B850 Boiler House Energy Monitor

Similar documents
Quick Connect. quick - simple - efficient.

Application/Connection Examples

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

PCS0100en Persy Control Services B.V. Netherlands

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Rack mounted telephone- and leased line modem for industrial applications

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

NC-12 Modbus Application

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Electronic Control Devices The European Product Catalogue 2007

Telephone- and leased line modem for industrial applications TD-36

T0118 T2118 T3118. Instruction Manual

Safety technique. Emergency stop module BO 5988 safemaster

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Duct Humidity Transmitter

Analog signal converters CC-E I/I Current / current isolators

Modular I/O System Analog and Digital Interface Modules

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Contents. Document information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Preset Counter signo 721

MLC TM Maximum Productivity and Versatility for Control without Compromise!

TMS TANK MANAGEMENT SYSTEM

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

AIS750 Series Alarm Annunciator

IntesisBox Modbus Server Fidelio IP

Model: DC-A2IO Advanced HVAC Controller

1 Serial RS232 to Ethernet Adapter Installation Guide

Multifunction devices

IntesisBox KNX Modbus TCP master

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Temperature & Humidity SMS Alert Controller

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Wahl C50 Calibrator FEATURES

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Three-phase monitoring relay CM-PFE

IMR 6000/10../20../30

IntesisBox Modbus Server SAMSUNG Air Conditioners

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

NEW. EVEN MORE data acquisition and test stand automation

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

38 Series - Relay interface modules A

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Digital Pressure Measuring Instrument MDR480

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electronic Control Devices The European Product Catalogue 2007

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

38 Series - Relay interface modules A

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

CompactLogix Power Supplies Specifications

OZS Web server. For LPB/BSB plants

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Series DFMT Digital Paddlewheel Flowmeter

ACS-30-EU-EMDR-10-MOD

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

IntesisBox KNX Modbus RTU master

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Installation manual. Generator Paralleling Controller GPC multi-line C

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Rosemount 333 HART Tri-Loop

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Thyristor-controlled power supplies and battery chargers

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

How To Use A Ds340 (Dsp)

Panel Meters and Controllers Modular Panel Meter Type EDM 35

TX OPEN RS232/485 module

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Digital input modules

J TB/TW Temperature limiter, temperature monitor

Power Meter Series 700

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Transcription:

Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. Copyright 2015 TI-P408-01 AB Issue 2 Boiler House Energy Monitor -W-2 wall mounted The can calculate and display: -P-2 panel mounted - Energy transfer efficiency from fuel to steam - Potential energy losses from TDS and bottom blowdown applications - Energy recovery from condensate return - Steam flow and pressure - Feedwater flow and temperature - Fuel flow For selection of the optimum unit for your application, please visit page 2 'Available options' before placing an order. Description The is a flexible and easy to use Boiler House Energy Monitor that accurately calculates the efficiency of the boiler based on measured inputs from fuel, feedwater, steam output, condensate return and blowdown. The is a boiler house energy monitoring solution that has been designed for organisations operating boilers on an existing installed base and for boiler OEM's where customers specify a requirement for energy monitoring. The calculates a boiler's 'real time' energy transfer efficiency from fuel to steam. It will also measure for energy losses from the boiler due to blowdown applications. Being fully compatible with a wide range of Spirax Sarco flowmetering products the is the heart of a fully integrated system that will provide Operating Managers in an increasing range of industries detailed information to be able to review boiler efficiency against past performance. The unit is available for either wall or panel mounting. The -W-2 wall mounted is mains powered (100 to 250 Vac), while the -P-2 panel mounting is intended for direct connection to a Low Voltage power supply typically found inside PLC panels, i.e. 24 Vdc. The is supplied with a default configuration that makes configuration easy, either off-line with the free PC based software wizard provided with each product. When the configuration has been completed, it can be saved to file or to the free USB memory stick provided, from where it can be plugged in and up-loaded directly into the unit. Alternatively, commissioning can be carried out via a hierarchical menu structure through the front panel. Full commissioning details are included in the Installation and Maintenance Instructions (IMI) supplied with the unit. Spirax Sarco offers a complete range of flowmeters for the measurement of: Gas, Feedwater, Steam and Condensate return. For existing installed flowmeters the can accept 4-20 ma, Pulse and RTD inputs. The is compatible with a large number of interfaces and protocols including: RS-485, Modbus RTU, BACnet MSTP, RJ-45 Ethernet, Modbus TCP / IP, BACnet IP, USB and Hosted http web. A GSM module can be connected to the RS-485 port which enables transfer of information about failures, alarms and measurement values in the form of SMS text messages. Standards and certification This range of products fully comply with the requirements of the European Directives and carry the The is available with the following certification: - Uncertainty Certificate / Inspection Report. Note: All certification / inspection requirements must be stated at the time of order placement. mark when so required. Page 1 of 6

