TIG PAK 200(A) (TIG PAK 2112, 2112A, 2125, 2125A)

Similar documents
USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Square Wave TIG 200 TIG WELDING MACHINE

A Beginner s Guide to TIG Welding

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

TITAN 13 x 2 ½ BRAKES

Advantium 2 Plus Alarm

Digital Fingerprint safe

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

MODEL G300 BRAKE BLEEDER

MP-4V Heavy Duty Riveter / 39048

Model SRMD Setra Remote Monitoring Display

UNI FLAME AUTOLIFT MIG/MMA/TIG. 165/190/220/250 Inverter Manual. 240 Volt. Standard MIG / MAG

PAINT SPRAY GUN WASHER

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

ELECTRIC KNIFE SHARPENER

TIG WELDING TIPS by Tom Bell

AN INTRODUCTION TO TIG WELDING. wws group

16/32 Channel 1U Rack Mount CCTV Power Supply

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

OAK WORKBENCH WITH 2 DRAWERS

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

12-Volt Negative Ground Installation Instructions

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Utility Distribution Systems

4 in 1 Air Compressor

Hydraulic Transmission Jacks Operating Instructions & Parts Manual

FLEX by 3M Light Module System

IR Repeater. Operation Manual P8620

120Volt 60-70A ARC WELDER Rev

Owner s Manual & Safety Instructions

LIFT N RACK PRO OPERATING & INSTALLATION GUIDE 5500 Lb. LIFT CAPACITY

PARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS

INSTALLATION GUIDE. APPLICATION LENGTH MODEL YR PART # Bestop PART #

Installation and Operation Guide for PD5100 Automatic Transfer Switch

4-in-1 SWIVEL TABLE. 54in (1.37m) CONTACT INFO Hours. Technical Support Monday to Friday (9:00am to 5pm EST) WARNING:

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part #

HYDRAULIC TABLE CART

Water Leak Detection System

WH/WIH/WIHD/WIHD&M/WIHL AND WIH SERIES

OPERATORS MANUAL MG22 MEAT GRINDER MG22/0209 ED

Installation Instructions

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Chapter 5 - Aircraft Welding

VK-250 WARRANTY REGISTRATION FORM

ROUTER TABLE INSERT ASSEMBLY AND OPERATING INSTRUCTIONS

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

INSTALLER S & OWNER S MANUAL

North Carolina FFA Association Agricultural Mechanics Career Development Event

Mini-led spotlight with magnetic base

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

TORCH SYSTEM PAGE PT-15 /PT-15XL PCM-8,ESP-300,ESP-400,ESP-600,ESP ,3 PT-19XLS /PT-19XL ESP-200/300/400/600/1000,PCM8XL,PCM150/

Master Prep Professional

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

WORD DEFINITION WORD (NATIONAL LANGUAGE)

PNEUMATIC PLANISHING HAMMER

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

ROTOR LOADER OWNER S MANUAL

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Float and Thermostatic Traps Series H, C and X

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

8 ton air/hydraulic long ram jack

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

Operation Manual. Made in the U.S.A. For questions or concerns with this unit, please call DO NOT return this antenna to your dealer.

Table of Contents WARNING SYMBOLS AND DEFINITIONS

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

CutMaster Major External Replacement Parts

Deluxe Welding Tool Chest

ATS Overhead Table Shelf System INSTRUCTION MANUAL

PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790


Installation and Operating Instructions (for chargers shown below)

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

MDT5N25 & MTD5N40 SERVICE PARTS

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

SMD Rework Station TABLE OF CONTENTS

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

CutMaster Major External Replacement Parts

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

MAC FAUCETS. Owner s Manual. Models: FA444

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

TIG torches to 3-5 Tungsten electrodes to 3-7 TIG consumables Miscellaneous

STC 3S A Series Solenoid Valves

Installation and Operating Instruction Manual

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

TTL to RS232 Adapter User Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW


Installation and Operating Instructions (for chargers shown below)

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

Transcription:

