Validation of. Isopropyl Alcohol Using. SKC Passive Sampler Cat. No

Similar documents
U.S. Department of Labor Occupational Safety & Health Administration

Isopropyl Alcohol (IPA)

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Trade Name of this Product Isopropyl Rubbing Alcohol 91% USP. Corporate Compliance Team 1666 East Touhy Avenue

Cartridge Change Schedule

NITRIC OXIDE and NITROGEN DIOXIDE 6014

Generation of Vapor-Phase Hydrogen Peroxide Test Atmospheres for the Evaluation of Respirator Cartridges and Air Samplers

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

M A T E R I A L S A F E T Y D A T A S H E E T

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

Propane Fuel. Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET WWF of 5 1 Gal Xtreme Blue -20 Windshield Washer Fluid. 121 Landmark Drive Greensboro, NC 27409

COMPOSITION / INFORMATION ON INGREDIENTS

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

5375 RED LOW VOC ACETONE ACRYLIC TRAFFIC MARKING PAINT

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

PALMOLIVE ULTRA SPRING SENSATION LAVENDER

22 APR 2010 <MSDS_ID>300088</MSDS_ID> MATERIAL SAFETY DATA SHEET. <Product> PHENOLPHTHALEIN INDICATOR SOLUTION # HR </Product> Part#: N/A

Identification of Arson Accelerants by Gas Chromatography

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Material Safety Data Sheet

Material Safety Data Sheet Wix Diesel Fuel Additive

Material Safety Data Sheet

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

FABULOSO MULTI SPRAY ALL PURPOSE CLEANER LIQUID LAVENDER

PAPER CHROMATOGRAPHY

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Material Safety Data Sheet

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Calculations and OELs

MATERIAL SAFETY DATA SHEET

QUIK-CARE AEROSOL FOAM HAND SANITIZER. Use only for the purpose on the product label.

Purification of reaction mixtures using flash chromatography.

Material Safety Data Sheet

DOW CORNING CORPORATION Material Safety Data Sheet

The photoionization detector (PID) utilizes ultraviolet

CeramClean II Aluminum Safe

SECTION 1 - PRODUCT IDENTIFICATION

How To Test For Contamination In Large Volume Water

Fractional Distillation and Gas Chromatography

Exposure and Control of Ten High Priority MSHA Contaminants in Metal Mines. Presented by: Shannon E. Newton, MPH, CIH

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

MATERIAL SAFETY DATA SHEET

DOW CORNING CORPORATION Material Safety Data Sheet

23 The Thermal Conductivity Detector

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

105 Adopted:

Material Safety Data Sheet Isopropyl Alcohol, 50. Section 1 - Chemical Product and Company Identification

Expectations for GC-MS Lab

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

Material Safety Data Sheet

Material Safety Data Sheet

SAFETY DATA SHEET INSTANT HAND SANITIZER GEL / SANTI-GEL

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

CHROMOCTANE O N LINE ANALYZER

Material Safety Data Sheet

Power Blast (CCA) Safety Data Sheet (SDS)

A Report of Air Sampling for Mercury Vapor and Particulates During Fluorescent Tubes Disposal Operation Maywood, Illinois Survey date: 9/28/2000

MATERIAL SAFETY DATA SHEET High Pressure Laminate Fire Retardant

MATERIAL SAFETY DATA SHEET NAME OF PRODUCT MSDS DATE: 04/01/11

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

SAFETY DATA SHEET (SDS)

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION ACKNOWLEDGEMENT ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS LIST OF APPENDICES

Material Safety Data Sheet

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

SUCRALOSE. White to off-white, practically odourless crystalline powder

Fila Chemicals USA FILA CR CHEMTREC

MATERIAL SAFETY DATA SHEET

Quebec Quebec Tel : Fax : MSDS: P10 (10% Methane in Argon) PRODUCT INFORMATION

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

GAS CHROMATOGRAPHY. DETERMINING THE PERCENT COMPOSITION OF A MIXTURE OF VOLATILE LIQUIDS USING A GAS CHROMATOGRAPH. (Revised: )

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

MATERIAL SAFETY DATA SHEET

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

CORESTA RECOMMENDED METHOD Nº 81

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

The Official NAPAonline.com E-commerce Site Shop NAPAonline

ß-CYCLODEXTRIN SYNONYMS

3M MATERIAL SAFETY DATA SHEET 3M(TM) Spray-Mount(TM) Artist's Adhesive (Catalog No or 6065) 11/30/2004

