Automation in Biomethanation Plant Using PLC and SCADA

Similar documents
Biogas as transportation fuel

Introduction to Waste Treatment Technologies. Contents. Household waste

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

Bio-CNG plant. Spectrum Renewable Energy Limited, Kodoli, Kolhapur

Energy from digester gas. Optimised biogas utilisation

Process Technology. Advanced bioethanol production and renewable energy generation from ligno-cellulosic materials, biomass waste and residues

Subject: Life Science- Advanced Biology 2 Standard: Cellular Processes

PLC Based Liquid Filling and Mixing

EVALUATION OF BIOGAS PRODUCTION POTENTIAL FROM ELEPHANT DUNG

Carbon Footprint of CMC Hospital for 2013

Energy and Carbon Management

A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems

ANEROBIC DIGESTION and BIOGAS

Automated Bottle Filling System

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Recent Technologies in Nuclear Power Plant Supervisory and Control Systems

Lesson 6. BioMara gratefully acknowledges the following funders: Content Section - How Algae can be used to produce Biofuel.

HC900 for Boiler Control Applications

City of Dallas 1.5 MGD WWTP

Anaerobic Digestion: Biology and Benefits

Control of Boiler Operation using PLC SCADA

Biomass Renewable Energy from Plants and Animals

Sustainable production of biogas and bioethanol from waste

CLEANING IN PLACE AUTOMATION FOR PROCESS INDUSTRY USING PLC AND SCADA SOFTWARE

Green Gases Practical concepts for reliable sustainable energy supply

Digital Systems Based on Principles and Applications of Electrical Engineering/Rizzoni (McGraw Hill

Design and Research of Control System of the Large-Scale Accumulator Blow Molding Machine Based on PLC

Florida Department of Education Student Performance Standards

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

Papapostolou 1, E. Kondili 1, J.K. Kaldellis 2

CNG Fueling Developments and Renewable Conversion to RNG Technology and Update on a RNG Fleet

Bioremediation of Petroleum Contamination. Augustine Ifelebuegu GE413

MC4-50 Feeding System

Indonesia Biogas Asia Pacific Forum Developing A Biogas Hub In Commercialising Biogas For Asia. Opportunities for Biogas as a Vehicular Fuel

Murcia. Capital and most populous city of the Region de Murcia. Seventh largest city in Spain.

Automatic Ration Material Distributions and Payment System Based on GSM and RFID Technology

HEINRICH FRINGS INFORMATION

Real Time Water Quality Monitoring System

SHORT TRAINING COURSES

How To Model Biomass

Which of the following can be determined based on this model? The atmosphere is the only reservoir on Earth that can store carbon in any form. A.

EnviTec Biogas Energy from Agricultural and Agro-Industrial Wastes. Eng. Marcello Barbato Sales Manager

Topic 3: Nutrition, Photosynthesis, and Respiration

O 2. What is anaerobic digestion?

BIOMASS: BIOGAS GENERATOR. Curriculum: Biomass Power (organic chemistry, chemical/carbon cycles, plants, energy resources/transformations)

Biogas - Trends in Germany Biogas as a key in future energy systems

Sewage and Wastewater Odor Control Dr. Giancarlo Riva, Ozono Elettronica Internazionale, Muggio, Italy

INTERIM TECHNICAL REPORT FIRST 18 MONTH PERFORMANCE SUMMARY FOR ANAEROBIC DIGESTION OF DAIRY COW SLURRY AT AFBI HILLSBOROUGH

CLEANING IN PLACE IN PHARMACEUTICAL INDUSTRY USING PLC AND SCADA SOFTWARE

GUIDELINES FOR LEACHATE CONTROL

Municipal Solid Waste Used as Bioethanol Sources and its Related Environmental Impacts

The City of Boulder 75 th Street Wastewater Treatment Facility

Cellular Respiration: Practice Questions #1

ANAEROBIC/ANOXIC TANKS

Provided below is a description of the processes generating wastewater in a poultry plant and a typical pretreatment and full treatment system.

CAT CG132. Series Gas Generator Sets

PROGRAMMABLE LOGIC CONTROL

Biogas upgrading using the DMT TS-PWS Technology.

