RAILWAY TECHNOLOGY INDUCTIVE COMPONENTS INDUKTIVE KOMPONENTEN FÜR DIE BAHNTECHNIK



Similar documents
PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

RY2 miniature industrial relays

Your own power station: For continuous power

Pluggable interface relays CR-P Pcb relays

SUCCESS EPCOS Capacitors

DS 600. A contact free flux gate based current measurement sensor 600A rms

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

48 SERIES Relay interface modules 10 A

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Single Output Switching Power Supply

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

38 Series - Relay interface modules A

RM4TG20 three-phase network control relay RM4-T - range V

Operating Manual UWAPS-TINY Series

49 Series - Relay interface modules A. Features

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

TIG INVERTER INSTRUCTION MANUAL

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

38 Series - Relay interface modules A

PHOENIX CONTACT Features

HVAC units for tramways, trains and metros Proven performance, high reliability and low life cycle cost

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Thyristor-controlled power supplies and battery chargers

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

BUSINESS SYSTEMS MONITORING

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Generators TEM. for small hydroelectric power stations. Electric Machines

WINGLIKE ELECTRONICS CO.,LTD

SMS 4 / SMS 5 safety mat Product information

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

How To Build A Low Voltage Capacitor Lvcp

Contents. Document information

SELECTION GUIDE. Nominal Input

EFC Frequency converters

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Redundancy Module QUINT-DIODE/40

HERZ-Thermal Actuators

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

650W Single Output Power Supply

How To Make A Fronius Cl Power Inverter

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Analog signal converters CC-E I/I Current / current isolators

MODEL 2202IQ (1991-MSRP $549.00)

Preset Counter signo 721

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

User s Manual Before using the inverter, you need to read and save the safety instructions.

Type: DILM32 10(24V50HZ) Article No.:

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Consumer Products Services Germany GmbH Türkheim Germany

60 Series - General purpose relays 6-10 A. Features

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Automatic Voltage Regulator User s Manual

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Physical Specifications (Custom design available.)

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

User s Manual AURORA 1.2K/2.2K

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Electric Tubular Motor. ETT Series

Type: DILM9 10(24VDC) Article No.:

Phase Modular Finally the benefits of Modular ups are for all

3/2-way Solenoid Valve, direct-acting, NC or NO

This section applies to the design and installation of transformers.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Speed sensor MiniCoder GEL 247

Three-phase monitoring relay CM-PFE

FP2 Relay. The Best Relaytion

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

TRAMS TROLLEY-BUSES SUBWAY

Inductive sensor NI10-M18-Y1X-H1141

How To Read A Pipe From A Sensor

UMEC International Corporation

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Transcription:

EN DE 2014/15 Ausgabe 1 Edition 1 RAILWAY TECHNOLOGY INDUCTIVE COMPONENTS INDUKTIVE KOMPONENTEN FÜR DIE BAHNTECHNIK BLOCK custom and standard products for railway technology BLOCK Sonderlösungen und Standardprodukte für die Bahntechnik Developed according to the latest railway technology standards 100 % Entwickelt nach den aktuellsten Normen der Bahntechnik 100 %

DEVELOPMENT, PRODUCTION, TEST SYSTEMS, LOGISTICS EVERYTHING UNDER ONE ROOF, MADE BY BLOCK block.eu RAILWAY TECHNOLOGY STANDARDS 100% EN 45545-2 EN 50124-1 EN 60310 WIND ENERGY SYSTEMS REQUIRE ROBUST AND PROVEN PRODUCTS WHERE BLOCK HAS FOCUS TO SUPPORT SUCH APPLICATIONS. SHOCK AND VIBRATION TEST X-RAY INSPECTION 3D CONSTRUCTION LOAD TEST FIRE PROTECTION TEST FINITE ELEMENTS METHOD VACUUM PRESSURE EQUIPMENT

OUR IDEAS TO ENHANCE YOUR MOVEMENT EFFICIENCY BLOCK RAILWAY COMPONENTS: EMC REACTOR Insulation system resistant for mounting in polluted environments (water, snow, brake dust) Cooling method: forced air Ambient temperature: -25 C / +60 C Electrical interface suitable for mounting directly from IP21 into an IP54 housing Voltage max. 1500 V Grid Line reactor DC-link reactor Inverter MF-transformer and output reactor Sine filter Load Rated inductance: 0,4 mh Rated current: 400 A Weight: 30 kg Dimensions: 300 x 220 x 140 mm MEDIUM FREQUENCY TRANSFORMER Insulation system resistant for mounting in polluted environments (water, snow, brake dust) Cooling method: forced air Ambient temperature: -25 C / +60 C Switching frequency 2 khz 8 khz Power up to 120 kva Core material: ferrite or nanocrystalline Power: 110 kva Primary voltage: 650 V Secondary voltage: 700 V / 130 V Switching frequency: 7 khz Cooling method: forced air flow 3 m/s Weight: 45 kg Dimensions: 365 x 330 x 245 mm