MATERIAL SAFETY DATA SHEET MSDS No.: 007

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

MURPHY OIL SOAP LIQUID - ORIGINAL

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Transcription:

Validation of Isopropyl Alcohol Using SKC Passive Sampler Cat. No. 575-002 Page 1 of 10 Publication 1839 Issue 1407

Research Report Validation of Isopropyl Alcohol Using the SKC Cat. No. 575-002 Passive Sampler Abstract A sampling method using the Passive Sampler for Organic Vapor (Cat. No. 575-002) has been validated for sampling isopropyl alcohol in workplace air. A desorption efficiency (DE) study was conducted at 0.05, 0.10, 0.50, 1, and 2 times 100 ppm for an 8-hour period. The average DE was 103.5% with a relative standard deviation (RSD) of 4.0%. The sampling rate was determined for samplers exposed to isopropyl alcohol levels of 100 ppm at 80% relative humidity (RH) and 25º C. The mean sampling rate for 27 tests was 18.42 ml/min with an RSD of 4.6%. Samplers can be stored at ambient temperatures or in a freezer (-22º C) up to 3 weeks with less than a 5% loss in recovery. The Cat. No. 575-002 sampler was desorbed in 2 ml of 10% 2-butanol in carbon disulfide and analyzed by gas chromatography with flame ionization detection (FID). Authors Nicole Zovack Cynthia Kuhlman Linda Coyne Validation Date: April/May 2012 Page 2 of 10 Publication 1839 Issue 1407

Introduction Isopropyl alcohol, also known as isopropanol and 2-propanol, is a flammable liquid with an odor resembling that of a mixture of ethanol and acetone (1). Potential symptoms of overexposure are irritation of eyes, nose, and throat; drowsiness, dizziness and headache; and dry cracking skin. It is used in antifreeze compositions, quick drying inks, and hand lotions as well as in the manufacturing of acetone and as a solvent for gums. Isopropyl alcohol is also used as an antiseptic (1). It has an OSHA and NIOSH guideline of 400 ppm and an ACGIH guideline of 200 ppm based on an 8-hour TWA. The purpose of this study is to validate the Cat. No. 575-002 diffusive samplers for monitoring isopropyl alcohol at 100 ppm. Critical parameters include analytical recovery, sampling rate, and storage. Experimental The desorption efficiency for the samplers was conducted by injecting a known amount of isopropyl alcohol into the back of each sampler. The samplers were capped and allowed to equilibrate overnight and then analyzed the next day to determine the analytical recovery. The tests were conducted at mass loadings equivalent to an 8-hour TWA sample based on a calculated sampling rate (17.8 ml/min) at 0.05, 0.10, 0.50, 1, and 2 x PEL under dry conditions. Isopropyl alcohol (Aldrich, St. Louis, MO, U.S.) was used to prepare concentrations in the test rig. A dynamic atmosphere was generated using a syringe pump and filtered air streams to generate the concentration. The system is shown in Figure 1. The atmosphere was fed into an exposure chamber. The diffusive samplers were exposed on a rotating bracket inside the chamber to simulate wind velocity. The sampling rate was conducted at 100 ppm for periods from 15 minutes to 8 hours at 80% RH and 25º C. The concentration within the atmospheric chamber was verified with SKC Cat. No. 226-01 sorbent tubes (SKC Inc., Eighty Four, PA U.S.) to be 90.3 ppm. The Cat. No. 575-002 diffusive samplers (SKC Inc., Eighty Four, PA U.S.) were used for the study. After exposure, samplers were sealed until analysis. The storage study consisted of injecting 21 samplers with known amounts of isopropyl alcohol. The samplers were capped and allowed to equilibrate overnight. Three samplers were analyzed the next day while 9 samplers were stored at ambient temperatures and the remaining 9 samplers were stored in a freezer (-22º C). Three samplers were analyzed each week for 3 weeks from both temperatures to determine the analytical recovery. All diffusive samplers were desorbed in 2 ml of 10% 2-butanol in carbon disulfide and shaken on a flatbed shaker for 15 minutes. The extracts were then analyzed by flame ionization detection gas chromatography. A chromatogram is shown in Figure 2. SKC constantly reviews this data and conducts experiments to provide the most precise sampling rate. The rate published in these validation reports is the correct rate. Results and Discussion The desorption efficiency results for isopropyl alcohol with the diffusive samplers are shown in Table 1. The mean recovery of the diffusive samplers was 103.5% (RSD 4.0%). The sampling rate data is shown in Table 2. The results of the 27 samplers show that isopropyl alcohol can be sampled with the Cat. No. 575-002 diffusive samplers at an average sampling rate of 18.42 ml/min (RSD 4.6%). The data indicates that the sampler can collect a 15-minute to 8-hour sample at 100 ppm isopropyl alcohol. The 3 week storage study, shown in Table 3 and Table 4, suggests that the samplers are able to be stored at either freezer (-22º C) or ambient temperatures for 3 weeks with less than a 5% loss in recovery. Page 3 of 10 Publication 1839 Issue 1407

