The NOW! Test Validation Testing

Similar documents
Laboratory Exercise # 11: Differentiation of the Species Staphylococcus and Streptococcus

BACTERIAL ENUMERATION

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

Disc Diffusion Susceptibility Methods

Testing Waste Water for Fecal Coliforms and/or E.coli using Colilert and Colilert -18 & Quanti-Tray

BACTERIA COUNTS IN RAW MILK

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

LAB 4. Cultivation of Bacteria INTRODUCTION

Quantifying Bacterial Concentration using a Calibrated Growth Curve

MTT Cell Proliferation Assay

Result: COMPLETE Report Date: 08-OCT-2012

Prevention of Nosocomial Infections with KLEANIK Self - Disinfecting Drain Trap

Marine Microbiological Analysis of Ballast Water Samples

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

Transformation Protocol

Biological Sciences Initiative

GROWING BACTERIA INTRODUCTION

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

URINE CULTURES GENERAL PROCEDURE

UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009

Welcome to Implementing Inquirybased Microbial Project. Veronica Ardi, PhD

Lab Exercise 3: Media, incubation, and aseptic technique

`TORAY TEXTILES EUROPE

Lab Exercise 2 Media and Culture

HOW TO WRITE AN UNKNOWN LAB REPORT IN MICROBIOLOGY

TransformAid Bacterial Transformation Kit

Medical Device Reprocessing: How to Ban the Biofilm!

Transferring a Broth Culture to Fresh Broth

Evaluation of Microbial Growth and Survival on Construction materials treated with Anabec NewBuild 30

In order to be useful, a smear must have the following qualities:

BD Modified CNA Agar BD Modified CNA Agar with Crystal Violet

Enumerating Chromogenic Agar Plates Using the Color QCOUNT Automated Colony Counter

Enteric Unknowns Miramar College Biology 205 Microbiology

Testing of disinfectants

SELECTIVE AND DIFFERENTIAL MEDIA

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM ANALYSIS OF TOTAL COLIFORMS AND E. COLI IN DRINKING WATER

Gelatin Hydrolysis Test Protocol

INOCULATION PROCEDURES FOR MEDIA QC

TECHNICAL REPORT on the disinfection systems in dental unit water lines.

Hand and Glove Hygiene Keys to Safe Compounding

In use test of a Washer-disinfector reprocessing of flexible endoscopes

ENUMERATION OF MICROORGANISMS. To learn the different techniques used to count the number of microorganisms in a sample.

Ozone Inactivation Kinetics of Multiple Antibiotic Resistant Strains of Bacteria in Water.

PURE CULTURE TECHNIQUES. To demonstrate good aseptic technique in culture transfer or inoculation and in handling sterile materials.

Testing the Efficacy of Antimicrobial Substrates. Inhua Muijrers-Chen, Ph.D. Zuyd University of Applied Sciences

Oxygen relation Definition Examples Picture Facultative Anaerobe

Raw Milk Quality Tests Do They Predict Fluid Milk Shelf-life or Is it time for new tests?

Microbiology BIOL 275 DILUTIONS

Normal flora, which make up about 90% of the cells of a human body, are microbes that

Transformation Kit BACTERIAL TRANSFORMATION: GREEN FLUORESCENT PROTEIN. Partnership for Biotechnology and Genomics Education

Media fills Periodic performance qualification (Re-Validation)

Personal Injury TYPES OF HOLIDAY ILLNESSES. Telephone

Mycoplasma Testing Products & Services. M-175 CELLshipper Mycoplasma Detection Kit (In-house sample preparation and slide fixation)

ON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)

FACULTY OF MEDICAL SCIENCE

Presentation at the 3 rd SAFOODNET seminar

ABSTRACT. CFU/ml in case of air water syringe, log 10 CFU/ml in case of high speed air turbine hand-piece and log 10

Laboratory Protocols Level 2 Training Course Isolation of thermotolerant Campylobacter from faeces

Bacterial Detection and Live/Dead Discrimination by Flow Cytometry

IDENTIFICATION OF OTHER UNKNOWN BACTERIAL SPECIES: OU

Sampling of the surface contamination using sterile cotton swabs from toys obtained from

Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.

Introduction. Introduction. Why do we need microbiological diagnostics of udder infections? Microbiological diagnostics How is it done?

