Square D Clipsal DIN Rail Mounted Power Supply, 350mA. SLC5500HPS 277V and SLC5500TPS V For Use with Wired C-Bus Networks

Similar documents
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

Square D Clipsal C-Bus Network Analyzer

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

IFS SP-PoE Splitter User Manual

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

=============================== WARNING

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Broadband Telecommunications Drop Amplifier

MCR1900 Media Converter 19-Slot Chassis

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

USB/VGA Cat 5 UTP Console Extender

DVI to Mini DisplayPort Converter. EXT-DVI-2-MDP User Manual

Power supply unit Model: PAC-SC50KUA

HDMI / DVI Video Test Pattern Signal Generator

Installer Guide smart connect

12-Volt 10-Amp Regulated Power Supply

Pad. Quick Start Guide

Model 70A00-1. GSM Cellular Communications Center

MoCA Adapter MC1001 v2 Installation Guide

StructureScan HD Module. Installation Guide ENGLISH

2013 VTech Printed in China US

Composite/S-Video to HDMI Video Converter with Audio

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

FCC COMPLIANCE STATEMENT

NFC Communication Tray Model: HHX-IT3-Z

PrintPAD CN3/4/3e/4e. User Guide

4-Port Pocket. USB KVM Switch with USB 2.0 Hub

Wireless Indoor/ Outdoor Thermometer

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

AXIS T81B22 DC 30W Midspan

Bluetooth Stereo Headphone. User Guide. Hive

Manual. Simrad StructureScan LSS-1 Sonar Module. English

AXIS 291 1U Video Server Rack Installation Guide

Power Over Ethernet Adapters POE101

2 Port KVM Switch. If anything is damaged or missing, contact your dealer.

READ FIRST! Universal Car/Air Adapter User Manual

Composite/S-Video to VGA Video Converter

The Third Rail System User Manual

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

10/100 Power over Ethernet Kit 48V Injector and 5V/ 12V Splitter

HDMI over Cat5 Video Extender with RS232 and IR Control

WD-AMX Water Detection Controllers

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s ( A, A) Manual

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

HDMI Switch USER MANUAL VS481A

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Modular I/O System Analog and Digital Interface Modules

Model PS-4001 Power Supply User Instructions

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

CONSOLE REMOTE I /O AC 9V

SATA and SAS Hard Drive Backplane

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

For the US-market only! CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Instruction Guide. 4 Port Laptop-Sized USB 2.0 Mini Hub ST4200MINI. The Professionals Source For Hard-to-Find Computer Parts

4 Port VGA Video Audio Switch with RS232 control

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Instruction Guide. Professional VGA to NTSC/PAL TV Converter with Remote VGA2NTSCPRO. The Professionals Source For Hard-to-Find Computer Parts

ADM1TE 5/30A DIN rail single phase two wire energy meter

8-Port PoE Network Switch

C-Bus Network Monitor

DVI USB KVM Console Extender with USB 2.0 and Audio - 500m

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

ALPHA Meter Installation Information

BroadBand PowerShield. User Manual

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS

DLP-PU/E Instruction Manual

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

LIEBERT VNSA Installation Sheet

Serial ATA Hard Drive Docking Station

VGA USB KVM Console Extender over CAT5 UTP (500 ft)

Mini Power Bank and Charger

3.5 mm Audio Jack. Manual innoxplore ix B24 A2DP Stereo Bluetooth Audio Adapter Dongle 3.5mm Audio Jack [ix B24] Contents

Provides one channel for Ethernet over existing

About the HotWire Slot Standalone Shelf

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

Manual Ranging MultiMeter

Zolt Laptop Charger Plus User Guide

IMPORTANT SAFETY INSTRUCTIONS

Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide

INSTALLATION INSTRUCTIONS

VDSL Ethernet LAN Extender

DVI DA2 and DVI DA 4 User Guide

AutoRanging Digital MultiMeter

Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Transcription:

Square D Clipsal DIN Rail Mounted Power Supply, 350mA SLC5500HPS 277V and SLC5500TPS 110-120V For Use with Wired C-Bus Networks

Square D Clipsal DIN Rail Mounted Power Supply, 350mA 63249-420-204A2 Instruction Bulletin 04/2007 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this bulletin or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of either symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Danger indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, can result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. Caution, used without the safety alert symbol, indicates a potentially hazardous situation which, if not avoided, can result in property damage or improper operation. NOTE: Provides additional information to clarify or simplify a procedure. 2 2007 Schneider Electric. All Rights Reserved.

