KRAL Volumeter - Turbine Fuel and Water Injection Measurement

Similar documents
COMBIMASS. Technical Data COMBIMASS eco-bio +

Air Eliminators and Combination Air Eliminators Strainers

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

Turbine Flowmeters for Gas Applications

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

How To Use A Flowmeter

COUNTERBALANCE VALVES

6. VVT-i (Variable Valve Timing-intelligent) System

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Custody Transfer Measurement. with the V-Cone Flowmeter

Turbine Flow Sensor Series VTR

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Electromagnetic Flow Meter

Turbine Flowmeter Vision 1000 Flowrates 0,1-2,5L/min. Turbine Flowmeter Vision 2000 Flowrates 0,5-35L/min

NORMAN FILTER COMPANY PRODUCT OVERVIEW

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

T U R B I N E G A S M E T E R

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

For Multi-Parameter Meters see mvx

The Unique Accelabar Flow Meter

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Electronic Flow Switches

THM Gas Turbines Heavy duty gas turbines for industrial applications

Power consumption (kw)

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

API Marine. BMS Presentation. Ballast Measurement Systems

Signature and ISX CM870 Fuel System

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Technical Specification. Generating Set with Waukesha engine burning natural gas

Laminar Flow Elements

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

KNC Model 3666 Automatic Pressure Calibration System

Take total control of your HVAC system with cost-saving flow and thermal energy meters

In-Line Electronic Flow Switches

Guidelines for Preparing for a Temporary Steam Plant

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

4 Posiflow Proportional Solenoid Valves

Micro Motion 3098 Gas Specific Gravity Meter

SELECTION, APPLICATION AND MAINTENANCE

Battery Powered Thermal Mass Flow Meters for Gases

Integrated Custom Systems

Valve Remote Control Systems Centralized Hydraulics for marine vessels and offshore installations

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Fundamental Principles of Rotary Displacement Meters

VAD. Variable Area Desuperheaters

08.08 Vic-Check Valves

HEAVY OIL FLOW MEASUREMENT CHALLENGES

Hydraulic Control Solutions

Marine after-treatment from STT Emtec AB

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

Data Sheet PS1B Pressure Switch

Continuous flow direct water heating for potable hot water

VAD Variable Area Desuperheaters

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

SMR Series Submicronic Removal Fluid Purifi cation Systems

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Frequently Asked Questions

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Diagram of components 2. Reducer..3

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Basic Hydraulics and Pneumatics

Originators of the Flexible Water Tube design

Series TMM Axial Piston Motor. Technical Information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Thermal Mass Flow Meters and Controllers for Gases

Diagnostic Fault Codes For Cummins Engines

Unit 8. Conversion Systems

Commercial & Industrial Propane Regulators and Meters

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

ELECTROMAGNETIC FLOWMETER COMPACT

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Energy and Flow Measurement for Hydronic Systems

PRESSURE REDUCING CONTROL VALVE

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Commercial Gas Water Heater

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Intelligent Vibration Monitoring

Sampling Solutions. Fuel and Lube Oil sampling Equipment. Convenient, Representative, Approved.

IFC 070 Technical Datasheet

SELECTION, APPLICATION & MAINTENANCE

Series DFMT Digital Paddlewheel Flowmeter

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

DIESEL FUEL CONDITIONING

A.Pannirselvam*, M.Ramajayam, V.Gurumani, S.Arulselvan and G.Karthikeyan *(Department of Mechanical Engineering, Annamalai University)

Transcription:

