Lossnay Heat Recovery Ventilation

Similar documents
Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house

Energy Efficiency HOSPITALITY.

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Comfosystems Systems with heat recovery for a comfortable indoor climate

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

How to choose a heat pump and use it wisely

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

DUCTED AIR CONDITIONING SOLUTIONS

All the best brands all under one roof

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

How to choose a heat pump and use it wisely

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

Operation and Installation Manual. Max Series

Horizontal ventilation units

Delivering exceptional performance and Ecovalue. Ecocent

Samsung Room Air Conditioning

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

PCRNZ0710H. the. ultimate. heat pump air conditioning guide

Service & Maintenance:

Mistrale. Fusion Terminal

How To Make Your House Breathe

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

WHOLE-HOUSE VENTILATION SYSTEMS

Combi Unit Genius. The energy efficient Building Service Centre

Energy Efficiency. Bars & RestauRants.

Energy Saving Fact Sheet Air Conditioning

Before You Start an Energy Efficiency Retrofit The Building Envelope

air conditioners how to choose a cooling system

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Flexit air handling unit K2 R

Energy saving tips for home

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

The Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?

Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only

Heating and Ventilation

DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Installation, operation and maintenance manual TX 35A

Supplying. your home with. Our wall-mounted ventilator range: flexible, powerful ventilation technology for a healthy environment.

Home inspectors are not mold inspectors, however they do inspect for defects that

How To Get A Passive House

Dealing with damp, condensation and mould growth in your home.

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

THREE. Heating and Cooling

Screw Compressors ESM Fixed Speed & VS Variable Speed

Key energy-efficient features of your new home

york air-conditioning products Residential & VRF News 2015

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

Condensation. Some Causes, Some Advice

Basic Mold Prevention

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

technology innovation, comfort for your home. The perfect blend of

Mechanical and Natural Ventilation

Decree of the Ministry of the Environment on fire safety of ventilation systems

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Resources for School Energy Managers

READ ONLY INNOVATIVE SYSTEMS FOR PERFECTLY CONDITIONED AIR TRANE AIR HANDLERS TRANE AIR HANDLERS. Consistent comfort throughout your home

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Innovent LASER Packaged Fresh Air Conditioning Units

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

LG Electronics AE Company, Commercial Air Conditioning

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

Controlling moisture. For your home. Bellevue, WA Puget Sound Energy. pse.com/myrebates. P.O. Box /14

Breathing The Air In Your Home Is Like Living In A Closed Jar. It s Enough To Make You Sick.

HVAC Checklist - Long Form

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

bout your house before you start Renovating Your Bathroom

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

We have been working in an ideal climate for thirty years.

Dehumidification Frequently Asked Questions

THE ORIGINAL HIGH VELOCITY CENTRAL AIR CONDITIONING SYSTEM

A guide to using variable-speed drives and motors in swimming pool halls

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

Building and Grounds Maintenance Checklist

CE6500 Energy Recovery Ventilator

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT.

Energy Efficiency. Energy Efficient Home Cooling:

Dealing with damp and mould growth

Portable Air Conditioner

Lesson 36 Selection Of Air Conditioning Systems

Heating and cooling. Insulation. Quick facts on insulation:

Transcription:

Lossnay Heat Recovery Ventilation Clean, fresh air for a healthier, drier and warmer home. Balanced Pressure Home Ventilation. Made in Japan, designed for New Zealand Conditions.

