A range of popular roof shades Maxicover Roof Coat cannot be tinted.

Similar documents
Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

TECHNICAL DATA SHEET HAMMERITE METAL PAINT. Smooth Hammered Satin Aerosol

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION

White rust on galvanized and galvanized pre-painted steel. Technical Information

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Tractor Painting Tips

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

Technical Data SeaQueen

SC2000 CEMENT BONDING PROCEDURES

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

Note: Minor color change may occur in exposed service, but corrosion protection will not be compromised

BLACK JACK ALL WEATHER ROOF COATING

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

PRODUCT DATA SHEET Sika Cable System

Wecryl Waterproofing System under surfacing supplied by others

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

Product Information/Specifications

SURFACE PREPARATION STANDARDS

( II ) INDUSTRIAL & PROTECTIVE SYSTEM

The Application Guide offers product details and recommended practices for the use of the product.

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

RAPTOR TRUCK BED LINER - BLACK

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

10P20-44 High Solids Epoxy Primer

Additional Information. Paint Application

Product Information. D8115 Matte and D8117 Semi-Gloss Clearcoat System

3M Scotchkote Urethane Coating 165HB

UNILIC ACRYLIC EMULSION

Mineral waterproof coating PCI Dichtschlämme

K2 STONE NATURAL VENEER

Solvent Cementing Instructions For Plastic Pipe & Fittings

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

How To Test A Base Axe

T R A N S F E R A B L E F U L LY

Chromadek for Roofing Applications Pre-painted hot-dip galvanised steel sheet

Elastic, 1-part-polyurethane, liquid waterproofing membrane

Black epoxy paste adhesive system

Pictorial Surface Preparation Standards For Painting Steel Surfaces

WATERPROOFING OF WET ROOMS

Technical Data Sheet February 2014

ApplicatorTrainingBulletin. The Galvanized Surface. Surface Preparation of New Galvanizing

STERI-SOFT HIGH FOOT TRAFFIC, ULTRAVIOLET RESISTANT, URETHANE RESILIENT FLOORING SYSTEM, 1/8 GREEN BUILDING FEATURES TYPICAL APPLICATIONS

SURFACE PREPARATION. High pressure fresh water cleaning.

GigaCrete Specification PlasterMax

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

GRIP-GARD BC BASECOAT CHROME

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Material Product Data Sheet Sealers for Thermal Spray Coatings

PRODUCT DATA SHEET DESCRIPTION:

KEEP ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET THIS GUIDE

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

Product Information/Specifications

DENSO WATERPROOFING SYSTEMS

Low viscosity, solvent free elastic adhesive for wood flooring

3.8 HSP (High Solids Polyurethane)

Eclipse. Technical Data Sheet. Polyurethane topcoat. Product Group

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

Temperature C Cure time to reach hours LSS > 1MPa minutes

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

General Surface Preparation

Popular Paint Systems

Epoxy Floor Coating Problem Solving Guide

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Colours to stand the test of time. paint range

3 Scotch-Weld TM. Structural Adhesive Films AF 6 AF 10 AF 13. Technical Data July, 2001

Division 9. SignaFlor Pad and Pour Flooring System

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data January, 2010

You have just purchased the most portable and economical spray chrome system in the world!

How to repair your existing low slope flat roof.

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

WOLVERHAMPTON WASTE SERVICES GUIDANCE FOR THE SAFE REMOVAL, COLLECTION AND DISPOSAL OF MATERIALS CONTAINING ASBESTOS OR ASBESTOS CEMENT

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

G4 is browny translucent in colour and is effected by UV light. Therefore it is for internal use unless top coated to protect it from UV light

SEE HOW TO MAKE LIME PLASTER WHY USE LIME? PATTI STOUTER, BUILD SIMPLE INC. FEBRUARY 2013

Protecting Galvanized Steel Sheet Products from Storage Stain Rev 2.1 Aug-03

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

Two component epoxy paste adhesive

Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products

PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL

SOLVENT CLEANER MSDS Page 1 of 5 SAFETY DATA SHEET. (To comply with OSHA s Hazard Communication Standard 29CFR /ANSI z400.

