

Resistance of Plastics to Gamma Irradiation

Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home

Components Catalogue. for I.V. giving sets, blood giving sets, and other medical devices

Sterilization methods and equipment Lab 1-2

Covering the Spectrum

BD Saf-T-Intima. Hidden talents of BD Saf-T-Intima. BD SAF-T-Intima and SUBCUTANEOUS THERAPY REHYDRATION PALLIATIVE CARE. POST OPERATIVe PAIN RELIEF

Kimberly-Clark Healthcare Catalogue Digestive Health. Digestive Health

Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION

A Global Leader in Hypodermic Products

Good practice for the preparation of injectable medicines in clinical areas

Disposables the Original by B. Braun

Hypodermic Product Catalog. The Basis for Selection of Your Medication Delivery Device Needs

No. X ISSUED: APR. 22, 2008 REVISED: MAY. 9, 2009 SERVICE INFORMATION : --- HOSHIZAKI WATER ELECTROLYZER ROX-20TB-E MODEL PARTS LIST

Safety. matters. CryoMACS Products

ON-Q * Catheters and Introducers

EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS

WHATMAN ÜRÜN LİSTESİ 1 / 53 KATALOG NO AMBALAJ ŞEKLİ. Labsciences

Cables. Accessories. For Force, Torque and Strain Sensors

Plasmax Plasma Concentration System BIOLOGICS

ReadyKart Mobile Processing Station Instructions for Use

Peripheral Venous Catheter Placement Simulator

RADIATION CONTROL TECHNIQUE #2 INSTRUCTIONS FOR PREPARATION OF RADIOACTIVE WASTE FOR DISPOSAL

Promoting safer use of injectable medicines

Procedure Code A Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external

SECTION. BD Medical Anesthesia Products - Trays For additional product information, visit us online at

Red rubber all-purpose urethral. Catheters. Bard Clean-Cath Intermittent catheter: Fr. 100/case

ResMed Mask Materials January 2009

5:00 GUIDELINES FOR ORDERING, PREPARATION, DISPENSING, HANDLING, AND DISPOSAL OF

TUBING LEADER IN FLUID MANAGEMENT

Effect of Sterilization Techniques on Polymers

Recognised Zebra Printing Systems

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

Cytotoxic and Biotherapies Credentialing Programme Module 6

PROCESSING OF VARIOUS MATERIALS

Newloc Acetal. Plastic Push-to-Connect Fittings. Fluid Transfer Specialists

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2011/38

Anesthesia Products Needles. Anesthesia Products Trays. Antimicrobial Products. Hypodermic/Diabetes Care Products. Hypodermic/Reusable Products

James M. Pleasants Company

Safe medication. Disposable syringes

I-140 Venipuncture for Blood Specimen Collection

I.V. Administration I.V. Placement / Miscellaneous / Needle-Free Systems

Needles and Syringes Prefilled I.V. Flush Syringes, Blood Collection and Sharps Disposal Products

Instructions for Use HUMALOG KwikPen insulin lispro injection (rdna origin)

HSL-VS Vials + Syringes

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

MEDICATION DELIVERY. Specialty Pharmaceuticals & Fluid Systems Catalogue. March, Helping to Save and Sustain Lives

Cytotoxic Agents Safe Management For Nursing Students. Pat Stalker Clinical Educator, LRCP Feb 2015

HUMULIN 70/30 KwikPen

syriq Glass Prefillable Syringes

Glossary. 3D Animation Using computer software to create and animate a three-dimensional representation of image data.

RUBBER SLEEVE KNIFE GATE VALVE

Flow Solution Parts & Accessories

Baxter Elastomeric Pumps CLINICIAN GUIDE

AQUATIC ANIMAL MEDICINE RECORD BOOK

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

Recommendations for the Safe Use of Handling of Cytotoxic Drugs

ResMed Mask Materials December

Syringe. Product Usage Information: Precautions:

, 38F,

8 GENITOURINARY Order inquiries? Items may not be exactly as shown. Foley Catheters

Power Injectors for Diagnostic Imaging

Instruments and accessories

Mechanical shaft seal types and sealing systems

1. Injection Molding (Thermoplastics)

NursE GuidEliNEs NURSE GUIDELINES

PRESSURE FILTRATION

The specialists in single-use. Refractive

SUCTION, ASPIRATING TUBES

How To Store An Acam2000 Vaccine

Waste Oil Handling, Spill Containment & Lighting

Plasmax Plasma Concentration System for Laparoscopic Roux-en-Y Gastric Bypass

Instructions for Use

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Your Best Choice For Laboratory Consumables

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs

Hose and Tube Fittings Series 1-3

Cautionary Information

PP / PE X X X X (X) X PA (X) X

Full Technical Catalog For Closed-loop Sampling System

World Class Equipment worldwide Edition J

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1

Lenntech Tel Fax

INSTITUTIONAL POLICY AND PROCEDURE (IPP) Department: Manual: Section:

The Arrow SureBlock Spinal Anesthesia Collection:

A Correct. The D in the order means dextrose which provides calories.

