COMPLEAT TM HTF HEAT TRANSFER FLUID COMPLEAT TM HTF ETHYLENE GLYCOL COMPLEAT TM HTF PROPYLENE GLYCOL

Similar documents
ALS TRIBOLOGY Engine Coolant Reference Guide

NORKOOL Industrial Coolants

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

Cooling System Maintenance Products COOLANT

Dispelling the Myths of Heat Transfer Fluids. Kevin Connor The Dow Chemical Company

Abrasive Solids Corrosion inhibitors and hard water components that have come out of the coolant solutions and may lead to premature water pump

Delo XLI Corrosion Inhibitor

DOWFROST GEO 20: Propylene Glycol-Based Heat Transfer Fluid for Geothermal Heat Pump Systems

2014 Service Technician Training Program Closed Loop Systems

WATER TABLE WINNERS!

COOLANT REQUIREMENTS FOR ENGINE COOLING SYSTEMS 2 GLOSSARY

Pink X X X X X X X CAT Diesel Engine Antifreeze Coolant. Pink X X X X X X X Detroit Diesel PowerCool

Selective Catalytic Reduction (SCR) and Diesel Exhaust Fluid (DEF) Training Module

CONVERTING A CLOSED-LOOP WATER SYSTEM TO A GLYCOL SYSTEM

Poor maintenance can lead to costly damage

NALCO WT-1000 Closed System Corrosion Inhibitor

Mobil Antifreeze Advanced

Metal Rescue Rust Remover Technical Data

Ingredient CAS Number Weight % ACGIH TLV PEL STEL Phosphoric Acid mg/m3 1 mg/m3 3 mg/m3

TABLE OF CONTENT

Do the Right Thing: M-B Anti-Freeze Recommendations

DETERGENTS. Application Recommendations. Application/ Concerns. Recommended Detergent. Articles Cleaned/ Soil Removed. Cleaning Method.

Product Sheet HEAT TRANSFER FLUIDS. Leak Indicator- Clariant CERTIFIED LEAK-INDICATOR-FLUID FOR DOUBLE-WALLED TANKS

Ultra Coolant. The Best Performance. The Best Cost. The Best Coolant.

Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources

FOOD GRADE INDUSTRIAL OILS & GREASES

Introducing an All New Line of Cleaning Chemicals

WATER CHEMISTRY AND POOL WATER BALANCE

Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS

ENGINE COOLING SYSTEM

A step-by-step guide Prevent freezing pipes and other damage by winterizing your RV.

Diesel Exhaust Fluid (DEF) Q & A

Series 53, 71, 92 and 149 Engines

OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS

LIQUID FERTILIZER FORMULATIONS

Scaletec Plus. Descaling Overview, Guidelines, Cleanup Tips, And Question & Answers

Corrosion Inhibitors in Antifreeze Coolants

KS3 Science: Chemistry Contents

THE USE OF OZONE IN COOLING TOWERS

Advantages and Disadvantages of Low VOC Vegetable Based Metalworking Fluids

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

MAINTAINING YOUR SPA WATER

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Material Safety Data Sheet

Warm-Up 9/9. 1. Define the term matter. 2. Name something in this room that is not matter.

SAFETY DATA SHEET West Skyhawk Drive West Jordan, UT U.S.A. Phone

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Material Safety Data Sheet

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

: Water and Glycol Leak Detection Solution

RO / NF Cleaning Guidelines

BiO-STiX Drain Cleaner & Deodorizer

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

Screw Plug Immersion Heaters

Case History Report The Dolphin Nonchemical Device Boilers and Cooling Tower

Carolina s Solution Preparation Manual

MATERIAL SAFETY DATA SHEET

steam centre of excellence Steam Boiler System Optimization

World Headquarters Hach Company Date Printed 9/28/10 SAFETY DATA SHEET 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

If you accidentally get battery acid on your skin, flush it with lots of water

IMO Approved Tank Cleaning Chemicals

MATERIAL SAFETY DATA SHEET

For Improved Heat Transfer Performance... NORKOOL Cleaner, Degreaser, and Inhibitor 244. System Maintenance

MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

PRODUCT SAFETY DATA SHEET According to 91/155 EC 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING

BASIC WATER TREATMENT OF STEAM BOILERS

WATER-SOLUBLE METALWORKING FLUIDS

Adjusting Chemical Levels in a Swimming Pool

Stormwater Ponds. c ıty of a bı le ne st or m wat e r utı lıty dıv ısı on

Calcite PH Nutralizer System

Antifreeze plays an essential role in maintaining

DOW CORNING CORPORATION Material Safety Data Sheet

Cat S O SSM. Services. Understanding Your Results. Understanding Your: S O S Oil Reports S O S Oil Results S O S Coolant Reports S O S Coolant Results

3/5/2015. Oil Analysis Tests. Lubricating Oils. Six Functions of Lubricating Oil

CLEANING AND SANITIZING

Waste Hazardous? Why?

LPG, Flammable Liquids, Toxic and Corrosive Substances

Safety Data Sheet Avesta Neutralization Agent 502

Winterizing Your Trailer and Storage Ideas

Material Safety Data Sheet

Basic Pool & Spa Care

Partnering with Nature for a Cleaner Tomorrow

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

ACUSOL 820 Rheology Modifier and Stabilizer

Parker Hannifin Corporation Process Advanced Filtration Division 2340 Eastman Avenue Oxnard, California USA

CARING FOR YOUR WATER HEATER

MATERIAL SAFETY DATA SHEET

Food processing industry. Your production is secure with nevastane lubricants

Oxivir Tb and Accelerated Hydrogen Peroxide (AHP) Frequently Asked Questions

FANTASTIK SCRUBBING BUBBLES ALL PURPOSE CLEANER HEAVY DUTY

Shell Fleet Management working with you to keep your fleet moving.

Produced water from oil and gas production

There are no supported uses of Ethylene Oxide in direct consumer products. It is not used in a widespread or dispersive manner.

: CRYSTAL CLEAN DRAIN CLEANER CRYSTALS

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

UCON Fluids and Lubricants

Determination of calcium by Standardized EDTA Solution

RAILROAD COMMISSION OF TEXAS APPENDIX C LIST OF E&P WASTES: EXEMPT AND NONEXEMPT

Material Safety Data Sheet

Iron and manganese are two similar elements

Transcription:

COMPLEAT TM HTF HEAT TRANSFER FLUID COMPLEAT TM HTF ETHYLENE GLYCOL COMPLEAT TM HTF PROPYLENE GLYCOL

FLEETGUARD COMPLEAT HTF HEAT TRANSFER FLUID In normal operations, heavy duty, liquid-cooled stationary engines and gen-sets are exposed to significant variations in temperature and weather conditions, and must be protected against both freezing and overheating. In addition, the antifreeze/coolant used in these engines must be formulated to provide diesel engine liner pitting protection, prevent corrosion and scale buildup, while operating at maximum efficiency. Compleat HTF Heat Transfer Fluids have been formulated to meet the special needs of both stationary engines and line heaters. Compleat HTF is a universal heat transfer fluid, and can be used in the following applications: APPLICATIONS: Natural Gas Line Heaters LNG Vaporizers Natural Gas Well-Head Heaters Crude Oil Heaters Standby Engines/Gen-Sets Stored Equipment Heavy-Duty Diesel Engines Automobile & Light Duty Engines Natural Gas Compressor Engines Air Compressor Engines Drilling Equipment Irrigation Equipment Heat Tracing Systems Building Heating/Cooling Systems Refrigeration Systems (non food) FEATURES: Compleat HTF products are premium Heat Transfer Fluids and Universal Heavy Duty Antifreezes. They provide a superior, non-corrosive medium for Line Heaters, Choke Heaters, and Stationary Engines. HTF products contain DCA4, a Phosphate/NitriteMolybdate chemical inhibitor system which provides superior protection against ferrous metals corrosion, scaling, liner pitting, and cavitation. Compleat HTF Propylene Glycol is a less toxic, environmentally friendly product. DCA4 Supplemental Chemical Additive is available for reinhibition of heating and cooling systems. Restore and Restore Plus Cleaners are available for system cleaning. Analytical Services are available through the Fleetguard Monitor C Program. 3-Way test strips are available for field coolant testing. Compleat HTF products are available in Concentrate and Premix in bulk and drums.

