ROSETTA BELVEDERE RETAINING WALL SYSTEM

Similar documents
SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL. Featuring Highland Stone. anchorwall.com

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

Specification Guidelines: Allan Block Modular Retaining Wall Systems

1. ASTM C Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION EARTH MOVING

DESIGN GUIDELINES FOR EARTH RETENTION

The Verdura Wall check with your local building department

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

How To Build A Wall System

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

How To Retaining Wall Guide

Division 2 Section Section 02795

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

Storm Drain Inlet Protection - IP

PERMEABLE INTERLOCKING CONCRETE PAVEMENT

GUIDE SPECIFICATIONS FOR CONSTRUCTION OF AQUAPAVE PERMEABLE STORMWATER MANAGEMENT SYSTEM

Construction Specification for Concrete Curb and Concrete Curb and Gutter

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

Designed and Engineered to Perform

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

SECTION UNI PERMEABLE INTERLOCKING CONCRETE PAVEMENT

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES

TORO STEEL BUILDINGS. BOLTS: o " diam. x " diam. x " diam. C.J. - Control Joints to minimize cracking.(0.

Settlement of Precast Culverts Under High Fills; The Influence of Construction Sequence and Structural Effects of Longitudinal Strains

Chapter 3 Pre-Installation, Foundations and Piers

RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas

SECTION 1 GENERAL REQUIREMENTS

How to Install Pavers

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Precast Modular Block (PMB) for Retaining Wall Systems

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio

Lighthouse Engineering, L.L.C.

Design Ideas by Allan Block

Earth Pressure and Retaining Wall Basics for Non-Geotechnical Engineers

Permeable Pavement Construction Guide

C. Section TESTING LABORATORY SERVICE.

Section 2100-Trenching and Tunneling

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

BMP 6.4.6: Dry Well / Seepage Pit

Soil depth: meters Type of restrictive layer:

Installation PowerPoint for Grasscrete Formers

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

Emergency Spillways (Sediment basins)

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

COSMOS 2012: Earthquakes in Action COSMOS 2012

THE OBJECTIVES OF ROUTINE ROAD CUTS AND FILLS

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone

Building Your Interlocking Concrete Pavement to Last a Lifetime

Sample Punch List. Garth Ruffner Landscape Architect (916) Page 1 of 5

Section 402. STORM SEWERS

Safe & Sound Bridge Terminology

SECTION PRECAST MODULAR BLOCK GRAVITY RETAINING WALL

The Most Advanced Name in Drainage Systems. Geotextile Products

SUDAS Revision Submittal Form

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Reflectex TM Reflective Concrete Interlayer Geotextile INSTALLATION GUIDELINES

Caltrans non-standard Special Provisions Pervious Concrete. David Akers Feb 28, 2012

SECTION PRECAST MODULAR BLOCK RETAINING WALL

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

SECTION STORM DRAINAGE TABLE OF CONTENTS

Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05

Installation Guidelines for Segmental Block Wall. Contents 1. INTRODUCTION MATERIALS... 2

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Land Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

SECTION 311 PLACEMENT AND CONSTRUCTION OF CEMENT TREATED SUBGRADESOIL CEMENT BASE COURSE

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair

Stormwater/Wetland Pond Construction Inspection Checklist

DIVISION 300 BASES SECTION 304 AGGREGATE BASE COURSE DESCRIPTION MATERIALS CONSTRUCTION REQUIREMENTS

INSTALLATION GUIDE. americanwick.com WICK (9425)

Residential Foundations and Basements

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems

Module 7 (Lecture 24 to 28) RETAINING WALLS

Minimizes sediment and debris from entering storm drains that lead to waterways and watercourses.

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

5/1/2013. Topics. The challenge is to better maintain native characteristics of soils during and after construction

Table 4.9 Storm Drain Inlet Protetion Applicable for

High Strain Dynamic Load Testing of Drilled Shafts

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

SECTION STORM DRAIN SYSTEM

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

Transcription:

ROSETTA ST. LOUIS COUNTY MASTERPLAN INDEX OF DRAWNGS: SHEET SHEET 2 SHEET SHEET 4,5 & 6 SHEET 7 SHEET 8 SHEET 9 SHEET 0 COVER SHEET APPLICATIONS AND DESIGN INFORMATION SPECIFICATIONS DETAILS STANDARD DESIGN - FLAT BACKFILL STANDARD DESIGN - TRAFFIC SURCHARGE STANDARD DESIGN - SLOPING BACKFILL STANDARD DESIGN - TIERED WALLS COVER SHEET SHEET OF 0