TIG PAK 200(A) (TIG PAK 2112, 2112A, 2125, 2125A) OWNERS MANUAL THE TIG PAK 200(A) ENABLES THE OPERATOR TO PERFORM HIGH QUALITY TUNGSTEN-INERT GAS (T.I.G.) WELDING ON STEEL, STAINLESS STEEL, CHROME-MOLY, COP- PER AND CAST IRON. THIS T.I.G. WELDING PACKAGE WILL NOT WELD ALUMINUM. FOR TECH. SERVICE, CALL 1-800-222-9353 INSTALLATION OPERATION REPLACEMENT PARTS FORM WC5228 Rev. 1/99, 1/01

MANUFACTURER S LIMITED WARRANTY This equipment is warranted against defects in materials and workmanship for a period of 90 DAYS from the date of purchase. Should it become defective for such reason, the Manufacturer will repair it without charge, if it is returned to the Manufacturer s factory, freight prepaid. This warranty does not cover: (1) failure due to normal wear and tear; (2) consumable parts, such as, but not limited to, collets, collet bodies, gas cups and heat shields; (3) damage by accident, force majeure, improper use, neglect, unauthorized repair or alteration; (4) anyone other than the original purchaser. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY INJURY TO PERSONS, INCLUDING DEATH; OR LOSS OR DAMAGE TO ANY PROPERTY, DIRECT OR CON- SEQUENTIAL, INCLUDING, BUT NOT LIMITED TO, LOSS OF USE, ARISING OUT OF THE USE, OR THE INABILITY TO USE, THE PRODUCT. THE USER AS- SUMES ALL RISK AND LIABILITY WHATSOEVER IN CONNECTION WITH THE USE OF THE PRODUCT, AND BEFORE DOING SO, SHALL DETERMINE ITS SUITABILITY FOR HIS INTENDED USE, AND SHALL ASCERTAIN THE PROPER METHOD OF USING IT. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, OR THE EXCLUSIONS OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. SO THE ABOVE LIMI- TATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE. TABLE OF CONTENTS INTRODUCTION... 1 CONTENTS... 1 SPECIFICATIONS... 2 INSTALLATION... 2 INSTALLATION TIG PAK 200 (2112, 2125)... 3 INSTALLATION TIG PAK 200A (2112A, 2125A)... 4 OPERATION... 5 SCHEMATIC DIAGRAM... 5 PARTS BREAKDOWN... 6

INTRODUCTION The TIG Welding process is used to produce the highest quality, porosity-free welds. The TIG PAK 200(A) adds this capability to your MIG Welder. The TIG PAK 200(A) enables the operator to perform high quality Tungsten-Inert Gas (T.I.G.) welding on steel, stainless steel, chrome-moly, copper and cast iron. With Direct Current-Straight polarity (DCSP), the TIG PAK 200(A) will perform on the VOLTAGE settings 1 thru 4 (see welder output chart and warning on page 4). The settings are for use on materials ranging in thickness from 12 Ga. Min.(.105") thru 1/4" Max. The TIG PAK 200(A) consists of a 200 amp gas cooled torch with built-in gas control valve, remote On/Off switch, 12 1/2 or 25 foot cable assembly and the required consumable parts. CONTENTS 1- TIG Torch with built-in valve 1- Locking Electric Switch with 14 foot cord (installed on torch) 1-12-1/2 foot Power Cable with Connector (installed on torch) 1-15 foot Gas Hose with fitting (installed on torch) 3-3C332 Collet - for 3/32" tungsten 3-3C418 Collet - for 1/8" tungsten 2-3CB332 Collet Body - for 3/32" tungsten 2-3CB418 Collet Body - for 1/8" tungsten 2-3C6 Gas Cup - 3/8" orifice 6-3C7 Gas Cup - 7/16" orifice 2-3C8 Gas Cup - 1/2" orifice NOTE: THIS T.I.G. WELDING PACKAGE WILL NOT WELD ALUMINUM. 1-300L Long Backcap 3-3/32" X 3" Tungsten Electrode 3-1/8" X 3" Tungsten Electrode 1

