INTRODUCTION 1. Contents

Similar documents
User Manual. CFG253 3 MHz Function Generator

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Arbitrary/Function Generators AFG3000C Series Datasheet

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

HP 33120A Function Generator / Arbitrary Waveform Generator

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

MAINTENANCE & ADJUSTMENT

FREQUENCY RESPONSE ANALYZERS

FG , 08501K, 08502K, 08503, 08503K, 08504K

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Annex: VISIR Remote Laboratory

AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014

PB-505. Advanced Analog & Digital Design Workstation Instruction Manual

XR-2206 Monolithic Function Generator

EFC Frequency converters

Step Response of RC Circuits

Voltech DC1000. Precision DC Bias Current Source

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

TOA 900 SERIES II MIXER POWER AMPLIFIER

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Multi-Range Programmable DC Power Supplies 9115 Series

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

PB-503. Analog & Digital Design Workstation Instruction Manual

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

A-145 LFO. 1. Introduction. doepfer System A LFO A-145

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

PCM Encoding and Decoding:

TUBE-TECH HLT 2A Stereo High- and Low shelving, T- filter & Low- and High cut

LM566C Voltage Controlled Oscillator

Agilent E5100A Network Analyzer

Hear The Future...Now! SIEM-2T/SIEM-2R

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

PicoScope 6000A/B Series

Lab 1: The Digital Oscilloscope

Multi-Range Programmable DC Power Supplies 9115 Series

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

Model 3390 Arbitrary Waveform Generator

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

Agilent 8904A Multifunction Synthesizer dc to 600 khz

Preset Counter signo 721

AutoRanging Digital MultiMeter

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

BXR 300C BXR 300R. Owner, s Manual P/N

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

15 Series - Electronic step relay and dimmer. Features SERIE

IMPORTANT SAFETY INSTRUCTIONS

Electrical Resonance

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

64-CHANNEL INTEGRATED AMPLIFIER

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

R&S ZNBT8 Vector Network Analyzer Specifications

PEBBLE USER MANUAL. MODEL: GMR1888DAB DAB Digital & FM Radio. Hyper-link ALL text to corresponding sections

Reading: HH Sections , (pgs , )

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

User s Guide. Publication number E June Copyright Agilent Technologies All Rights Reserved. E2697A 1 MΩ Impedance Adapter

Plena Loop Amplifier. Installation and User Instructions PLN-1LA10

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

1. SAFETY INFORMATION

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

Op-Amp Simulation EE/CS 5720/6720. Read Chapter 5 in Johns & Martin before you begin this assignment.

EXPERIMENT NUMBER 8 CAPACITOR CURRENT-VOLTAGE RELATIONSHIP

FREJA 300 Relay Testing System

LOXONE 12 Channel Amplifier

OPERATING MANUAL PUBLIC ADDRESS POWER AMPLIFIER PA-9336

Agilent U2761A USB Modular Function/Arbitrary Waveform Generator

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

MANUAL PC1000R

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

T Substation Maintenance and Commissioning Test Equipment

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

PC FUNCTION GENERATOR

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

DC Electronic Loads 8500 series

PERF10 Rubidium Atomic Clock

TESTER MMS FG-220 OPERATING INSTRUCTIONS. valid from 2/2015. Machine Monitoring Systems

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

DAB+ / FM Tuner Model: TU-201

LM1596 LM1496 Balanced Modulator-Demodulator

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Description. Dimensions. Features. precision works better

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

User s Manual Before using the inverter, you need to read and save the safety instructions.

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Model UT60A: OPERATING MANUAL. Table of Contents. Page

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers

PHYSICS LAB #2 Passive Low-pass and High-pass Filter Circuits and Integrator and Differentiator Circuits

Transcription:

INTRODUCTION Thank you for buying SG1634N&SG1638N series function generator/counter. Please read this manual carefully before operation and keep it well. Suggest to use an oscilloscope to watch the waveform when operation. In order to ensure the product s specification, please use it in stated working condition. Please contact with our market department or service center if there s something wrong with the instrument, you ll get efficient help. Safe warning Instrument s AC power supply should be fit for the given request (AC220V±10% 50Hz /110V±10% 60Hz switchable) Please select the real input voltage by the voltage selector Instrument s AC power supply should have safe GND. Changing fuse should be fit for given request. Each output, input port should not contact AC power supply. Each output, input port should not contact over ±35V AC or DC power. Output port should try to avoid long-time short circuit. ( 1m) In order to ensure instrument s accuracy, please avoid strong magnetoelectricity. Contents INTRODUCTION 1 1. Description 2 2. Technical Specifications 2 Main output 2 TTL/CMOS output 3 Frequency counter 3 Power 3 Physical characteristics 3 Environment condition 4 3. Operation 4 4. Panel operation Summary 5 5. Basic operation methods 8 6. Instrument accessories 8-1 -