APPLICATION: THE IS A STRUCTURE COMBINING AN ARCHITECTURALLY ATTRACTIVE CONCRETE FACING BLOCK WITH OR WITHOUTH GEOGRID REINFORCEMENT. THE GEOGRID REINFORCEMENT INTERLOCKS WITH THE BLOCK UNITS AND FILL SOIL TO CREATE A STABLE RETAINING WALL. DESIGN OF THESE REINFORCED SOIL STRUCTURES USES WELL ESTABLISHED GUIDELINES THAT ARE READILY AVAILABLE. THE FOLLOWING SPECIFICATIONS AND DETAILS PROVIDE A DESIGN TO INCORPORATE GEOGRID REINFORCEMENT INTO THE SOIL FOR THE PURPOSES OF CONSTRUCTING RETAINING WALLS. CONSULT MIDWEST BLOCK AND BRICK FOR ADDITIONAL DETAILS REGARDING DESIGN, APPEARANCE AND AESTHETIC CONSIDERATIONS. STANDARD DESIGN PROCEDURE: THE FOLLOWING DESIGN TABLES ESTABLISHED FOR THE CONSTRUCTION OF SOIL REINFORCED WALLS ARE BASED UPON GENERALLY ACCEPTED SOIL PARAMETERS IN THE ST LOUIS COUNTY, MISSOURI AREA. ALL SOIL PARAMETERS ASSUMED IN THE DESIGN ARE WELL DRAINED, LONG TERM STRENGTH CONDITIONS. HIGH PLASTIC SILTS AND CLAYS SHOULD BE AVOIDED WITHOUT SPECIFIC DESIGN RECOMMENDATIONS FROM LOCAL GEOTECHNICAL ENGINEERS. FROST HEAVE AND SETTLEMENT NEED TO BE ADDRESSED IF WARRANTED BY CONDITIONS. ALSO, SPECIFIC PRECAUTIONS ARE NECESSARY FOR WALLS CONSTANTLY IN CONTACT WITH WATER, I.E. NEAR OR AT RIVERS, LAKES AND PONDS. FOUR TYPICAL GEOMETRIC CASES WERE SELECTED FOR THESE TABLES. THE FIRST CASE IS A TYPICAL RETAINING WALL WITH HORIZONTAL BACKFILL AND NO SURCHARGE, THE SECOND CASE IS A TYPICAL RETAINING WALL WITH HORIZONTAL BACKFILL AND 00 PSF SURCHARGE, THE THIRD CASE IS A : SLOPING BACKFILL AND THE FOURTH CASE IS A TIERED WALL WITH FLAT BACKSLOPE AND NO SURCHARGE. THE FOLLOWING IS A SUMMARY OF THE DESIGN PARAMETERS USED AND THE FACTORS OF SAFETY WHICH THE DESIGNS ARE BASED ON. SOIL PROPERTIES: FRICTION ANGLE UNIT WEIGHT COHESION (DEGREES) (LBS/CF) (LBS/SF) WALL FILL 28 20 0 RETAINED BACKFILL 28 20 0 FOUNDATION SOIL 28 20 0 FRICTION ANGLE - DEGREES UNIT WEIGHT - LBS PER CUBIC FOOT COHESION - LBS PER SQUARE FOOT FACTORS OF SAFETY CALCULATED: REINFORCEMENT PULLOUT =.5 REINFORCEMENT RUPTURE =.5 EXTERNAL SLIDING =.5 INTERNAL SLIDING =.5 OVERTURNING = 2.0 BEARING CAPACITY =,500 PSF APPLICATIONS SHEET 2 OF 0

