Resistance thermometer Model TR30, compact design

Similar documents
Pressure transmitter For general industrial applications Model A-10

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Threaded resistance thermometer Model TR10-C, with protection tube

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Compact pressure switch Flameproof enclosure Ex d Model PCA

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Bimetal thermometer Model 52, industrial series

Hand-held thermometer Model CTH7000

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Precision digital pressure gauge Model CPG1500

Technical Data. Dimensions

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Inductive sensor NI10-M18-Y1X-H1141

Digital display DA 48

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Bypass level indicator With magnetic display Model BNA

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Control- and feedback head for integrated mounting on Robolux valves Type 2036

How To Use A Flowmeter

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

3DLevelScanner II TECHNICAL DATA SHEET

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

RTD Temperature Probe for the Food/Pharmaceutical Industry

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Technical Data Sheet. 3DLevelScanner

Plastic tube flowmeters Series PT/PS

Digital inductive conductivity transmitter

Technical Information RIA14

Technical Data. Dimensions

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

2.12. page Products for Explosion hazardous Environment

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Redundancy Module QUINT-DIODE/40

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Data Sheet PS1B Pressure Switch

Electronic Pressure Switch EDS 300

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Relative pressure transmitter type 520

Digital input modules

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Technical data sheet TDS0070

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Proportional pressure regulators VPPE

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

TEIP11 I/P signal converter for standard signals. Measurement made easy

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Electronic Pressure Switch EDS 3000

Instruction Manual. T3111 T3111L T3111P T3111Ex

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Cable Plug acc. to DIN EN , Form A

Rosemount 333 HART Tri-Loop

Differential Pressure Transmitter Model DPT-10

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Rosemount 333 HART Tri-Loop

SEISMIC VELOCITY TRANSDUCER T1-40

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Series 8146/5-V37 and Series 8150/5-V37

Differential-Hall-Effect based Sensors Series A5S

Plug and Socket Devices SolConeX 16 A Series 8570

Triple Waveband Infra-Red Flame Detection

T0118 T2118 T3118. Instruction Manual

Micro Motion 3098 Gas Specific Gravity Meter

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

J TB/TW Temperature limiter, temperature monitor

Duct Humidity Transmitter

Flow switches Series AD/VH

Terminal Boxes Series 8146

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

DS 600. A contact free flux gate based current measurement sensor 600A rms

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Inductive slot sensor

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Features. Picture. Specifications

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

TX OPEN RS232/485 module

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Flameproof Audible Signal 115 db (A) Series YA90

Cross-beam scanning system to detect slim objects. 100 mm in

Transcription:

Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 for further approvals see page 8 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics General applications Special features Measuring ranges from -50... +250 C (-58... +482 F), accuracy class per DIN EN 60751 TR30-W: integrated transmitter, programmable and able to be calibrated via software Electrical connection via DIN angular connector or circular connector Process connection and sensor tube from stainless steel Explosion-protected versions Ex i Fig. left: with circular connector M12 x 1 Fig. right: with DIN angular connector Description Resistance thermometers of this series are used as universal thermometers for the measurement of liquid and gaseous media. They can be used for pressures up to 40 bar (special designs to 400 bar dependent on insertion length and diameter). All electrical components are protected against splashed water and are designed to withstand vibration. The TR30 resistance thermometer consists of a sensor tube, which can be fixed into the process using a permanentlywelded threaded connection or a compression fitting. A version with no process connection is also available. The electrical connection is made via a DIN angular connector or an M12 x 1 circular connector. Output signal Pt100 The model TR30-P resistance thermometer is available with a direct Pt100 signal. An intrinsically safe variant can be supplied as an option. Output signal 4... 20 ma In the model TR30-W resistance thermometer, a softwareprogrammable transmitter with a 4... 20 ma output signal is built in. Thus the measured temperature values can be transmitted safely and simply. The model TR30-W resistance thermometer is available, as an option, in an intrinsically safe variant. WIKA data sheet TE 60.30 06/2016 Page 1 of 8 Data sheets showing similar products and accessories: Resistance thermometer, miniature design model TR31; see data sheet TE 60.31 Programming unit model PU-448; see data sheet AC 80.16

