INSTALLATION & START-UP INSTRUCTIONS FLECK 7000SXT METER WATER SOFTENER SYSTEMS QualityWaterForLess.com

Similar documents
Fleck 7000 Softener Installation & Start-Up Guide

Clean Water Made Easy

Pro-OX 7800 Iron Filter Installation & Start-Up Guide

Water Tec of Tucson Water Systems

Model 5600 & 5600 Econominder

Model 5600 & 5600 Econominder

Water Tec of Tucson Water Systems

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Model 5600SE Downflow

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

WATER SOFTENER SYSTEMS

ECONOFLO 5600SXT SOFTENER Model 5600 SXT-User Programming Chart Time of Day. Model 5600 SXT -User Programming Chart

Water Tec of Tucson. WS1TA Twin Alterna ng Water so ener

Fleck 7000SXT. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET

MODEL Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

Water Specialist 1 Control Valve Series Model: WS1

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual.

Metermatic SE Automatic Water Softener. Operation Manual

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

Installation Instructions S

7500 Pro-Ox Filter Installation & Start-Up Guide

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

RXD Water Softener. Water Conditioning. Owner s Manual R4039. RXD Owner s Manual. Page 1

Watts Pure Water Systems

10/20 COMBINATION UNIT

OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS

INSTALLATION AND SERVICE MANUAL

Owner s Manual / 5600 Econominder

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Installation Instructions

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

Calcite PH Nutralizer System

How To Replace A Reverse Osmosis Water Tank

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

INSTALLATION INSTRUCTIONS MK-8704

Air Conditioner Water Heater Model ACWH18

INSTALLATION INSTRUCTIONS BL-8704

485HE High Efficiency Water Softener. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

7000 Master Programming Mode

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

SIGNATURE 2 SERIES. Greensand Plus Iron Filter Manual. Installation / Operation Manual

Model 7000 Master Programming Mode

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Series 255 Valve / 460i. Water Conditioning Control System Installation, Operation and Maintenance Manual

Operating and Service Manual SXT Automatic Chloramines Removal Filter. Made in Canada

Estimated Water Savings

Geyser-R Heat pump water heater Installation manual

Southwest Florida Water Management District. Fix It for Less

Autotrol 460i and 460TC Control System

INSTANT HOT WATER RECIRCULATING SYSTEM

Select Radiators Installation Guide

2006 HEADSHOK Service Video #1

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

To Repair or Replace?

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

MODEL NO Caution: Read and follow all safety rules and operating instructions before first use of this product. Warranty Installation

Submersion/Insertion Toroidal Sensor

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Light Ready Return Water Fitting for Above Ground Pools Owners Manual

SunMor SM-V30 Solar Water Heater Installation Manual

EcoSoft Water Softener. General Installation Guide

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Stenner Pump Chlorinator Installation & Start Up Guide

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

SunMaxx Solar Filling Station Operating Instructions

Porcelain Vessel Sink Installation

Installation and Operating Instruction Manual

WATER VALVE OWNER S MANUAL REV051811

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Water Softening. system. GE Appliances. Safety Instructions Proper installation...3. Owner s Manual & Installation Instructions

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Owner s Manual. 12 Volt Electronics

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV General. Removal (Left and Right Forks) Kit Number

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Troubleshooting Guide for Dispenser Model #900172

INSTALLATION INSTRUCTIONS P-TRAP SUPPLY KIT Model: RH-3016 These instructions are a guideline for a basic installation

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

detection kit the water leak water leaks: What you should know A helpful guide for locating indoor and outdoor water leaks Getting Ready

User and Installer Handbook

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0

INSTALLATION INSTRUCTIONS

Grade Level Spill Containment Manholes

Finding and Fixing Leaks

A High Bill Usually Means a Leak

Transcription:

INSTALLATION & START-UP INSTRUCTIONS FLECK 7000SXT METER WATER SOFTENER SYSTEMS 1999-2009 QualityWaterForLess.com - 1 - info@qualitywaterforless.com