Lossnay Fresh Air Heat Recovery Ventilation They say home is where the heart is. Because we spend so much time at home, the heart of the home should therefore be as healthy as possible for your whole family. Clean, fresh air is paramount to good health and overall wellbeing. Ventilation and airtight building design Creating a healthy living environment is important when renovating or building a new home you will want the perfect indoor climate year round. In addition to efficient heating and cooling, this should include the optimum amount of circulating fresh air. Current building regulations now demand homes to be built more airtight as they are subjected to higher insulation standards. But the option of leaving doors or windows open to allow more fresh air to enter is often not the solution from an outdoor noise or security perspective. Ventilation, condensation and moisture management The lack of natural ventilation due to airtight spaces can lead to the build-up of moisture laden stale air within the home. This is the perfect breeding ground for mould that can trigger allergy or respiratory problems. Furthermore, mould and dampness can also compromise both building materials as well as furnishings inside the home. Common places for mould to grow not only include window sills, curtains and carpets, but also walls and damp areas such as laundries, kitchens and bathrooms. Conventional positive pressure ventilation systems are not designed to deal with the additional moisture load from these damp areas. Lossnay is designed for today s modern homes The word Lossnay originated from the Japanese word Loss-Nai, meaning No Loss. Lossnay is a patented Balanced Pressure Heat Recovery Ventilation System specifically designed for more airtight homes built to the current New Zealand Building Code. It also complies with the Ventilation Standard NZS4303:1990 that specifically requires ventilation systems to draw fresh air from the outside and not the roof space to achieve acceptable indoor air quality. Bring fresh air in without draughts The Lossnay VL220 is an advanced Heat Recovery Ventilation System that brings in filtered fresh outdoor air to replace stale indoor air. The optimum number of air changes are regulated to ensure there are no draughts, whilst minimising temperature fluctuations when additional fresh air is introduced. This is important as too many air changes will lead to dramatic drops in indoor temperature that require unnecessary additional heating. Maximise heat recovery even from damp areas Because of its unique highly efficient heat recovery ability, the system maximises recovery of the available heat energy from outgoing stale air, as well as heat energy contained in moist air from damp areas such as bathrooms, toilets and kitchens. Pre-warm or cool air to save on your power bill This recovered heat energy is then utilised to pre-warm incoming air in winter or pre-cool this air in summer ultimately saving you on your heating or cooling bill. The end result is a healthier, drier and warmer home.

The Mitsubishi Electric Lossnay Difference What makes the Balanced Pressure Lossnay VL220 Heat Recovery Home Ventilation System from Mitsubishi Electric so different from other systems is our advanced Diamond Lossnay Core at the heart of the heat exchanger. Unlike ordinary positive pressure ventilation systems, the patented Diamond Core and built in drain outlet allows the system to also be effectively utilised in damp areas such as kitchens, bathrooms and toilets to help extract moisture and maximise recovery of additional heat energy from these damp areas at the same time. The available energy is absorbed and re-used to provide pre-warming in winter or pre-cooling in summer, rather than going to waste by directly transferring this air outside. In doing so, moisture build up in your home is minimised while healthy humidity levels are maintained and managed. The end result: your home is ventilated with fresh, filtered and clean pre-warmed (or cooled) air at the same time whilst maintaining optimum humidity levels for healthy living. The system is super energy efficient and designed specifically to be whisper quiet. FEATURES Draws in clean fresh air from the outside not the attic Removes stale air from the inside Circulates fresh air without draughts Controls moisture by managing humidity levels Heat recovery from stale outgoing air Efficient heat recovery from damp areas Whisper quiet operation from 14dBA Balanced Pressure Ventilation Designed for modern homes that are more airtight Why outside air, not attic air? Not all air is created equal. Lossnay only draws fresh air from the outside specifically it does not draw air from the attic. The absence of significant air movement common in attics means the air is likely to be stale. In addition, build-up of dust, dirt and other contaminants such as mould, insect and rodent droppings makes this air much harder to filter before it is distributed through your home. This is why the Balanced Pressure Lossnay system specifically utilises direct fresh air instead.