63249-420-204A2 Square D Clipsal DIN Rail Mounted Power Supply, 350mA 04/2007 Instruction Bulletin PLEASE NOTE Class B FCC Statement Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. This document is not intended as an instruction manual for untrained persons. No responsibility is assumed by Square D for any consequences arising out of the use of this manual. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. 2007 Schneider Electric. All Rights Reserved. 3

Square D Clipsal DIN Rail Mounted Power Supply, 350mA 63249-420-204A2 Instruction Bulletin 04/2007 INTRODUCTION The 5500PS series Power Supply provides operating power for units on the C-Bus network. It is DIN rail mounted for easy installation. The C-Bus network connection is conveniently achieved through the use of RJ45 connectors, allowing C-Bus units to be quickly added to the network. The 5500PS series Power Supply is available in these configurations: SLC5500HPS 350mA (277V*, 50/60Hz) SLC5500TPS 350mA (110-120V*, 50/60Hz) * Nominal Supply Voltage ± 10%. Before You Begin Before installing the Power Supply, inspect it carefully. Verify the catalog number on the box label. Table 1: Contents of the Box Part Number Description Quantity SLC5500HPS or SLC5500TPS 350mA (277V, 50/60Hz) 1 350mA (110-120V, 50/60Hz) Rubber RJ45 terminal plugs 3 RJ5CB300PL C-bus network cable, 15.7 in. (400 mm) 1 4 2007 Schneider Electric. All Rights Reserved.

63249-420-204A2 Square D Clipsal DIN Rail Mounted Power Supply, 350mA 04/2007 Instruction Bulletin SAFETY PRECAUTIONS This section contains important safety precautions that must be followed before attempting to install or maintain electrical equipment. Carefully read and follow the safety precautions below. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH This equipment must be installed and serviced by qualified electrical personnel. Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E. Turn off all electrical power supplying this equipment before working on or inside the equipment. Always use a properly rated voltage sensing device to confirm that power is off. Replace all devices, doors, and covers before turning on power to this equipment. Failure to follow these instructions will result in death or serious injury. 2007 Schneider Electric. All Rights Reserved. 5

Square D Clipsal DIN Rail Mounted Power Supply, 350mA 63249-420-204A2 Instruction Bulletin 04/2007 INSTALLATION Network Considerations Follow the steps in the sections below to properly install the Power Supply. Plan your C-Bus network installation carefully. It is recommended that power supplies be distributed evenly along the C-Bus network. Each Power Supply provides 350mA of isolated 36Vdc class 2 voltage to the C-Bus network. Each Power Supply can support up to 15 C-Bus devices at approximately 22mA per unit (PC Interface draws 32mA). The installer should verify that an adequate number of C-Bus network Power Supplies are installed to support the connected devices. The total number of units connected to the C-Bus network must not exceed 350mA. Consult the C-Bus Calculator Network Design Verification Software Utility to determine the total network current load. A maximum of five (5) 5500PS series Power Supply units may be connected on a single C-Bus network. Other units incorporating a C-Bus Power Supply may be used in conjunction with this Power Supply provided that the total available current supplied to the network does not exceed 2000mA (2A). HAZARD OF IMPROPER OPERATION OR SYSTEM DAMAGE. Use only C-Bus Power Supplies with units connected to a C-Bus network. Failure to follow this instruction can result in improper operation or system damage. 6 2007 Schneider Electric. All Rights Reserved.