Preface: Thank you for your purchase of a new Water Softener with Fleck 7000SXT Meter from QualityWaterForLess.com! We have put together these instructions as reference, and to be used as general installation guidelines. It is always recommended that a licensed plumber perform all installation work according to all local codes. We at QualityWaterForLess.com cannot assume responsibility for improper installation, application, or injury or damage as a result of improper installation. Pre-Installation Guidelines: Before assembly of your new system, be sure that the following conditions have been met for placement of your system: Level, firm surface, such as concrete, on which to place the softener tank and salt tank (as known as a brine tank) Nearby floor drain or standpipe to connect to the softener for use during each regeneration Un-switched power source, standard US plug, 120v 60hz (the softener system includes a 5ft. power cord and plug) Access to the water main coming into your home. You will need to install the softener at this point to assure that water for the home is going through the system. Placing and Filling the Tank: Choose the final location for your water softener tank, and place the tank upright and level on the surface. Filling the tank may be necessary on some systems. Your tank may have also come prefilled, and in this case you only need to unscrew the protective cap as shown below in Figure 1 and move on to the next section. FIGURE 1 1999-2009 QualityWaterForLess.com - 2 - info@qualitywaterforless.com

If your tank is not filled, please follow the additional instructions below. First, place the riser tube into the tank as shown in Figure 2. NOTE: Please be sure that the riser tube seats into the bottom of the tank, and that the top of the riser tube is FLUSH with the top of the tank lip. FIGURE 2 Before filling the tank, place a piece of duct tape over the top of the riser to prevent resin from dropping down inside the riser tube as shown in Figure 3. Place the included filling funnel over the top of the tank as shown in Figure 4, and prepare to fill the tank. If your softener system came with Gravel, please pour this amount into the tank FIRST, then pour in the included resin media afterwards. FIGURE 3 FIGURE 4 Remove the filling funnel and duct tape and go on to the next section 1999-2009 QualityWaterForLess.com - 3 - info@qualitywaterforless.com

Installing the Fleck 7000SXT Meter Control Valve: Using the included silicone lubricant packet, lubricate the inner and outer o- rings on the bottom of the Fleck 7000SXT Meter Valve as shown in Figures 5 & 6 below. FIGURE 5 FIGURE 6 Next, place the Fleck 7000SXT Meter Valve onto the top of the tank, being sure that the riser tube fits into the central o-ring on the valve, as shown in figure 7 below. Hand tighten the valve to the tank snugly by hand only. NOTE: Do not use Teflon tape or pipe dope on the valve or tank threads. FIGURE 7 Locate the plumbing adaptors and bypass valve assembly that was shipped with your system. Also, disassemble the plumbing adaptor clips as shown in Figure 8 on the following page. Using the included silicone lubricant packet, lubricate the o-rings on the bypass valve as shown in figure 9 on the following page. Finally, push the bypass valve snugly to the back of the 7000SXT valve as shown in Figure 10 on the following page. Use the red clips to secure the bypass valve as shown in figure 11 on the following page. 1999-2009 QualityWaterForLess.com - 4 - info@qualitywaterforless.com

FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 Locate the two plumbing adaptors supplied with your 7000SXT system. Using Teflon tape, wrap the threaded end of your plumbing adaptor as shown in figure 12 below. Next lubricate the o-ring on each adaptor as shown in figure 13 below. Push in, and secure each plumbing adaptor into place using the red clips supplied as shown in figure 14. FIGURE 12 FIGURE 13 FIGURE 14 1999-2009 QualityWaterForLess.com - 5 - info@qualitywaterforless.com