COMPLEAT HTF ETHYLENE GLYCOL COMPLEAT HTF EG CONCENTRATE is a premium quality, silicate-free, inhibited Ethylene Glycol based heat transfer fluid and industrial coolant. It contains DCA4, an effective heavy duty chemical inhibitor system which protects diesel engines from liner pitting, corrosion, and from hard water scale deposits. Compleat HTF EG CONCENTRATE is intended for dilution with demineralized water or tap water with low mineral content. COMPLEAT HTF EG is a premium quality, silicate-free, inhibited Ethylene Glycol based heat transfer fluid that also contains DCA4 heavy duty chemical inhibitor. It is intended for use in areas where demineralized or deionized water is not available. It is premixed 50/50 with demineralized water to provide protection down to 34 o F, eliminating the need for dilution at the point of use. COMPLEAT HTF PROPYLENE GLYCOL COMPLEAT HTF PG CONCENTRATE is a premium quality, silicate-free, fully inhibited Propylene Glycol based heat transfer fluid and industrial coolant. Because of the PG based fluid and DCA4 inhibitor, Compleat HTF PG provides superior diesel engine liner pitting and corrosion protection. Compleat HTF PG is less toxic than EG based heat transfer fluids, environmentally friendly and fully biodegradable. Compleat HTF PG Concentrate is intended for dilution with demineralized water or tap water with low mineral content. COMPLEAT HTF PG is a premium quality, silicate-free, fully inhibited Propylene Glycol based heat transfer fluid which is premixed 50/50 with demineralized water. It contains DCA4 chemical inhibitor, and is intended for use in areas where demineralized water is not available. As a 50/50 Premix, if offers freeze protection down to 27 o F. Improved freeze protection can be achieved by increasing the glycol content to a 60/40 dilution ( 56 o F), or a 55/45 ( 40 o F). DCA4 TM INHIBITOR DCA4 TM INHIBITOR is a state-of-the-art Supplementary Chemical Additive (SCA) which is designed to re-inhibit heat transfer fluids and industrial coolants. DCA4 Inhibitor is an environmentally friendly, less toxic chemical, which provides superior hard and soft metal protection in industrial coolant systems. In the course of normal operations, the chemicals in the heat transfer fluids and industrial coolants deplete. Depletion rates are dependent on several factors including: operating conditions, excessive dilution, system leaks, blow by gases, etc. The use of DCA4 Inhibitor re-inhibits depleted coolant systems and extends the useful life of the coolant. COOLANT ANALYSIS PROGRAM MONITOR-C TM is a coolant analysis program designed to assist our customers in monitoring their heat transfer and industrial coolant systems. The Monitor-C program provides a detailed analysis of the depletion rates of the buffering agent chemicals, aluminum protection, liner pitting and corrosion protection, coolant concentration and freeze point, and the supplemental additive chemical needed to reinhibit the system. The Monitor-C analysis services are available through Compleat HTF distributors. 3-Way SCA Test Strips provide easy field testing of cooling systems for corrosion inhibitors and freeze point. Quik-Chek Test Strips provide easy field testing of ph, Chloride, and Sulfate coolant condemnation levels.

