PXR Series Advanced Self-Tuning Temperature and Process Controllers

Similar documents
Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

MLC TM Maximum Productivity and Versatility for Control without Compromise!

PX-series digital temperature controller Example of Applications and Parameter Functions

+ A B V B NO NC V COM PV PV

PIEZOMETER AIRFLOW MEASURING RING

User Manual Auto Tuning PID Temperature Controller

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

J TB/TW Temperature limiter, temperature monitor

HONEYWELL DC 1010 / / 1040 DIGITAL CONTROLLER PRODUCT MANUAL /02

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

INITIAL SETTING MANUAL

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Electronic Control Devices The European Product Catalogue 2007

IntesisBox KNX LG Air Conditioning

NC-12 Modbus Application

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Controller Automation, Model II+

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

Multifunction devices

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

FIREDEX Conventional Fire Panels

#1381-3, Juan-dong, Nam-gu, Incheon, Korea TEL:(82-32) FAX:(82-32)

Electronic Control Devices The European Product Catalogue 2007

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

HERZ-Thermal Actuators

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Delta Temperature Controller User Manual

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Temperature & Humidity SMS Alert Controller

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

IntesisBox Modbus Server SAMSUNG Air Conditioners

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

UDC2500 Universal Digital Controller. Specification. Overview. Features. Analog Inputs /04 Page 1 of 13

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Duct Humidity Transmitter

Energy Management Power Analyzer Type WM14-96 Basic Version

TC-9102 Series Surface Mount Temperature Controllers

SMS GSM Alarm Messenger

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Installation manual. Generator Paralleling Controller GPC multi-line C

MODEL T48-1/16 DIN TEMPERATURE CONTROLLER

Modbus Server SAMSUNG Air Conditioners

KNX Panasonic Air Conditioners

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

Thyristor-controlled power supplies and battery chargers

Quick Connect. quick - simple - efficient.

DC Electronic Loads 8500 series

WD-AMX Water Detection Controllers

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Quick Reference Guide

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Material test chamber with mechanical convection

Solid-State Timer H3G

Multi-Range Programmable DC Power Supplies 9115 Series

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

SR1, SR3 Series Digital Controller Instruction Manual

DIGITRONIK Digital Indicating Controller SDC10. User s Manual

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

IntesisBox KNX Mitsubishi Heavy Industries AC

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Digital inductive conductivity transmitter

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Multi-Range Programmable DC Power Supplies 9115 Series

CQM1-SF200/CS1W-SF200

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Incubator with mechanical convection

Easy to connect - Easy to configure Easy to install

How To Use A Ds340 (Dsp)

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Modular I/O System Analog and Digital Interface Modules

Controls for fan coil units and cassettes

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

DC DC DC DC1040

A project to optimise quality and energy efficiency must include metering

Application/Connection Examples

IntesisBox KNX Modbus RTU master

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

ACS-30-EU-EMDR-10-MOD

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

is then retained absolutely without interruption.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Transcription:

