4âÓ RIA250. Technical Information

Similar documents
Technical Information RIA14

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Safety technique. Emergency stop module BO 5988 safemaster

Panel Meters and Controllers Modular Panel Meter Type EDM 35

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Electronic Control Devices The European Product Catalogue 2007

Liquid Level Limit Switch liquiphant T FTL 20

3DLevelScanner II TECHNICAL DATA SHEET

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Electronic Control Devices The European Product Catalogue 2007

15 Series - Electronic step relay and dimmer. Features SERIE

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Short information Parameters are programmed via front-side membrane keypad

Analog signal converters CC-E I/I Current / current isolators

Operating instructions. itemp PCP TMT181. Temperature head transmitter. BA100R/24/ae/

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Digital input modules

Telephone- and leased line modem for industrial applications TD-36

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Quick Connect. quick - simple - efficient.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Regards from the Team at Rheology Solutions.

38 Series - Relay interface modules A

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Preset Counter signo 721

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

38 Series - Relay interface modules A

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

80 Series - Modular timers 16 A. Features

Technical Data Sheet. 3DLevelScanner

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Duct Humidity Transmitter

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Energy Management Energy Meter Type EM23 DIN

Three-phase monitoring relay CM-PFE

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

DC Electronic Loads 8500 series

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Contents. Document information

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

NEW. EVEN MORE data acquisition and test stand automation

Multifunction devices

TX OPEN RS232/485 module

How To Use A Ds340 (Dsp)

40.3. Control Relays and Timers

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

RM4TG20 three-phase network control relay RM4-T - range V

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Rack mounted telephone- and leased line modem for industrial applications

WD-AMX Water Detection Controllers

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

48 SERIES Relay interface modules 10 A

TMS TANK MANAGEMENT SYSTEM

Inductive sensor NI10-M18-Y1X-H1141

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

OZW30. Central Unit SYNERGYR

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Transcription:

Technical Information RIA250 Process display Multifunctional 1 channel display with universal input, loop power supply, limit monitor and analog output Application Benefits at a glance All normal measurement signals can be directly connected (bipolar voltage and current, thermocouple, RTD) Active numeric measured value display with bar graph Flexible set point monitor with 2 relay contacts Adjustable current or voltage analog output Integrated loop power supply for connected sensors RS232 interface for setup configuration and measured value output Certification: Plant and machine construction Control panels Laboratory fittings Temperature display and monitoring Process display and monitoring Process control Signal match and transforming 4âÓ TI060R/24/ae

Function and system design Measuring principle Measuring system Transmitter The display receives an analog signal and shows the corresponding value on the display. The analog output transmits this displayed value either as a current or voltage. Two presettable limit values monitor the measured value for any infringement of the preset conditions and control the two output relays. Transmitters connected are directly powered by the unit. The presettable universal input enables direct connection of various sensors, whether current, voltage, RTD or thermocouple. Using the built-in loop power supply the unit can also power the connected sensors and then evaluate the signal returning from the sensor to the input of the unit. Two presettable set points monitor the measured value for any deviation from the preset conditions. This opens up a number of possibilities for direct process control. The scaleable analog output offers an instrument from which a matched signal for further analysis equipment can be obtained. Simple setting up using an interface and PC program as well as manual on site setting up are available. Using the linearization function and the analog output, the RIA250 process display can also be applied as an easy-to-use amplifier. The large number of already stored temperature linearization tables as well as a square root function can be easily selected from the setup menu. Example: The signal from a temperature sensor is connected to the input of the unit, then linearized and displayed as a temperature value. The analog output is made available to other instrumentation (e.g. data loggers or recorders) as a current or voltage signal proportional to the displayed value. Linearization Limit function Up to 32 points maximum. The RIA250 display has a built-in linearization function. It is possible for the user to set up a connection between the input signal and the value to be displayed on the unit. These points can be set up using the three front mounted push buttons, or they can be easily defined and transmitted using the ReadWin 2000 operator software. Example: Linearization of a tank signal that describes the relationship between the filling height and the tank volume. The additional limit function monitors the measured signal once per second in order to see that the preset parameters have been adhered to. Both limits can be individually set up for minimum or maximum security, as a high or low limit with presettable hysteresis as well as being able to define a switch time delay. The set point infringement is indicated using 2 LEDs, as an option, an output relay can be activated. 2 Endress+Hauser