SPECIFICATIONS - St. Louis County, Missouri Masterplan MATERIALS RETAINING WALL UNITS SHALL BE ROSETTA BLOCK UNITS AS MANUFACTURED BY MIDWEST BLOCK AND BRICK. THE WALL SYSTEM CONSISTS OF (6) WALL UNITS OF VARIOUS SIZES, EACH BEING 9" DEEP. CONCRETE WALL UNITS SHALL MEET THE REQUIREMENTS OF ASTM C72 AND BE MADE FROM WET CAST, READY-MIXED CONCRETE IN ACCORDANCE WITH ASTM C-94. UNITS SHALL HAVE A SPECIFIED 28 DAY COMPRESSIVE STRENGTH OF 4,000 PSI. THE REINFORCED WALL BACKFILL MATERIAL SHALL BE COMPACTED SOIL FROM ON-SITE. THE SOIL SHALL BE FREE OF DEBRIS, CLUMPS, ROCKS LARGER THAN 4", AND ANY ORGANIC OR FROZEN MATERIALS. DO NOT USE HIGH PLASTIC SOILS THAT HAVE A PI>20 OR LL>40. GEOGRID SHALL BE MIRAGRID 2XT OR XT AS MANUFACTURED BY TENCATE GEOSYNTHETICS; STRATA SG50 OR SG200 AS MANUFACTURED BY STRATA SYSTEMS, INC; OR SYNTEEN SF20 OR SF5 AS MANUFACTURED BY SYNTEEN TECHNICAL FABRICS, INC. THE GEOTEXTILE FILTER FABRIC SHALL BE A NONWOVEN FABRIC WITH A WEIGHT OF.5 OZ/SY. THE LEVELING PAD SHALL BE WELL-GRADED, CRUSHED LIMESTONE SIMILAR TO " MINUS. THE DRAINAGE ROCK SHALL BE FREE-DRAINING ROCK SUCH AS /4" CRUSHED LIMESTONE. THE PERFORATED PIPE SHALL BE 4" DIAMETER HDPE COIL PIPE. WALL FOUNDATION FOUNDATION SOIL SHALL BE EXCAVATED AS REQUIRED FOR THE LEVELING PAD AND THE REINFORCED FILL ZONE TO THE DEPTHS AND LOCATIONS SHOWN ON THE PLAN SHEET. WALLS SHALL HAVE THE BOTTOM COURSE(S) BURIED TO A DEPTH OF 6. THE EXPOSED FOUNDATION SOIL SHALL BE OBSERVED PRIOR TO CONSTRUCTION TO VERIFY THAT THE EXPOSED MATERIAL IS SUITABLE FOR A NET DESIGN BEARING PRESSURE OF 2000 PSF AND THAT THE BASE OF THE EXCAVATION IS FREE OF LOOSE SOIL, UNCOMPACTED FILL, WATER, OR FROZEN MATERIAL. CONSULT A SOILS ENGINEER IF IN DOUBT. UNDERCUT ANY UNSUITABLE SOIL. UNDERCUT AREAS SHALL BE FILLED WITH CRUSHED LIMESTONE AND COMPACTED TO AT LEAST 95% OF THE MATERIAL'S STANDARD PROCTOR MAXIMUM DRY DENSITY. EXISTING FOUNDATION SOIL (SOIL BELOW WALL) SHOULD BE COMPACTED TO A OF 95% OF STANDARD PROCTOR BEFORE LEVELING PAD MATERIAL IS INTRODUCED. CONSTRUCT THE CRUSHED ROCK LEVELING PAD TO LINES AND GRADES SHOWN ON THE PLANS. COMPACT USING A VIBRATOR PLATE COMPACTOR. INSTALL A 4 (00 MM) DIAMETER PERFORATED DRAIN PIPE BEHIND THE BASE UNIT AND IN THE DRAINAGE LAYER. DAYLIGHT THE DRAIN PIPE AT THE ENDS AND/OR THROUGH THE FACE OF THE WALL TO ALLOW FOR DRAINAGE. WALL CONSTRUCTION PLACE THE BOTTOM COURSE OF WALL BLOCKS. TAKE CARE TO LEVEL THE BLOCKS BOTH PARALLEL AND PERPENDICULAR TO THE WALL. PLACE SUCCESSIVE UNITS, DRAINSTONE, AND COMPACTED BACKFILL TO THE DESIRED GRADE/ WALL HEIGHT. MAKE SURE THE WALL BLOCKS ARE SETBACK A OF /2" FOR EVERY OF WALL HEIGHT. COPING LAYER SHOULD BE ADHERED WITH A CONCRETE ADHESIVE. GEOGRID REINFORCING GEOGRID SHALL BE CUT TO DESIGN LENGTHS AND PLACED BETWEEN THE BLOCKS AT THE ELEVATIONS SHOWN ON THE PLANS. THE GEOGRID'S PRIMARY STRENGTH DIRECTION WILL BE DIRECTED PERPENDICULAR TO THE WALL FACE (INTO THE FILL.) GEOGRID PLACED OUTSIDE A PLUS OR MINUS 4" ZONE OF THE GEOGRID DESIGN ELEVATION WILL NOT BE ACCEPTED. THE GEOGRID SHALL BE PLACED HORIZONTALLY AND LAY FLAT ON THE REINFORCED FILL SOIL. GEOGRID SHALL BE PLACED STARTING AT THE FACE OF THE RETAINING BLOCK AND EXTENDING INTO THE REINFORCED SOIL. MAKE SURE THE GEOGRID IS AS CLOSE AS POSSIBLE TO THE FRONT FACE OF THE WALL WITHOUT BEING VISIBLE. USE THE NEXT LAYER OF BLOCKS TO SECURE THE FRONT END OF THE GEOGRID. PULL THE GEOGRID TAUT TO ELIMINATE ANY FOLDS AND PRETENSION THE GEOGRID. PIN OR SECURE THE BACK EDGE OF THE GEOGRID BEFORE PLACING THE REINFORCED FILL. FOLLOW GEOGRID MANUFACTURER'S REQUIREMENTS, INCLUDING REQUIREMENTS FOR VERTICAL SEPARATION AND OVERLAP OF GEOGRID. WALL BACKFILL WALL BACKFILL MATERIAL SHALL BE PLACED IN MAXIMUM LOOSE LIFTS AND COMPACTED TO AT LEAST 95% OF THE MATERIAL'S MAXIMUM DRY DENSITY AS DETERMINED BY THE STANDARD PROCTOR METHOD. BACKFILL SHALL BE PLACED, SPREAD, AND COMPACTED IN SUCH A MANNER THAT MINIMIZES WRINKLES AND MOVEMENT OF THE GEOGRID. FIELD DENSITY TESTING SHALL BE CONDUCTED BY A QUALIFIED SOILS TECHNICIAN TO VERIFY THAT AT LEAST THE DEGREE OF COMPACTION IS BEING OBTAINED. PLACE 2" OF DRAINAGE ROCK BEHIND UNITS. BACKFILL THE FIRST 2" (00 MM) BEHIND THE BLOCKS AND TRIANGLE SHAPED AREAS BETWEEN THE BLOCKS WITH ASTM NO. 57 DRAINSTONE. PLACE A LAYER OF NON-WOVEN GEOTEXTILE FABRIC IMMEDIATELY BEHIND THE DRAINSTONE AND THEN PLACE THE RETAINED OR REINFORCED SOIL. DURING BACKFILL PLACEMENT THE FOOT ZONE DIRECTLY BEHIND THE WALL SHALL BE LIMITED TO THE USE OF HAND OPERATED COMPACTION EQUIPMENT ONLY. MONITOR THE WALL BLOCKS FOR MOVEMENT DURING COMPACTION AND RECTIFY IF REQUIRED PRIOR TO PROCEEDING. CONSTRUCTION EQUIPMENT SHALL NOT BE OPERATED DIRECTLY ON THE GEOGRID. PROTECTION OF WORK THE SURFACE OF THE WALL BACKFILL SHALL BE GRADED AT THE END OF EACH DAY OF WORK TO PROVIDE POSITIVE SURFACE DRAINAGE AWAY FROM THE WALL. GRADING SHALL INCLUDE PROPER CONTOURING OF FILLS IN ADJACENT AREAS TO PREVENT THE FLOW OF SURFACE WATER INTO THE REINFORCED EARTH ZONE. THE DESIGN OF THE WALLS ARE BASED ON CONDITIONS AND LOADS IMPOSED ON THE WALL AT COMPLETION OF THE PROJECT. PRIOR TO PROJECT COMPLETION, THE WALL IS VULNERABLE TO DAMAGES CAUSED BY CONSTRUCTION ACTIVITY ADJACENT TO THE WALL. OF PARTICULAR CONCERN IS THE OF GRADING AND PAVEMENT CONSTRUCTION EQUIPMENT ON THE RETAINED BACKFILL AT THE TOP OF THE WALL. ONLY EQUIPMENT WITH A WEIGHT NOT EXCEEDING ONE TON CAN BE USED IN THE FOOT ZONE DIRECTLY BEHIND THE BACK OF THE WALL FACE. THE SOIL IN FRONT OF THE WALLS SHALL BE PROTECTED FROM FUTURE EROSION. THE TOP OF WALL MUST BE GRADED TO DIRECT SURFACE WATER AWAY FROM THE WALL. SPECIFICATIONS SHEET OF 0