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

INDEPENDENTS AIL RET 2012

COMPOSITION / INFORMATION ON INGREDIENTS

Minor Cracks in Horizontal Surfaces

Resurfacing Concrete. Page 1 of 5

Asbestos. from the Home. Removing. Read this booklet for:

SAFETY DATA SHEET EVO-STIK GRIPFILL SOLVENT FREE (Irl)

Two component epoxy paste adhesive. Ideal for bonding GRP, SMC and dissimilar substrates

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Transcription:

TECHNICAL DATA SHEET Version 1 2016 MAY THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION A quality, 100% pure acrylic paint for roofs PRODUCT USES Maxicover Roof Coat is for application to suitably primed galvanised iron, fibre cement and cement roof tiles. Although a roof paint, it can also be applied to other areas such as side cladding, galvanised iron garage doors, gutters, downpipes and cement garden pots. FEATURES AND BENEFITS Pure Acrylic weather protection. Good adhesion to roofs. Durability against roof temperature fluctuations. UV and Weather resistant. Easy water clean-up. PRODUCT INFORMATION Appearance Colour Binder Type Low Sheen A range of popular roof shades Maxicover Roof Coat cannot be tinted. Pure Acrylic Density at 23 C Approx. 1.28 Solids Content By weight: Approx. 45%. By volume: Approx. 31% Packaged Viscosity Viscosity at 23 C: Approx. 110 KU Spreading Rate Approx. 7-8m² per liter on non-porous surfaces, depending on surface profile and application method. Approx. 4-5m² per liter on porous surfaces, depending on surface profile and application method. Recommended DFT per coat Min. 40µm. Max. 45µm. Recommended WFT per coat Min. 130µm. Max. 145µm. Flash Point Non-flammable

APPLICATION INFORMATION Mixing Stir until homogeneous with a flat paddle. Application Surface Conditions Surface Temperature between 10 C - 35 C. Relative Humidity between 10 % 85 % OR 2 C above dew point minimum Application Methods Brush or roller or spray application For airless spray application, the suggested Airless Spray Tip is 0.017-21 at 150 200 Bar. Thinner Thinning not recommended, however a thinned coat to a maximum of 10% with water will act as a primer coat and will need to be followed up with 2 undiluted coats of Maxicover Roof Coat. Drying Time Touch dry 1 hour. Recoating Time 4 hours (Drying times will be extended during cold, wet or humid conditions.) Cleaning of Equipment Substrates Precautions: After use, remove as much product as possible, and then clean immediately with water. Cement roof tiles galvanised iron and fibre cement. Other applications include side cladding, galvanised iron garage doors, gutters and downpipes. Do not apply directly to galvanised iron surfaces. Not suitable for direct application to powdery or friable surfaces whether previously painted or not. Maxicover Roof Coat is not recommended for application to Chromadek roof sheeting or Galvanised Iron roof sheeting with insulation board OR Clay, Slurry coated tiles and slate. Under no circumstances should a Water Based Etch Primer be used as a primer for this product on galvanised iron roofs. Coats Required Apply two to three finishing coats to new and previously coated surfaces to achieve a closed film and solid colour. The quantity of paint required can be obtained by measuring the floor area of the house covered by the roof, including overhang. Additional allowance of + 30% must be made for the pitch of the roof, plus approx. 30% for the corrugated profile. Divide the total area by the spreading rate of the paint (see Product Information) to give an indication of the paint requirements per coat. Make allowance for thinning of the primer coat. Page 2 of 6