KRAL Volumeter - Turbine Fuel and Water Injection Measurement

Fuel Consumption Measurement for Turbines Accurate, reliable and leakage-free fuel consumption measurement, is now possible. Fuel Cost Reduction Claim Cost Reduction Power plant operators The planned down-time monitor any measurements of a turbine is typically that reduce the 5%. Unplanned shut operating costs. They downs can be very would also like to prove expensive, especially for the turbine specifications IPP s, because a shut are being met. High fuel down can close an entire costs make this an economic factory. For this reason, necessity. Meas- turbine manufacturers are urement with tank level seeing more penalty clauses gauges or billing from the that reduce the price fuel supplier are influenced or increase the warranty by temperature and period. fuel type variations. A The reliable and leakagefree KRAL Volumeter pre- practical direct measurement of fuel consumption vents claims like these. A is required. unique technical aspect is The extremely accurate the sensor s dry sleeve, KRAL Volumeters are installed which keeps the flow- directly in the fuel meter sealed if the sen- supply system. In multiturbine sor is taken out. When installations, a changing the sensor, there difference measurement is no reason to open the of the supply and return meter, which would require flow can provide individual depressurizing. turbine data. Typical operating parameters for the KRAL fuel consumption measurement system Fuel: Turbine Diesel and marine fuel Flow rate: up to 525 gal/min Pipe size: up to 4" Length: max. 20" (no flow conditioning required) Temperature: up to 300 F Consult factory for specific operating data or further information on the individual components of our fuel consumption measurement system. Compact Design Space is limited in power plant modules. Valves and pipe elbows are normally very close to a flowmeter. A flowmeter in a turbine module must be compact and not require additional room or flow conditioners. The Volumeter has a compact design compared with other high-pressure flowmeters. With a KRAL Volumeter there is never a need for flow conditioners. Robust Design p [psi] 3000 1500 10 20 symbolic diagram 30 t [ms] If dual fuel turbines switch over from natural gas to diesel oil, a valve is opened rapidly. This causes a strong pressure surge in the piping system. The flowmeter needs to have a robust design to handle such pressure pulses mechanically. KRAL Volumeters have a special spindle and casing design that protects the spindles from mechanical harm. 2

The Fuel Solution No flow conditioning or straight piping is necessary upstream or downstream of the meter. Through bolts for high-pressure safety. Rigid casing to handle pressure pulses without losing performance. Precision measuring chamber for high measurement accuracy. A second sensor can be installed for bi-directional flow measurement. Various connections are available for easy integration into existing piping, including: Pipe thread, ANSI, SAE, JIS and DIN flange. Sensor can be removed from dry sleeve even under full system pressure. 3

Water Injection Measurement for Turbines Stable measurement and easy installation for water injection measurement High flame temperatures create dangerous oxids fuel H C H H H H C H H H O2 air N2 + O2 N2 N2 O2 T>2200 F products CO2 NOX H2O NOX CO2 H2O NOX Reduction of Exhaust for Environmental Reasons Minimization of Water for Cost Reduction Typical operating parameters for the KRAL water injection measurement system Fuel: Demineralized water Flow rate: up to 180 gal/min Pipe size: up to 2" Length: max. 14" (no flow conditioning required) Temperature: up to 180 F Consult factory for operating data confirmation or further information for the individual components of our water consumption measurement system. Operating Principle Advantages Easy Installation Turbine improvement is a continuous task. Reduction of exhaust is a main target of these improvements. At temperatures above 2200 F the nitrogen of air burns into dangerous oxides (NOx). In order to reduce the NOx emissions, the temperature must be decreased. Water is injected to reduce temperature. The amount of water is controlled but not regulated. More and more turbine manufacturers want to regulate their water injection. For this kind of regulation, a suitable flow measurement is required. KRAL Volumeters are precise flowmeters that can measure water injection. Only demineralized water can be injected in the turbine. Demineralized water is very expensive. In some places it is more expensive than fuel. Because of this, water consumption should be optimized. Water consumption can be very high but it should not be any higher than necessary. A precise water measurement is required for optimization. The KRAL Volumeter is compatible with demineralized water and can measure this flow precisely. Every KRAL Volumeter is calibrated on the company s own test stand. This calibration is traceable to national standards. Electromagnetic and Vortex flowmeters are frequently used for water measurement. For this application, magnetic meters do not work with demineralized water since the liquid is non-conductive. Vortex meters need flow conditioning before the meter or they will not have the required accuracy. With the spindle design, KRAL Volumeters can function in water with high accuracy. No flow conditioners required 15 dia. Other meters used for water measurement depend on the flow profile. They depend on flow conditioners which needs space for integration. If the flow conditioners is shortened to accommodate limited space, then it is not as effective. KRAL Volumeters do not depend on flow profile and need no flow conditioners for accurate measurement. 4