WALL BLOCKS COLLECTION WALL BLOCKS ARE PROVIDED IN SIX BASIC SIZES. THE BLOCKS ARE FINISHED ON THE FRONT AND BACK FACES. " 4" (BACK " 0" (BACK " (BACK NOTE: AVERAGE BLOCK WEIGHTS ARE SHOWN. WEIGHTS OF INDIVIDUAL BLOCKS MAY VARY. 4" (BACK 0" (BACK (BACK (FRONT " BLOCK WEIGHT = ±0 LBS 2 PER PALLET 2" (FRONT 5" (TEXTURED BLOCK 2 WEIGHT = ±22 LBS 2 PER PALLET 8" (FRONT BLOCK WEIGHT = ±6 LBS 2 PER PALLET 4" (TEXTURED (FRONT CORNER BLOCKS THE COLLECTION CONTAINS 2 CORNER BLOCKS SIZES. THE BLOCKS ARE FINISHED ON SIDES. THE 4TH SIDE IS TAPERED TO FIT WITH RETAINING WALL BLOCKS. THE CORNER BLOCKS CAN BE USED TO CONSTRUCT COLUMNS, PROVIDE A FINISHED END ON A FREESTANDING WALL, AND TO MAKE 90 CORNERS. BLOCK 4 WEIGHT = ±2 LBS 2 PER PALLET 2" (FRONT BLOCK 5 WEIGHT = ±42 LBS 2 PER PALLET 8" (FRONT BLOCK 6 WEIGHT = ±67 LBS 2 PER PALLET 4" (TEXTURED (TEXTURED BLOCK 7 WEIGHT = ± 0 LBS 6 PER PALLET 5" (TEXTURED (TEXTURED BLOCK 8 WEIGHT = ± 58 LBS 6 PER PALLET COPING BLOCKS (CAPS) COLLECTION COPING BLOCKS ARE PROVIDED IN FIVE BASIC SIZES. THERE ARE THREE STANDARD COPING BLOCKS WHICH ARE FINISHED ON THE FRONT, BACK, AND TOP FACES. THERE ARE ALSO TWO END UNITS WHICH ARE FINISHED ON FRONT, BACK, TOP, AND ONE OF THE SIDES. THE END UNITS ARE USEFUL FOR CONSTRUCTING CORNERS AND WALL ENDS. 0" 2 4" 7" 2 4" 7" (BACK (BACK ± 0 2 4" (TEXTURED 2 4" (BACK 4" (TEXTURED (TEXTURED 4" 90 90 90 90 (FRONT ± 0 4" BLOCK 9 WEIGHT = ±9 LBS 24 PER PALLET 2" (FRONT BLOCK 0 WEIGHT = ±20 LBS 24 PER PALLET ± 0 4" 8" (FRONT ± 0 4" BLOCK WEIGHT = ±0 LBS 2 PER PALLET 8" (TEXTURED BLOCK 2 (LEFT END) WEIGHT = ±29 LBS 6 PER PALLET 2 4" 8" (TEXTURED BLOCK (RIGHT END) WEIGHT = ±4 LBS 6 PER PALLET ± 0 4" (TEXTURED DETAILS SHEET 4 OF 0