Green Fluorescent Protein (GFP): Genetic Transformation, Synthesis and Purification of the Recombinant Protein

PRINCIPLES AND EXPLANATION OF THE PROCEDURE

UltraClean Soil DNA Isolation Kit

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

CHALLENGES AND FUTURE FORECASTS OF MEASUREMENT TECHNOLOGIES IN WATER MICROBIOLOGY

Flow Cytometry Analysis of the Activity of Disinfecting Agents Tested with Staphylococcus aureus and Escherichia coli

HiPer Ion Exchange Chromatography Teaching Kit

ENVIRONMENTAL MONITORING

INTERNATIONAL JOURNAL OF PHARMACY & LIFE SCIENCES

ADP/ATP Ratio Assay Kit (Bioluminescent)

Urinary Tract Infections

Diagnostic Techniques: Urine Culture

AURAMINE O STAIN. Preanalytical Considerations

National Food Safety Standard Food microbiological examination: Aerobic plate count

Aerobic Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Aerobic Count Plate

AFDO 2010, Norfolk, VA James Marsden Regents Distinguished Professor Jasdeep Saini Kansas State University

Transformation of the bacterium E. coli. using a gene for Green Fluorescent Protein

Adapted from Biology 15 Laboratory Supplemental Manual: Wrightsman, Ininns and Cannon- Moloznic.

GRS Plasmid Purification Kit Transfection Grade GK (2 MaxiPreps)

NEW SELECTIVE AND DIFFERENTIAL MEDIUM FOR COAGULASE-POSITIVE STAPHYLOCOCCI ALLOWING RAPID GROWTH AND STRAIN DIFFERENTIATION'

LAB 16 Rapid Colony Transformation of E. coli with Plasmid DNA

Environmental Monitoring

The Financial Benefits of the MicroSEQ Microbial Identification System

3M Food Safety. Quality Solutions. for. Testing Times

THE BASICS OF DECONTAMINATION

DNA CAN BE TRANSFERRED BETWEEN BACTERIA GENETIC ENGINEERING USING RECOMBINANT DNA TECHNOLOGY

Guidelines for Assuring Quality. Medical Microbiological Culture Media

An Overview of Legionella Analyses By Diane Miskowski, MPH EMSL Analytical, Inc. October 2014

CHAPTER 13. Quality Control/Quality Assurance

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Cold Agglutination Titer detecting Cold Reacting Antibodies

Isolation of Starch degrading bacteria Enzymes in Action

Hydrogen Peroxide Cell-Based Assay Kit

Transcription:

The NOW! Test Validation Testing Kaumudi Kulkarni, M.S. The NOW! Test is a test to check flexible endoscopes for gram negative bacteria, after reprocessing. It is a fluorometric diagnostic system that can be used to provide a fast diagnosis (~12 hours) of low levels of gram negative bacteria, claim for this test being <10 Colony Forming Units (CFU). Testing can be done in the endoscopy clinic or within the facility, thus not requiring sending the sample to a laboratory for testing. The NOW! Test detects gram negative bacteria like E. coli, Pseudomonas aeruginosa, Klebsiella, Salmonella, Helicobacter, Serratia, Legionella, associated with patient infection after endoscopic procedures. It also detects the multidrug resistant CRE strains of these organisms. Gram negative bacteria act as indicators for bacterial contamination in endoscopes and reduce the risk of false positives associated with the gram positive bacteria occurring normally as skin flora like Staphylococcus epidermidis, Streptococcus salivarius. BACKGROUND Due to the complex physical design of flexible endoscopes, any slight deviation from the recommended reprocessing protocol can lead to the survival of microorganisms in the suction channels (Alfa, M.J., et al. American Journal of Infection Control, 2006). If microorganisms survive the steps of endoscope reprocessing, it could potentially lead to subsequent patient infection. Nosocomial outbreaks linked to endoscopes contaminated with gram negative bacteria have been frequently reported (Muscarella L.F., Infect Control Hosp Epidemiol. May 2002). Gram negative bacteria replicate more easily in the presence of moisture, and have been implicated in endoscope associated infections more frequently than gram positive bacteria (Alfa M.J. et al. J Hosp Infect 1991). Contamination and colonization of automated endoscope reprocessors (AERs) may also result in exposure of the endoscopes to pathogens. There is a need to have a rapid test that detects microbial growth inside the lumens of reprocessed endoscopes. This led to the conception of the NOW! Test. The kit comprises a sensitive test specific to gram negative bacteria. WORKING PRINCIPLE OF THE NOW! Test The NOW! Test works by detecting an enzyme mechanism typical to the gram negative bacteria. The test utilizes a fluorogenic substrate which, when hydrolyzed by a specific enzyme present in gram negative bacteria, produces fluorescence that is then read by the fluorometer. 1