How It Works The Balanced Pressure Lossnay Heat Recovery Ventilation System removes stale, dirty air and draws in fresh air from outside. Lossnay also recovers heat energy from the air being transferred to pre-warm (or pre-cool) the fresh air being drawn into your home. The VL220 model is ideal for small to medium sized homes between 52m 2 and 192m 2. 1. The stale air extracted from your home is Return Air (RA). Return Air can contain high levels of CO 2, odours and other pollutants. This Return Air stream also contains heat energy that Lossnay can recover, which is not the case with other positive pressure ventilation systems. 2. As the stale Return Air is removed, Lossnay s core recovers the useful heat energy from it. The air is then exhausted (EA) outside along with the unwanted pollutants. 3. Outdoor Air (OA) is introduced to provide fresh clean air. It is first filtered, then passed through the Lossnay core. This allows it be pre-heated in winter (or pre-cooled in summer) using the energy recovered from the Return Air. 4. Supply Air (SA) then enters your house as fresh pre-heated or pre-cooled air. EXTRACTS STALE AIR Extracts stale air removing toxins and reducing humidity. SUPPLIES FRESH AIR Supplies fresh air increasing the oxygen levels in the home and assists with managing the build up of moisture. HEAT ENERGY RECOVERY Recovers up to 86% of the heat energy from the outgoing air to preheat the incoming air, saving you money. How Fresh Air Heat Energy Recovery Works EA Stale dirty indoor air (Exhausted Air) THE DIAMOND LOSSNAY CORE Outdoors Stale Indoors Fresh SA Fresh air into home (Supply Air) Partition plate Spacer plate OA Fresh air introduction (Outdoor Air) Fresh Stale RA Stale air removed from home (Return Air)

Balanced Pressure Heat Recovery Ventilation Benefits Ventilating your home is vital as it maintains air quality and reduces moisture, creating a healthier and more comfortable environment. The Mitsubishi Electric Lossnay System is a patented heat recovery ventilation solution that uses fresh air (not attic air) to ventilate your home. The system works by extracting stale air from inside your house and replacing it with allergen reduced fresh air from outside. Improved Air Quality By drawing in fresh outdoor air, indoor air quality is improved as high levels of CO 2, odours and other pollutants are removed from your home. Creates a Healthier Home Filtered fresh air improves air quality for allergy and asthma sufferers. Fresh Air Without Open Windows Lossnay allows you to have a well-ventilated home without the need to open windows. This improves the safety of your home and family and means outdoor noise is minimised. Energy Efficient Incoming fresh air is pre-warmed so your heating system isn t required to work as hard to reach desired temperature. This is highly energy efficient, and can help reduce heating bills. Retains Heat Lossnay s unique Heat Recovery Technology collects up to 86% of the heat energy in outgoing air which is then used to pre-warm or cool the fresh air vented in. Assists Moisture and Condensation Control Lossnay effectively reduces moisture in your home by directly removing stale air that causes condensation via the Lossnay core. Balanced Pressure, No Draughts Lossnay is specifically designed for more airtight homes built to the current New Zealand building code, bringing in the optimum amount of fresh air without creating draughts and minimising indoor temperature fluctuations. Easy Control At Your Finger Tips An intuitive wall controller with easy to read LCD display comes standard. Fan speed, night set back and 24-hour and weekly timers can easily be customised and programmed with up to 8 stop and start patterns per day. Quietest in its Class At an ultra quiet 14dBA in low fan speed, the Lossnay VL220 is the quietest system in its class. Easy To Clean The standard filters can be removed for regular cleaning to keep the unit in optimal working condition. Positive Pressure roof cavity ventilation VS Balanced Pressure Fresh Air Heat Recovery Ventilation These systems typically force air into the home from the attic space and specifically require gaps in the building structure (common in older homes) to facilitate air displacement. As these systems are not designed to recover heat energy to help pre-warm incoming air, colder incoming air will require more additional heating adding to your power bill. Air goes in and gets trapped Balanced ventilation mechanically removes stale air and replaces it with clean, fresh air at the same rate. It is also fitted with a heat exchanger that actively recovers heat energy from the outgoing stale indoor air to pre-warm incoming fresh air. As such, the need for additional heating of fresh air is reduced. This system is specifically designed for modern homes that are of more airtight construction. Fresh air goes in while stale air is pushed out