Implementing a Reliable Furnace Monitoring System

PROPAK AquaBio Complete Water Restoration Systems

Introduction To SCADA and Telemetry

IGW S.r.l. Sofia 9 giugno 2015 PIÙ MODERNI, PIÙ COMPETITIVI, PIÙ FORTI AMBIENTE ED EFFICIENZA ENERGETICA IN BULGARIA. Organizzazione a cura di

Electronic Diesel Control EDC 16

Monitoring and Controlling System Based on Configuration Software of Microwave Vacuum Drying Machine

ngenieros Ingenieros Asociados De Control S.L.

1-Some related indicators: Total land area is 1 million Km 2. Only 3% of the land area is arable. The rest 97% is hyper arid desert. The whole lands a

CLEAN DEVELOPMENT MECHANISM CDM-MP62-A01

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

Wireless Communications for SCADA Systems Utilizing Mobile Nodes

NAWARO BioEnergie AG: a short introduction into our business for BiG>East: Biogas for Eastern Europe

Poultry manure as a substrate for methane fermentation: problems and solutions

Cooking at the Speed of light!

Web SCADA Employing Application Program Interface as Data Source

LANDFILL GAS TO ENERGY- COMBINED ENGINE AND ORC-PROCESS

Consultation response: PPC Technical Guidance Note 35 Anaerobic Digestion

COST EFFECTIVE AND EFFICIENT INDUSTRIAL TANK CLEANING PROCESS

1 nrsapre@gmail.com, 2 dr.s.m.kumar@gmail.com

INTRODUCTION. Fact Sheet: Air Pollution Emission Control Devices for Stationary Sources

CASE STUDY HIGHLIGHTING THE BENEFITS OF MONITORING AND CONTROL FOR IMPROVING THE PERFORMANCE OF AN ANAEROBIC DIGESTION PLANT

Mixing Valves. ARGUS Application Note: Mixing Valves

Biogas plants with decentralized bioenergy centres

Solar Powered Smart Irrigation System

DEVELOPMENT OF E-PUBLIC DISTRIBUTION SYSTEM (E-PDS) USING SMART CARD

EMERGENCY VAPOR SCRUBBER SYSTEMS

Get Ready For The One Tonne Action Challenge!

FEED-IN TARIFF (FiT) IN MALAYSIA

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

an overview of trends and approaches

Electricity: biogas may be used to generate electricity using a gas electric generator set or natural gas boiler system. Electricity may either be

CURRICULUM VITAE: BURAK DEMIREL

Biogas and landfill gas utilization in Helsinki region waste management. Aino Kainulainen Project Manager Helsinki Region Environmental Services HSY

CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER

SAMPLE CHAPTERS UNESCO EOLSS DIGITAL INSTRUMENTS. García J. and García D.F. University of Oviedo, Spain

11. FLOWCHART BASED DESIGN

Respiration Worksheet. Respiration is the controlled release of energy from food. Types of Respiration. Aerobic Respiration

Raptor Septage Acceptance Plant. For Municipal Wastewater, Septage and Grease Trap Applications

Electrical Symbols and Line Diagrams

Energy from waste. Introduction. Legal status of this guideline. What is energy from waste? Draft guideline

GSM based Remote Sensing and Control of an Irrigation System using WSN: a Survey

Transcription:

