Disconnect and lock out electrical service before conducting any work to pump and/or gear motor.

Similar documents
300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

IMPORTANT SAFETY NOTICE

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

BOWIE PUMPS OPERATION - MAINTENANCE

OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE

OPERATION & MAINTENANCE MANUAL. for VERTICAL INLINE PUMPS

A Guide to Trouble-Free Cooling Towers

Maintenance and Service Instruction

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Pump Maintenance - Repair

2" & 3" Poly Wet Seal Pump Instruction Manual

Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE

OPERATION ASSEMBLY INSTRUCTIONS AND PARTS LIST FOR L10 DRIVE END (FRAME SIZES 1L10, 2L10, 3L10, 1L10H, 2L10H, 3M8, 3P6, 6P6, 9P6)

Tri-Homo Style Operation and Maintenance Instructions

SJT / SJM / SJP Large Vertical Pumps

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

Oil and Coolant Circulating Heating System. Model - OCSM

300 Series PA Pump and Cooler Assemblies

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

STEERING SYSTEM - POWER

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

This instruction is valid for all ACD pump models shown on page 2

GENERAL INSTALLATION, OPERATION, MAINTENANCE AND TROUBLESHOOTING MANUAL FOR THREE SCREW AND CIG SERIES PUMPS

Trouble Shooting. Pump

Installation and Start-up Instruction

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

Diesel Engine Driven Generators Page 1 of 6

Troubleshooting for: Premier Supplier of Pumps & Parts

GT Horizontal Split Casing Pumps

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Standard Hydraulic Piping Flushing Procedure

Mechanical shaft seal types and sealing systems

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

BERMAD Fire Protection

Vertical selfpriming Side-Channel Pumps Type WPV

This instruction is valid for all ACF/UCF pump models shown on page 2

AC Electric Motors best practice

VERTICAL TURBINE AND PROPELLER PUMPS

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Rexroth Hydraulic Pump A10VO Series User Manual

TECHNICAL SERVICE MANUAL

BERMAD Fire Protection

CORNELL PUMPS IRRIGATION FOOD MUNICIPAL PROCESS INDUSTRIAL

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Series 1510 and 1510/Universal Centrifugal Pumps

TECHNICAL ADVISORY BULLETIN

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

CHAPTER 65 TAIL ROTOR DRIVE SYSTEM. Section Title Page

Fire Pump Plan Review March 2010

Fire Hydrant Troubleshooting

Viking Pump with Motor and Gear Reduction Drive

SINGLE STAGE INLINE FIRE PUMP

Pump and Valve Components and Maintenance

GENERAL INSTALLATION, OPERATION, MAINTENANCE AND TROUBLESHOOTING MANUAL FOR IMO PUMP TWO SCREW PRODUCTS

CHAPTER. Fire Pumps FIRE PUMP OVERVIEW. Fire Pump Unit Defined. Fire Pump Unit Responsibility

Rotary Pump Startups. A pre-startup guide that will help keep gremlins away from your system. By James R. Brennan

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

855 centrifugal pumps

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

OPERATION & MAINTENANCE MANUAL. for 5 X 3 MAC - 5 X 4 MAC DOUBLE SUCTION SPLIT CASE PUMPS

VERTICAL AND HORIZONTAL END SUCTION PUMPS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Model 854/856. Operating and Assembly Manual. Palmor Products Inc Serum Plant Road Thorntown, IN 46071

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS

UNITS Units are designated by the unmounted pump model numbers followed by a letter indicating drive style.

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

SERIES 127A AND 4127A STAINLESS STEEL SIZES H, HL, K, KK, L, LQ, LL CONTENTS UNMOUNTED PUMP UNITS

OP300S / OP350 2:1 RATIO TRANSFER PUMP

Installation, Operation, Repair and Parts Manual

SUPER-TITAN. Split-case pumps with power, performance and reliability for a world of applications

2100 AD Mirror Elevator Ball Nut Replacement Procedure

Uniquely designed and engineered specifically for the pulp and paper industry.

Mechanical Installation

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

John Crane Type 5610 and 5610Q Single O-Ring Cartridge Seal Assembly and Installation Instructions

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Chapter 7 Hydraulic System Troubleshooting

Action Plan Template HVAC Page 1

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

FOREWORD. Right and left as used throughout this manual are determined by facing the direction the machine will travel when in use.

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Bell & Gossett Parts List DHP-650-PL. Replacement Parts for Hoffman Series VBF & Hoffman Series HBF. Boiler Feed Units

MODEL 341A SINGLE STAGE END SUCTION PUMPS

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Consortiwm Awdurdodau Lleol Cymru Consortium Local Authorities Wales

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

Rental Services Temporary Cooling - Flexible Water Hose

ENGINE COOLING SYSTEM

Transcription:

Maintenance and Lubrication seepex recommends using seepex joint grease type 30321 with all seepex pumps with pin joints. There is no equivalent for this grease, as stated on page 5 of the seepex Operating and Assembly Manual. Also, an operation guarantee cannot be granted if other greases are used. Safety Precautions Disconnect and lock out electrical service before conducting any work to pump and/or gear motor. Close all valves on suction and discharge piping before conducting any work on pump. Ensure coupling guards and motor fan covers are in place before unlocking electrical connections. Take care when removing holding bands from universal joints as edges can be sharp. Ensure that splash ring (slinger ring) is always in proper position on plug-in shaft. Exercise extreme care when adjusting packing as shaft is rotating. Lubrication Schedule Item Action Frequency Type of Lubricant Gear Reducer Check oil level Weekly 210cSt @ 40 C (Gulf EP Lube-S 100/equal) Change Oil 3 years 210 cst @ 40 C (Gulf EP Lube-S 100/equal) Motor Bearing Repack with grease 3 years Gulf EP No. 2/equal Pump Bearing Repack 3,000 operating hours Shell Alvania EP Pump Universal Joints Repack Rotor replacement or 10,000 operating hourswhichever is first 2/equal seepex special grease ONLY