TYPICAL RETAINING WALL CONSTRUCTION DETAILS THIS PAGE SHOWS TYPICAL CONSTRUCTION DETAILS FOR RETAINING WALLS. THESE DRAWINGS ARE REPRESENTATIVE OF MAJOR COMPONENTS REQUIRED IN WALL CONSTRUCTION. SPECIFIC DETAILS INCLUDING GEOTEXTILE REINFORCEMENT LAYERS, DRAINAGE DETAILS, SOIL REQUIREMENTS, ETC. SHALL BE PER THE ENGINEERED DESIGN FOR THE WALL. GLUE ALL UNITS ABOVE TOP LAYER OF GEOGRID CAP BLOCK GRADE TO DRAIN AWAY FROM WALL SETBACK WALL BLOCKS /2" EVERY OF HEIGHT (4.8 WALL BATTER) CAP BLOCK GRADE TO DRAIN AWAY FROM WALL GEOTEXTILE FABRIC SETBACK WALL BLOCKS /2" EVERY OF HEIGHT (4.8 WALL BATTER) GEOGRID REINFORCEMENT REFER TO DETAILS FOR LENGTH AND LOCATION COMPACTED SOIL IN REINFORCED EARTH ZONE EXPOSED HEIGHT (VARIES) CRUSHED STONE BACKFILL (ASTM NO. 57) AT ON SLOPE BEHIND BLOCKS RETAINED SOIL EXPOSED HEIGHT (VARIES) DRAINSTONE (ASTM NO. 57) TO EXTEND AT LEAST 2" BEHIND THE BLOCKS RETAINED SOIL 2" GEOTEXTILE FABRIC BURY DEPTH LENGTH OF GEOGRID LAYER (VARIES PER DESIGN) VERTICAL PLACEMENT OF GEOGRID LAYER REFER TO DETAILS VERTICAL PLACEMENT OF GEOGRID LAYER REFER TO DETAILS X8" WELL-GRADED, CRUSHED GRAVEL LEVELING PAD 4" DRAIN PIPE AT BASE OF FIRST UNIT DAYLIGHT AT LOW POINT IN THE WALL TYPICAL SECTION - WITHOUT REINFORCEMENT BACK OF WALL DRAINSTONE BETWEEN AND BEHIND BLOCKS X8" WELL-GRADED, CRUSHED GRAVEL LEVELING PAD 4" DRAIN PIPE AT BASE OF FIRST UNIT DAYLIGHT AT LOW POINT IN THE WALL TYPICAL SECTION - WITH REINFORCEMENT FACE OF WALL TYPICAL BLOCK DETAIL ORIENT BLOCKS AS SHOWN BLOCK SIZES AND PLACEMENT SHOWN ARE FOR REFERENCE ONLY. INDIVIDUAL BLOCKS WILL VARY WITH INSTALLATION PATTERN. TYPICAL SECTIONS SHEET 5 OF 0