63249-420-204A2 Square D Clipsal DIN Rail Mounted Power Supply, 350mA 04/2007 Instruction Bulletin Mounting the Power Supply onto the DIN Rail The DIN-rail units are designed to be installed onto a standard 1.38 in. (35 mm) DIN rail. To mount (i.e., attach) the DIN unit, hook it onto the top of the DIN rail. Swing the bottom of the unit down until it clicks into place. Figure 1: Mounting the Unit onto the DIN Rail KEY: A. DIN rail B. DIN-rail unit 1. Hook the unit onto the top of the DIN rail 2. Swing the bottom of the unit down 3. Mounted unit Removing the Power Supply from the DIN Rail Use a small flat-blade screwdriver to pull either the upper or lower slide release out and disengage the unit from the DIN rail. Figure 2: Removing the Unit from the DIN Rail KEY: A. DIN rail B. Unit 1. Pull out the slide release 2. Pull the unit away from the DIN rail 3. Lift the unit away from the rail 2007 Schneider Electric. All Rights Reserved. 7

Square D Clipsal DIN Rail Mounted Power Supply, 350mA 63249-420-204A2 Instruction Bulletin 04/2007 CONNECTIONS Follow the procedures in this section to properly make C-Bus network cable and electrical wiring connections. Connecting the Power Supply to the C-Bus Network Installation requires connection to the unshielded twisted pair C-Bus Network Cable. Use a Category 5 data cable. NOTE: Install rubber plugs provided in any unused RJ45 cable terminals. Figure 3: C-Bus Network Cable Terminals KEY: A. Power supply (front view) B. RJ45 cable terminals (bottom view) 8 2007 Schneider Electric. All Rights Reserved.

63249-420-204A2 Square D Clipsal DIN Rail Mounted Power Supply, 350mA 04/2007 Instruction Bulletin Table 2: RJ45 Pin Connections RJ Pin C-Bus Connection Color 1 Remote ON* Green/White 2 Remote ON* Green 3 C-Bus Neg (-) Orange/White 4 C-Bus Pos (+) Blue 5 C-Bus Neg (-) Blue/White 6 C-Bus Pos (+) Orange 7 Remote OFF* Brown/White 8 Remote OFF* Brown *Not used in 5500PS series units 2007 Schneider Electric. All Rights Reserved. 9

Square D Clipsal DIN Rail Mounted Power Supply, 350mA 63249-420-204A2 Instruction Bulletin 04/2007 Making Electrical Wiring Connections HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH This equipment must be installed and serviced by qualified electrical personnel. Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E. Turn off all electrical power supplying this equipment before working on or inside the equipment. Always use a properly rated voltage sensing device to confirm that power is off. Replace all devices, doors, and covers before turning on power to this equipment. Failure to follow these instructions will result in death or serious injury. 10 2007 Schneider Electric. All Rights Reserved.

63249-420-204A2 Square D Clipsal DIN Rail Mounted Power Supply, 350mA 04/2007 Instruction Bulletin Verify that the power supplying the system is turned OFF before handling electrical power conductors. Follow the guidelines listed in this section for making electrical connections. Make electrical wiring connections to the line terminals as shown in the illustration below. Use #12-16 AWG (3.1mm² - 1.3mm²) copper wire only. Take care that wire cuttings or debris do not enter the unit. Do not exceed 1.0 ft-lb. (1.4 nm) maximum torque on power terminals. Electrical power conductors must be separated from the C-Bus network cable and all other class 2 conductors. Wiring must be routed to maintain minimum separation or be separated by barriers. Consult your electrical code for local requirements. Megger testing of electrical power terminals will not damage this unit. Since this unit contains electronic components, the installer should interpret Megger readings with due regards to the nature of the circuit connection. Figure 4: Electrical Wiring Terminals KEY: A. Electrical wiring terminals NOTE: Use #12-16 AWG (3.1mm² - 1.3mm²) copper wire only. HAZARD OF EQUIPMENT DAMAGE Do not Megger test C-Bus data cabling or terminals. Megger testing can result in equipment damage. Failure to follow this instruction will result in damage to the C-Bus network. 2007 Schneider Electric. All Rights Reserved. 11

Square D Clipsal DIN Rail Mounted Power Supply, 350mA 63249-420-204A2 Instruction Bulletin 04/2007 STATUS INDICATORS The Power Supply has 2 green indicator lights on the front. Unit Status Indicator - shows the status of the individual unit. C-Bus Network Status Indicator - shows the status of the C-Bus network at this unit. Figure 5: Status Indicators KEY: A. Unit Status Indicator B. C-Bus Network Status Indicator Unit Status Indicator This indicator shows the status of the individual unit. When the unit is connected to a properly operating C-Bus network, the unit status indicator will display a continuous green light (ON). Table 3: Unit Status Indicator Definitions Indicator Status On Off Meaning Normal operation No C-Bus connected 12 2007 Schneider Electric. All Rights Reserved.