1. Description SG1634N&SG1638N series function generator/counter is a new-type high accuracy function generator. It is new, beautiful panel and easily operation. It has the function of frequency display/ counter display (SG1638N). Each port has protection function, efficiently prevent the damage by output short circuit and out circuit current devise. And all that improves the instrument s liability. The instrument can be used for experiments or inspections in factories, schools or scientific researches and so on. Main characters: Multi waveforms: sine, triangle, square, ramp, pulse and etc. Separate TTL, 50Hz sine and single output. DC offset and symmetry continuously adjustable. VCF input. Built-in 6 digits counter up to 30MHz equal accuracy (SG1638N). 2. Specifications: 2.1 Main output: Model SG1634N SG1638N Output frequency 0.2Hz~2MHz Frequency step six-step, decimalism Frequency adjustment ratio Rate: 0.1~1 Range: 0.2~2 Output waves sine square triangle pulse ramp and 50Hz sine Output impedance 50Ω±10% Output signal type single VCF VCF 0~5V VCF 100:1 External FM voltage 0~3Vp-p Output amplitude 20Vp-p (1MΩ) 10Vp-p (50Ω) Output protection short circuit, resist input voltage: ±35V (1M) Distortion of sine 100k 2% waves >100k 30dB Frequency response 100KHz ±0.5dB > 100KHz±1dB - 2 -

Linearity of triangle wave Duty adjustment DC offset Rising time of square wave Attenuation accuracy Effect of duty on frequency 50Hz sine output 100kHz : 98% >100kHz : 95% 20%~80% ±10V (1MΩ) ±5V (50Ω) 100ns 5Vp-p 1MHz ±3% ±10% About 2Vp-p 2.2 TTL/CMOS out Model SG1634N SG1638N Output amplitude 0 : 0.6V; 1 : 2.8V Output impedance 600Ω Output protect Short circuit, resist input voltage: ±35V (1M) 2.3Frequency counter: Model SG1634N SG1638N Measurement accuracy --- 6digits±1% ±1word Resolution --- 0.1Hz Gate time --- 10s ( 8kHz) 1s (8kHz to 200kHz) 0.1s (200kHz to 15MHz ) Ext measurement frequency range --- 1Hz~15MHz Ext measurement frequency sensitivity --- 200mV Range of counter --- 6(999999) 2.4 Power: Voltage: 220±10%V /110±10%V (Switchable) Frequency: 50±2Hz/60±2Hz Visual power: 10VA prox.; Fuse: 0.5A - 3 -

2.5 Physical characteristics: Weight: Appro. 3kg Dimensions: 225(W) 105(H) 285(D)(mm) 2.6 Environment conditions: Working temperature: 0~40ºC Storage temperature: -40~60ºC Max working humidity: 90%(40ºC) Max storage humidity: 90%(50ºC) Other demands: continually vibrate and impact should be avoided. No acid alkali and hydrochloric air 3. Operation: 3.1 Working environment and power should be agreeable with the given demands in the specification. 3.2 The instrument should be put in the place where is ventilative and dry for several hours and turn on for 1-2 hours, then it can be used if it is used the fist time or storage for a long time. 3.3 In order to get super-quality small signal (mv) please put the switch of EXT measurement on EXT to reduce the disturbance of the wave of digital signal. 3.4 Please choice high measurement range first when use external measurement, then choice appropriate measurement range according to the measurement value to ensure measurement accuracy. 3.5 Voltage output amplitude TTL/CMOS output should try to avoid long-time short circuit or current devise. 3.6 Each input terminal or input voltage should not be over ±35V 3.7 In order to watch correct function wave, oscilloscope s belt width should be twice times than maximum frequency on this instrument. 3.8 If the instrument can not work normally, check the operating procedures again. It is certain that there is something wrong with the machine, please contact with the nearest service center. - 4 -