SPECIFICATIONS PART NUMBER: TIG PAK 2112, 2125, TIG PAK 2112A, 2125A TORCH RATING: 200 Amps, DCSP DUTY CYCLE: 100% (reduce duty cycle when operating over 200 amps.) COOLING METHOD: Gas (100% Argon) SHIELDING GAS CONTROL METHOD: Gas Valve on Torch WELD CURRENT ON-OFF CONTROL: Locking Switch on Torch INSTALLATION TUNGSTEN PREPARATION NOTE Before using the TIG PAK 200(A) the tungsten electrode must be prepped. 1. Referring to Figure 1, grind the electrode following the IDEAL VIEW. TORCH HEAD ASSEMBLY 1. Select the size tungsten electrode to be used. 2. Make sure teflon heatshield is in place. 3. Locate the matching size Collet and Collet body. 4. Drop the Collet, slit-end down, into the Collet body. 5. Screw assembly into torch head, Heatshield side, and tighten firmly. 6. Install a Gas cup, screw into place seating cup against teflon heatshield. 7. Insert tungsten electrode, prepped end first, thru torch head, Collet and center hole of Collet body. 8. Allow tungsten electrode to extend pass the cup 1/8". 9. Screw Backcap into torch head, tighten firmly. ARC WANDER GAS CUP COLLET BODY POINT HEAT- SHIELD RADIAL GROUND COLLET WRONG VIEW STABLE ARC TORCH HEAD TUNGSTEN ELECTRODE BACKCAP STRAIGHT GROUND FLAT (the Dia. of this flat governs Amperage Capacity) IDEAL VIEW FIG. 1. TUNGSTEN PREPARATION FIG. 2. TORCH HEAD ASSEMBLY 2

INSTALLATION (Cont.) TIG PAK 200(2112) INSTALLATION 1. Remove the MIG torch assembly from the machine. 2. Unplug the Torch selector cable and the Work cable from the MIG welders front panel. 3. Plug the TIG torch power cable into "WORK" (-) terminal. 4. Plug the Work cable into "TORCH" (+) terminal. With the TIG torch and Work cable connected in this manner, straight polarity(dcsp) current is available as required for TIG welding. 5. Plug the TIG torch switch cord pins into the two (2) brass sockets found in the torch receptacle. 6. Attach the gas regulator/flowmeter to a cylinder of 100% pure Argon gas. 7. Attach the TIG torch gas hose directly to the gas regulator/ flowmeter. 8. Turn on the gas cylinder and open the TIG torch gas valve to purge the system of impurities in the gas line. Purge for one minute to ensure porosity free welds. YOU ARE NOW READY TO TIG WELD! GAS HOSE TO REGULATOR/ FLOWMETER GAS VALVE SWITCH CORD TO TORCH RECEPTACLE 100% ARGON GAS TIG TORCH LOCKING SWITCH (WORK CABLE PLUGS INTO POSITIVE (+) TERMINAL) POWER CABLE TO WORK (-) TERMINAL FIG. 3. TIG PAK 200 INSTALLATION PROCEDURES 3

INSTALLATION (Cont.) TIG PAK 200A(2112A) INSTALLATION 1. Unplug the wire feed motor plug from the Function receptacle. 2. Unplug the Torch selector cable and the Work cable from the MIG welders front panel. 3. Plug the TIG torch power cable into "WORK" (-) terminal. 4. Plug the Work cable into "TORCH" (+) terminal. With the TIG torch and Work cable connected in this manner, straight polarity(dcsp) current is available as required for TIG welding. 5. Plug the TIG torch switch cord into function plug receptacle. 6. Attach the gas regulator/flowmeter to a cylinder of 100% pure Argon gas. 7. Attach the TIG torch gas hose directly to the gas regulator/ flowmeter. 8. Turn on the gas cylinder and open the TIG torch gas valve to purge the system of impurities in the gas line. Purge for one minute to ensure porosity free welds. YOU ARE NOW READY TO TIG WELD! TIG TORCH GAS VALVE GAS HOSE TO REGULATOR/ SWITCH CORD FLOWMETER TO WELDER FUNCTION RECEPTACLE 100% ARGON LOCKING SWITCH FUNCTION RECEPTACLE GAS POWER CABLE TO WORK (-) TERMINAL (WORK CABLE PLUGS INTO POSITIVE (+) TERMINAL) FIG. 4. TIG PAK 200A INSTALLATION PROCEDURES 4

