www.lascarelectronics.com



Similar documents
EL-USB mA Current Loop USB Data Logger

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500 Series Low-Cost Data Loggers and Accessories

Data Logging Solutions from Lascar Electronics

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

USER S GUIDE Humidity and Temperature USB Datalogger

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit

Temperature Datalogger Users Manual

Data Loggers for Real Time Temperature Monitoring - WiFi

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

SupcoLog Logger Interface Software

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

Datalogger Graph Software Help

Wireless Data Logger Monitoring Systems

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

FT-1000/GPS-N. System of remote monitoring and control of physical

User Guide. Temperature and Humidity Datalogger. Model 42280

User Manual. Humidity-Temperature Chart Recorder. Model RH520

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

4-Channel Thermometer / Datalogger

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

SMS GSM Alarm Messenger

GSM HOME SECURITY SYSTEM

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

1. SAFETY INFORMATION

DataView DVTH Data Logger for Temperature and Humidity

New thermometers and accessories to grow your business

SOLAR I-V Rel /07/10

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

Model UT713 OPERATING MANUAL

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

SpO2 PULSE OXYMETER MD-300

Nardalert S3 Non-Ionizing Radiation Monitor

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

Table of Contents Appendix 4-9

USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright Pico Technology Limited. All rights reserved.

Preparing Log-ic 360 USB Loggers for Use

USER MANUAL V5.0 ST100

WD-AMX Water Detection Controllers

User Guide Reflow Toaster Oven Controller

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Long Distance Industrial Wireless Transmitters and Receivers

User's Guide. Integrating Sound Level Datalogger. Model Introduction

SNMP Web Management. User s Manual For SNMP Web Card/Box

RS DIGITAL THERMOMETER

K-Type Thermocouple Sensor User s Guide

is then retained absolutely without interruption.

BLE113 DEVELOPMENT KIT

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

NEW. EVEN MORE data acquisition and test stand automation

BadgeRAE. User Manual. PGM-1010 CO Detector PGM-1020 H 2. S Detector

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

IO-DIM6 6-Channel, Digital to Analogue Converters

Temperature & Humidity SMS Alert Controller

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

SHENZHEN JUNSI ELECTRONIC CO.,LTD

CO2 Alarm. Operation. Application

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Model UT33A: OPERATING MANUAL Table of Contents (1)

SoundLAB Software Download Software from the Bogen website:

Manual. CANcaseXL CANcaseXL log. Version 5.1 English

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Fingerprint Time Attendance Access System with Data Recording

SA-9600 Surface Area Software Manual

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

Changers Kalhuohfummi User Manual

Estação Meteorológica sem fio VEC-STA-003

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

USB Edition TM-STD30 User Guide

Model UT201/202: OPERATING MANUAL. Table of Contents

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

A-Series Data Loggers PRODUCT MANUAL

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Wahl C50 Calibrator FEATURES

1000 Series Data Loggers PRODUCT MANUAL

USB Smart Power Sensor

PROXIMITY CARD READERS C-10, C-20, C60, C70

Fluke 3000 FC Series Test Tools Technical Data

Instruction Manual Service Program ULTRA-PROG-IR

User Manual for CH-PFC76810

Dual Laser InfraRed (IR) Thermometer

GSM/3G UMTS/GPS/SMS Data Logger. The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA

Transcription:

FEATURES 0-30V d.c. measurement range Logging rates between 1s and 12hr Stores readings Connection via two screw terminals USB interface for set-up and data download User-programmable alarm thresholds Status indication via red and green LEDs Supplied with replaceable internal lithium battery and Windows control software ORDERING INFORMATION Standard Data Logger (Data Logger, Software on CD, Battery) Replacement Battery EL-USB-3 BAT 3V6 1/2AA This standalone data logger measures and stores up to voltage readings over a 0-30V d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the data logger into a PC s USB port and running the purpose designed software under Windows 2000, XP and Vista (32-bit). The data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a long-life lithium battery. Correct functioning of the unit is indicated by ashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a set of measurement leads terminating in crocodile clips. Speci cations Minimum Typical Maximum Unit 0-30V d.c. measurement range 0 30 V d.c. Internal resolution 50 mv d.c. Accuracy (overall error) ±1 % Logging rate every 1 s every 12 hr - Operating temperature range -35 (-31) +80 (+176) C ( F) 1/2AA 3.6V Lithium Battery Life 1* Year * depending on ambient temperature, logging rate and use of alarm LED. EL-WIN-USB (CONTROL SOFTWARE) Lascar s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows 2000, XP (Home and Professional Editions) & Vista (32-bit). The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be con gured: Logger name Logging rate (1s, 10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Start date and start time The latest version of the control software may be downloaded free of charge from Speci cations liable to change without prior warning Issue 8 10/09 S.C Applies to EL-USB-3/1 Page 1 of 5