Conclusion Cat. No. 575-002 diffusive samplers have been partially validated for sampling isopropyl alcohol with a DE of 103.5% (RSD 4.0%) and a sampling rate of 18.42 ml/min (RSD 4.6%). The samplers showed good stability when stored for 3 weeks at ambient and freezer (-22º C) temperatures. The Cat. No. 575-002 diffusive samplers can be used for measuring exposures to isopropyl alcohol from 15 minutes to 8 hours. References 1. Merck Index, 13 th Edition, p. 932. Page 4 of 10 Publication 1839 Issue 1407

Table 1. Desorption Efficiency Isopropyl Alcohol PEL Spike (μg) Recovered (μg) Recovery (%) 0.05 109.51 108.90 99.4 109.37 99.9 107.53 98.2 115.61 105.6 0.10 215.76 222.48 103.1 220.18 102.0 211.13 97.9 217.97 101.0 0.50 1146.52 1195.71 104.3 1221.99 106.6 1114.02 97.2 1133.46 98.9 1.00 2130.23 2273.79 106.7 2267.43 106.4 2324.05 109.1 2306.55 104.7 2197.76 99.8 2393.31 108.6 2339.63 106.2 2.00 4296.78 4720.89 109.9 4654.94 108.3 Mean 103.5% Std. Dev. 0.041 RSD 4.0% Page 5 of 10 Publication 1839 Issue 1407

Table 2. Sampling Rate 100 ppm Isopropyl Alcohol, 80% RH and 25º C Time (hr) Sampling Time (ml/min) 0.25 18.39 0.25 18.74 0.25 18.97 0.50 18.34 0.50 18.42 0.50 19.32 0.50 18.12 1.00 18.48 1.00 18.56 1.00 19.97 1.00 18.65 2.00 18.99 2.00 19.76 2.00 19.65 2.00 19.70 4.00 17.84 4.00 17.49 4.00 18.44 4.00 18.89 4.00 18.44 4.00 17.90 4.00 16.78 4.00 17.45 8.00 17.10 8.00 17.94 8.00 17.15 8.00 17.74 Mean 18.42 ml/min Std. Dev. 0.842 RSD 4.6% Page 6 of 10 Publication 1839 Issue 1407

Table 3. Storage Study Isopropyl Alcohol, Ambient Temperatures Week Recovery (%) 1 101 2 97 3 105 Table 4. Storage Study Isopropyl Alcohol, Freezer Temperatures Week Recovery (%) 1 103 2 99 3 102 Page 7 of 10 Publication 1839 Issue 1407

Page 8 of 10 Publication 1839 Issue 1407

Appendix A Atmosphere Generation Apparatus The instrument is designed to expose a known concentration of a chemical hazard to a passive sampler under controlled conditions of: 1. Concentration, 2. Temperature, 3. Humidity, 4. Wind Velocity Effect, and 5. Time. The instrument consists of: Description 1. An exposure chamber in which the wind velocity effects are controlled by internal rotating holders. 2. An air supply and purification train such that dry air is blended with saturated air under desired temperature conditions so as to provide air at a known flow and selectable humidity. 3. An injection system composed of a precision motor driven syringe in which the chemical hazard can be injected into the flow system and the temperature of the injector is closely controlled. 4. An electrical control system that controls the entire instrument operation. 5. The chamber concentration can be verified by either solid sorbent sampling tubes actively sampled or by gas analysis of the gas phase. The particular verification method used will depend on the analyte of interest. Means are also included to check the relative humidity. Page 9 of 10 Publication 1839 Issue 1407

Figure 2. Sample Chromatogram Isopropyl Alcohol Column: RTX-5 30 m x 0.32 mm ID x 1.0 µm film Temperatures Column: 50 C, isothermal, hold for 3.5 minutes Injector: 250 C Detector: FID at 250 C Retention Times Isopropyl alcohol: 1.74 minutes 2-Butanol: 2.03 minutes Carbon disulfide (CS 2 ): 2.57 minutes Page 10 of 10 Publication 1839 Issue 1407