OPERATION 1. Open the TIG torch gas valve. 2. Set the flowmeter @ a 20 CFH flow rate. 3. Turn "On" the MIG welding machine. 4. Set the welder Voltage control switch to the desire setting. See "Welder Output Chart"and Warning that follows. WELDER OUTPUT CHART - FOR TIG WELDING HEAT SETTING OUTPUT(Approx.) 1 155 AMPS 2 190 AMPS 3 200 AMPS 4 210 AMPS 5 230 AMPS 5. Depress the TIG torch switch and lock "On", scratch or touch tungsten to the work and draw back to establish an arc. CAUTION Continual sticking of the tungsten electrode to the work surface can cause severe damage to the MIG welding machine. 6. Once arc is established, hold and maintain a steady arc until base material becomes fluid. Then continue welding while maintaining a consistent arc length and travel speed. DIRECTION OF TRAVEL WARNING THE TIG PACKAGE IS RATED UP TO 200 AMPS, @ A 100 % DUTY CYCLE. OPERATION ABOVE VOLTAGE SETTING #4 COULD RESULT IN PERMANENT DAMAGE TO THE TORCH HEAD AND CABLES. WORK FIG. 5. TIG WELDING ILLUSTRATION COM. RED 5 5 YELLOW N.O. BLACK 6 6 YELLOW ON/OFF SWITCH FUNCTION PLUG ASSEMBLY FUNCTION RECEPTACLE ASSEMBLY (AD-02) FIGURE 6. SCHEMATIC DIAGRAM 5

REPLACEMENT PARTS - TIG TORCH ASSEMBLY 3C6 3C7 3C8 3CB332 3CB418 3C332 3C418 300HS CK210V SW2 300S 300L VK 210HE 412PC-200A 425PC-200A {SN-170A 412CN-200A 425CN-200A 3HF SN-168A SN-520 SN-169A 312AH 325AH M3-903B SN-861C AD-02 SN-860C { SN-862 SN-863 SC12-200 SC25-200 SN-860C { SN-862 SN-863 SC12-200A SC25-200A 6

REPLACEMENT PARTS - TIG TORCH ASSEMBLY (Cont.) PART MODEL NO. NO. DESCRIPTION 210HE ALL HANDLE (only) 300HS " HEATSHIELD 300L " LONG BACKCAP (with "o" ring) 300S " SHORT BACKCAP (with "o" ring) 312AH TP2112, 2112A GAS HOSE (only) - with fittings, 12 1/2' 325AH TP2125, 2125A GAS HOSE (only) - with fittings, 25' 3C332 ALL COLLET, 3/32" 3C418 " COLLET, 1/8" 3C6 " CUP, 3/8" ORIFICE 3C7 " CUP, 7/16" ORIFICE 3C8 " CUP, 1/2" ORIFICE 3CB332 " COLLET BODY, 3/32" 3CB418 " COLLET BODY, 1/8" 3HF " FITTING, GAS HOSE 412CN-200A TP2112, 2112A POWER CABLE (only) - with fittings, 12 1/2' 425CN-200A TP2125, 2125A POWER CABLE (only) - with fittings, 25' 412PC-200A TP2112, 2112A POWER CABLE AND HOSE ASSEMBLY, 12 1/2' 425PC-200A TP2125, 2125A POWER CABLE AND HOSE ASSEMBLY, 25' AD-02 TP2112, 2125 ADAPTER, CONTROL WIRE (only) CK210V ALL TORCH BODY (only) - with valve assembly & heatshield M3-903B TP2112, 2125 TERMINALS, ROUND SC12-200 TP2112 CONTROL WIRE (only) - with fittings, 12 1/2' SC25-200 TP2125 CONTROL WIRE (only) - with fittings, 25' SC12-200A TP2112A CONTROL WIRE (only) - with fittings, 12 1/2' SC25-200A TP2125A CONTROL WIRE (only) - with fittings, 25' SN-168A ALL CABLE TERMINAL (only) SN-169A " TERMINAL INSULATOR (only) SN-170A " CABLE TERMINAL ASSEMBLY (only) SN-520 " HOSE NUT SN-860C " FUNCTION PLUG ASSEMBLY (only) SN-861C 2112, 2125 FUNCTION RECEPTACLE ASSEMBLY (only) SN-862 ALL STRAIN RELIEF AND SCREW SN-863 " GROMMET SW2 " LOCKING ELECTRIC SWITCH (only) VK " VALVE (with "o" rings) 7

8 NOTES:

NOTES: 9