63249-420-204A2 Square D Clipsal DIN Rail Mounted Power Supply, 350mA 04/2007 Instruction Bulletin C-Bus Status Indicator This indicator shows the status of the C-Bus network at the unit. If sufficient network voltage and a valid C-Bus clock signal are present then the C-Bus status indicator will display a continuous light (ON). If a network is connected that has more current load than the power supplies can support, then this indicator will flash to show a marginal network voltage. If there is no C-Bus clock then this indicator will not light. NOTE: The C-Bus indicator does not function when standalone programming is being performed on a unit powered by the C-Bus network. Table 4: C-Bus Status Indicator Definitions State ON Flashing OFF Definition Power on and functional Insufficient power to support network No external electrical power source. Indicator does not function if unit is powered only by C-Bus network, e.g., during configuration No C-Bus clock signal present 2007 Schneider Electric. All Rights Reserved. 13

Square D Clipsal DIN Rail Mounted Power Supply, 350mA 63249-420-204A2 Instruction Bulletin 04/2007 STANDARDS The Power Supply complies with the following Standards: Table 5: U.S. and Canadian Product Safety Standards and U.S. FCC Regulations Standards/Regulations CSA C22.2 No. 205 Title Signal Equipment UL916 Energy Management Equipment FCC Part 15 Class B Digital Device for Home or Office Use 14 2007 Schneider Electric. All Rights Reserved.

63249-420-204A2 Square D Clipsal DIN Rail Mounted Power Supply, 350mA 04/2007 Instruction Bulletin SPECIFICATIONS Table 6: Specifications Catalog Number SLC5500HPS SLC5500TPS Nominal Supply Voltage 277Vac ± 10% 110-120Vac ± 10% Frequency Range(s) C-Bus Supply Voltage C-Bus Current Output DC Output Resistance (approximate) AC Input Impedance Electrical Isolation Status Indicators 50/60Hz 15-36V DC @ 350mA Sources 350mA to the C-Bus network with load-side power connected 22 Ohms >60k Ohms @1kHz 3.75kV RMS from C-Bus to Line voltage C-Bus Network Status On Flashing Off Unit: Voltage =/> 20V DC Voltage < 20V DC Voltage < 15V DC or no clock signal On Off Max. Number of Units on a Single C-Bus Network Load Rating Power Supply Type Quiescent Power Warm Up Time Dimensions Line-side Terminals Weight C-Bus Connections Normal No C-bus connected 5 350mA (Can support up to 15 units @ 22mA each on the C-Bus Network. High Impedance Switch Mode Power Supply 15 Watts Max. 3 sec 2.84 x 3.35 x 2.6 in. (72 x 85 x 65 mm) Accommodates #12-16 AWG (3.1mm² - 1.3mm²) copper wire only. 7oz (200g) 2 x RJ45 sockets Operating Temperature Range 32-104 F (0-40 C) Operating Humidity Range 95% RH, Non-condensing 2007 Schneider Electric. All Rights Reserved. 15

Square D Clipsal DIN Rail Mounted Power Supply, 350mA Instruction Bulletin Dimensions Figure 6: Dimensions - DIN Rail Power Supply SUPPORT AND SERVICE Contact the Square D Customer Information Center for technical support by phone at 1-888-Square D (1-888-778-2733) or e-mail at lightingcontrol.support@us.schneider-electric.com. Contact your local Square D service representative or Square D Clipsal certified installer for repairs or service to your network. You may also find helpful information on our web site at www.squaredlightingcontrol.com. Schneider Electric, USA 295 Tech Park Drive La Vergne, TN, 37086 1-888-SquareD (1-888-778-2733) www.squaredlightingcontrol.com Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. Square D,, Clipsal, and C-Bus, are trademarks or registered trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries. 2007 Schneider Electric. All Rights Reserved. 63249-420-204A2 04/2007