PHYSICAL PROPERTIES ETHYLENE GLYCOL EG CONC EG 60 60/40 EG 50 50/50 EG 40 40/60 EG 30 70/30 Composition, % volume (min) 95.0% 60.0% 50.0% 40.0% 30.0% Color Blue Blue Blue Blue Blue Specific Gravity, 60/60 o F 1.13 1.09 1.08 1.06 1.05 Pounds per Gallon, 60 o F 9.41 9.07 9.01 8.83 8.74 Freezing Point, o F % aqueous sol by volume 8-65 -34-10 4 ph of Solutions N/A 10.5 10.5 10.5 10.5 Reserve Alkalinity (min) 10.0 5.0 5.0 5.0 5.0 Boiling Point, o F 345 230 226 222 220 Flash Point (PMCC), o F 265 None None None None Fire Point (COC), o F 250 None None None None Ash Content, Mass % (max) 5.0 2.5 2.5 2.5 2.5 PROPYLENE GLYCOL PG CONC PG 60 60/40 PG 50 50/50 PG 40 40/60 PG 30 70/30 Composition, % volume (min) 95.0% 60.0% 50.0% 40.0% 30.0% Color Blue Blue Blue Blue Blue Specific Gravity, 60/60 o F 1.06 1.055 1.05 1.04 1.03 Pounds per Gallon, 60 o F 8.82 8.78 8.74 8.66 8.58 Freezing Point, o F % aqueous sol by volume -70-56 -27-6 10 ph of Solutions N/A 10.5 10.5 10.5 10.5 Reserve Alkalinity (min) 10.0 5.0 5.0 5.0 5.0 Boiling Point, o F 320 225 222 219 216 Flash Point (PMCC), o F 225 None None None None Fire Point (COC), o F 220 None None None None Ash Content, Mass % (max) 5.0 2.5 2.5 2.5 2.5

INSTALLATION OF COMPLEAT TM HTF When installing Compleat HTF products, it is important to determine the quality of the available water supply by analysis. Water with low total dissolved solids (TDS) is always recommended. If local water has low total dissolved solids, or if softened or demineralized water is available, it is acceptable to use Compleat HTF EG Concentrate or Compleat HTF PG Concentrate. If good water is not available locally, Compleat HTF EG Premix or HTF PG Premix products with demineralized water should be used to ensure that water quality requirements are met. COOLANT SYSTEM PREPARATION Before installing Compleat HTF EG or PG products, the coolant system should be completely drained and flushed with water. If rusting or scaling has occurred, the system should be chemically cleaned with Fleetguard Restore (alkaline chemistry for cleaning silica gelation) or with Restore Plus (acid chemistry for cleaning corrosion, rusting or scaling). Follow instructions for both Restore and Restore Plus as printed in their respective brochures. Note: If the cooling system being treated contains a competitive product, an analysis of the fluid is recommended to determine its current condition, level of inhibition, and compatibility with the selected Compleat HTF product being used. Whether a cooling system is cleaned for silica gel or rust and corrosion, it is important that all traces of chemical cleaning agents be completely drained and flushed with water before introducing new Compleat HTF products. The procedure for installing Compleat HTF EG or PG products in in-line heaters generally will parallel those used in stationary engines or gen-sets. COOLANT SYSTEM TESTING PROCEDURES Cooling systems should be checked on a regular basis to determine freeze point, reserve alkalinity, ph, and corrosion inhibitor levels. Fleetguard offers coolant testing kits (CC2602) which can be used to do field spot checks for corrosion inhibitor levels, and refractometers (CC2806) to determine freeze protection of both Compleat HTF EG and PG products. Fleetguard s Quik-Check 3-Way Test Strips (CC2607) checks used coolant quality levels. This annual check tests for ph, Chloride, and Sulfate coolant condemnation levels. It is recommended that coolant systems be sampled at least once per year and a full analysis performed. Fleetguard offers coolant analysis services through its Monitor C Program. Monitor-C Coolant Analysis bottles with mailers (CC2700) are available through your Fleetguard Compleat HTF Distributor. COOLANT SYSTEM RE-INHIBITION When analysis of coolant system samples indicates that re-inhibition is required, Fleetguard DCA4 Supplemental Coolant Additive (SCA) should be added to the system. DCA4 is a premium quality SCA which provides superior coolant system protection by adding required inhibitors to replace those depleted through use, and adds phosphates buffering agents to control corrosion and scaling. DCA4 Supplemental Coolant Chemical inhibitor is less toxic than other borate buffered inhibitors, and reduces the risk of SCA overcharging.