CORNER DETAILS THIS PAGE SHOWS TYPICAL CONSTRUCTION DETAILS FOR MAKING 90 CORNERS WITH BLOCKS. SOME BASIC CONCEPTS ARE SHOWN HERE. PLAN TO TAKE SOME TIME TO PROPERLY WORK CORNERS INTO THE LARGER RETAINING AND FREESTANDING WALL PATTERNS. WALLS ARE SHOWN WITHOUT BATTER FOR CLARITY. BLOCKS IN A RETAINING WALL SHOULD BE ADJUSTED SLIGHTLY IN PLACE AND TRIMMED AS NEEDED TO ALLOW WALL CONSTRUCTION WITH A PROPER BATTER. BOTTOM BLOCK HIDDEN (SEE INTERLOCKING CORNER DETAIL) OUTSIDE CORNER INSIDE STEPS THIS PAGE SHOWS TYPICAL CONSTRUCTION DETAILS FOR MAKING STAIR OPENINGS INTO A WALL USING BLOCKS AND ROSETTA DIMENSIONAL STEPS. WALLS ARE SHOWN WITHOUT BATTER FOR CLARITY. BLOCKS IN A RETAINING WALL SHOULD BE ADJUSTED SLIGHTLY IN PLACE AND TRIMMED AS NEEDED TO ALLOW WALL CONSTRUCTION WITH A PROPER BATTER. THE INSIDE WINGWALLS ARE TYPICALLY CONSTRUCTED WITHOUT BATTER TO MATCH THE STEPS. INSIDE CORNER PLACE BLOCKS IN AN OVERLAPPING, INTERLOCKING PATTERN AT CORNER FOR ADDED WALL STABILITY. INTERLOCKING CORNER CURVED WALLS THIS PAGE SHOWS TYPICAL CONSTRUCTION DETAILS FOR MAKING CURVED RETAINING WALLS WITH BLOCKS. THE TAPER ON THE SIDES OF THE BLOCKS ALLOW FOR CONSTRUCTION OF A WIDE RANGE OF CURVES IN BOTH RETAINING AND FREESTANDING WALLS. WALLS ARE SHOWN WITHOUT BATTER FOR CLARITY. BLOCKS IN A RETAINING WALL SHOULD BE ADJUSTED SLIGHTLY IN PLACE AND TRIMMED AS NEEDED TO ALLOW WALL CONSTRUCTION WITH A PROPER BATTER. MIN. RADIUS = 4'- OUTSIDE CURVE INSIDE CURVE RADIUS VARIES TRIM BLOCKS AS NEEDED TO TRANSITION FROM OUTSIDE TO INSIDE CURVES (4'- RECOMMENDED) MIN. DIAMETER = 9'-0" MIN. RADIUS = 4'- PLANTER / TREE RING DETAILS SHEET 6 OF 0