LED FLASHING MODES EL-USB-3 features a red and a green LED. By default hold is disabled. In this mode the red LED will no longer continue to ash after the logged reading has returned to normal from an alarm condition. Hold can be turned on via the control software. In this mode the red LED that indicates an alarm condition will continue to ash, even after the logged reading has returned to normal. This feature ensures that the user is noti ed that an alarm level has been exceeded, without the need to download the data from the logger. Green single ash (10 seconds) The data logger is currently logging. No alarm. Green single ash (20 seconds) The data logger is currently logging. No alarm. However, the battery is low and should be replaced before Green single ash (30 seconds) The data logger is not currently logging, but is primed to start at a later date and time (delayed start). Green double ash (20 seconds) The data logger is full and has stopped logging. No alarm. Red single ash (10 seconds) The data logger is currently logging. Low alarm. Red single ash (20 seconds) The data logger is currently logging. Low alarm. However, the battery is low and should be replaced before Green LED Red LED Red double ash (10 seconds) The data logger is currently logging. High alarm. Red double ash (20 seconds) The data logger is currently logging. High alarm. However, the battery is low and should be replaced before Red/Green single ash (20 seconds) The data logger is full and has stopped logging. Alarm (high, low or both). No LEDs ash The data logger is stopped, the battery is empty or there is no battery tted. Speci cations liable to change without prior warning Issue 8 10/09 S.C Applies to EL-USB-3/1 Page 2 of 5

DIMENSIONS All dimensions in mm (inches) 26.8 (1.05) 26.8 (1.05) 98.0 (3.86) CONNECTION AND APPLICATIONS +ve supply to sensor Signal out Sensor -ve/gnd supply to sensor Battery + _ + _ Logging a sensor voltage Logging a battery voltage Speci cations liable to change without prior warning Issue 8 10/09 S.C Applies to EL-USB-3/1 Page 3 of 5

BATTERY REPLACEMENT We recommend that you replace the battery every 12 months, or prior to logging critical data. The EL-USB-3 does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to PC. Only use 3.6V 1/2AA lithum batteries. Check with your supplier that the battery you are ordering is press t and is not tted with solder tags. Before replacing the battery, remove the EL-USB-3 from the PC. Note: Leaving the EL-USB-3 plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. Speci cations liable to change without prior warning Issue 8 10/09 S.C Applies to EL-USB-3/1 Page 4 of 5

THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-usb connection and easy-to-use functionality that the range is known for. The range comprises 14 data loggers as detailed in the following table: Part No Function Range Accuracy (overall error) Typ. Max. Readings Battery Battery Life* EL-USB-1 Temperature EL-USB-1-PRO High temperature -40 to +125 C (-40 to +257 F) ±0.2ºC (±0.4ºF) 3.6V AA 3 years EL-USB-2 Temperature, humidity & dew point ±2ºC (±4ºF) ±3%RH ±6.0%RH EL-USB-2+ Increased accuracy temperature, humidity & dew point ±0.3ºC (±0.6ºF) ±2.0%RH ±4.0%RH EL-USB-2-LCD Temperature, humidity & dew point with LCD ±3.0%RH ±2ºC (±4ºF) ±6.0%RH EL-USB-2-LCD+ Increased accuracy temperature, humidity & dew point with LCD ±0.3ºC (±0.6ºF) ±2.0%RH ±4.0%RH EL-USB-3 Voltage 0 to 30V d.c. ±1% EL-USB-4 Current loop 4 to 20mA ±1% EL-USB-TC Thermocouple (J, K and T-type) K-type probe included -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) 6 months -200 to +390ºC (-328 to +734ºF) (T-type) EL-USB-TC-LCD Thermocouple with LCD (J, K and T-type) K-type probe included -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) 6 months -200 to +390ºC (-328 to +734ºF) (T-type) EL-USB-CO Carbon monoxide 0 to 1000ppm NOT A LIFE SAVING DEVICE ±6ppm 3 months EL-USB-CO300 Carbon monoxide 0 to 300ppm NOT A LIFE SAVING DEVICE ±4ppm 3 months EL-USB-LITE Low cost temperature -10 C to +50 C (+14 to +122 F) 4,080 CR1620 Lithium coin cell 1 month EL-USB-RT Real-time temperature & humidity monitor -20 to +70 C (-4 to +158 F) ±4.5%RH 7 days N/A N/A *Depending on logging rate, ambient temperature, and use of alarm LED Module House Whiteparish, Salisbury Wiltshire SP5 2SJ UK T +44 (1794) 884567 F +44 (1794) 884616 E sales@lascar.co.uk 4258 West 12th Street Erie PA 16505 USA T +1 (814) 835 0621 F +1 (814) 838 8141 E us-sales@lascarelectronics.com UNIT NOS. 6-8, 19/F Futura Plaza 111-113 How Ming Street Kwun Tong, Kowloon HONG KONG T +852 2389 6502 F +852 2389 6535 E saleshk@lascar.com.hk Speci cations liable to change without prior warning Issue 8 10/09 S.C Applies to EL-USB-3/1 Page 5 of 5