PXR Series Advanced Self-Tuning Temperature and Process Controllers Key Features PID Description with fuzzy control of self-tuning 16 Ramp/soak segments Large LED display Auto-tune Timer function Heater burnout alarm Replaces most other controllers in market Excellent for after-market support The new PXR series controllers are the newest additions to Fuji Electric s trusted line of temperature and process controllers. They are now packed with more features and options than before, and the new low price is unbeatable. They come in several sizes 1/32 DIN, 1/16 DIN, 1/8 DIN and 1/4 DIN. These controllers have all the standard features that you expect from Fuji Electric s superior controllers, and more. In addition to auto-tuning and fuzzy control, it now comes with self-tuning an innovation in the control field. It automatically retunes the controller under certain conditions, without the need to revert to auto-tuning. The standard 8-segment ramp/soak feature has been expanded to include two patterns that can be linked to create a 16-step profile. The PXR accepts temperature and process inputs and offers a choice of three kinds of outputs to meet a wide variety of needs in the process industries. Low-cost options include dual outputs, programmable alarms, remote setpoint, RS485 communications, analog retransmission, digital input, timer function, heater burnout alarm and 24V AC/DC supply voltage. One of the most impressive features is the large LED display. The faceplate, designed for NEMA 4X (IP66 equivalent) is watertight and corrosion-resistant. The easy-to-use 3-button keypad allows for programming similar to the popular PXW controller. The screw-terminal on the back further reduces the cost by eliminating the need for sockets. The PXR3 can be DIN-rail mounted with the optional adapter. Remote monitoring of up to 31 controllers at a time is possible with the RS485 option that uses the industry-standard Modbus TM protocol. The communications option comes with our free Windows -based software, PXR-LITE TM. The software allows you to program the controller from the PC and view real-time data and trend graph while logging the data into a text file. A powerful tool for the OEM customer is the Program Loader option with Windows -based software. Programs for different applications can be saved to and from the controller. Features Advanced control functions PID Plus Self Tuning; PID Plus Fuzzy Control; Autotuning NEMA 4X faceplate with large LED display 4-digit, red and green display; Waterproof faceplate conforms to NEMA- 4X/IP66 Multiple inputs Choose between thermocouple/rtd and 4-20mA/0-5V inputs Single or dual control outputs Relay, driver or 4-20mA Ramp/soak function Up to 16 ramp/ soak segments or two 8-segment patterns, a standard feature Programmable alarms option 2 programmable SPST relays with On/Off delay function Remote setpoint option Change setpoint with a 1-5V signal Analog retransmission option 4-20mA retransmission of, SV, MV, DV option Change between 2 setpoints; Change between ramp/soak and standby; Start/reset the ramp/soak; Start/stop the auto tuning; Cancel the alarm latch; Start the incorporated timer Timer function On-delay or off-delay timer activated with digital input; Up to 2 timer outputs can be obtained Heater burnout alarm option If heater burns out, alarm goes off Communications option RS485 (ModbusTM protocol) interface permits remote monitoring of up to 31 units from a PC. Comes with free Windows -based software, PXR-LITE TM Warranty Manufactured in a ISO 9001 facility and backed by a 3-year warranty 2

Specifications General Specifications Power supply voltage 100 (-15%) to 240V (+10%) AC, 50/60Hz; 24V (±10%) AC/DC Power consumption PXR3: 6VA (100 V AC), 8VA (220V, 24V). PXR4: 8VA (100V), 10VA (220V), 12VA (24V). PXR5, 9: 10VA (100V), 12VA (220V, 24V) Reference junction compensation accuracy ±1 C at 23 C Input Input signal Thermocouple: J, K, R, B, S, T, E, N, PL2. RTD: Pt100. Voltage, current. For 1 to 5V/4 to 20 ma DC, 0 to 5V/0 to 20 ma DC, use 250 ohm shunt resister included Input filter 0 to 900.0 sec set in 0.5 sec steps Burnout For thermocouple or RTD input, control output direction (upper or lower) is selectable Control Function Control action On/Off; PID control (with auto-tuning, self-tuning); Fuzzy Control (with auto-tuning) Proportional band (P) 0 to 999.9% of measuring range set in 0.1% steps Integral time (l) 0 to 3200 sec set in 1 sec steps Differential time (D) 0 to 999.9 sec set in 1 sec steps Proportional cycle 1 to 150 sec set in 1 sec steps Hysteresis width 0 to 50% of measuring range; For on/off action only Input sampling cycle 0.5 sec Program Loader Interface The Program Loader for Fuji Electric s PX and PXR series controllers is a powerful tool for the OEM customer. Using the PXR4 Loader Assembly, the controller can be configured from a PC running on Windows environment. PXR LITE Communications Software Features Retrieve or store controller data Selectively mask or unmask parameters for viewing on the controller Clone settings to other controllers from saved files Print data report Control Output 1 (select one) Relay contact PXR4, 5, 9: SPDT, 220 V AC/30 V DC, 3A (resistive load). PXR3: SPST contact, 220 V AC/30 V DC, 3A (resistive load) PXR4, 5, 9: ON 17 to 25 V DC; OFF 0.5 V DC or less. PXR3: 12 to 16 V DC. Max. current: 20mA or less 4 to 20 ma DC PXR4, 5, 9: Allowable load resistance 600 ohms or less. PXR3: 100 to 500 ohms Control Output 2 (Heating/ Cooling Control) (select one) Relay contact SPST, 220 V AC/30 V DC, 3A (resistive load) PXR4, 5, 9: ON 17 to 25 V DC; OFF 0.5 V DC or less. PXR3: 12 to 16 V DC. Max. current: 20mA or less 4 to 20 ma DC PXR4, 5, 9: Allowable load resistance 600 ohms or less. PXR3: 100 to 500 ohms PXR-LITE TM is free Windows -based software that is supplied with the communications option on a PXR controller. It is the latest in control and monitoring of Fuji Electric s PXR series controllers. It provides continuous remote monitoring of single or multiple controllers using a single half-duplex RS485 line. Features Monitor and control up to 31 controllers from a PC via RS485-RS232 signal converter Real-time charting and data-logging Remote setpoint adjustment Set control modes, alarms and other control parameters Remote auto-tuning and ramp-soak programming Live display of process and setpoint values, alarm annunciators View single-station or multi-station data Comprehensive help file included Runs on Windows environment, version 3.1 or later 3