Applications Application Proposed flowmeter ( is the example supplied ) Meter output Gas (Oil, Coal) Thermal mass flowmeter for gas (MTL10) (0) 4-20 ma Boiler feedwater Magnetic flowmeter (ELM) (0) 4-20 ma Boiler steam output Flowmeter (Gilflo, ILVA) (0) 4-20 ma Condensate return Magnetic flowmeter (ELM) (0) 4-20 ma TDS blowdown TDS valve Relay (State) BB blowdown BBD valve Relay (State) Typical boiler house application Condensate return flowmeter and temperature measurement Feedwater flowmeter and temperature measurement Steam flowmeter and optional steam temperature and pressure Process Fuel supply BC3250 Controller Blowdown vessel TDS valve Fuel flowmeter BBD bottom blowdown valve Available options Both s of the series have the same functions and are available as follows: -P for panel mounting and is powered by 24 Vdc. -W for wall mounting and has been adapted to be powered by 100 / 240 Vac. Each is equipped with two analog outputs Offered s of the instruments: -x -2 -P Panel mounted. -W-2 wall mounted -W Wall mounted. -P-2 panel mounted -2 Two analog 4-20 ma outputs. Page 2 of 6

Technical data for the series flow computers User interface, front panel Display type Display size / resolution LED indication Keyboard LCD TFT color, 3.5", with LED backlight 43.8 mm x 77.4 mm / 272 (RGB) x 480 px, 3 two-color LEDs, red / green: ALARM, REC, USB 19 membrane buttons Inputs organization 6 x I type (0 / 4-20 ma): IN1, IN2, IN3, IN4, IN5, IN6 Number of inputs 3 x RTD (4-wire): IN7, IN8, IN9 3 x PULS: IN10, IN11, IN12 I type (0 / 4-20 ma current loop analog inputs) Signal type 0-20 ma or 4-20 ma Transmitter connection 2-wire passive transmitter (supplied from ) or active transmitter (current source transmitter) Input resistance Transmitters supply A / C converter resolution 95 W ± 10% (protected with PTC 50 ma fuse in series) 24 Vdc +10% / -20%; max 22 ma per channel (protected with PTC 50 ma fuse and 100 Ω resistor in series) 18 bit (24 bit Sigma-Delta ADC) 50 Hz / 60 Hz filter Sinc3 digital filter Damping (1 st order Low Pass Software Filter time constant) Measurement resolution Accuracy (at T amb = +25 C / +77 F) 2 s / 5 s / 10 s / 20 s / 30 s / 1 min / 2 min / 3 min / 5 min > 0.01% of FS ± 0.1% of FS (typical W0.05% of FS) Temperature drift Maximum ±0.02% of FS / C Maximum input voltage Galvanic isolation between inputs Galvanic isolation to Analog Outputs, ± 40 Vdc No; common potential of functional GND for all inputs RTD type (3 analog inputs for temperature sensors) Sensor types Measuring range Sensor connection Wire resistance compensation Maximum resistance of connecting wires A / C converter resolution Pt-100 x K; Ni-100 x K; where K = 1..11 (K multiplier, e.g.: K = 2 for Pt-200) -200.. +850 C / -328.. +1562 F for Pt100 x K -60.. +150 C / -76.. +302 F for Ni100 x K 4-wire (2-wire with wire bridges) Automatic, additional manual in range -99.99.. +99.99 50 18 bit (24 bit Sigma-Delta ADC) 50 Hz / 60 Hz filter Sinc3 digital filter Damping (1 st order Low Pass Filter time constant) Measurement resolution Accuracy (at T amb = +25 C / +77 F) 2 s / 5 s / 10 s / 20 s / 30 s / 1 min / 2 min / 3 min / 5min > 0.05% of reading or 0.1 Ω (TBV) ± 0.5 C / ± 0.9 F (typical ± 0.3 C / ± 0.54 F) Temperature drift Maximum ±0.02 C / C / 0.036 F / F Max input voltage Galvanic isolation between inputs Galvanic isolation to Analog Outputs, ± 40 Vdc No; common potential of functional GND for all inputs Page 3 of 6