Plumbing your Fleck 7000SXT Meter: Before beginning your installation, please first familiarize yourself with the IN and OUT on the Fleck 7000SXT Meter Valve. In order to prevent damage to your home and to the softener system, install the softener according to the IN and OUT arrows on the softener valve! Find the main shut-off valve for your house and turn it to the OFF position. If you have a private well, this valve should be near your well pressure tank. If you have a city water supply, your valve should be near your water meter. Depressurize and drain your home of water by turning on all faucets and fixtures in your home, including those outside. Pick your installation point, and cut a section of pipe out to run to and from your softener. NOTE: In many cases, it is preferred to keep outside lines UNSOFTENED. If you wish to keep your outside lines unsoftened, you must plumb Bypass lines to run hard water to these fixtures. Using soldered (or "sweated") copper, PVC plastic pipe, or flexible connections, plumb the system according to all local plumbing codes. NOTE: If using copper pipe, please pre-fabricate at least a 12 section of pipe for the IN and OUT bound lines. Attach the prefabricated sections to your threaded plumbing adapters, and wrap a wet rag around this connection to prevent heat damage during soldering. Once all connections have been made, place the system into bypass by either using your existing 3-valve bypass (if ordered with a Yoke adaptor), or by switching your included bypass to IN BYPASS position. See the figures below for a demonstration of how to use the bypass valve included with your 7000SXT system. The holes in the two bypass handles should be Up & Down as shown. Next, gradually open your main valve and allow all air in your plumbing lines to escape slowly. Also, you may turn off all outside and inside faucets and fixtures. Check for leaks at your plumbing site for signs of slow drips, and rectify if necessary. Please DO NOT position the bypass valve to IN SERVICE at this time, as the installation is completed yet! NOTE: Please take this opportunity to check and re-check the IN and OUT to make sure that they are correct! Holes Up & Down is In Bypass Use a screwdriver to move each side 1/4" turn to move the bypass to In Service 1999-2009 QualityWaterForLess.com - 6 - info@qualitywaterforless.com

Making the Brine Tank Connection: Locate the Brine Fitting Assembly on the 7000SXT Valve, and pull out the Gray retaining clip as shown in figure 15 below. Remove the Assembly as shown in figure 16 below. FIGURE 15 FIGURE 16 Locate the included section of Brine Tubing and the Brine Nut Assembly as shown in figure 17 below. IMPORTANT! Onto one side of the included Brine Tubing, assemble the Brine Nut Assembly exactly as shown in Figure 18 below. FIGURE 17 FIGURE 18 Tighten the nut to the Brine Fitting Assembly using until snugly tightened in place. Be careful not to over tighten, as you may sever the brine line tubing. See figure 19 on the following page. Push the Brine Fitting Assembly back into place and secure the Assembly with the Brine Fitting Clip as shown in figure20 on the following page. 1999-2009 QualityWaterForLess.com - 7 - info@qualitywaterforless.com

FIGURE 19 FIGURE 20 Locate the included brine tank, and remove the brine tank cover shown below Figure 21. Next, locate the brine well, and remove the cap as shown in Figure 22 below. FIGURE 21 FIGURE 22 Pull the 2310 brine float assembly out of the brine well and disassemble the retaining nut as shown in Figure 23 below. Next, assemble the 2310 brine float assembly to the brine well through the predrilled hole and hand-tighten as shown in figure 24 on the following page FIGURE 23 FIGURE 24 1999-2009 QualityWaterForLess.com - 8 - info@qualitywaterforless.com

Take the other end of your brine line tube and insert the tube through the small hole drilled through the brine tank, and brine well. Loosely unscrew the hex nut on the 2310 brine float assembly. Insert the tubing end firmly into the hex nut on the 2310 brine float assembly. Next back-off the hex nut and ferrule assembly so they are securely onto the tubing as shown in Figure 25 below. NOTE: Please be sure to assemble the nut in the fashion described to prevent system malfunction and possible brine tank overflow! Hand-tighten the hex nut snugly onto the 2310 brine float assembly as shown in Figure 26 below. FIGURE 25 FIGURE 26 Finally, use ½ I.D. tubing (sold separately, or the same as the drain tubing which you may have elected to add to your system during your order) to connect the drain barb fitting on the brine tank to a floor drain as shown in Figure 27 below. NOTE: This is not necessary as the 2310 assembly is designed to prevent an overflow situation, but is a good and recommended precaution for a proper installation. FIGURE 27 1999-2009 QualityWaterForLess.com - 9 - info@qualitywaterforless.com

Making the Drain Connection: Locate the Drain Fitting Assembly on the 7000SXT Valve, and remove the gray retaining clip as shown in figure 28 below. Remove the fitting by pulling upward as shown in figure 29 below. Use Teflon tape to wrap the threading as shown in figure 30 below. Install the included drain barb assembly to the Fleck 7000SXT Meter Valve by screwing the fitting using a wrench snugly unto the threads as shown in Figure 31 below. Please use caution not to over tighten this fitting. FIGURE 28 FIGURE 29 FIGURE 30 FIGURE 31 Push the drain fitting assembly back onto the 7000SXT Valve snugly and secure the fitting with the gray clip as shown in figure 32 below. FIGURE 32 1999-2009 QualityWaterForLess.com - 10 - info@qualitywaterforless.com