The reading correlates to the amount of the bacterial enzyme present, which in turn relates directly to the number of gram negative bacterial cells present. INDEPENDENT THIRD PARTY LABORATORY TESTING The test was validated by two independent testing laboratories. The purpose of this study was to evaluate the sensitivity of the NOW! Test in the detection of gram negative bacteria. Laboratory 1 tested the kit with the CRE strains of three different gram negative bacteria (Escherichia coli ATCC BAA-2469, Pseudomonas aeruginosa ATCC BAA 2110, and Klebsiella pneumoniae ATCC BAA-1705) and Laboratory 2 tested the kit with three non-cre strains of bacteria (Escherichia coli ATCC #8739, Pseudomonas aeruginosa ATCC #9027, and Klebsiella pneumoniae ATCC #4352). Side by side traditional culturing was done by these labs to verify the sensitivity. Both the laboratories performed the same protocol for testing. The protocol was as follows: Bacteria to be tested: 1. Escherichia coli 2. Pseudomonas aeruginosa 3. Klebsiella pneumoniae Each organism was diluted and analyzed with both the fluorometer and by culturing on nutrient agar. Preparing Bacterial Standards I. Culture a gram negative bacteria sample so it is 16-18 hours old (not more than that) when it is ready to use. Use 5% Sheep s blood agar as culture medium. II. Suspend a loop of bacteria into sterile water to match a CFU standard. (For example, using a spectrophotometer A 600 = 0.12 is equivalent to a 0.5 McFarland Standard, or 1.5 x10 8 CFU for E.coli.) III. Perform a 10-fold serial dilution keeping the final volume at 1 ml. (For example, taking 100 μl of a 10 4 CFU sample into 900 μl of sterile water gives you a 1000 CFU sample). To test for specific low CFU counts, like 1 CFU for example, you would need to make a specific dilution at 1 CFU/500μL. To keep the final volume of the dilution at 1 ml, this would mean making a 2 CFU/1mL dilution. To follow this example, you could take 200 μl of a 10 CFU/mL sample and add 800 μl of sterile water to it to get 2 CFU/mL. IV. Verify CFU level by plating a full ml of the dilution level, and incubating for 24-48 hours at 37⁰C. Count the colonies formed. Testing Protocol Prepare a stock solution of sterile growth medium at a concentration of 150 mg/ml. Dispense 49.5 μl of the growth medium into as many cuvettes as needed, aseptically. 2

Add 500 μl of a water sample (or bacterial standard) to a growth medium containing cuvette. Mix well, place into the block incubator set at 37⁰C, and incubate 8-12 hours. Remove the cuvette from the incubator and let the cuvettes cool down. Turn on the fluorometer Add 2 drops of Reagent A to the cuvette and gently invert it a few times to help mix the reagent with the sample. Make sure there are no air bubbles in the cuvettes, as these will interfere with the reading of the fluorescence and may produce inaccurate test results. Place the cuvette in the fluorometer so the hinge is facing the right, and the pointy side of the cuvette is lined up with the black line in the reader. Press Measure and then 360 Press Blank, and wait for it to finish measuring. Press Measure. The fluorometer will take an initial reading after a few seconds, and then the final reading after 10 minutes. Record the final reading. The initial reading doesn t need to be recorded. Direction for conducting the negative control Prepare cuvettes with sterile growth medium as mentioned above. Add 500 μl of sterile water to the cuvette. Close the lid, mix gently and place into the block incubator set at 37⁰C, and incubate overnight. Remove the cuvette from the incubator and let it cool down. Turn on the fluorometer, and place the cuvette in the fluorometer so the hinge is facing the right, and the pointy side of the cuvette is lined up with the black line in the reader Press Measure and then 360 Press Blank, and wait for it to finish measuring. Press Measure. The fluorometer will take an initial reading after a few seconds, and then the final reading after 10 minutes. RESULTS For both the labs, the negative controls readings were below 300, most of them being under 200. The bacterial sample dilutions of 10 CFU or higher had readings above 300. Following are the Summary Tables of each organism tested from the laboratories: 3

RESULTS FROM LABORATORY 1: The first column indicates the targeted number of CFU in the dilution series. The second column indicates the actual number of CFU in the side by side traditional culturing of the same dilution. The third column indicates the final reading on the fluorometer. Data Table for E.coli BAA 2469 Theoretical CFU Actual Average CFU Fluorometer Reading 10 9 470 10 10 377 5 8 252 5 6 290 1 2 252 1 2 270 5 6 246 5 9 247 ~2.5 4 213 ~2.5 2 189 <1 1 222 <1 1 249 Negative Control 0 0 167 Negative Control 0 0 137 Data Table for Pseudomonas aeruginosa BAA 2110 Theoretical CFU Actual Average CFU Fluorometer Reading 10 5 470 10 3 465 5 2 296 5 2 244 1 1 471 4