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Assembly instructions VOSS quick connect system 246 NX

AUTOMATIC BATTERY FILLING SYSTEM

Patient Information. PORT-A-CATH Implantable Venous Access Systems

Needlestick Injury Prevention Assessment Tool

HEALTHCARE Single - Use Systems CONTRACT MANUFACTURING SOLUTIONS PARTNER

This course was written for RN.ORG by an outside consultant and RN.ORG has rights for distribution but is not responsible for the contents.

1/29/2008 DR70. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 43

Transcription:

BD PhaSeal System Product Catalogue

BD PhaSeal is a clinically proven closed-system drug transfer device that prevents hazardous drug interaction exposure. This product catalogue contains information regarding the different components of the BD PhaSeal system. Whether you are to prepare a drug for administration by infusion or by injection, the BD PhaSeal system offers the range of products to meet your safe handling requirements. Product overview Preparation vial to syringe Preparation IV bag access Options depending on drug dose volume and/or vial necksize. Options depending on type of administration. Protector (P14) Infusion Set (C50) Protector (P21) Secondary Set, Drip Chamber (C60) Protector (P28) Secondary Set (C61) Protector (P50) L Connector (C90) Protector (P53) Infusion Adapter (C100) The product range may vary between different markets.

Administration IV line access Contents Drug vial access device BD PhaSeal Protector...4 5 Options depending on type of administration Syringe safety device BD PhaSeal Injector....6 7 BD PhaSeal Administration products...6 9 BD PhaSeal Application products...10 Connector Luer Lock (C35) Material specification...11 Injector Luer (N30C) Injector Luer Lock (N35) Connector Luer Lock (C45) Y-Site Connector (C80)

BD PhaSeal Protector The Protector is a pressure equalisation device which is permanently attached to the vial. It is used in the preparation of drugs from either powder or liquid form. The Protector establishes and maintains neutral pressure when air or fluid is injected into or aspirated from the vial. Material specifications, see page 13.

Drug vial access device BD PhaSeal Protector Protector (P14) REF 515100 Vial adapter for closed reconstitution and pressure equalisation. For drug vials with neck Ø13 mm. When attached to a vial, Protector (P14) has an equalising capacity of 20 ml of air. Protector (P21) REF 515102 Vial adapter for closed reconstitution and pressure equalisation. For drug vials with neck Ø20 mm. When attached to a vial, Protector (P21) has an equalising capacity of 20 ml of air. Protector (P28) REF 515104 Vial adapter for closed reconstitution and pressure equalisation. For drug vials with neck Ø28 mm. When attached to a vial, Protector (P28) has an equalising capacity of 60 ml of air. 25 pcs 100 pcs Protector (P50) REF 515105 Vial adapter for closed reconstitution and pressure equalisation. For drug vials with neck Ø20 mm. When attached to a vial, Protector (P50) has an equalising capacity of 50 ml of air. 25 pcs 100 pcs Protector (P53) REF 515107 Vial adapter for closed reconstitution and pressure equalisation. For drug vials with neck Ø32 mm. When attached to a vial, Protector 53 has an equalising capacity of 50 ml of air. 25 pcs 100 pcs 5

BD PhaSeal Injector The Injector ensures a closed transfer of the drug by means of double, elastomeric membranes. Material specifications, see page 13. BD PhaSeal Administration products IV line access BD PhaSeal administration products ensure closed transfer to infusion bags and closed administration of the drug via the patient s IV line. Material specifications, see page 13.

Syringe safety device BD PhaSeal Injector Injector Luer (N30C) REF 515001 Transfer device that attaches to a disposable syringe with standard Luer connection. With cap. Injector Luer Lock (N35) REF 515003 Transfer device that attaches to a disposable syringe or IV tubing with a standard Luer Lock connection. BD PhaSeal Administration products IV line access Connector Luer Lock (C35) REF 515200 Attaches to the patient s IV line, providing a closed connection to the Injector. Standard Luer Lock connection. Connector Luer Lock (C45) REF 515202 Attaches to the patient s IV line, providing a closed connection to the Injector. Standard Luer Lock connection. This Connector is designed for use with needle-free ports with internal pistons. Y-site Connector (C80) PHT REF 515304 Extension tubing with in-built BD PhaSeal Connector. Total length: 21 cm. Priming volume: 1.6 ml. 30 pcs 120 pcs 7

BD PhaSeal Administration products IV bag access Material specifications, see page 13.