Specifications Thermometer with direct sensor output with Pt100 output signal, model TR30-P Temperature range Class A Class B Measuring element (measuring current: 0.1... 1.0 ma) Connection method Measuring element tolerance value per IEC 60751 Electrical connection Explosion protection (option) For detailed specifications for Pt sensors, see Technical information IN 00.17 at www.wika.com. Without neck tube -30... +150 C (-22... +302 F) With neck tube -30... +250 C (-22... +482 F) Without neck tube -50... +150 C (-58... +302 F) With neck tube -50... +250 C (-58... +482 F) Pt100 measuring resistor 2-wire 3-wire 4-wire Class B Class A M12 x 1 circular connector (4-pin) DIN angular connector form A for cables with Ø 6... 8 mm, cross section max. 1.5 mm² Intrinsically safe to Ex i gas/dust Thermometer with transmitter and 4... 20 ma output signal, model TR30-W Temperature range 1) Class A Class B Without neck tube -30... +150 C (-22... +302 F) With neck tube -30... +250 C (-22... +482 F) Without neck tube -50... +150 C (-58... +302 F) With neck tube -50... +250 C (-58... +482 F) Pt100 measuring resistor Class B Class A Minimum 20 K, maximum 300 K Measuring range 0... 150 C, other measuring ranges are adjustable 4... 20 ma, 2-wire Measuring element (measuring current: 0.5 ma) Tolerance value of the measuring element 1) per IEC 60751 Measuring span Basic configuration Analogue output Measuring deviation per IEC 60770, 23 C ±5 K 1 % (Transmitter) 2) Linearisation Linear to temperature per IEC 60751 Linearisation error ±0.1 % 3) Switch-on delay, electrical < 10 ms Current signal for fault signal Sensor short-circuit Load R A Effect of load Power supply U B Max. permissible residual ripple Power supply input Power supply effect Electromagnetic compatibility (EMC) Temperature units Info data Configuration and calibration data Electrical connection Explosion protection (option) Configurable in accordance with NAMUR NE43 downscale 3.6 ma upscale 21.0 ma Not configurable, generally NAMUR downscale 3.6 ma R A (U B - 9 V) / 0.023 A with R A in Ω and U B in V ±0.05 % / 100 Ω DC 10... 35 V 10 % at 24 V / maximum 300 Ω load Protected against reverse polarity ±0.025 % / V EN 61326 emission (group 1, class B) and interference immunity (industrial application) 4), and also per NAMUR NE21 Configurable C, F, K TAG No., descriptor and message can be stored in transmitter Permanently stored in EEPROM M12 x 1, 4-pin circular connector DIN angular connector form A for cables with Ø 6... 8 mm, cross section max. 1.5 mm² Intrinsically safe to Ex i gas/dust Safety-related maximum values for the current loop (+ and - connections): U i = DC 30 V C i = 6.2 nf I i = 120 ma L i = 110 µh P i = 800 mw Readings in % refer to the measuring span For a correct determination of the overall measuring error, both sensor and transmitter measuring deviations have to be considered. 1) The temperature transmitter should therefore be protected from temperatures over 85 C (185 F) 2) For measuring spans smaller than 50 K additional 0.1 K 3) ±0.2 % for measuring ranges with a lower limit less than 0 C (32 F) 4) Use resistance thermometers with shielded cable, and ground the shield on at least one end of the lead, if the lines are longer than 30 m or leave the building. Page 2 of 8 WIKA data sheet TE 60.30 06/2016

Ambient conditions Ambient and storage temperature -40 +85 C (-40... +185 F) Model TR30-P with DIN angular connector: -40... +125 C (-40... +257 F) Ingress protection IP67 per IEC 529 / EN 60529 for circular connector M12 x 1 IP65 per IEC 529 / EN 60529 for DIN angular connector form A The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection. Accuracy 5) -1 Kelvin Response time t 50 < 5 s t 90 < 10 s (for sensor diameter 6 mm) Materials (case and process connection) Stainless steel Vibration resistance 3 g (IEC 60751, standard) 20 g (IEC 60751, special designs, up to a max. insertion length of 160 mm, no compression fittings) Sensor tube Materials Process connection (welded / compression fitting) Thread per DIN 3852, form A Sensor insertion lengths Sensor diameter Stainless steel 1.4571 (316Ti) G ¼ B (not for sensor diameter 8 mm) G ⅜ B G ½ B ¼ NPT (not for sensor diameter 8 mm) ½ NPT without 25, 50, 75, 100, 120, 150, 200, 300, 400 or 500 mm (other insertion lengths possible; ask for delivery times) 3 mm (only for insertion length 25 mm) 6) 6 mm (insertion lengths 50... 500 mm) 6 mm, tapered to 3 mm (insertion lengths 50... 500 mm) 8 mm (insertion lengths 50... 500 mm) 5) Measured at 100 C (212 F) 6) The use of a compression fitting is excluded. Note: The resistance thermometers of the series TR30 are designed for direct installation into the process. Using it in an additional thermowell makes no sense. WIKA data sheet TE 60.30 06/2016 Page 3 of 8