SINE FILTER REACTOR Insulation system resistant for mounting in polluted environments (water, snow, brake dust). Cooling method: forced air Ambient temperature: -25 C / +60 C Voltage max. 1500 V Rated inductance: 3 x 0,15 mh Rated current: 3 x 250 A Weight: 35 kg Dimensions: 320 x 280 x 150 mm LINE REACTOR LR3 Use as line reactor, commutating reactor or PFC reactor Ensuring the short circuit voltage of 2 5 % to the mains Power harmonic damping Starting current limitation Increases the service life of consumers Low ripple Bridging voltage dips Peak current limitation Very good corrosion protection and low noise thanks to BLOCKIMPEX vacuum impregnation Integrated lifting rings Multifunctional fixing rail RANGE Rated voltage: 3 x 400 Vac Short circuit voltage: (uk) 2 5 % Rated current: 3 x 2 3 x 1600 A Inductance: 0.019 14.700 mh Insulation: class B or F Ambient temperature: 10 C to +40 C Degree of protection: IP 00 LOW PROFILE TRANSFORMER FLN Minimum size at high output Low height Double input voltage for series or parallel connection Double output voltage for series or parallel connection Designed for high ambient temperatures Permanent corrosion protection, high insulation value and maximum electrical reliability thanks to XtraDensiFill resin encapsulation Coil shell in 2 chamber technology Self extinguishing potting material RANGE Rated input voltage: 2 x 115 Vac Rated output voltage: 2 x 6 2 x 21 Vac Rated power: 3 60 VA Insulation: class B Maximum ambient temperature: 70 C Efficiency: up to 85 % Degree of protection: IP 00 Info IP-CONNECT: A casing structure specifically designed to allow a combination of different protection degrees without additional cable routing. This improves the system s susceptibility to failure and reduces installation costs. IP54 IP21

block.eu AIR CORE REACTOR Insulation system resistant for mounting in polluted environments (water, snow, brake dust) Cooling method: forced air Ambient temperature: -25 C / +60 C Electrical interface suitable for mounting directly from IP21 into an IP54 housing Voltage max. 3000 V RAILWAY SYSTEMS REQUIRE ROBUST AND PROVEN TECHNOLOGY PRODUCTS. BLOCK S FOCUS IS ON SUPPORTING SUCH APPLICATIONS. Rated inductance: 10 mh Rated current: 320 A Weight: 160 kg Dimensions: 420 x 420 x 360 mm Oleksiy Mark - Fotolia.com MEDIUM FREQUENCY TRANSFORMER Very high power density Insulation system resistant for mounting in polluted environments (water, snow, brake dust) Cooling method: forced air Ambient temperature: -25 C / +60 C Electrical interface suitable for mounting directly from IP21 into an IP54 housing Switching frequency: 12 khz - 24 khz Freely scalable power Construction is optimised for air or water cooling (integrated cooling plate) Power: 250 kva Primary voltage: 600 V Secondary voltage: 700 V / 150 V Switching frequency: 20 khz Weight: 55 kg Dimensions: 460 x 460 x 180 mm FULLY CAPSULED TRANSFORMER Housing for indoor mounting Cooling method: natural convection Ambient temperature: -25 C / +60 C Power: 4 kva Primary voltage: 400 V Secondary voltage: 400 V Designated frequency: 50-60 Hz Weight: 61 kg Dimensions: 390 x 390 x 300 mm

Werk 1 Factory 1 Werk 2 Factory 2 Research & Development Every day, more than 50 engineers and specialists in our Research and Development department search for new ways to solve technical challenges using the laws of physics. Through their efforts, we are able to maintain a high standard of quality and keep building on our competitive advantage through innovation.. Forschung und Entwicklung In unserer Forschungs- und Entwicklungsabteilung setzen sich über 50 Ingenieure und Fachkräfte Tag für Tag mit den unterschiedlichsten Gegebenheiten der Physik aus einander. So gelingt es uns, das hohe Qualitätsniveau aufrecht zu erhalten und unseren Innovationsvorsprung weiter auszubauen. Production BLOCK Transformatoren-Elektronik GmbH Max-Planck-Straße 36 46 27283 Verden Germany Phone +49 4231 678-0 Fax +49 4231 678-177 info@block.eu block.eu Using cutting-edge technology, BLOCK sets the standard for optimised production processes. From single units to line production, our flexible manufacturing processes ensure quick and efficient operation. Produktionstechnik Mit zukunftsweisenden Technologien setzt BLOCK Maßstäbe für eine prozessoptimierte Produktion. Flexible Fertigungseinheiten erlauben es uns vom Einzelstück bis zur Großserie schnell und effizient zu fertigen. Testing We employ state of the art production in compliance with applicable standards for each product series. For example railway technology products according to EN 45545-2:2013. Prüfen Wir fertigen nach dem neuesten Stand der Technik und den entsprechenden Normen der jeweiligen Produktreihen. Zum Beispiel für Produkte der Bahntechnik nach EN 45545-2:2013. BT 2014-15A1/DEU-ENG/09-14 ABC/Printed in Germany