BD PhaSeal Administration products IV bag access Infusion Set (C50) PHT REF 515300 Standard IV infusion set with in-built PhaSeal Connector for closed transfer to IV bag. Total length: 188 cm. Priming volume: 17.5 ml. Inline filter: 15 µm. Drops/ml: 20. 80 pcs Secondary Set, Drip Chamber (C60) PHT PHT REF 515301 Secondary set with in-built BD PhaSeal Connector for closed transfer to IV bag. Total length: 102 cm. Priming volume: 12.5 ml. Drops/mL: 20. 20 pcs 80 pcs Secondary Set (C61) REF 515302 Secondary set with in-built PhaSeal Connector for closed transfer to IV bag. Total length: 49 cm. Priming volume: 3.0 ml. 30 pcs 120 pcs L Connector (C90) REF 515305 The L Connector provides a dry connection for closed transfer of hazardous drugs to semi-rigid plastic containers with rubber ports. PVC-free. Infusion Adapter (C100) REF 515306 Connection between IV bag and non vented infusion set. In-built BD PhaSeal Connector for closed transfer to IV bag. PVC-free. 9

BD PhaSeal Application products Assembly Fixture (M12) REF 515400 Mechanical device used for consistent and simple attachment of a Protector to a drug vial. Non-sterile. 1 pc Syringe Tray (M15) REF 515401 The Syringe Tray is used to transport the filled syringe to the administration area. Designed to accommodate 1 30 ml syringes with Injector Luer Lock (N35). Non-sterile. 120 pcs Infusion Clamp (M25) REF 515403 Clamp for securing the connection of Injector Luer Lock (N35) to the Connector. Non-sterile. 25 pcs 100 pcs Cap for Injector membrane (M50) REF 515404 Protects membrane on Injector from direct contact with contaminated surfaces during transport and storage. Hanger for IV-bag (M55) REF 515405 40 pcs 160 pcs 12

Material specification BD PhaSeal Protector (P14/ P21/ P28/ P50/P53) Protector REF 515100/ 515102/ 515104/ 515105/515107 COMPONENTS Expansion film Hydrophobic filter Filter cover Housing Cannula (P14, P21, P50, P53) Protective lid (P14, P21, P50, P53) Protective lid (P28) MATERIAL PA/ PTFE BD PhaSeal Injector (N30C/ N35) Injector Luer Lock REF 515001/515003 COMPONENTS Cannula Cylinder Piston/Cannula housing Safety sleeve Piston sealing Locking washer (N30C) Protective cap (N30C) Stainless steel MATERIAL Stainless steel POM Silicone Stainless steel BD PhaSeal Administration products Connector Luer Lock (C35/ C45) REF 515200/ 515202 COMPONENTS Housing Protective cap Infusion Set (C50) REF 515300 Protective cap Spike Connector Chamber Liquid filter Tubing Roller clamp Male Luer Lock Protective cap with Flow Stop MATERIAL /SEBS PA PVC (DEHP-free) / Secondary Set, Drip Chamber (C60) REF 515301 Protective cap (spike) Spike Connector Drip chamber PVC (DEHP-free) Tubing PVC (DEHP-free) Roller clamp Male Luer Lock Protective cap with Flow Stop Infusion Set (C61) REF 515302 Spike Connector Chamber /SEBS Tubing PVC (DEHP-free) Clamp Rotating collar Male Luer Lock Protective cap with Flow Stop Y-Site Connector (C80) REF 515304 Protective cap, female Luer Lock Female Luer Lock Tubing PVC (DEHP-free) Slide clamp Connector housing Y-Site Rotating collar Male Luer Lock Protective cap with Flow Stop L Connector (C90) REF 515305 Connector housing Protective cap Infusion Adapter (C100) REF 515306 Protective cap Spike housing Spike port DEHP PA POM PVC PTFE SEBS Acrylo-nitrile butadiene styrene copolymer Di (2-ethylhexyl) phthalate Polyamide Polyethylene Polyoxymethylene Polypropylene Polyvinyl chloride Polytetrafluoroethylene Styrene-ethylene-butylenestyrene Thermoplastic elastomer Key to symbols Sterilised using ethylene oxide Do not re-use Latex-free DEHP-free -free 11

Consult your local BD sales representative for ordering information or visit us online at www.bd.com Consult instructions for use. BD, BD Logo and BD PhaSeal are trademarks of Becton, Dickinson and Company. 2012 BD MED061283. SW 1041 2012-03 ENG. BD Medical Medical Surgical Systems The Danby Building Edmund Halley Road Oxford Science Park Oxford OX4 4DQ UK bdmedical@europe.bd.com www.bd.com Carmel Pharma AB Aminogatan 30 SE-431 53 Mölndal SWEDEN