SURFACE PREPARATION Ensure that surfaces are sound and free from dust, oil, grease, dirt, and debris. Surfaces must be thoroughly dry - no more than 12% moisture content. NEW SURFACES Galvanised Iron (new, un-weathered) Heavy fabricator s pre-treatment oil, and other surface contaminates must be removed with Dulux Galvanised Iron Cleaner. A water-break free surface indicates thorough cleaning - running water should not form droplets. Prime with one full coat of Dulux Galvanised Iron Primer. Galvanised Iron (unpainted, weathered) Remove all loose rust and white scale by means of wire brushing, sanding, chipping, or mechanical scouring - down to bright metal. To remove dirt, salts and zinc corrosion (white rust) clean thoroughly with Dulux Galvanised Iron Cleaner achieving a waterbreak free surface. Areas showing red rust must be removed back to bright galvanised iron spot primed with Dulux Galvanised Iron Primer followed by one full coat of the same primer. Galvanised Iron in aggressive/coastal conditions Remove all loose rust and scale by means of wire brushing, sanding, chipping, or mechanical scouring - down to bright metal. To remove dirt, salts and zinc corrosion (white rust) clean thoroughly with Dulux Galvanised Iron Cleaner. Apply two full coats of Dulux Galvanised Iron Primer. Cement and Fibre Cement Roof Tiles (new) To remove dust, debris and chalky residue, wash the entire roof area using highpressure washing, using a rotating nozzle at a pressure between 150 and 200 bar. Alternatively, scrub the entire roof area with a bristle brush, using water from a garden hose and allow drying. For sound cement roof tiles; prime with one coat Maxicover Roof Coat, thinned up to 10% with water to aid absorption followed by 2 undiluted coats of Maxicover Roof Coat. Page 3 of 6

SURFACE PREPARATION NEW SURFACES Cement and Fibre Cement Roof Tiles (new) For very porous/slightly friable/chalky cement tiles and all fibre cement tiles; prime with Dulux Bonding Liquid and overcoat within 48 hours with 2 coats Maxicover Roof Coat. Cement and Fibre Cement Roof Tiles (weathered, unpainted) To remove dust, debris and chalky residue from cement roof tiles, wash the entire roof area using high-pressure washing, using a rotating nozzle at a pressure between 150 and 200 bar. Alternatively, scrub the entire roof area with a bristle brush, using water from a garden hose. Old, weathered fibre cement is porous and may encourage the growth of fungus. Scrub these areas with either of the following solutions: 25% chlorine solution and water or 25% sodium hypochlorite and water solution. Rinse off thoroughly, removing residues of the cleaning solution, and at the same time cleaning off dust and debris from the roof. For sound cement roof tiles; prime with one coat Maxicover Roof Coat, thinned up to 10% with water to aid absorption followed by 2 undiluted coats of Maxicover Roof Coat. For very porous/slightly friable/chalky cement tiles and all fibre cement tiles; prime with Dulux Bonding Liquid and overcoat within 48 hours with 2 coats Maxicover Roof Coat. Waterproofing. Were required apply at least three coats Dulux Rainshield over the primer coat, recommended minimum waterproofing dry film thickness of 1000μm. Overcoat with 2 coats Maxicover Roof Coat. PREVIOUSLY PAINTED SURFACES Galvanised Iron Perform adhesion tests on the existing coating to cross cut test ISO 2409-2013 standards. Remove lose roof paint back to a sound surface and/or bare galvanised iron. For Galvanised Iron in poor condition, strip completely. Remove all loose rust and scale by means of wire brushing, sanding, chipping, or mechanical scouring - down to bright metal. To remove dirt, salts and zinc corrosion (white rust) clean thoroughly with Dulux Galvanised Iron Cleaner achieving a waterbreak free surface. For sound surfaces scrub the area with Dulux Sugar Soap/water solution. Clean with high pressure water jet to remove Dulux Sugar Soap residue and other surface contaminates. Apply two full coats of Dulux Galvanised Iron Primer to all exposed galvanised iron. Page 4 of 6