Input Measured variable Voltage, current, resistance thermometer (RTD), thermocouple (TC) Measuring range Voltage Current RTD Thermocouple +/-100mV; max. +/-5V, +/-10V; max. +/-50V R i : 1MΩ 0/4...20mA; max. 200mA; R i : 5Ω Pt100, -200 to +850 C (-328 to +1652 F), DIN EN60751) Ni100, -60 to +180 C (-76 to +356 F, DIN 43760) Sensor current, approximately 250 μa, pulsed Connection: 2 wire, 3-wire, 4-wire Cable compensation, 40Ω Type T, -270 to +400 C (-454 to +752 F) Type J, -210 to +1200 C (-346 to +2192 F) Type K, -200 to +1372 C (-328 to +2502 F) Type R, -50 to +1800 C (-58 to +3272 F) Type S, 0 to 1800 C (32 to 3272 F) Type B, 0 to 1820 C (32 to 3308 F) Type N, -270 to +1300 C (-454 to +2372 F) Type U, -200 to +600 C (-328 to +1112 F) Type L, -200 to +900 C (-328 to +1652 F) Type W3, 0 to 2315 C (+32 to +4199 F) Type W5, 0 to 2315 C (32 to 4199 F) Type T, J, K, R, S, B, N to DIN EN60584 Type U, L to DIN 43710; Type W3, W5 to ASTME988-96 Integration time 1 s Output Loop power supply 24 V, ± 20%, 30 ma Number of outputs 1 Galvanic isolation Optional analog output To all other current circuits. The RIA250 display can be fitted with an analog output (optional). The output signal is proportional to the displayed measured value and the bar graph displays the input signal position. Special features: Current/Voltage output Galvanic isolation Infinite scaling within the display range Presettable fault operation to NAMUR recommendation NE43 Output signal 0/4 to 20 ma, 20 to 4/0 ma or 0 to 10 V, ± 10% over range Voltage Output current maximum, 20 ma Current Load maximum 500Ω Fault message Presettable 3.6 ma or 21 ma. Actions to NAMUR recommendation NE43 D/A resolution Endress+Hauser 3

Current; 13 bit; voltage, 15 bit Number of outputs 1 Galvanic isolation To all other current circuits Optional relay output Output signal Binary, switches when set point is reached Number of relays 2 Contact type DPDT Contact load < maximum 250 VAC, 5A Electrical connection Electrical connection Terminal assignment RIA250 4 Endress+Hauser

Supply voltage Power consumption 90...250 VAC, 50/60 Hz Optional: 18...36 VDC, 20...28 VAC 50/60Hz 11,5 VA (90...250 VAC) 5,5 VA (18...36 VDC; 20-28 VAC) Performance characteristics Accuracy Voltage Current 0.05% of end value Temperature drift, 0.01% / 10K ambient temperature 0.05% of end value Temperature drift, 0.01% / 10K ambient temperature RTD 2-wire, ± 0.8 C (± 1.4 F) 3-wire, 4-wire, ± 0.5 C (± 0.9 F) ± 0.3 C (± 0.5 F) Temperature drift, 0.01% / 10K ambient temperature Thermocouple Type T: ± 0.2 C (± 0.4 F); T < -150 C, ± 1.0 C (T < -238 F) Type J: Type K: Type R: Type S: Type N: Type B: Type U: Type L: Type W3: Type W5: ± 0.2 C (± 0.4 F); T < -150 C, ± 1.0 C (T < -238 F) T > 400 C, ± 1.0 C (T > 752 F, ± 1.8 F) ± 0.5 C (± 0.9 F) ± 0.5 C (± 0.9 F) Temperature drift, 0.01% / 10K ambient temperature Analog output 0.04% of end value Temperature drift, 0.05% / 10K ambient temperature Thermocouple cold junction ± 0.5 C (± 0.9 F) Resolution, 0.1 C (0.2 F) Endress+Hauser 5

Installation Installation instructions Mounting location Panel cutout 48 x 96 mm (1.89 x 3.78 inches), see 'Mechanical construction'. Installation angle No restrictions. Environment Ambient temperature -10 to +50 C (15 to 120 F) Storage temperature -30 to +70 C (-20 to +155 F) Climatic class To EN 60654-1 Class B2 Ingress Protection NEMA 4x, IP 65 front; NEMA 1, IP 20 for terminals RFI protection Normal safety To EN 55011 Group 1, Class A To EN 61010-1 protection Class 1, over voltage category II, installation over current protection < 10 A Altitude Up to 2000 m (6560 ft.) above sea level according to IEC 61010-1, EN 61010-1, CSA 1010.1-92 ESD Electromagnetic fields Burst (supply) Burst (signal) Surge (AC supply) Surge (DC supply) Cable high frequency Common mode noise rejection Normal mode noise rejection To EN 61000-4-2, 6kV/8kV To EN 61000-4-3, 10V/m To EN 61000-4-4, 4 kv To EN 61000-4-4, 4 kv To EN 61000-4-5, sym. 1 kv, unsym. 2 kv To EN 61000-4-5, sym. 0.5 kv, unsym. 1 kv To EN 61000-4-6, 10 V 80 db at 60 V, 50/60 Hz 60 db at input range 1/10, 50/60 Hz 6 Endress+Hauser