, pp.171-180 http://dx.doi.org/10.14257/ijbsbt.2016.8.2.16 Automation in Biomethanation Plant Using PLC and SCADA D. Ajay abilash 1, P. Kayalvizhi 2, R. Rakesh 3, S. Balamurugan 4 Department of mechanical engineering, Periyar Maniammai University, Thanjavur-613403 Tamilnadu, India. mechajay.k@gmail.com 1, kayal.electrocom@gmail.com 2, rak2win@gmail.com 3, balasathriyan.tje@gmail.com 4. Abstract Biomethanation is a feasible method to generate the biogas from organic waste like food waste, human waste, night soil waste, cow dung etc. The night soil waste and animal waste has bad odor in nature and it produces some infection to operators, so we implement the automation in biomethanation plant. This plant has four major processes like waste collection and mixing, digestion, gas collection and gas distribution. These above processes are controlled by manually, hence it produces some problems and errors, to overcome this problem, and we proposed an automatic control system for biomethanation plant. In this system the overall process are controlled by programmable logic controller and field instruments. And also these processes are controlled and monitored by SCADA using wonderware intouch software. Keywords: Biomethanation, biogas, automation, programmable logic controller, SCADA 1. Introduction Biomethanation is the conversion of organic matter in waste products into methane by the action of microbes in the absence of air is known as anaerobic digestion. Anaerobic digestion is a process in which microorganism decays the biodegradable materials without the presence of oxygen. By this process, bioenergy can be produced from the organic wastes and can be used for Industries, household purposes as an alternate. Most of the fermentation process happens in Industries for food and drink products and home fermentation uses anaerobic digestion [1]. This process of digestion starts with bacterial hydrolysis of input substances. Inorganic soluble polymers such as carbohydrates are decomposed into soluble matters which are accessible by other bacteria. Sugars and amino acids are transformed into carbon dioxide, hydrogen, ammonia, and organic acids by Acidogenic bacteria. This bacterium converts the resulting organic acids into acetic acid with addition of ammonia, hydrogen, and carbon dioxide. Finally, the products are transformed into methane and carbon dioxide by methanogens. In anaerobic waste treatments, a major role play by the methanogenic arched populations [2]. It is used as part in the process of treatment of biodegradable waste and sewage sludge. Anaerobic digestion lowers the landfill gas emission to the atmosphere. Anaerobic digestion acts as the part of integrated waste management system and used as the source of renewable energy. These digesters also fed with energy crops such as maize. This process produces biogas consist of methane, carbon dioxide and some other contaminated gases [3]. This biogas can be used as fuel in all gas engines. Biogas production is one of the most economic ways from organic waste. ISSN: 2233-7849 IJBSBT Copyright c 2016 SERSC

2. Existing System Description 2.1. Process Flow Diagram for Existing System Biomethanation has five main units. They are mixing unit, digestion unit, recirculation unit, scrubbing unit, finally storage unit. In these five units, different types of process take place. In mixing unit all types of feed like cow dung, food waste and human waste are mixed manually by using water and then mixed feed send to digester by using valve. It s a manually controlled valve. Digester is a concrete bed plate placed on the ground level. It is a fully closed unit. After mixing the feed, it transferred from mixing tank into digester [4]. The digester is a continuously working reactor in which fermentation feed is mixed finely to create a fully homogeneous medium. The mixing process in digester is achieved by recirculation unit. It has one pump which is used to re circulate water throughout the digester. This process is used to increase the biogas production in a short period of time. After this, gas will produce in the digester then it will transfer to gas storage bag. The produced gas has some impurities for that we have to remove the impurities by using scrubber unit; it is used to separate the biogas into methane, after removal of unwanted gas the biogas stored into storage bag [5]. These are the process takes place in the biomethanation plant, are controlled by manually. 3. Problem Description The existing biomethanation plant was fully controlled by manual operation. In this process some difficulties occurs like the waste gives some bad odor so we can t do by manual in feeding and mixing and another difficulty lies in gas flow and gas level monitoring. During manual operation we can t analyze how much of gas produced in particular time period in biomethanation plant. For the above reasons we change the manual operation into automatic operation. 172 Copyright c 2016 SERSC

4. Proposed System Description 4.1. Process Flow Diagram for Proposed System In proposed system, all process is controlled by automatic. It has six units. They are pre treatment unit, mixing unit, digestion unit, recirculation unit, scrubbing unit and storage unit. Pretreatment unit is used to remove the non biodegradable materials that are not affected by digestion and take up unnecessary space and it providing a uniform small particular size feed stock for efficient digestion [6]. After the pre treatment process the feed transfer from pre treatment tank into mixing tank. In mixing tank all types of feed mixed together by using agitators which is actuated by electric motor. After preset timing, the agitator gets off and the feed stock will transfer from mixing tank to digester through screw conveyor. If feed reaches low level, the screw conveyor will cut off. After that the recirculation pump will get on. Water will circulate inside of the digester. It is used to improve the contact between the micro organisms and feed. It also prevents the formation of scum and the development of temperature gradients within the digester. After that gas production will get starts. If gas reaches preset pressure, the pressure switch give input to plc then the blower gets on and the biogas transfer from digester to storage bag by using blower because biogas has not the flowing capability. Before this process, biogas will pass through the scrubber which is used to remove CO 2, H 2 S, and moisture and then methane gas is stored in the storage bag. It has one flow meter which is used to measure the gas flow of biogas and we calculate the biogas consumption. In manual operation it is not possible. These operations and process are controlled by using programmable logic controller, field instruments like sensors, valve, motor etc. Copyright c 2016 SERSC 173