PULS type inputs (binary / pulse / frequency) Measuring range Minimum pulse width Accuracy for frequency measurement (at T amb = +25 C / +77 F) Maximum input voltage Galvanic isolation between inputs Galvanic isolation to Analog Outputs, Configuration (default): OC or Contact open / closed Open circuit voltage Short circuit current On / off threshold Configuration: Voltage Input Signal amplitude On / off threshold 0.. 20 khz (cut off for f < 0.001 Hz) (0..1 khz with filter jumper J1 / J2 / J3 ON) 25 μs (0.5 ms with filter jumper J1 / J2 / J3 ON) 0.02% ± 40 Vdc No; common potential of functional GND for all inputs (Internal jumper J4 / J5 / J6 ON) 5 Vdc 5 ma 2.7 V / 2.4 V (Internal jumper J4 / J5 / J6 OFF) 4.. 36 Vdc 2.7 V / 2.4 V Input resistance Calculation update rate 10 k Compensated flow and heat energy measurement 1 s Total accuracy of compensated steam, water, other liquid or technical gas flow measurement Typical: better then ± 0.5% (worst case: better then ± 2%) 4-20 ma analog outputs Number of outputs 2 Output signal Resolution Loop resistance (R L ) range for U CC = 24 V 4-20 ma passive (external current loop supply required) 16 bit DAC 0.. 600 Ω Minimum loop power supply voltage U CCmin = RL x 0.022 + 8 Maximum loop power supply voltage Accuracy (at T amb = +25 C / +77 F) 28 Vdc Better than ± 0.2% of FS / C Temperature drift Maximum ± 0.02% of FS / C Galvanic isolation to Analog Inputs, Binary outputs (-W-2) Number of outputs 4 Type of outputs Contact rating (resistive load) Maximum switching voltage Maximum switching power 3 pole (COM, NO, NC) electromechanical relay 3 A at 85.. 250 Vac / 30 Vdc 250 Vac / 125 Vdc 750 VA / 90 W Binary outputs (-P-2) Number of outputs 4 Type of outputs Contact rating (resistive load) Maximum ON resistance Galvanic isolation (optoisolation) 2 pole Solid State Relay 0.1 A at 60 Vac / dc 20 Ω Page 4 of 6