PXR Series (continued) Operation and Display Section Parameter setting method Digital setting by 3 keys; Key lock function provided Display unit Process value/set value displayed individually 4 digits, 7-segment LED Status display LED Control output, process alarm output, heater burnout alarm output Indication accuracy (at 23 C) Thermocouple: ± (0.5% of measuring range) ± 1 digit ±1 C. For thermocouple R at 0 to 500 C: ± (1% of measuring range) ±1 digit ±1 C. For thermocouple B at 0 to 400 C: ± (5% of measuring range) ±1 digit ±1 C. RTD, voltage/current: ±(0.5% of measuring range) ±1 digit Alarm (option) Alarm type Absolute alarm, deviation alarm, zone alarm with upper and lower limits for each; hold function available; alarm latch function provided Alarm ON-delay Delay setting 0 to 9999 sec set in 1 sec steps Process alarm output Relay contact: SPST, 220 V AC/30 V DC, 1A (resistive load); Max. 2 points (PXR3), max. 3 points (PXR4, 5, 9) Heater burnout option (not available on PXR3) Alarm setting range: 1 to 50A Available only when control output is relay or drive. Heater burnout alarm output Relay contact: SPST, 220 V AC/30 V DC, 1A (resistive load); 1 output point Current detector CTL-6-S for 1 to 30 A; CTL-12 for 20 to 50 A Digital Input (option) Points 1 or 2; contact closure. 5 V DC, approx. 2mA Function (select one) Set value (SV, SV1 to 3) changeover, start/stop control action, start/reset ramp/soak action, start/stop auto-tuning, cancel alarm latch, start incorporated timer Retransmission Output (option) Output signal 4-20 ma DC Load resistance 500 ohms or less Output accuracy ±0.3% FS Output selection, SV, MV, DV (SV-) PXR4 Terminal Cover (option) Timer Function (option) Start By digital input option Setting 0 to 9999 sec set in 1 sec steps Action Event ON-delay or OFF-delay Signal output Alarm output relays used; 2 points are available Communication Function (option) Physical specifications EIA RS485 Communication protocol Modbus (RTU). Free Windows -based software, PXR-LITE TM Communication method 2-wire method; half-duplex, bit serial, start-stop sync type Data type 8 bits. Parity: odd/even/none Communication rate 9600 bps Connection aspect Multi-drop up to 31 controllers Communication distance Total extension 500m or less RS232C/RS485 signal converter RSFC24 (recommended, see ordering information) Remote Setpoint Option Input signal 1 to 5 V DC, 1 point Accuracy ±0.5% ±1 digit Input sampling cycle 0.5 sec Display of remote mode LED on front panel Input impedance 1M ohms or more Other Functions Parameter mask function Parameter display can be disabled from keypad PXR3 DIN Rail Adapter Ramp/soak function 8 ramps and 8 soaks; 1 or 2 program patterns; digital input allows start/reset of the action Operating and Storage Conditions Ambient operating temperature 14 to 122 F (-10 to 50 C) Ambient operating humidity Less than 90% RH (no condensation) Storage temperature -4 to 140 F (-20 to 60 C) Structure Mounting method Panel flush mounting. PXR3 can be DIN-rail mounted using the optional adapter External terminal Screw terminal Dimensions PXR3: 1 x 2 x 4 in. (24 x 48 x 98mm). PXR4: 1.89 x 1.89 x 3.37 in. (48 x 48 x 79.8 mm). PXR5: 2.07 x 3.96 x 3.77 in. (52.5 x 100.5 x 95.8 mm). PXR9: 3.96 x 3.96 x 3.77 in (100.5 x 100.5 x 95.8 mm) Protective structure Front panel NEMA4X (IEC standard IP66 equivalent) (when mounted on panel with supplied gasket). Rear case: IEC IP20 Outer color Black (front panel, case) Agency approvals UL, c-ul recognized (UL873), CSA (C22.2 No.24-93), CE certified (LVD:EN61010-1, EMC:1326-1) Optional Items Current transformer For 1 to 30 A: CTL-6-S. For 20 to 50 A: CTL-12 Signal converter for communication function RSFC24 DIN Rail adapter For PXR3 only Terminal cover For PXR4 only 4