4.2. Hardware Description A. Block Diagram of System START STOP Emergency stop Level sensor Flow sensor Pressure switch PLC Pre treatment tank1, valve 1 Pre treatment tank2, valve 2 Agitator motor Screw conveyor motor Recirculation pump Blower motor B. Block Diagram Description The system consists of two pretreatment tank valve, agitator motor, level sensor, screw conveyor motor, recirculation pump motor, pressure switch, flow sensor, blower motor, scrubber motor, PLC. Pre treatment valve is used to transfer feed from pretreatment tank to mixing tank. Agitator motor is used to mixing the feed properly. Level sensor is used to check the level of mixing tank. Screw conveyor is used to transfer the feed from mixing tank to digester. Recirculation pump is used to circulate the water throughout the digester. Pressure switch is used to measure gas level in digester. If the gas pressure reaches the present value then it will actuate the blower to transfer the gas from digester to storage tank. Flow sensor is used to measure the gas flow of biogas and it also measure the consumption gas. Scrubber motor is used to re circulate the water from raw water tank into scrubber. It will separate the biogas into methane. C. Programmable Logic Controller It is an industrial computer which accepts input signals from field instruments like start/stop push button level sensor, flow sensor pressure switch and it controls the output instruments like valves, motors, pumps etc [7]. 4.3. Software Description Programmable logic controller (or) PLC is an intelligent system which was introduced in the automation and control industry for replacing relay logic because relay has lots of drawbacks. Nowadays better I/O handling capabilities and more programming elements has been added along with good improvement in communications. In this proposed system, we used Rexroth Bosch PLC, software is indralogic. The Indralogic L20 of Rexroth is a compact plc used designed for logic operation and control inputs and outputs. It is the 16 bit processor with 16 inputs and 16 outputs in digital, 2 inputs and 2 outputs in analog [8]. A. SCADA 174 Copyright c 2016 SERSC

SCADA (supervisory control and data acquisition) is a unify monitoring system used to control a complete system in industries such as thermal power plant, glass production plant, nuclear power plant. SCADA system collects the information from plant and transfers the information to plant and display the information using HMI [9]. This system is very simple to operate and easy to monitor and supervise the plant. In this system WONDERWARE INTOUCH HMI software are used to control and monitor the plant because, it is user friendly, easy to handle, simple to make a graphics, easy to configure the system and easily interface to any system. The SCADA design for automated biomethanation plant is shown in fig.1. It is mainly used to monitor and control the overall process. This system monitors some parameters like gas flow, gas pressure, tank level, and valve position. And also it controls the overall system like start/stop by local and remote. Figure 1. SCADA Graphics for Biomethanation Plant 5. Working of Proposed System 5.1. Sequence of Operation The following steps are working algorithm of automated biomethanation plant: 1. Press the start push button to start the process. 2. Pretreatment tank solenoid valve1 and solenoid valve2 gets open (waste material transfer from pretreatment tank to mixing tank) 3. If top level sensor in mixing tank (agitator) detects the waste material, then solenoid valve1 and solenoid valve2 will cut off. 4. Simultaneously agitator motor gets on (to mix and grind the solid waste and liquid waste). 5. After some preset time the agitator motor will cut off. 6. Simultaneously screw conveyor motor gets on (to transfer the waste material from agitator to digester). 7. If both top level and bottom level sensor in mixing tank de senses. Then screw conveyor will cut off. 8. Simultaneously recirculation pump gets on ( to mix the waste materials in digester for improve digestion) Copyright c 2016 SERSC 175

