INSTRUCTION MANUAL SAFETY INSTRUCTIONS TABLE OF CONTENTS SAFETY INSTRUCTIONS DEVICE DESCRIPTION AND INTENDED USE SAFETY INSTRUCTIONS

Similar documents
RT-1261A Ear and Forehead Thermometer Owner s Manual

INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101

Forehead. Use and Care Manual. Thermometer IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Model V977

digital fever alert ear thermometer suitable from birth instruction manual

Instant Ear Thermometer

Tympanic Thermometer

Instant Ear Thermometer

Touchless Forehead Thermometer

Hygro-Thermometer + InfraRed Thermometer Model RH101

CareTemp Touch Free Thermometer. Directions for use

Dual Laser InfraRed (IR) Thermometer with Color Alert

Forehead Thermometer INSTRUCTION MANUAL. Model MC-720

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

IN-OUT Thermometer with Cable Free Sensor and Clock

Temperature Humidity Meter

Dual Laser InfraRed (IR) Thermometer

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Dual Laser InfraRed (IR) Thermometer

Wireless Indoor/ Outdoor Thermometer

Microwave Meter. Instruction Manual

Ground Resistance Clamp On Tester

EzFlex Combustible Gas Leak Detector Model EZ40

Dual Laser InfraRed (IR) Thermometer

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

DSM155 Digital LED Light Meter User s Manual DSM155

EXERGEN. English. TemporalScanner TM. Accurate Temperature with a Gentle Forehead Scan. Operators Manual for TAT-5000

NFC Communication Tray Model: HHX-IT3-Z

RS DIGITAL THERMOMETER

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Thermistor Thermometer MODEL NO

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

User's Guide. Pinless Moisture Meter. Model MO257

Instruction Manual Temp 4/5/6 Temperature Meter Series

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

User Guide. 4 wire Earth Resistance Tester Model GRT300

BTH360-S Bluetooth Stereo Headset Specifications & User's Guide

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Owner s Manual

Mini InfraRed Thermometer with Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer

e I N S T RUC TION M ANU A L

Automatic Wrist Blood Pressure Monitor with

How To Use A Thermometer

Application and Instruction Manual Motion Activated Solar Powered LED Security Light with Camera MODEL: XP-2H38WC

REMOTE TERMOMETER TE 219 LED USER MANUAL

Thermocouple Thermometer Models

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Part # rev 1. American Diagnostic Corporation 55 Commerce Drive, Hauppauge, New York

FARMEX HT-PRO OPERATING INSTRUCTIONS PORTABLE MOISTURE AND TEMPERATURE TESTER FOR BALED HAY

4-Channel Thermometer / Datalogger

Mold Alert... Operation Manual P0270

AM/FM PLL Clock/Table Radio

Ground Resistance Clamp-On Tester

by QUICK START GUIDE 1

W850. Maintenance Guide

Wolverine Data PASS Portable Scanner User Manual V1.0

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

ExStik TM ph Waterproof Meters

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Phoenix Body Fat Scale Manual

3D GLASSES FOR SHARP 3D AQUOS OPERATION MANUAL

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Alarm Clock USER GUIDE

Meaco 30L and Meaco 40L dehumidifier instruction manual

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Ultrasonic Distance Meter. Operation Manual

microlife PF 100 Electronic Asthma Monitor Instruction Manual (1-15) Moniteur d'asthme électronique Mode d'emploi (16-31) Monitor electrónico para el

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

BASIC BODY COMPOSITION SCALE

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

INSTRUCTION MANUAL HEM-6052

How To Use A Power Supply Unit (Upu)

AM/FM Portable Radio

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Operating Instructions Air Conditioner

Model UT201/202: OPERATING MANUAL. Table of Contents

USER GUIDE. LED Light Meter. Model LT45

Light Meter (Foot Candles)

Lexmark E260, E260d, and E260dn Series. Maintenance Guide

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

VOICE RECORDER NOTE CORDER DP-211 INSTRUCTIONS. Register your product on and get additional benefits from Olympus!