RS-485 / 422 Transmission protocol ASCII Modbus RTU, BACnet MSTP and GSM Number of nodes in network 256 Maximum line length Baud rate Parity control Frame Internal terminating resistor Maximum bus terminal voltages 1 200 m (depends on quality of data cable and baud rate) 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 115.2, 230.4 kbps Even, Odd, None 1 start bit, 8 data bits, parity 1 bit, 1 stop bit Yes, activated with DIP switch -8 V +13 V Minimal driver differential output voltage 1.5 V (for R L = 54 ) Minimum receiver sensitivity Short-circuit / thermal protection Galvanic isolation to Analog Inputs, Analog Outputs, Ethernet Transmission protocol Interface Data buffer Number of opened connections (simultaneously) Connection type 200 mv Yes Ethernet port Modbus TCP, ICMP (ping), DHCP server, http server, BACnet IP 10 BaseT Ethernet 300 B 4 RJ-45 LED indication 2 (build in RJ-45 socket) USB port Socket type A type, according to USB standard Version USB 2.0 Recording format Rated supply voltage Supply voltage range Power consumption Rated supply voltage Supply voltage range Power consumption Wire connection / terminals Conductor cross Section Cable glands Wire connection / terminals Conductor cross Section FAT16 (within a limited scope) 100-240 Vac; 50 / 60 Hz 85.. 264 Vac; 47.. 63 Hz Maximum 20 VA 24 Vdc 18.. 36 Vdc Maximum 8 W Power supply (-W-2) Power supply (-P-2) Wire terminals (-W-2) Spring type terminal block Solid 0.2.. 2.5 mm 2 Stranded 0.2.. 1.5 mm 2 Stranded with ferrule 0.25.. 1.5 mm 2 AWG 26.. 12 4 glands type M20, 2 glands type M16 Wire terminals (-P-2) Screw type terminal blocks, plug type Solid 1.5 mm 2 max Stranded 1 mm 2 max Stranded with ferrule 0.25.. 1.5 mm 2 AWG 30 / 14 Page 5 of 6

Enclosure (-W-2) Enclosure type Dimensions (height x width x depth) Weight net (gross) Wall mounting, Polycarbonate material 216 mm x 260 mm x 125 mm (without cable glands) 246 mm x 260 mm x 125 mm (with cable glands) 290 mm x 300 mm x 165 mm (in cardboard box) approx. 1.7 kg (2.1 kg) Protection class IP65 Enclosure (-P-2) Enclosure type Dimensions (height x width x depth) Panel cut-out dimensions Panel thickness Weight net (gross) Panel mounting, Lexan Resin 920 material 96 mm x 192 mm x 63.5 mm (without terminals) 96 mm x 192 mm x 72 mm (with terminals) 135 mm x 230 mm x 110 mm (in cardboard box) 186 mm x 92 mm 1.. 5 mm approx. 0.6 kg (0.7 kg) Protection class (front / rear) IP65 / IP20 Environmental conditions Ambient temperature Relative humidity Altitude Storage temperature Overvoltage category Pollution degree 0.. +55 C (32.. 131 F) 5.. 95% (non-condensing) 2000 m (6 562 ft) above sea level -30.. +70 C III 3 Panel (when installed in an enclosure) 3 Wall LVD (safety) Electrical safety EN 61010-1 EMC Immunity EN 61326-1 Table 2 Radiated and conducted emissions EN 55011 and EN 55022 to Class B Dimensions / weights (approximate) in mm and kg A B C D E Weight Wall mounted 257 217 134 30 * - 1.70 Panel mounted 206 110 72.3-9.5 0.60 * Approximate dimension as the cable glands are adjustable. -W-2 (wall mounted) A C Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions supplied with the product. Installation notes: 1. The wall mounted -W-2 requires 3 mounting screws (not supplied) to mount to a wall or has optionally a DIN rail mounting. 2. The panel mounted -P-2 is supplied with mounting clamps. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product, provided due care is taken. How to order For the correct product nomenclature for the unit that best suits the intended application please revisit page 2 'Available options' before placing an order. Example: 1 off -W-2 wall mounted energy monitor with two analog 4-20 ma outputs, 240 Vac supply. B D -P-2 (panel mounted) A C B Spare parts There are no spare parts available for the energy monitors. E Page 6 of 6