Ordering Information (PXR3) P X R A B C D 1 E F G A 1 To create a part number f ll in the boxes above with the appropriate number and/or letter from the corresponding list below. Box A: Front Panel Size 3 = 1/32 DIN (24x48mm) Box B: Input Signal T = Thermocouple ( C) R = Thermocouple ( F) N = RTD, Pt100 ohm, 3-wire type ( C) S = RTD, Pt100 ohm, 3-wire type ( F) B = 4-20mA DC, 1-5V DC A = 0-20mA DC, 0-5V DC Box C: Control Output 1 E = 4-20mA DC output Box D: Control Output 2 Y = None E = 4-20mA DC output Box E: Alarm Options 4 = None 5 = High/low alarm 1 point G = High/low alarm 2 points 1 Box F: Power Supply V = Standard (100-240 VAC, 50/60Hz) B = 24V AC/DC (50/60Hz) Box G: Additional Functions 0 = None M = RS485 communication (Modbus) Q = Retransmission + DI 1 point R = Retransmission (4-20mA DC) T = Digital Input (DI) x 2 V = RS485 communications (Modbus) + DI Note: RS485 option comes with Free software, PXR-LITE. RS485 requires signal converter to connect to PC, P/N RSFC24 recommended. 1 High/low alarm 2 points not available when control output 2 is selected. Ordering Information (PXR4, PXR5, PXR7, PXR9) P X R A B C D 1 E F G A 1 To create a part number f ll in the boxes above with the appropriate number and/or letter from the corresponding list below. Box A: Front Panel Size 4 = 1/16 DIN (48x48mm) 5 = 1/8 DIN (48x96mm) 7 = 72 x 72mm 9 = 1/4 DIN (96x96mm) Box B: Input Signal T = Thermocouple ( C) R = Thermocouple ( F) N = RTD, Pt100 ohm, 3-wire type ( C) S = RTD, Pt100 ohm, 3-wire type ( F) B = 4-20mA DC, 1-5V DC A = 0-20mA DC, 0-5V DC Box C: Control Output 1 E = 4-20mA DC output 1 G = Triac 1A, 250 VAC 4 Box D: Control Output 2 Y = None E = 4-20mA DC output 1 G = Triac 1A, 250 VAC 4 R = Retransmission (4-20mA DC) Box E: Alarm Options 4 = None 6 = Heater break alarm 1,2 G = High/low alarm 2 points H = High/low alarm 2 points + heater break alarm 1,2 M = Alarm 3 points D = Remote setpoint 3 P = Remote setpoint + alarm 2 points 3 11 Note: RS485 option comes with Free software, PXR-LITE. RS485 requires signal converter to connect to PC, P/N RSFC24 recommended. 1 Heater break option not available with 4-20mA output, or with 2 digital inputs, or with RS485 +1 digital input. 2 Must order current transformer CTL-6-S or CTL-12 with heater break option. 3 Remote setpoint option not available with RS485 +1 digital input. 4 UL and c-ul not available with PXR5 or PXR9. Box F: Power Supply V = Standard (100-240V AC, 50/60Hz) B = 24V AC/DC (50/60Hz) Box G: Additional Functions 0 = None M = RS485 communication (Modbus) S = Digital Input (DI) x 1 T = Digital Input (DI) x 2 1 V = RS485 communications (Modbus) + DI 1,3 Accessories CTL-6-S Current transformer for 1-30A CTL-12 Current transformer for 20-50A RSFC24 RS485 to RS232 signal converter PXR4 Loader Assembly Program loader for PXR4 (can be used for PX series also) PXR3 Rail Adapter Mounting adapter for DIN rail installation PXR4 Terminal Cover Terminal block protective cover Information subject to change without notice. Prices in USD. 010110