PRELIMINARY WALL HEIGHT GUIDES THIS PAGE SHOWS GUIDES FOR THE SOIL REINFORCEMENT REQUIRED TO CONSTRUCT A WALL WITH COLLECTION BLOCKS SHOWN IN THE CONDITIONS NOTED. THE GEOGRID LAYERS SHOWN SHALL BE PLACED WITH 00% COVERAGE ALONG THE LENGTH OF THE WALL (NO GAPS BETWEEN SECTIONS OF GRID). SEE TYPICAL SECTIONS AND SPECIFICATIONS FOR TYPICAL CONSTRUCTION NOTES. BLOCK SIZES AND PLACEMENT SHOWN ARE FOR REFERENCE ONLY. INDIVIDUAL COLLECTION BLOCKS WILL VARY WITH INSTALLATION PATTERN. NO BACKSLOPE NO SURCHARGE GEOGRID REINFORCEMENT IS MIRAGRID 2XT OR XT; STRATA SG50 OR SG200; OR SYNTEEN SF20 OR SF5. LENGTH OF GEOGRID IS MEASURED FROM THE FRONT OF THE BLOCKS. VERTICAL PLACEMENT (VP) OF GEOGRID IS MEASURED UP FROM THE BOTTOM OF THE BLOCKS/TOP OF THE STONE LEVELING PAD. '- MAX. WALL W/O REINFORCEMENT CRUSHED STONE BACKFILL VP = '-0" LENGTH = '-0" VP = LENGTH = VP = LENGTH = VP = '- LENGTH = 5'-0" VP = 4'- LENGTH = 5'-0" VP = 5'-0" LENGTH = 5'-0" VP = LENGTH = 5'-0" VP = '- LENGTH = 6'-0" VP = '- LENGTH = 5'-0" VP = LENGTH = VP = LENGTH = 5'-0" VP = LENGTH = VP = LENGTH = VP = LENGTH = 5'-0" FLAT BACKFILL SHEET 7 OF 0

PRELIMINARY WALL HEIGHT GUIDES THIS PAGE SHOWS GUIDES FOR THE SOIL REINFORCEMENT REQUIRED TO CONSTRUCT A WALL WITH COLLECTION BLOCKS SHOWN IN THE CONDITIONS NOTED. THE GEOGRID LAYERS SHOWN SHALL BE PLACED WITH 00% COVERAGE ALONG THE LENGTH OF THE WALL (NO GAPS BETWEEN SECTIONS OF GRID). SEE TYPICAL SECTIONS AND SPECIFICATIONS FOR TYPICAL CONSTRUCTION NOTES. BLOCK SIZES AND PLACEMENT SHOWN ARE FOR REFERENCE ONLY. INDIVIDUAL COLLECTION BLOCKS WILL VARY WITH INSTALLATION PATTERN. NO BACKSLOPE LIGHT TRAFFIC SURCHARGE (NO TRUCKS) (00 PSF) GEOGRID REINFORCEMENT IS MIRAGRID 2XT OR XT; STRATA SG50 OR SG200; OR SYNTEEN SF20 OR SF5. LENGTH OF GEOGRID IS MEASURED FROM THE FRONT OF THE BLOCKS. VERTICAL PLACEMENT (VP) OF GEOGRID IS MEASURED UP FROM THE BOTTOM OF THE BLOCKS/TOP OF THE STONE LEVELING PAD. VP = '-0" LENGTH = VP = 2'- LENGTH = '-0" VP = LENGTH = VP = '-0" LENGTH = '-0" VP = '- LENGTH = VP = LENGTH = VP = '-0" LENGTH = 5'-0" VP = LENGTH = 5'-0" VP = 5'- LENGTH = 6'-0" VP = 4'- LENGTH = 5'-0" VP = LENGTH = 5'-0" VP = 2'- LENGTH = 6'-0" VP = '- LENGTH = 4'- VP = 2'- LENGTH = 4'- VP = '- LENGTH = VP = '- LENGTH = 4'- VP = LENGTH = VP = LENGTH = VP = LENGTH = 4'- TRAFFIC SURCHARGE SHEET 8 OF 0