Page 2 Maintenance Schedule Item Action Frequency Remarks Packing Check leakage rate and tighten/loosen to allow 1-6 drops per minute Weekly Adjust tightening nuts only 1/2 turn per minute until stabilized Water Flush Pump Rate Check flow and pressure Check flow at rated pressure Weekly Weekly Replace rotor/stator as required Bearings Check end play and temperature. Change grease. Monthly (3,000 operation hours) See operating manual Universal Joints Check seal integrity. Check bushing and joint wear. Replace grease. Upon rotor/stator replacement Motor Check RPM/amperage. Drain. Check fan cover for obstruction/dirt. Monthly Gear Reducer Check temperature and oil level Monthly Exchange oil 3 years

Page 3 seepex Pre-Start-Up Check List Piping inspection complete check for foreign debris All the flanges must be checked insuring they are tight Are seal lines connected to the pump glands? Check couplings for connection and proper attachment Check belts for proper tension - no appreciable deflection is permitted for initial start-up Check guards for secure positioning and any other protective devices must be secured Pump to be primed Drivers supplied must be checked for oil if supplied with gearboxes Clean all hazardous debris or equipment from area Check electrical connections and conduit boxes on drivers Check pump rotation - normal rotation CCW Pipe lines open, check for liquid to pump suction Check that all valves are open Suction lift applications - insure liquid in pump suction Turn on seal water flush if flush is used If leakage is excessive at packing after 15 minutes, retighten packing periodically 1/4 turn until 1-2 drops per minute is obtained. Do not over tighten to eliminate leakage with packing. Pump rotation is indicated on bearing frame Unlock lockout on panel and at pump Check amps of driver Check pump in manual mode Check pump in auto mode Check for vibration, check gauges, etc. Avoid dry run during operation Check the pump to prevent overpressure

Page 4 Pump Shutdown Procedure Disconnect power to pump driver local or as required Close discharge valves Close suction valves Shut of seal water system water supply Equipment Shutdown Longterm Shutdown - isolate pump and electrical Rotate pump shaft once per week Remove drain plug to facilitate drying of suction housing Prevent freezing at pump, drain and protect from freezing. Fill with light oil or ethylene glycol. It must be compatible with pump elastomers. Buna, EPDM, Viton are compatible with ethylene glycol. Put grease into stuffing box. If packing is used loosen packing. Use light oil for mechanical seal protection If pump is not installed, place blind flanges over suction and discharge flanges Store pump in cool, dry atmosphere Grinder Start-Up Checklist Turn on seal water flush to grinder Open suction and discharge valves - starting flow of liquid Start the seerator/grinder Start the pump used with the seerator/grinder Grinder Shutdown Peocedures Stop the pump associated with the grinder Stop the grinder Close suction and discharge valves Shutdown seal water system

Page 5 Stator Retensioning Procedures The pump must be calibrated when new, and recalibration can be based upon either fluid flow or motor amperage. Record the following data upon installation and start-up of the new pump. Calibration fluid cps viscosity RPM PSIG (discharge) PSIG (inlet) F temperature % solids motor amperes or/ GPM particle size Ensure all operating parameters, except motor amperage or flow rate, are as originally calibrated... including fluid levels on the suction and discharge side of the pump, piping conditions, fluid viscosity or solids contents and temperature... before testing for stator wear. DO NOT calibrate pump and test for stator wear on two different fluids. DO NOT adjust stator unless pump is tested against calibration performance. DO NOT adjust stator unless its tested performance at its calibrated conditions show a 40% or greater drop in flow or amperage. NOTE: On applications with viscous materials and long pipe lengths, it may not be possible to record test pressure readings identical to the calibration readings due to the high frictional component of total system pressure. Ensure that suction and discharge static head conditions and piping arrangements have not been changed since the last calibration procedure. Every time any change is made to either the suction or discharge piping or every time the pumped fluid is changed, the pump must be recalibrated. Once the above conditions are verified, tighten the nuts on the stator retensioning device one-half turn each, starting on the discharge side of the pump and alternating left to right sides. DO NOT tighten all the nuts on one side and then tighten the nuts on the other side. Check test performance. If tested performance is less than 90% of calibrated performance, retighten nuts following procedures described previously. DO NOT tighten nuts to achieve more than 90% of calibrated performance. Wear has occurred on the pumping elements and the formed cavity is slightly smaller. Increased performance above 90% of calibrated levels can only be achieved by increasing the pump speed. Over tightening will cause premature wear and component failure. DO NOT use discharge pressure as an indicator of pump performance. Pressure indicates piping and fluid conditions and is not a valid indicator of performance for a positive displacement pump. If pressures are significantly different from those recorded during calibration, check for changes to the piping and fluid consistency. When the stator can no longer be tightened, it should be replaced. Once the stator is removed, carefully inspect and measure the rotor for wear. Call seepex to obtain the proper dimensions and procedures to check for rotor wear. Rotor wear should not exceed 0.012 it should be replaced.

Page 6 Note: Pumps with the stator retensioning device often require both the rotor and stator to be changed at the same time. Replacement stators for pumps with the stator retensioning device usually do not need to be adjusted when installed. This is especially true when a new rotor has also been installed. Always check for rotor wear before installing a new stator. Test the new stator performance using the same test procedures used to test a worn stator. If the performance needs to be improved, follow the tightening procedures outlined above. Again, as a precaution, do not tighten to achieve more than 90% of the calibrated performance, in an effort to avoid over tightening and premature wear.