PXR4 Temperature Controller Socket Series Ordering Information (PXR4 Socket Version) P X R 4 A B S 1 C D 0 A 1 To create a part number fi ll in the boxes above with the appropriate number and/or letter from the corresponding list below. Front Panel Size 4 = 1/16 DIN (48x48mm) Box A: Input Signal T = Thermocouple ( C) R = Thermocouple ( F) N = RTD, Pt100 ohm, 3-wire type ( C) S = RTD, Pt100 ohm, 3-wire type ( F) B = 4-20mA DC, 1-5V DC A = 0-20mA DC, 0-5V DC Box B: Control Output 1 E = 4-20mA DC output 1 G = Triac 1A, 250 VAC 4 Box C: Alarm Options 4 = None 5 = Hign.low alarm 1 point G = High/low alarm 2 points Box D: Power Supply V = Standard (100-240V AC, 50/60Hz) B = 24V AC/DC (50/60Hz) Accessories PXR4 Loader Assembly PXR4 Terminal Cover Program loader for PXR4 Terminal block protective cover Information subject to change without notice. Prices in USD. 050110

PXR Series (continued) Application Examples Furnace Heat Pattern Control Heat Pattern Control Ramp/Soak Function Ramp/Soak command ON : RUN OFF : RESET Voltage pulse output Furnace Thermocouple Oven To change SV easily Voltage pulse output Main-setting / Sub-setting Switchover OVEN Ramp/Soak Function Control temperature according to Heat pattern with ramp Keep temperature stable for a certain period with Heat pattern and then cool down Heat pattern can be Started (RUN) /Reset by an external digital input. C SV1 SV2 RUN Time SV3 RESET SV4 Set Value (SV) can be selected/changed externally. <main SV, SV1~3 change over> Fryer To keep oil temperature stable Control : RUN / STAND-BY OFF : RUN ON : STAND-BY Voltage pulse output Fryer Plastic Molding Machine Stable temperature control required Fuzzy + PID Control Autotuning command ON : Autotuning Start OFF : Autotuning Strat oil Heater Control RUN/Stand-by selectable through external digital input Cooling & Heating Control Process Alarm Tuning Action SV Voltage pulse output ON ON Molding Machine (Extruder) Material Sterilizer Heat / Cool Dual Output Output Overlap Deadband Heating Cooling Water Steam Heater Auto-Tuning can be started/stopped through external digital input Cooling output and Heating output can be overlapped or a Deadband set between them. 6