PRELIMINARY WALL HEIGHT GUIDES THIS PAGE SHOWS GUIDES FOR THE SOIL REINFORCEMENT REQUIRED TO CONSTRUCT A WALL WITH COLLECTION BLOCKS SHOWN IN THE CONDITIONS NOTED. THE GEOGRID LAYERS SHOWN SHALL BE PLACED WITH 00% COVERAGE ALONG THE LENGTH OF THE WALL (NO GAPS BETWEEN SECTIONS OF GRID). SEE TYPICAL SECTIONS AND SPECIFICATIONS FOR TYPICAL CONSTRUCTION NOTES. BLOCK SIZES AND PLACEMENT SHOWN ARE FOR REFERENCE ONLY. INDIVIDUAL COLLECTION BLOCKS WILL VARY WITH INSTALLATION PATTERN. ON (8.5 ) BACKSLOPE NO SURCHARGE GEOGRID REINFORCEMENT IS MIRAGRID 2XT OR XT; STRATA SG50 OR SG200; OR SYNTEEN SF20 OR SF5. LENGTH OF GEOGRID IS MEASURED FROM THE FRONT OF THE BLOCKS. VERTICAL PLACEMENT (VP) OF GEOGRID IS MEASURED UP FROM THE BOTTOM OF THE BLOCKS/TOP OF THE STONE LEVELING PAD. '-0" MAX. WALL W/O REINFORCEMENT CRUSHED STONE BACKFILL VP = '-0" LENGTH = '-0" VP = 2'- LENGTH = VP = '- LENGTH = VP = LENGTH = VP = '- LENGTH = 5'-0" VP = 2'- LENGTH = 5'-0" 5'-0" VP = 4'- LENGTH = 6'-0" VP = '- LENGTH = 5'-0" VP = 2'- LENGTH = 5'-0" 6'-0" VP = 5'- LENGTH = 6'- VP = 4'- LENGTH = 6'-0" VP = '- LENGTH = 6'-0" VP = 2'- LENGTH = 6'-0" VP = '- LENGTH = 5'-0" VP = '- LENGTH = 5'-0" VP = '- LENGTH = 6'-0" VP = LENGTH = 5'-0" VP = LENGTH = 5'-0" VP = LENGTH = 6'-0" SLOPING BACKFILL SHEET 9 OF 0

PRELIMINARY WALL HEIGHT GUIDES THIS PAGE SHOWS GUIDES FOR THE SOIL REINFORCEMENT REQUIRED TO CONSTRUCT A WALL WITH COLLECTION BLOCKS SHOWN IN THE CONDITIONS NOTED. THE GEOGRID LAYERS SHOWN SHALL BE PLACED WITH 00% COVERAGE ALONG THE LENGTH OF THE WALL (NO GAPS BETWEEN SECTIONS OF GRID). SEE TYPICAL SECTIONS AND SPECIFICATIONS FOR TYPICAL CONSTRUCTION NOTES. BLOCK SIZES AND PLACEMENT SHOWN ARE FOR REFERENCE ONLY. INDIVIDUAL COLLECTION BLOCKS WILL VARY WITH INSTALLATION PATTERN. TIERED NO BACKSLOPE NO SURCHARGE GEOGRID REINFORCEMENT IS MIRAGRID 2XT OR XT; STRATA SG50 OR SG200; OR SYNTEEN SF20 OR SF5. LENGTH OF GEOGRID IS MEASURED FROM THE FRONT OF THE BLOCKS. VERTICAL PLACEMENT (VP) OF GEOGRID IS MEASURED UP FROM THE BOTTOM OF THE BLOCKS/TOP OF THE STONE LEVELING PAD. Minimum VP = '-0" LENGTH = VP = '- LENGTH = 5'-0" VP = '- LENGTH = VP = LENGTH = 2' TIERED WALLS VP = LENGTH = VP = LENGTH = '-0" VP = LENGTH = VP = '-0" LENGTH = 5'-0" VP = LENGTH = '-0" VP = LENGTH = 5'-0" STANDARD WALL BURY DEPTH = VP = '- LENGTH = VP = LENGTH = VP = LENGTH = ' TIERED WALLS 4' TIERED WALLS STANDARD WALL BURY DEPTH = TIERED WALLS SHEET 0 OF 0