Lossnay VL220 Technical Specifications Sample Installation Dimensions 143 139 Power supply cable opening Ceiling suspension fixture 271 229 flange (SA) SA (Supply air) EA (Exhaust air) flange (EA) 885 8 174 119 33 Drain outlet 720 775(Ceiling suspension fixture) 815 8 848(Ceiling suspension fixture) 20 116 RA1 (Return air) 850 OA (Outdoor air) 199 86 31 80 234 295 flange (RA1) Auxiliary fixture flange (OA) 151 Exhaust air filter case 31 Type Lossnay - Residential 146 124 98 320 362 Model VL-220CZGV-E Drain pan Supply air filter case (Unit mm) Ventilation modes Heat recovery mode Bypass Heat exchange system Heat exchange element material Operating range Air to Air sensible heat exchanger Specially treated non permeable resin core OA temperature -5 C* to +40 C, 80%RH Weight (kg) 31 Electrical power supply 220-240 V / 50Hz 220V / 60 Hz Fan speed Fan Speed 4 Fan Speed 3 Fan Speed 2 Fan Speed 1 Input power (W) 80 35 18.5 8.5 Air volume (m 3 /h) 230 165 120 65 (L/s) 64 46 33 18 External static pressure (Pa) 164 84 44 13 Temperature exchange efficiency (%) 82 84 85 86 Noise (db) (Measured at 1.5m under the centre of an anechoic chamber) 31 25 19 14 Duct size 150mm *Return Air will continue to operate from -5 C to -15 C. Optional VL220 Extras Lossnay Sizing Guide VL-220CZGV-E House Size m² Ceiling Height m² House Air Volume m³ NZ 4303 m³/hr BS Standard m³/hr Fan Speed 25 2.4 60 21 30 1 50 2.4 120 42 60 1 75 2.4 180 63 90 2 100 2.4 240 84 120 2 125 2.4 300 105 150 3 150 2.4 360 126 180 4 175 2.4 420 147 210 4 190 2.4 456 160 228 4 House Size m² Ceiling Height House Air NZ 4303 BS Standard Fan Speed m² Volume m³ m³/hr m³/hr 25 2.7 68 24 34 1 50 2.7 135 47 68 2 75 2.7 203 71 102 2 100 2.7 270 95 135 3 125 2.7 338 118 169 4 150 2.7 405 142 203 4 175 2.7 473 166 237 4 House sizing guide is based on British Standard for ventilation requiring 0.5 Air changes per hour. New Zealand standard (NZ4303) is 0.35 air changes per hour Filters The VL220 Ventilation system is supplied with 2 standard (G3) replacement filters that can be washed up to 4 times. The 2 exhaust Filters can be upgraded to non-washable medium efficiency filters (G4). The 2 supply filters can be upgraded to non-washable high efficiency filters (M6). Bypass Damper When the outdoor temperature is cooler than the indoor temperature (and vice versa) the optional damper allows a bypass of the heat exchanger should temperature conditions reach set levels. Exhaust fans Mitsubishi Electric offer a range of energy efficient exhaust fans that feature low vibration and quiet operation ideal for the extraction of moisture and contaminants in bathrooms and kitchens. These exhaust fans are designed to specifically work in harmony with the Lossnay VL220 system. 5 Year Warranty The Mitsubishi Electric Lossnay product in this brochure comes with a full 5 year parts and labour warranty. Warranty conditions apply. WELLINGTON HEAD OFFICE AUCKLAND BRANCH CHRISTCHURCH BRANCH www.mitsubishi-electric.co.nz 1 Parliament Street PO Box 30772 Lower Hutt 5040 Unit 1, 4 Walls Road PO Box 12726 Penrose, Auckland 1642 44 Halwyn Drive PO Box 16904 Hornby, Christchurch 8441 Phone (04) 560 9147 Fax (04) 560 9133 Phone (09) 526 9347 Fax (09) 526 9369 Phone (03) 341 2837 Fax (03) 341 2838 All features and specifications are subject to change and amendment at anytime. May 2016.