Mechanical construction Design, dimensions Dimensions of the RIA251 Weight Material Electrical connection approximately 600 g (1.32 lbs) Housing front: Die cast aluminium Housing casing: Galvanized sheet steel Housing rear panel: Plastic ABS Plug on screw terminals, 1.5 mm 2 (16 AWG) solid, 1.0 mm 2 (18 AWG) stranded with ferrule Human interface Display and operating elements Display and operating elements RIA250 1) Alarm limit indicators 2) 5-digit LED display 3) 12-segment LED bargraph display 4) Selection push buttons 5) Enter push button Endress+Hauser 7

Display 5-digit LED, 13 mm (0.5") character height, rear illuminated. Bargraph display in 10% increments, markers for over/under range display. Range -199999 to +99999 Offset -199999 to +32767 Signals Measurement range over/under value Rear illumination Illumination brightness increases with an increase in loop current Operation Interface 3 push button operation (-/+/E), integrated in the unit, access when unit is opened RS232, connects to rear panel, 3.5 mm stereo connection. The RIA250 can be set up extremely easily using the built-in RS232 serial interface and the Endress+Hauser ReadWin 2000 PC software. Safe and secure setup is made possible via on-line help text. ReadWin 2000 software and interface cable are optionally available. Special features: Compatible with Windows 95/98/2000/NT/XP/CE PC operating system Storage of unit settings in a data bank Instantaneous value display Printout of unit settings Certificates and approvals CE GL approval By attaching the CE mark, Endress+Hauser confirms that the instrument fulfills all the requirements of the relevant EC directives (89/336/EWG) Certification for GL-Germanischer Lloyd marine approval UL Recognized component to UL 3111-1 CSA CSA General purpose 8 Endress+Hauser

Ordering information Product structure RIA250 Electronical indicator. 1 channel, scalable. Trend indication, limit marker yellow. Loop power supply 24VDC, 30mA. Interface RS232, ReadWin 2000. Approval: GL (German Llyod) Marine. UL listed + CSA GP. Linearization table 32-point. Approval A Non-hazardous area Power supply 1 90-250VAC 2 18-36VDC, 20-28VAC Measuring signal 1 0/4-20mA, +/-100mV, +/-10V Thermocouple, Pt100, Ni100 Display R 5-digit LED, red G 5-digit LED, green Output 1 Not selected 2 2x relay limit DPDT 3 Analog 0/4-20mA / 0-10V + 2x relay, Limit DPDT Housing 1 Panel mounting, 48x96x150mm 2 Panel mounting, 48x96x150mm + WCC=Works calib. certif. 3 Field housing, IP65 204x155x215mm 4 Field housing, IP65 204x155x215mm + WCC=Works calib. certif. J Standard model Japan, panel mounting, 48x96x150mm Marking 1 Tagging (TAG), on nameplate 2 Tagging (TAG), metal 5 Tagging (TAG), paper RIA250- A Order code Documentation System components - field and panel installation display unit, energy manager, active barrier, process transmitter and overvoltage protection: FA016K/09 Operating instructions Process display RIA250 : BA107R/09 Endress+Hauser 9

USA Canada México Instruments International Endress+Hauser, Inc. 2350 Endress Place Greenwood, IN 46143 USA Tel. 317-535-7138 Fax 317-535-8498 Sales 888-ENDRESS Service 800-642-8737 inquiry@us.endress.com www.us.endress.com Endress+Hauser Canada 1075 Sutton Drive Burlington, ON L7L 5Z8 Tel. 905-681-9292 800-668-3199 Fax 905-681-9444 www.ca.endress.com Endress+Hauser México S.A. de C.V. Fernando Montes de Oca 21 Edificio A Piso 3 Fracc. Industrial San Nicolás 54030 Tlalnepantla de Baz Estado de México Tel. +52 55 53 21 20 80 Fax +52 55 53 21 2 0 99 www.mx.endress.com Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel. +41 61 715 81 00 Fax +41 61 715 25 00 www.endress.com info@ii.endress.com TI060R/24/ae/12.07 FM+SGML6.0 ProMoDo