SURFACE PREPARATION PREVIOUSLY PAINTED SURFACES Cement and Fibre Cement Roof Tiles Perform adhesion tests on the existing coating to cross cut test ISO 2409-2013 standards. To remove dust, debris and chalky residue and lose paint from cement roof tiles, wash the entire roof area using high-pressure washing, using a rotating nozzle at a pressure between 150 and 200 bar. Alternatively, scrub the entire roof area with a bristle brush, using water from a garden hose. Cement and Fibre Cement Roof Tiles in poor condition, strip completely. Old, weathered fibre cement is porous and may encourage the growth of fungus. Scrub these areas with either of the following solutions: 25% chlorine solution and water or 25% sodium hypochlorite and water solution. Rinse off thoroughly, removing residues of the cleaning solution, and at the same time cleaning off dust and debris from the roof. For sound cement roof tiles; prime with one coat Maxicover Roof Coat, thinned up to 10% with water to aid absorption followed by 2 undiluted coats of Maxicover Roof Coat. For very porous/slightly friable/chalky cement tiles and all fibre cement tiles; prime with Dulux Bonding Liquid and overcoat within 48 hours with 2 coats Maxicover Roof Coat. Waterproofing. Were required apply at least three coats Dulux Rainshield over the primer coat, recommended minimum waterproofing dry film thickness of 1000μm. Overcoat with 2 coats Maxicover Roof Coat. GUARANTEE Dulux offers a 7-year product guarantee on Maxicover Roof Coat (white and standard colours). Maxicover Roof Coat when tinted is not guaranteed, as Dulux does not offer tint bases in the Maxicover Roof Coat range. To register your guarantee, simply call the Dulux Technical Helpline within 30 days of purchase. Simply supply your contact details, the site details, purchase details, batch number and related products used. You will receive a Guarantee Reference Number that you should record and keep in a safe place, together with your purchase slip for future reference. For terms and conditions of the guarantee, please visit www.duluxguarantee.co.za or contact Dulux Technical Helpline 0860 330 111. Page 5 of 6

HEALTH AND SAFETY INFORMATION This product contains no added lead. Avoid contact with skin or eyes. Keep out of reach of children. If accidently swallowed, seek medical advice immediately and show this container to the doctor. Dry sanding, flame cutting and/or welding of the dry paint film will give rise to dust and/or hazardous fumes. If exposure cannot be avoided by the provision of local exhaust ventilation, suitable respiratory protective equipment should be used. Do not empty into drains or watercourses. Ensure good ventilation during application and drying. It is recommended to use suitable protective clothing and equipment. To avoid the risk of spillage, always store and transport containers in a secure upright position. Refer to Material Safety Data Sheet for complete information. ADDITIONAL INFORMATION Packaging Storage Conditions Disclaimers 20Lt Store under cool dry conditions away from direct sunlight, heat and extreme cold. Colour references are as accurate as modern printing will allow. For best colour and sheen consistency, it is advisable to use containers of the same batch number, or to mix different batches together in a large container, or to finish in a corner before starting a new container. TDS STANDARD DISCLAIMER The recommendations contained herein are given in good faith and meant to guide the specifier or user in accordance with good painting practices. They are gained from our tests and experiences and are believed to be accurate and reliable. No warranty/guarantee is implied by the recommendations contained herein since the conditions of use; application method, substrate and cleanliness of the substrate are beyond Dulux control. Important Note; Technology may change with time, necessitating changes to this Technical Data Sheet (TDS). It is the responsibility of the user to ensure that the latest TDS is being used for reference. Dulux Technical Data Sheets are available on our website www.dulux.co.za or please contact: Dulux On-Line on 0860 330 111. Email ZA.Helpline@akzonobel.com ICI Dulux (Pty) Ltd is part of AkzoNobel. ICI Dulux (Pty) Ltd Reg No.1946/020769/07 Page 6 of 6