The Water Solution Flow profile does not affect meter accuracy. Precision measuring chamber provide accurate measurement of injection water. Flow Measurement at High Pressure High Accuracy Fast Response Stainless steel casing. Easy Installation Spindle design can The KRAL Volumeter measure demineralized OMH Series is designed water and requires for high no pressures, up to flow conditioning. 6000 psi. This is evident from the appearance of the meter: robust casing through bolts precise design exact machining With certain engineering changes, the OMH has been manufactured for line pressures up 15,000 psi. If you compare the meter photograph on the front cover and the cut-away photo above, you will notice the strong casing Various connections of the aremeter hides an unexpected integra-feature inside a available for easy tion into existing fine, piping, high-precision measuring instrument. including: Pipe thread, ANSI, SAE, JIS and DIN flange. Even with high system pressures, many applications also require high accuracy. The accuracy of a PD meter depends greatly on the geometry of the measuring chamber, which is formed by the spindles and casing. The OMH is designed to prevent any change in the measuring chamber, even under high pressure. The OMH also maintains high accuracy with: special spindle and casing design detailed machining calibration of each unit on our in-house test stand. Page 3 shows the design necessary for the high precision and turndown of the OMH. See the Rapid changes in flowrate and direction can often cause performance and mechanical problems for high pressure flowmeters. For applications such as a hydraulic test stand, a fast meter response is required for accurate and reliable measurement. The precise machining of the OMH allows the spindles to rotate easily without allowing liquid to pass through unmeasured. Even with flowrate and direction changes, the spindles can respond instantly and accurately. The fast response of the OMH is complimented by its wide flow and viscosity range, as shown in the Measuring Range diagram on page 6. There is often limited space available to install a flowmeter. As a solution, the OMH is compact and lightweight for this class of instrument. KRAL Volumeters are insensitive to flow disturbances, so there are no upstream or downstream installation requirements. The OMH can be installed at any angle. Even bi-directional flow can be measured precisely. Industry Standard connections and output signals allow for easy integration into new or existing Industry standard outputs systems. for easy integration. 5

KRAL Volumeter - Components of a Fuel Consumption and Water Injection Measurement System Application OMG* or OMH* OMS BEM 4U* BEM 2U* BGG EET Description Fuel consumption measurement Water injection measurement SFOC** measurement in [g/kwh] Sealed flowmeter for claim cost reduction Standard or High Stainless Steel Flow & Energy Local Dry Temp. Pressure Flowmeter Flowmeter Computer Display Sleeve Sensor or or or * For detailed product information, please request our product series brochures. ** Specific fuel oil consumption 6

Sound Applications to Choose KRAL Fuel Consumption Measurement on Turbines Water Injection Measurement on Turbines Diesel Engine FC Measurement Worldwide Presence Liquid: Diesel Oil Flow rate: 7.4 to 470 gpm Pressure: 2000 psi Temperature: 60 to 180 F Viscosity: 1.6 to 6 cst Measuring instrument: OMH 100 with -sensor A turbine manufacturer needed to measure the consumption of diesel oil in an explosion-proof area. The special requirements for this application included: high flowrate at high pressure in minimum space accurate and reliable measurements explosion-proof electronics long service life world-wide service The KRAL Volumeter OMH 100 was selected to measure the oil consumption of this turbine. Water injection principle water fuel Liquid: Demineralized Water Flow rate: 6.6 to 100 gal/min Temperature: 41 to 104 F Pressure: 2030 psi Measuring instrument: OMS 52 To reduce NOx exhaust our customer needed a turbine water injection regulation. For a regulation a turbine manufacturer required accurate measurement. He could not use magnetic or Vortex flowmeters because they don t work with demineralized water or need flow conditioners. The KRAL OMS 52 was selected, because this high accurate PD flowmeter measures demineralized water with high system pressure. There is never a need of flow conditioners. Liquid: Heavy Fuel Oil Flow rate: up to 44 gal/min Temperature: 275 F Pressure: 116 psi Measuring instrument: OMG 52 KRAL is very experienced in fuel consumption (FC) measurement for Diesel engines. With multiple engine installations operators need an engine related measurement. This requires a measurement of the supply and return flow close to the injection pumps. The injection pumps cause pressure pulses which may be responsible for surge impact on the flowmeter. There are also fuel temperature differences. OMG with pressure-pulse and temperature compensation was selected. KRAL is located in central Europe and the United States to allow fast, worldwide response to our customers. Our website also offers the latest information regarding our products and solutions that have helped customers for over 50 years. Please visit us at www.kral.at or www.kral-usa.com. KRAL and KRAL -USA look forward to serving you in the future. 7

Subject to change 12/01 All rights reserved. ender werbung KRAL-USA, Inc. East: P.O. Box 2990, 901A Matthews-Mint Hill Road (28105), Matthews NC 28106, USA, Tel: (704) 814-6164, Fax: (704) 814-6165 West: 700 E. Redlands Blvd. Suite U. #209, Redlands, CA 92373, USA, Tel: (909) 335-8765, Fax: (909) 335-8755 www.kral-usa.com