9. After some preset time the recirculation pump will cut off. 10. If pressure reaches the set point in digester, then the blower gets on. 11. Simultaneously scrubber motor gets on. 12. After some preset time the blower motor and scrubber motor will cut off. 13. After these steps the process will repeat when the stop push button is pressed. 5.2. Flow Chart for Proposed System 176 Copyright c 2016 SERSC

Copyright c 2016 SERSC 177

5.3. PLC Program for Proposed System 178 Copyright c 2016 SERSC

6. Advantages of Proposed System It can reduce the process time. It is used to reduce the man power It is used to collect the data from plant It can avoid the human errors It gives good reliability. 7. Conclusion This paper involves three stages (i) study the existing system of Biomethanation plant, (ii) Identifying problem in existing system, (iii) Finally give the new proposal for automation of this plant. The proposed system is an automated Biomethanation plant, which can perform operations like mixing, transferring feed into digester chamber, re-circulating water in digester for mixing and collect the data from digester like pressure and flow of gas etc. These all operations are achieved by using programmable logic controller and field instruments. References [1] E. V. Prakash, L. P. Singh, Biomethanation of vegetable and fruit waste in co-digestion, International Journal of Emerging Technology and Advanced Engineering, Certified Journal, vol. 3, no. 6, (2013). [2] S. Chelliapan, S. B.Mahat, Anaerobic Digestion of Paper Mill Wastewater, Iranica Journal of Energy & Environment 3 (Special Issue on Environmental Technology):pp.85-90, ISSN 2079-2115, (2012). [3] https://en.wikipedia.org/wiki/anaerobic_digestion. [4] R.S. Khoiyangbam, Environmental Implications of Biomethanation in Conventional Biogas Plants, Iranica Journal of Energy & Environment 2 (2): pp.181-187, ISSN 2079-2115, (2011). [5] A.N. Sarkar, Research and development work in biogas Technology, Journal of Scientific and Industrial Res., vol. 41, (2014), pp.279-291 [6] B. Demirel, P. Scherer, The roles of acetotrophic and hydrogenotrophic methanogens during anaerobic conversion of biomass to methane: a review, Rev. Environ. Sci. Biotechnol. vol.7, (2008), pp.173-190 [7] https://en.wikibooks.org/wiki/introductory_plc_programming. [8] Rexroth indralogic L20 03VRS system description operating and programming guide, (2004). [9] D. Baily, E. Wright, Practical SCADA for Industry, Elsevier journal of Process Plant, May (2003). Authors D.Ajay abilash, He graduated in Mechanical Engineering from Periyar Maniammai University, Tamilnadu, India in the year 2014. At present, he is doing MTECH Automation and control system in Mechanical Engineering Department, Periyar Maniammai University, Tamilnadu, India. His areas of interests include Automation and controls and design. He has been an author of more than 4 International Journal papers. P.Kayalvizhi, She graduated in Electronics and communication engineering from Anna university of technology, Tiruchirapalli, Tamilnadu, India in the year 2014. At present, she is doing MTECH Automation and control system in Mechanical Engineering Department, Periyar Maniammai University, Tamilnadu, India. Her areas of interests include Automation and controls and Embedded system. She has been an author of nearly 3 International Journal papers. Copyright c 2016 SERSC 179

R.Rakesh, He graduated in Electronics and communication engineering from Mount Zion college of engineering, tamilnadu, India in the year 2005. He received his M.E. degree in Industrial engineering from Anna University, CEG campus, Chennai, India in the year 2007 and also he received MBA degree. He had 2 years of working experience as software engineer in CTS. At present, he works as an assistant professor in Electronics and communication Engineering Department, Periyar Maniammai University, Tamilnadu,India. And he has been a corresponding author of nearly 7 National and International Journal papers. S.Balamurugan, He graduated in Automobile engineering from IRTT under Bharathiyar university, Erode, tamilnadu, India in the year 1999. He received his master s degree in Manufacturing engineering in 2006 from Sona college of technology, salem, India in the year 2006 and received his MBA degree in Human Resources management in 2004. At present, he works as an assistant professor in Mechanical Engineering Department, Periyar Maniammai University, Tamilnadu, India. And he has more than 12 years of teaching experience. 180 Copyright c 2016 SERSC