4. Panel operation Summary: SG1634N Function Generator Front Panel SG1638N Function Generator Front Panel SG1634N&SG1638N Function Generator Back Panel - 5 -

(1) Power: spring out means off. Connect the power line. Push down the knob and power is on. (2) LED window: this window indicates the frequency of output signal, when EXT is on, it displays frequency of external signal. If over the measurement range, the light overflow is on. (3) Frequency: adjust this rotary to change output frequency signal, the frequency will be big while turn it clockwise. (4) Wave form: choose the wave you need if you press the correspondence key. (5) ATTE: The voltage output attenuate switch, two-switch combination is 20db, 40db, 60db. (6) Frequency range selector: (frequency counter gate switch): Press one key according the needed frequency. (7) Counter/Frequency terminal: Counter, EXT frequency input terminal. (8) EXT frequency switch: Press this switch, LED window will display EXT signal frequency or counter value. (9) Level adjustment: Press level adjustment switch, the light level is on, then adjusting level adjustment rotary can change DC level offset. (10) Amplitude: The voltage output amplitude will be big while turning it clockwise, and the value will be small while turning it counterclockwise. (11) Voltage out: voltage is out via this terminal. (12) TTL/CMOS out: TTL/CMOS is out via this terminal. (13) VCF: Voltage controlling frequency change input is via this terminal. (14) SYMMETRY: sym switch, duty adjustable rotary, press duty switch, the light SYM is on; adjusting duty rotary can change the duty of wave. (15) 50Hz sine output: 50Hz about 2Vp-p sine wave deliver via this terminal. (16) Press the switch: 50Hz sine out (17) Single sine output (18) Press the switch: single sine output (19) 110V/220V voltage selector (20) AC 220V input socket. - 6 -

5. BASIC OPERATION METHODS: Before power is on, fist check the input voltage, insert the power line into the AC socket in the rear panel. Set each controlling knob as the following table: POWER Knob ATTE Knob COUNTER Knob LEVEL Knob SWEEP Knob DUTY Knob After that, turn on the switch. The function signal generator acquiesce 10k sine wave, LED window display it s out signal frequency. 5.1 Deliver the voltage out signal to oscilloscope Y input terminal via amplitude terminal. 5.2 Triangle square sine wave form: 5.2.1 Press sine square triangle wave, the screen of oscilloscope will display sine square and triangle. 5.2.2 Press frequency range selector and rotate the frequency rotation, the waveform on the oscilloscope s screen and frequency on LED window will change evidently. 5.2.3 Turn the amplitude rotary to maximum, the wave amplitude on the oscilloscope s screen will be 20Vp-p 5.2.4 Press LEVEL, turn the level rotary to max, wave on oscilloscope will move upside, and vise visa. The max change should be ±10V or more. NOTICE: when signal is over ±10V or ±5V (50Ω),the amplitude is limited. 5.2.5 Press ATTE, the out waveform will be attenuated. 5.3 COUNTER. 5.3.1 Press COUNTER, when the counter/frequency input terminal input signal, LED display begin to counter. 5.3.2 Choose agreeable frequency range; choose the agreeable and efficient digits from high measurement range to low measurement range. Ensure the measurement accuracy. (NOTICE: when the light overflow is on, please advance one measurement range.) The count should be measured based on the frequency of stalls suitable choice. 10s (20, 200, 2 k), 1s (20k, 200k), 0.1s (2M) 5.4 RAMP: 5.4.1 Put the wave switch on TRIANGLE. 5.4.2 Press DUTY, the indicator is on. 5.4.3 Adjusting the duty rotary, the triangle wave will change Ramp wave. - 7 -

5.5 TTL OUT: 5.5.1 TTL/CMOS connect with oscilloscope s Y axis input terminal (DC input) 5.5.2 Oscilloscope will display square wave or pulse wave, it can be used as clock signal generator on TTL/CMOS digital circuit experiment. 5.6 VCF: Input 0~5V AM signal via VCF input terminal, and the output signal controls by voltage. 5.8 50Hz sine wave: Output 50Hz about 2Vp-p sine wave via AC output terminal. 5.9 Single sine output: output 0~4.5V single pulse 6. INSTRUMENT ACCESSORIES: The standard accessories are as following: (1) Function Signal Generator 1 set (2) Connect cable 1 piece (3) Operation manual 1copy (4) Fuse 1piece (5) Power cord 1piece - 8 -