AD-01 Slave Auto Dialer. Owner s Manual

Portable Multiband Radio ( A) Features Faxback Doc. # 56400

User s Manual MXH-BT600E BLUETOOTH WIRELESS HEADPHONE

Model 349KLX Remote Display Digital Scale User Instructions

ramon 2.2 Radon Monitor manual

Transcription:

TABLE OF CONTENTS INSTRUCTION MANUAL Non-Contact Infrared Thermometer Model : KI-8280 Safety Instructions...1 Device Description and Intended Use...3 About Body Temperature...4 Device and Display Overview...4 Quick Start...5 Explanation of Symbols...6 Battery Installation...7 Setting...8 Changing Modes/Setting...8 Setting C or F Scale...11 Memory Functions...11 Use...12 Measurement Consideration...12 Taking a Measurement...13 Cleaning...14 Care and Storage...14 Product Specification...15 Troubleshooting...16 Warranty...17 WARNING 1. Read the entire instruction manual before trying to operate the device. 2. The device is delivered non-sterile; please clean the device before measuring. 3. Stop using the device if malfunctions appear or if it operates abnormally. 4. Children should not use the device without the supervision of an adult. 5. Do not use the device when flammable materials are around. 6. Do not place the device on scarred tissue, open wounds or abrasions. 7. Some medications may cause a rise in skin temperature which can c o n s e q u e n t l y l e a d t o i n c o r r e c t measurements.. 8. Taking a measurement after skin has been exposed to an extreme condition such as direct exposure to sunlight, fireplace/ heater or air conditioner flow, may lead to incorrect readings. 9. If the device has been kept or stored in extreme temperatures, wait at least one hour for the device to return to room temperature before measuring. CAUTION 1. Do not scrape or scratch the Sensor Lens as it will hamper the effectiveness of the device. 2. Do not dismantle the device except when replacing the batteries. 3. Wait at least thirty minutes after exercising, bathing or eating before taking a measurement. 4. If the subject s body temperature is lower than the room temperature, a false reading may occur. 5. To ensure the best performance of the device, please follow the Product Specification (on pg. 15) Storage Environment regarding temperature and humidity ranges for storing the device. 6. Dispose of the device and batteries according to your local regulatory or environmental protection agency. 7. For maximal performance of the device, we recommend a regular check up and device calibration every two years. DEVICE DESCRIPTION AND INTENDED The non-contact infrared thermometer is an electronic device designed to absorb the infrared from human body to detect your temperature. It is intended to measure the human body temperature for infants and adults without contact to human body. It can be used by consumers in household environment and doctor in clinic as reference. 1 2 3

ABOUT BODY TEMPERATURE DEVICE AND DISPLAY OVERVIEW EXPLANATION OF SYMBOLS BATTERY INSTALLATION A person s normal body temperature c a n r a n g e f r o m 3 5. 5 C t o 3 7. 8 F (95.9 Cto 100.0 F) throughout the day. We recommend taking your temperature at different times during the day when you are NOT sick. This will give you a preliminary reference to know what your normal temperature is and how it fluctuated during a normal day. Then, when you feel sick or discomfort, knowing this will provide an index for a reliable diagnosis of a fever. Display Overview Quick Start Waiting for Setting Measuring Beeper On/Off Offset Adjustment Low Battery Power Off Type BF Applied Part WARNING 1. Use only same type of alkaline batteries to avoid incompatibility. 2. Replace with 2 new AAA batteries at the same time when the low battery indicator appears. 3. The memories will be erased after replacing the batteries. 4. Remove the batteries if the device is not likely to be used for a long period of time. 5. Do not dispose of battery in a fire. The battery may explode. DEVICE AND DISPLAY OVERVIEW Device Overview 1. Install battery into the device. Make sure the polarity (+ and -) of the battery matches as shown in the battery compartment. 2. P r e s s a n d r e l e a s e t h e P O W E R button, you will hear a short beep. The measuring process will begin after the hourglass disappears, you hear two short beeps and either C or F appears. 3. Aim the Probe toward the forehead or object approximately 5cm from surface, then press and release the POWER Button to record the measurement. 4. Read the temperature on the display. MMYY Warning and Caution Lot Number composed by month(m) and year(y) of manufacture Manufacturer Authorized Representative in the European Community 1. Remove the battery cover to insert batteries. 2. Confirm the polarity (+ and -) of batteries is correct as indicated inside the compartment and insert batteries accordingly. 3. Replace the battery cover. 4 5 6 7