1 1 231 5 6 295 5 4 222 ~2.5 3 227 ~2.5 4 192 <1 1 203 <1 1 202 Negative Control 0 0 193 Negative Control 0 0 126 Data Table for Klebsiella pneumoniae BAA 1705 Theoretical CFU Actual Average CFU Fluorometer Reading 10 17 609 10 16 1644 5 13 320 5 11 248 1 2 164 1 3 861 5 10 1062 5 10 1387 ~2.5 5 1124 ~2.5 4 336 <1 1 188 <1 1 232 Negative Control 0 0 110 Negative Control 0 0 124 5

RESULTS FROM LABORATORY 2: The first column indicates the actual dilution in the serial dilutions. The second column indicates the number of CFU in the side by side traditional culturing of the same dilution. The third column indicates the final reading on the fluorometer. Data Table for E. coli ATCC #8739 Dilutions Average Counts (CFU) Fluorometer Readings 10:10 ~29 2,490 9:10 ~22 1,991 8:10 ~19 2,211 7:10 ~15 2,220 6:10 ~14 2346 5:10 ~10 1,584 4:10 ~8 1,987 3:10 ~8 1,813 2:10 ~5 1,682 1:10 ~1 1,511 Neg. Control 0 122 Data Table for Pseudomonas aeruginosa ATCC #2097 Dilutions Average Counts (CFU) Fluorometer Readings 10:10 ~9 299 9:10 ~7 267 8:10 ~7 181 7:10 ~6 218 6:10 ~4 247 5:10 ~5 81 4:10 ~3 91 3:10 ~1 105 6

2:10 ~2 249 1:10 ~1 49 Neg. Control 0 8 Data Table for Klebsiella pneumoniae ATCC # 4352 Dilutions Average Counts (CFU) Fluorometer Readings 10:10 ~26 2,138 9:10 ~24 2,359 8:10 ~20 1,817 7:10 ~22 1,917 6:10 ~18 1,826 5:10 ~14 1,636 4:10 ~10 1,271 3:10 ~10 807 2:10 ~6 559 1:10 ~3 332 Neg. Control 0 22 ADDITIONAL NEGATIVE CONTROLS Negative Control Fluorometer Reading 1 118 2 141 3 38 4 127 5 50 6 190 7

INTERPRETATION OF RESULTS Based on the above independent laboratories results and Healthmark s internal testing, a numerical value greater than 300 strongly indicates the presence of more than 10 CFU of gram negative bacteria. If the readings are over 300, further steps including reprocessing and investigation of reprocessing procedures (perhaps involving Risk Management, Infection Control, etc.) should be undertaken. One of these steps may be culturing of the endoscope for bacterial contamination and species identification. A numerical value between 200 and 300 likely indicates the presence of Gram negative bacteria (but could be due to insufficient cooling of the cuvette or air bubbles in the cuvette). Reprocess the endoscope and retest, ensuring that sufficient time for cooling has occurred, according to the IFU, and that the mixing of Reagent A in the cuvettes is done gently to avoid air microbubbles in the solution. Other contaminants (such as loose debris) in the recaptured water can cause auto fluorescence. This also necessitates a reprocessing of the scope as such debris should not be present in a clean endoscope. DISCUSSION The importance of endoscope sampling cannot be undermined when keeping patient safety in mind. The need for endoscope sampling is especially pronounced if the facility has recently adopted a new cleaning or disinfection protocol, if there is a recent nosocomial outbreak that needs to be investigated or if a perfect quality assurance program is not in place in the facility. The innovative NOW! Test caters perfectly to these concerns and comes at a time when the awareness of these issues is on a steep rise. REFERENCES 8

Alfa, M.J., Olson, N., DeGagne, P. American Journal of Infection Control, 34(9), 561-570 (2006): Automated washing with the reliance endoscope processing system and its equivalence to optimal manual cleaning. Alfa MJ, Sitter DL. In-hospital evaluation of contamination of duodenoscopes: a quantitative assessment of the effect of drying. J Hosp Infect 1991; 19:89-98 Muscarella L.F., Infect Control Hosp Epidemiol. 2002 May; 23(5):285-9 9