FREEZE POINT ADJUSTMENT If a lower freezing point is required, the glycol concentration must be increased. Check the freeze point of the coolant system using a refractometer, and determine its capacity. Use the freeze point chart below to determine the approximate glycol concentration volume percent. The following formula should then be used to determine the amount of Compleat HTF Concentrate to be added to the system to achieve the desired freeze point. Drain the system of a portion of the coolant equal to the estimated required to adjust the freeze point. (Example below 286 gallons required) Compleat HTF Concentrate = Sys capacity gal X (Desired Conc Vol% Present Conc Vol%) to be added 100% Present % Concentration Vol % Example: Present Desired Freeze Point ( o F) 3-34 Coolant Concentration Vol % 30 50 Therefore, using the above equation gives: Gallons of Compleat HTF = 1000 gal X (50% 30%) Concentrate required 100% 30% = 286 gallons required

COMPLEAT HTF EG AND PG TOXICITY ETHYLENE GLYCOL The toxicity threshold limit of any material per EPA regulations is: 5 GRAMS/KILOGRAM OF BODY WEIGHT Toxicity is measured by feeding the material to rats and measuring the grams of the material per kilogram of the rat body weight required to kill 50% of the rats in the population eating the material. This number is referred to as the LD50 of the material. The lower the number, the more toxic the material. Following are the LD50 values for various forms of Ethylene Glycol. These figures show that EG based coolants do exceed the toxicity threshold limits as set by EPA. ETHYLENE GLYCOL EG ANTIFREEZE CONCENTRATE EG COMPLEAT CONCENTRATE = 5.0-5.5 GR/KG = 4.0-4.5 GR/KG = 5.0-5.5 GR/KG PROPYLENE GLYCOL Compleat HTF PG Products contain Propylene Glycol which is low in oral toxicity, and has received a generally recognized as safe designation from the FDA. PG has been used for many years as an ingredient in food, cosmetics, and medicinal products. PG HTF products, due to their low toxicity, are often used in engines that are in or near food processing plants, or in truck cooling/heating systems that transport food products. Compleat PG Concentrate or Premix products present an advantage over EG products because of substantially lower human and animal toxicity. Following are the LD50 values for various forms of Propylene Glycol. These figures show that PG based coolants do not exceed the toxicity threshold limits as set by EPA. PROPYLENE GLYCOL PG ANTIFREEZE CONCENTRATE PG COMPLEAT CONCENTRATE = 28.8 GR/KG = 26.0 GR/KG = 23.0 GR/KG COMPLEAT HTF EG AND PG BIODEGRADABILITY Heat Transfer Fluids, whether EG or PG, should never be dumped or spread into the environment, because either may contain hazardous contaminants, such as lead or benzene. However, if spilled into the environment accidentally, both EG and PG HTF products are fully biodegradable. While there are small differences in their rates of biodegradation, both biodegrade. It should be noted that cold temperatures cause rates of biodegradation for both EG and PG to slow or stop entirely, and that until fully biodegraded, EG presents a significant risk to pets, humans and wildlife. PG, however, is essentially non-toxic to animals and safer to the environment.

FLEETGUARD COOLANT PRODUCTS DCA4 Water Filters DCA4 Liquid Supplemental Coolant Additives Compleat HTF EG Concentrate and Premix Compleat HTF PG Concentrate and Premix Monitor C Coolant Analysis Program 3-Way SCA Test Strips Quik-Chek Coolant Quality Test Strips Refractometer for EG and PG Coolant Restore Alkaline Based Cleaner Restore Plus Acid Based Cleaner Coolant System Training Programs For more information, call your Customer Assistance Representative at 1-800-22FILTER (1-800-223-4583), fax 1-800-999-8664 or visit us at www.fleetguard.com LT15051 2/01 2001 Fleetguard, Inc.