Changing Modes/Settings The device has four modes/settings: 1. Forehead mode 2. Object temperature mode 3. Beeper On/Off setting 4. Offset setting The default mode is Forehead mode. 1. Press and release the POWER Button to turn on device. 2. Press and hold the Memory/Mode Button firmly for about 3 seconds. 3. Continue to press and release the Memory/Mode Button to switch between the four modes/settings. Forehead mode This mode is intended to measure the temperature of forehead. the button when the screen show. 2. The device is now ready to measure forehead temperature. Refer to section on page 12 under Measurement Consideration. Carefully read and follow these instructions. Object temperature mode This mode is intended to measure the temperature of object surface. This mode is not intended for determining human body temperature. 1. When switching between four modes/ settings, simply stop pressing the button when the screen shows. 2. The device is now ready to measure the surface of object temperature. Beeper On/Off The default for beeper is ON. You may switch it off to avoid disturbing the patient or others. the button when the screen shows. 2. After the disappears, the device will show on. Press and release the Memory/Mode Button to show OFF. Press the POWER Button to confirm sound is off. 3. To turn the sound back on, repeat step 1 above. 4. After the disappears, the device will show OFF. Press and release the Memory/Mode Button to show on. Press the POWER Button to confirm sound is on. Offset Setting T h e d e v i c e i s c a p a b l e t o c o n v e r t measured forehead temperature reading to oral temperature automatically. You can apply this mode as a reference temperature to other body sites such as rectal, axillary, and auricular. Please use other thermometer to measure your rectal, axillary or auricular temperature to confirm the temperature difference. Offset default is zero (off). Table 1 Body Sites Normal Temperatures Oral 35.5 C ~37.4 C (95.9 F ~99.3 F) Rectal 36.2 C ~37.9 C (97.1 F ~100.2 F) Axillary 35.0 C ~37.0 C (95 F ~98.6 F) Auricular 35.7 C ~37.9 C (96.2 F ~100.2 F) the button when the screen shows. 2. Press the Memory/Mode Button to start offset alignment when symbol disappears. 3. Press the POWER Button to increase offset within range from +1 C to -1 C (+2 F to -2 F). 4. It increases 0.1 C (0.2 F) by pressing the offset manually. 5. Press and release the Memory/Mode Button to turn the offset off. 6. The device will beep twice indication it is ready to begin a new measurement. Setting C or F Scale 1. You may only set/reset the C or F scale when the device in Forehead mode or Object mode. 2. After device is powered on, press and release the Memory/Mode button, then immediately press and release the Power Button to switch the temperature scale. 3. Device is now ready to measure a temperature. 4. Repeat step 2 above to switch back and forth. Memory Functions Recalling Memories 1. Memory recall can only be used when the device is in Forehead mode or Object mode. 2. After device has been powered on, simply press and release the Memory/ Mode Button to show readings stored in memory. 8 9 10 11