Next, assemble your ½ I.D. drain line to the drain barb as shown in Figure 33 on the following page. Be sure to use rigid wall ½ I.D. tubing that will not flatten Wrap electrical tape over the drain tubing to prevent a tubing split, and clamp the tubing securely into place with the included blue clamp as shown in Figure 34 below. FIGURE 33 FIGURE 34 Connect the other end of this drain line tubing SECURELY to a standpipe or drain in accordance with all local plumbing codes. NOTE: Be sure that the drain line is securely in place before the use of the water softener system. When the system regenerates, there will be increased flow via this tubing, which may cause the tubing to become loose. Programming the Fleck 7000SXT Meter Valve: Before start-up a few simple steps must be followed to program the Fleck 7000SXT Meter Valve. It will be important to know your water Hardness and Iron quantities before doing this programming procedure. If you do not know your water hardness, or if you are unsure, you may wish to have it tested by sending us a sample for testing, or by taking a sample to a local pool supply, or hardware store. Your Hardness test results may indicate Grains, PPM, or mg/l. It is important to note that PPM and mg/l are the same measure and both figures can be treated interchangeably. If you get a hardness figure in PPM or mg/l, please divide this number by 17.1 to get Grains. Ex: If your hardness is measured at 300 PPM, your Grains are 300 / 17.1 = 18 Grains. Your Iron results should be measured in either PPM or mg/l. Add your level of iron multiplied by 5. Add this number to your hardness level. This final figure will be your Total Hardness Level that we will program into your softener system. To begin programming, first plug in your 7000SXT Valve to a nearby wall outlet. The system will then illuminate. The system will show the time of day and the amount of gallons remaining. This display will switch between these values about every 10 seconds. 1999-2009 QualityWaterForLess.com - 11 - info@qualitywaterforless.com

Set the time on the system to 12:01 PM by pressing either the UP or DOWN arrow as shown in figure 35 below. You may hold the button to allow the time to scroll faster. Once the time display is set to 12:01 PM, press the extra cycle button once as shown in figure 36 below. FIGURE 35 FIGURE 36 To enter master programming mode, press the UP and DOWN buttons TOGETHER and HOLD for 5 seconds, and then release the buttons, as shown in figure 37 below. The display should now show DF / GAL as shown in figure 38 below. (This indicates U.S. Operation Mode - Gallons) Do not change this value, and press the Extra Cycle Button once to continue. FIGURE 37 FIGURE 38 The display should now show 7VT / St2b as shown in figure 39 on the following page. (This indicates Valve Type 7000SXT Mode) Do not change this value, and press the Extra Cycle Button once to continue. The display should now show CT / Fd as shown in figure 40 on the following page. (This indicates Control Type METER Delayed Format) Do not change this value, and press the Extra Cycle Button once to continue. 1999-2009 QualityWaterForLess.com - 12 - info@qualitywaterforless.com

FIGURE 39 FIGURE 40 The display may now show C / 24.0 as shown in figure 41 below. (This indicates the Capacity is currently set to 24,000 grains) Use the UP or DOWN button to change this value to the size of your system, and press the Extra Cycle Button once to continue when finished. The display may now show H / 20 as shown in figure 42 below. (This indicates the Hardness is 20 grains) Use the UP or DOWN button to change this value to the total hardness of you water (as calculated before on page 11), and press the Extra Cycle Button once to continue when finished. FIGURE 41 FIGURE 42 The display should now show RS / SF as shown in figure 43 on the following page. (This indicates Reserve Selection is Safety Factor percentage) Do not change this value, and press the Extra Cycle Button once to continue. The display should now show SF / 15 as shown in figure 44 on the following page. (This indicates the Safety Factor is 15 percent) Use the UP or DOWN button to change this value to 15 for 2-3 people in the home, and "20" for 4 or more people in the home, and press the Extra Cycle Button once to continue when finished. 1999-2009 QualityWaterForLess.com - 13 - info@qualitywaterforless.com