Dimensions in mm Process connection with parallel threads (or without process connection) Angular connector DIN EN 175301-803 Circular connector M12 x 1 (4-pin) compression fitting neck tube 11176688.06 out process connection tapered tip Process connection with tapered threads Angular connector DIN EN 175301-803 Circular connector M12 x 1 (4-pin) compression fitting neck tube 11318708.02 tapered tip Legend: U 1 Insertion length (parallel thread) U 2 Insertion length (tapered thread) N Ød Neck tube length (70 mm) Sensor diameter Page 4 of 8 WIKA data sheet TE 60.30 06/2016

Explosion protection (option) Configuration software WIKAsoft-TT Resistance thermometers of the TR30 series are available with certificates (NEPSI and EACEx) for the ignition protection type intrinsic safety Ex i. These instruments comply with the requirements for gas and dust. The classification/suitability of the instrument for the respective category can be seen on the corresponding certificates. Configuration software (multilingual) as a download from www.wika.com Accessories Model Special features Order no. Programming unit Easy to use 11606304 model PU-448 LED status/diagnostic displays Compact design No further voltage supply is needed for either the programming unit or for the transmitter Adapter cable M12 to PU-448 Adapter cable for the connection of model TR30-W resistance thermometer to the model PU-448 programming unit 14003193 Adapter cable DIN angular connector to PU-448 Adapter cable of the DIN angular connector for the connection of a model TR30-W resistance thermometer with a DIN EN 175301-803 form A angular connector to the model PU-448 programming unit 14005324 WIKA data sheet TE 60.30 06/2016 Page 5 of 8

Connecting PU-448 programming unit Connection PU-448 adapter cable with M12 connector 14004919.01 TR30-W Connection PU-448 adapter cable with DIN angular connector, form A 14005537.01 TR30-W Page 6 of 8 WIKA data sheet TE 60.30 06/2016

Electrical connection Output signal Pt100, model TR30-P Angular connector DIN EN 175301-803 Circular connector M12 x 1 (4-pin) EA_TR30-P EA_TR30-P Output signal 4... 20 ma, model TR30-W Angular connector DIN EN 175301-803 Load diagram for model TR30-W The permissible load depends on the loop supply voltage. Circular connector M12 x 1 (4-pin) EA_TR30-W EA_TR30-W Load RA in Ω 1182 909 636 0 10 24 30 36 Power supply U B in V 2363156.02 WIKA data sheet TE 60.30 06/2016 Page 7 of 8

Approvals Logo Description Country EU declaration of conformity EMC directive 1) EN 61326 emission (group 1, class B) and interference immunity (industrial application) European Community EAC (option) Electromagnetic compatibility 1) Hazardous areas 0 Ex ia IIC T6... T1 or DIPA21 TA 60 C/TA 90 C/TA 120 C GOST (option) Metrology, measurement technology KazInMetr (option) Metrology, measurement technology - MTSCHS (option) Permission for commissioning Uzstandard (option) Metrology, measurement technology NEPSI (option) Hazardous areas II 1G Ex ia IIC T* or II 2D Ex iad 21 T* DNV (option) Ships, shipbuilding (e.g. offshore) Hazardous areas Location classes: Model Temperature Humidity Vibration EMC Enclosure TR30-P D B B - C TR30-W D B B A/B 2) C Eurasian Economic Community Russia Kazakhstan Kazakhstan Uzbekistan China International 1) Only for built-in transmitter 2) EMC class B when supplied from a dedicated DC 24 V power supply EMC class A when supplied directly form the ship s distribution board Certificates (option) 2.2 test report 3.1 inspection certificate DKD/DAkkS calibration certificate Approvals and certificates, see website Ordering information Model / Output signal / Explosion protection / Mechanical tests / Electrical connection / Neck tube / Process connection / Measuring element / Connection method / Temperature range / Transmitter initial value / Transmitter end value / Sensor diameter / Sensor insertion length / Certificates / Options 2008 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 8 of 8 WIKA data sheet TE 60.30 06/2016 06/2016 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de