PRODUCT SPECIFICATION 3. When finished viewing memory, you may use the device as explained in #3 of Quick Start (pg.5). Deleting Memories Data stored in the memory will disappear after replacing the batteries. Measurement Consideration CAUTION 1. Forehead site must be dry and clean, free of sweat and cosmetics prior to taking measurement. 2. Hair should be held back from forehead site before taking measurement. Aim the probe center at the temple (around 2 cm above eyebrow tail) or object surface. Keep the probe away from skin or object surface around 5cm. Taking a Measurement 1. Press and release the POWER Button to turn on the device. 2. All symbols should appear on the display. 3. Aim the Probe toward the forehead or object, approximately 5cm from surface, then press and release the POWER Button to record the measurement. 4. The measurement is complete when you hear Di Di - Di Di sounds. 5. You can take next measurement instantly. 6. The temperature and back light color shows on the display. 7. The color of the back light is determined by measurement reading. Please refer to Table 2. Table 2 Temperature Reading Back Light C F Color T 37.1 T 98.9 Green 37.2 T 37.4 99 T 99.4 Yellow T 37.5 T 99.5 Red 8. In Forehead Mode Only: The device will continuously beep a fever alarm if the temperature reading is over 37.5 C (99.5 F). 9. The device will automatically power off after 60 seconds of no use. CLEANING 1. Use a cloth dampened with water or neutral detergent to clean and dry the device and Lens. 2. Do not use thinner, benzene, and other harsh cleaners for cleaning the device. 3. Do not immerse the device in water or liquid of any kind. The device is not water proof. CARE AND STORAGE 1. DO NOT drop or crush the device. It is not shock proof. 2. DO NOT dismantle or attempt to modify the device. 3. DO NOT store the device in an extreme environment with direct sunlight, very high or low temperatures or in a place with high moisture/humidity or dust. 4. Please contact your local agent or distributor if the device does not function as described in this manual. Measurement Sites Forehead and Object Measurement 3 ~ 8cm Distance Measurement Time 1 second Display Resolution 0.1 C (0.1 F) Measurement Scale C / F Forehead mode : 32.2 ~ 43.3 C (90 ~ 110 F) Measurement Range Object mode : 0 ~ 100 C (32 ~ 212 F) Forehead mode : 32.2 ~ 43.3 C (90 ~ 110 F) Accuracy ±0.2 C(0.4 F) Object mode : 0 ~ 100 C (32 ~ 212 F) ± 1 C (2 F) Memory 10 sets Auto Shut Off After 60 seconds Operation Environment Storage Environment Power Source Battery Life Dimension Weight Warranty Classification 10 ~ 40 C (50 ~ 104 F) 15 ~ 95%RH (non condensing) -25 ~ +55 C (-13 ~ +131 F) 15 ~ 95%RH (non-condensing) 2 AAA 1.5Volt batteries Approx. 1000 measurement cycles 138 x 90 x 45 mm ( 5.43 x 3.54 x 1.77 in ) 132g (4.66oz) including batteries 1 year Internally powered equipment Type BF Applied Part This device complies with all requirements of ASTM E1965-98 Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature, EN 12470-5 Clinical thermometers - Part 5 : Performance of Infra-red ear thermometers (with maximum device) 12 13 14 15

TROUBLESHOOTING WARRANTY The reading is over 43.3 C (110 F). Please wait a few minutes and measure again. The reading is under 32.2 C (90 F). Please wait a few minutes and measure again. The ambient temperature is out of the Operation Environment range. Please use the device in an ambient temperature of 10 C to 40 C (50 F to 104 F). Warranty: The device comes with a one year warranty if it is operated under normal circumstances without evidence of tampering. See exclusions below. Warranty exclusions: 1. If user does not properly operate the device according to the instructions as described in this manual. 2. If the device shows signs of tampering or attempted modification. 3. Improper handing, such as dropping, liquid or cleaner damage. 4. Natural disasters (such as fire, flood, earthquake, thunder strike). 5. If you do not have a receipt or proof of purchase showing date of purchase. The device self-diagnostic is failed. Please contact the distributor. REV. 20111213 PN. 16 17