FIGURE 43 FIGURE 44 The display should now show DO / 14 as shown in figure 45 below. (This indicates the Day Override is 14 days the system will regenerate on the 14 th day if the meter does not otherwise automatically initiate a regeneration based on usage.) Do not change this value, and press the Extra Cycle Button once to continue. The display should now show RT / 2:00 as shown in figure 35 below. (This indicates the system will regenerate at 2:00 AM, assuming the system clock is set accurately) Although this is the recommended time, you may change this by using the UP or DOWN buttons, and then press the Extra Cycle Button once to continue. FIGURE 45 FIGURE 46 The display should now show BW / 10 as shown in figure 47 on the following page. (This indicates Backwash Time is 10 minutes in length) Do not change this value, and press the Extra Cycle Button once to continue. The display should now show BD / 60 as shown in figure 48 on the following page. (This indicates Brine Draw Time is 60 minutes) Do not change this value, and press the Extra Cycle Button once to continue. 1999-2009 QualityWaterForLess.com - 14 - info@qualitywaterforless.com

FIGURE 47 FIGURE 48 The display may now show BW / 5 as shown in figure 49 below. (This indicates 2nd Backwash Time is 5 minutes) Do not change this value, and press the Extra Cycle Button once to continue if this value is different, use the UP or DOWN buttons to change this. The display may now show RR / 10 as shown in figure 50 below. (This indicates Rapid Rinse Time is 10 minutes) Do not change this value, and press the Extra Cycle Button once to continue if this value is different, use the UP or DOWN buttons to change this. FIGURE 49 FIGURE 50 The display may now show BD / 12 as shown in figure 51 on the following page. This indicates the length of the Brine Refill Cycle during regeneration. Use the table on the following page to determine the proper salt time setting based on the size of your system. Change the value by pressing the UP or DOWN button until the proper time setting is shown, and press the Extra Cycle Button once to continue when finished. 1999-2009 QualityWaterForLess.com - 15 - info@qualitywaterforless.com

FIGURE 51 System Size Salt Time Setting (0.25 BLFC) 24,000 Grains 15 32,000 Grains 20 40,000 Grains 25 48,000 Grains 30 64,000 Grains 40 80,000 Grains 50 96,000 Grains 60 120,000 Grains 80 *** NOTE: If using Potassium Chloride, please add 30% to the numbers in the table above. This is because Potassium Chloride is a weaker regenerant, and more usage is required per regeneration to achieve the same capacity gain. The display may now show FM / t1.5 as shown in figure 52 below. (This indicates Flow Meter type 3/4" Turbine) Do not change this value, and press the Extra Cycle Button once to continue if this value is different, use the UP or DOWN buttons to change this. The system will now exit the Master Programming mode, and the display should now show the time of day, flowed by the new number of gallons remaining, as shown in figure 53 below. Change the time of day by pressing and holding the UP or DOWN button until the proper time setting is shown. Note that there is a PM light indicator to differentiate between AM and PM times. FIGURE 52 FIGURE 53 Congratuations! Your new 5600SXT system is now programmed and ready for operation. Please move on to the next section on the following page to initialize and start-up your system. 1999-2009 QualityWaterForLess.com - 16 - info@qualitywaterforless.com

Initial Start-Up: With one nearby softened faucet running in the COLD position, slowly open your bypass valve or 3-valve bypass to about ¼ open to allow the air trapped in the softener to escape via your running faucet. See page 6 in this guide for illustrations. NOTE: Opening the bypass too quickly or too fully open may damage your softener or plumbing. Allow the softener tank to slowly fill with water, and then gradually move your bypass valve to the fully open position. NOTE: You may see some initial discoloration from the softened water this is normal and should dissipate within the first 40-50 gallons of water used. Turn off the nearby faucet when the water runs clear. Add approximately five gallons of water to your brine tank, and add 120-160 pounds of pellet, solar, or block salt or potassium chloride to your brine tank. Enjoy Your Softener! Congratulations, you have successfully installed your new water softener with Fleck 7000SXT Meter Valve! Please maintain your system by keeping the softener plugged-in and always keep your brine tank filled with salt to at least above the water level. We appreciate your business, and hope that you enjoy years of trouble-free softened water! - QualityWaterForLess.com 1999-2009 QualityWaterForLess.com - 17 - info@qualitywaterforless.com